Records from 1994 to 2014. Most recent: inspection, 23 June 2014.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
23 June 2014
Deficiency Check · COI Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4896804
13 June 2012
Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4343446
16 February 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4245491
13 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4207392
16 March 2009
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3434335
17 November 2004
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2242559
22 September 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2201887
26 July 2004
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2146093
24 September 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1911776
21 October 2002
Internal Structural Exam · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1695405
11 September 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1674545
4 September 2001
Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1472382
3 October 2000
Deficiency Check · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1443078
30 August 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1461314
3 May 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1049664
19 October 1999
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1448023
27 September 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1034189
29 April 1999
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126161
18 September 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 801937
11 September 1998
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1129821
20 August 1998
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 798409
20 November 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 774612
17 November 1997
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1442632
2 October 1997
Inclining Experiment
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1120403
10 July 1997
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 778784
3 December 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1173478
30 September 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1143566
21 June 1996
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1080095
17 April 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1446345
22 March 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1077467
9 November 1995
Initial Certification · Plan Review "T" Boat
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1191754
14 August 1995
Inclining Experiment
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1184881
15 June 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 861842
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 June 2014
Resolved
JC01- Provide 2 approved Type 1 lifejackets to meet manning requirements on COI. Restricted to operating 43 pax and 2 crew until proof provided.
Due 30 June 2014
Resolved 2 July 2014
Resolution: Received proof from Captain that he purchased two additional lifejackets.
Documentation › Certificates/Documents › Stability Letter
Issued 13 December 2011
Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THEREFORE LIMITED TO: 45 PERSONS (PASSENGERS AND CREW) 46 CFR 170.090
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 16 February 2012
Resolution: Rcvd new Stablilty Letter Adendum revising passenger allowance based on AAWP.
Construction/Loadline › Hull › Keel
Issued 17 November 2004
Resolved
Further investigate and properly repair crack in skeg below shaft housing area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2009
Resolved 26 May 2009
Construction/Loadline › Hull › Keel
Issued 17 November 2004
Resolved
Properly repair previous repair in aft port skeg area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2009
Construction/Loadline › Hull › Side Shell
Issued 17 November 2004
Resolved
Further investigate and properly repair numerous delaminated areas on Starboard side @ waterline.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2009
Construction/Loadline › Structures › Superstructure
Issued 17 November 2004
Resolved
Properly repair small crack in Gusset underneath starboard side aft platform.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2009
Resolved 26 May 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 November 2004
Resolved
Replace missing cotter pin on Fwd Main sail stay.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2009
Resolved 9 July 2009
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 17 November 2004
Resolved
Retighten loose forward stay on starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2009
Resolved 9 July 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 November 2004
Resolved
Retighten stbd fwd rail stantions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2009
Construction/Loadline › Penetrations › Bottom Plug
Issued 22 September 2004
Resolved
Provide plugs for two through hull fittings in port toilet space.
Action required: 705 - Other - as specified
Due 22 October 2004
Resolved 22 October 2004
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 September 2004
Resolved
Properly mount freshwater filter.
Action required: 705 - Other - as specified
Due 22 October 2004
Resolved 22 October 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 September 2004
Resolved
Investigate and properly repair raw water injection into MDE exhaust.
Action required: 705 - Other - as specified
Due 22 October 2004
Resolved 22 October 2004
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 September 2004
Resolved
Remove freshwater vent from bilge and properly mount in engine room.
Action required: 705 - Other - as specified
Due 22 October 2004
Resolved 22 October 2004
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 24 September 2003
Resolved
Provide approved sail plan and maintain approved plan onboard NLT 20 OCT 03.
Action required: 705 - Other - as specified
Due 20 October 2003
Resolved 22 April 2004
Resolution: Received sail plan dated 02 October 1997 for a total sail area of 1699.81 square feet. Vessel has been operating with this square feet of sail since certificated. Vessel master has a copy of this plan on board.
Communications › Alarms/Indicators › Fire Alarm
Issued 24 September 2003
Resolved
Prove proper operation of heat detector in Engineroom space.
Action required: 705 - Other - as specified
Due 20 October 2003
Resolved 22 April 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 24 September 2003
Resolved
Prove proper operation of anchor light.
Action required: 705 - Other - as specified
Due 20 October 2003
Resolved 22 April 2004
Engineering › Diesel Engine (auxiliary) › Gear, Timing
Issued 24 September 2003
Resolved
Provide proper diesel engine mount for generator, prior to operating with passengers onboard.
Action required: 705 - Other - as specified
Due 20 October 2003
Resolved 2 June 2004
Engineering › Shafting/Propeller Arrangements
Issued 21 October 2002
Resolved
Replace prop. LEGACY COMPONENT DESC: Propeller (fixed pitch)
Condition: Damaged By Earlier Event
Due 1 June 2003
Resolved 5 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 21 October 2002
Resolved
Make repairs to rail stanchions IWO aft seats & #8 stbd side from fwdprior to carrying passengers. LEGACY COMPONENT DESC: Deck Rail
Due 1 June 2003
Resolved 5 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 21 October 2002
Resolved
Relag/secure #2 stbd stay.
Due 1 June 2003
Resolved 5 June 2003
Electrical
Issued 4 September 2001
Resolved
PROPERLY ATTACH THE ELECTRICAL BOX AND USE APPROVED STRAIN RELIEF DEVICES.
Condition: Unknown
Due 11 September 2001
Resolved 5 October 2001
Engineering
Issued 4 September 2001
Resolved
PROPERLY REPAIR/REPLACE THE AFT VENT FOR THE FUEL TANK SPACE IWO THE RUDDERPOST.
Condition: Unknown
Due 11 September 2001
Resolved 5 October 2001
Navigation
Issued 4 September 2001
Resolved
PROVIDE CURRENT AND UPDATED CHARTS FOR OPERATING AREA.
Condition: Unknown
Due 11 September 2001
Resolved 5 October 2001
Lifesaving
Issued 30 August 2000
Resolved
RENEW RING LIFE BUOY LIFELINE.
Condition: Unknown
Due 30 August 2000
Resolved 30 August 2000
Lifesaving
Issued 30 August 2000
Resolved
RENEW RETROREFLECTIVE MATERIAL ON BUOYANT APPARATUS.
Condition: Unknown
Due 30 August 2000
Resolved 30 August 2000
Lifesaving
Issued 30 August 2000
Resolved
RENEW LANYARD ON FLOATING WATERLIGHT.
Condition: Unknown
Due 30 August 2000
Resolved 30 August 2000
Navigation
Issued 27 September 1999
Resolved
REPLACE DEFECTIVE NAVIGATION RUNNING LIGHTS.
Condition: Unknown
Due 27 October 1999
Resolved 19 October 1999
Construction/Loadline
Issued 27 September 1999
Resolved
MAKE PERMANENT REPAIR TO THE SOFT AREA ON THE AFT STARBOARD DECK.
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Engineering
Issued 27 September 1999
Resolved
REPAIR LEAKING OIL PAN TO MAIN PROPULSION ENGINE.
Condition: Unknown
Due 27 October 1999
Resolved 19 October 1999
Lifesaving
Issued 27 September 1999
Resolved
CONDUCT FIRE AND MANOVER BOARD DRILLS INT HE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Accommodation/Occupational Safety
Issued 27 September 1999
Resolved
SECURE SEA STRAINER FOR AIR CONDITIONER UNIT PROPERLY.
Condition: Unknown
Due 27 September 1999
Resolved 27 September 1999
Lifesaving
Issued 18 September 1998
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE AND NOT LATER THAN 15MAY99, DEMONSTRATE EMERGENCY DRILLS IN THE PRESENCE OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Lifesaving
Issued 11 September 1998
Resolved
PROVIDE 8 ADDITIONAL LIFE PERSERVERS. VESSEL IS LIMITED TO 44 TOTAL PERSONSUNTIL ADDITIONAL PERSERVERS ARE PROVIDED.
Condition: Unknown
Due 25 September 1998
Resolved 13 October 1998
Lifesaving
Issued 11 September 1998
Resolved
RENEW FLEXIBLE HOSE FOR LPG BARBEQUE STOVE LOCATED ON THE AFTER DECK.
Condition: Unknown
Due 25 September 1998
Resolved 24 September 1998
Documentation
Issued 11 September 1998
Resolved
CONDUCT AN AUDIT OF VESSEL'S CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 11 October 1998
Resolved 2 October 1998
Lifesaving
Issued 17 November 1997
Resolved
CONDUCT SATISFACTORY MAN OVERBOARD DRILL IN THE PRESENCE OF A USCG INSPECTOR PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 17 November 1997
Resolved 17 November 1997
Engineering
Issued 17 November 1997
Resolved
REPLACE WORN STAYSAIL SECURING PIN PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 17 November 1997
Resolved 21 November 1997
Lifesaving
Issued 17 April 1996
Resolved
MARK STOWAGE OF 4 ADULT PFD'S IN PILOT HOUSE.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Documentation
Issued 17 April 1996
Resolved
MAKE AND POST NEAR RADIO VESSEL SPECIFIC EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Lifesaving
Issued 17 April 1996
Resolved
POST OR MAKE AVAILABLE LIFE JACKET DONNING PLACARDS.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Electrical
Issued 17 April 1996
Resolved
PLACE RED "E" ON EMERGENCY LIGHTS IN PASSAGEWAYS BELOW MAIN DECK.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Construction/Loadline
Issued 17 April 1996
Resolved
REPLACE MISSING SCREW ON 2ND CLEAT DOWN ON STBD SIDE.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Unknown
Issued 17 April 1996
Resolved
PRIOR TO CARRYING PASSENGERS IN THE BALTIMORE ZONE, CONDUCT AN OPERATIONAL TEST ON PARTIALLY PROTECTED ROUTE (CHESAPEAKE BAY).
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Construction/Loadline
Issued 17 April 1996
Resolved
TIGHTEN SCREWS ON LAST CLEAT, PORT SIDE.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Electrical
Issued 17 April 1996
Resolved
REPLACE COOLING DISCHARGE HOSE ON GENERATOR.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Lifesaving
Issued 17 April 1996
Resolved
PRIOR TO CARRYING PASSENGERS, ATTAIN ONE ADD'L ADULT PFD AND STENCIL VSL NAME.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Construction/Loadline
Issued 17 April 1996
Resolved
PRIOR TO CARRYING PASSENGERS IN THE BALTIMORE ZONE, PROVIDE SUITABLE DEAD COVERS FOR PORT LIGHTS LOCATED BELOW THE MAIN DECK IN ACCORDANCE WITH 46 CFR 171.119(A)(2).
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Documentation
Issued 9 November 1995
Resolved
PRIOR TO OPERATION PROVIDE DOCUMENTATION OF SATISFACTORY COMPLIANCE WITH CHEMICAL TESTING REGULATIONS OF 46 CFR PART 16 FOR REQUIRED CREW.
Condition: Unknown
Due 9 November 1995
Resolved 9 November 1995
Documentation
Issued 9 November 1995
Resolved
PRIOR TO OPERATION MAKE VESSEL AVAILABLE FOR UNDERWAY EMERGENCY DRILLS WITHLICENSED OPERATOR.
Condition: Unknown
Due 9 November 1995
Resolved 9 November 1995
Engineering
Issued 15 June 1994
Resolved
PERMANENTLY MOUNT ENGINE EXHAUST COOLING WATER HOSE BRACKET.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Construction/Loadline
Issued 15 June 1994
Resolved
MAKE THE VESSEL AVAILABLE FOR DRYDOCK EXAMINATION PRIOR TO MARCH, 1995.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Construction/Loadline
Issued 15 June 1994
Resolved
MAKE THE VESSEL READY AND AVAILABLE FOR A SIMPLIFIED STABILITY TEST BY APRIL, 1995.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Documentation
Issued 15 June 1994
Resolved
PROVIDE DOCUMENTATION SHOWING AN ACTIVE DRUG TESTING PROGRAM.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Documentation
Issued 15 June 1994
Resolved
PROVIDE PLANS SHOWING PROPOSED INSTALLATION OF NEW FUEL TANKS IN THE VESSEL.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Documentation
Issued 15 June 1994
Resolved
PROVIDE A COPY OF THE VESSEL'S PLANS LISTED IN 46 CFR 177.05-1(a)(1) THRU (9) [MIDSHIP SECTION, OUTBOARD PROFILE, INBOARD PROFILE, ARRANGEMENT OF DECKS, MACHINERY/ELECTRICAL INSTALLATION, FUEL TANKS, PIPING SYSTEMS, HULL PENETRATIONS/SHELL CONNECTIONS AND THE VESSEL'S ELECTRICAL PLANS].
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Documentation
Issued 15 June 1994
Resolved
PROVIDE A FCC RADIOTELEPHONE CERTIFICATE FOR THE VESSEL.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Documentation
Issued 15 June 1994
Resolved
PROVIDE TWO YEARS DOCUMENTED CHARTER HISTORY OF THE VESSEL SHOWING_x001C_ CARRIAGE OF THIRTY PASSENGERS.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Lifesaving
Issued 15 June 1994
Resolved
ATTACH AN APPROVED WATERLIGHT TO THE TWENTY-FOUR INCH LIFE RING._x001C_
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Lifesaving
Issued 15 June 1994
Resolved
PROPERLY LABEL THE VESSEL'S BUOYANT APPARATUS AND ENSURE THAT IT IS CARRIEDIN A FLOAT FREE MANNER (NOT TIED OFF).
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Construction/Loadline
Issued 15 June 1994
Resolved
DOUBLE CLAMP ALL THROUGH HULL FITTINGS.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Engineering
Issued 15 June 1994
Resolved
INSTALL REMOTE FUEL SHUT OFF VALVES OUTSIDE THE ENGINE ROOM. MARK THE VALVES PROPERLY WITH AT ONE INCH LETTERING.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Navigation
Issued 15 June 1994
Resolved
PROVIDE A COPY OF THE INTERNATIONAL REGULATIONS FOR PREVENTING COLLISIONS AT SEA, 1972 ( 72 COLREGS ) AND THE INLAND NAVIGATION RULES.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Accommodation/Occupational Safety
Issued 15 June 1994
Resolved
LABEL ALL VALVES SHOWING OPERATION OF VESSEL'S MSD SYSTEM ( OVERBOARD DISCHARGE/ TANK DISCHARGE ).
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Lifesaving
Issued 15 June 1994
Resolved
LABEL EMERGENCY EXITS FROM ALL ACCOMMODATION AREAS.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Lifesaving
Issued 15 June 1994
Resolved
REMOVE ALL COMBUSTIBLES FROM THE VESSEL'S ENGINE ROOM.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Documentation
Issued 15 June 1994
Resolved
PROVIDE DOCUMENTATION THAT THE VESSEL IS CONSTRUCTED OF FIRE-RETARDANT FIBER-REINFORCED PLASTIC OR PROVIDE AN EQUIVALENT DEGREE OF FIRE SAFETY PROTECTION (UNDER THE GUIDELINES OF NAVIGATION AND INSPECTION CIRCULAR 8-87PAGE 1-5 THRU 1-7).
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Construction/Loadline
Issued 15 June 1994
Resolved
PROVIDE ADEQUATE HANDRAILS (42") IN WEATHER DECK AREAS ACCESSIBLE TO PASSENGERS IN ACCORDANCE WITH 46 CFR 177.35.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Electrical
Issued 15 June 1994
Resolved
PROPERLY VENTILATE BATTERY COMPARTMENT IN FORWARD ACCOMMODATION SPACE.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Electrical
Issued 15 June 1994
Resolved
PROVIDE EMERGENCY LIGHTING FOR ALL SPACES ACCESSIBLE TO PASSENGERS BELOW THE MAIN DECK.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994