SENTINEL is a 1986 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in June 2026, along with 15 deficiencies, 1 operational control and 2 casualty investigations in 2009.
Records from 2009 to 2026. Most recent: inspection, 25 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton 64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
26 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 26
25 June 2026Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8279277
18 June 2025Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8162176
17 April 2025Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8046364
15 August 2024Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7873854
6 May 2024In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7888842
20 July 2023Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7723944
6 July 2023Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7735039
25 May 2023COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7673211
25 May 2023In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7673215
28 July 2022Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7460724
15 February 2022Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7396847
6 July 2021Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7247263
3 September 2020Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7048818
1 July 2020Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6991730
13 February 2020Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6908503
11 February 2020Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6906925
31 July 2019Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6750926
28 August 2018In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6525372
7 June 2018COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6382229
16 April 2018Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6388170
7 December 2017Inclining Experiment · Plan Review (Other than "T")
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6348765
3 August 2017Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6220477
28 June 2017Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6160771
29 July 2016Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5953057
7 July 2016Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5896465
26 April 2016In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5862442
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 June 2026Resolved
Vessels shall be inspected for the compliance with the standards required by this subchapter, for items not covered in this subchapter, inspection shall be in accordance with good marine practice. During inspection, it was noticed that the port and stbd main cabin deck edge entry water tight doors were in poor repair. Stbd watertight door was missing the lower water tight seal, and part of its sealing edge was damaged by loading ramps. Port watertight door had three of the dogs missing.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2026
Resolved 11 July 2026
Resolution: Operator provided photos of weather tight seal and dogs installed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 25 June 2026Resolved
Vessels shall be inspected for the compliance with the standards required by this subchapter, for items not covered in this subchapter, inspection shall be in accordance with good marine practice. During inspection, MI noticed the port and stbd side rails aluminum sheathing bolted onto forward bulwark protecting passengers from falling overboard through the rail course was found loose with broken and missing
bolts.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2026
Resolved 11 July 2026
Resolution: Operator provided phote of railing arrangements restored.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 August 2024Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to provisions for a seaworthy hull. MI identified significant water intrusion into the lazarette from the starboard rudder post.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 20 August 2024
Resolution: Received photo from operator. Shaft packing was renewed and the rudder post no longer leaks.
De-lamination found in forepeak IWO no.2 longitudinal frame below no.4 deck beam. Remove damaged fiberglass and repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2023
Resolved 31 July 2023
Resolution: Operator provided proof of repairs.
Fiberglass cracking found in engine room port side fwd of first frame below tool box. Provide repair plans and repair damaged area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2022
Resolved 25 February 2022
Resolution: Received pictures of repaired damage area.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 July 2020Resolved
An inflatable liferaft or inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant for the particular brand. Servicing to be completed no later than the month and year on its servicing sticker affixed. IBA servicing expired JUN2020.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2020
Resolved 6 July 2021
Resolution: Vessels 3 life rafts inspected by Viking on 21Jun21.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 July 2019Resolved
VESSELS OVER 65 FEET MUST BE EQUIPPED WITH 2 FIXED POWER BILGE PUMPS CAPABLE OF 50 GPM. PROVIDE SECOND FIXED POWER BILGE SYSTEM.
46CRF182.520
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2019
Resolved 4 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 31 July 2019Resolved
TUBULAR GUAGE GLASSES FITTED TO DIESEL FUEL TANKS MUST BE OF HEAT RESISTANT MATERIALS ADEQUATELY PROTECTED FROM MECHANICAL DAMAGE. PROVE THE ABOVE REQUIREMENT FOR CURRENTLY INSTALLED GUAGE GLASSES. CLOSE GUAGE GLASS VALVES AND REMOVE HANDLES.
46CFR182.440(a)(7)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2019
Resolved 4 September 2019
Stability › Watertight Integrity › General
Issued 6 July 2017Resolved
Make temporary repairs to holes in forward compartment on collision bulkhead.
Condition: Damaged By Earlier Event
Due 20 July 2017
Resolved 3 August 2017
Resolution: Completed temorary repair of holes with epoxy and a wooden covering. Will complete permanent repairs next dry dock.
Engineering › Fuel Oil Service System › Valve
Issued 6 July 2017Resolved
Adjust/ make repairs to diesel supply valve in generator room and main engine space.
Condition: Improper/Lack of Maintenance
Due 20 July 2017
Resolved 3 August 2017
Resolution: Leaking fuel valves had been properly tightened and cleaned to remove fire hazard.
Documentation › Markings/Placards › Warning Signs
Issued 28 June 2017Resolved
Provide adequate signage for emergency escape in engine and workspace compartments.
Condition: Improper Installation
Due 6 August 2017
Resolved 3 August 2017
Resolution: Emergency signs were properly located.
Provide proof of IBA servicing as per COI. Vessel may transit from Port of Long Beach to Avalon Harbor with out passengers. Vessel is limited to operations with in 3NM from Avalon Harbor until proof of IBA servicing provided.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 3 May 2016
Resolution: Vessel provided proof of IBA servicing.
Lifesaving › Lifefloat › Float Free
Issued 26 April 2016Resolved
Provide float free arrangement for lifefloat on vessel prior to departure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 26 April 2016
Resolution: Operator installed brackets to allow life float to float free.
12 January 2009Routine · role: Involved in a Marine Casualty · activity 3398353
23 November 2009Routine · role: Involved in a Marine Casualty · activity 3638724
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.