MAURY USCG vessel records
← All vessels

TWO HARBORS

Built
1985
Last inspected
23 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH7890
263610
Flag
UNITED STATES
Maury page id
psix-263610

Documentation record

Registered dimensions (L × B × D)81.2 ft × 21.0 ft × 7.0 ft
Registered tonnagegross 88 / net 70
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT SHIPYARD, INC. · WESTPORT, WA, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
70 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 25 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 2 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

23 March 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8279289
20 August 2025 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8214513
27 February 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8046355
13 November 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8035083
27 August 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7981444
8 February 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7845403
25 May 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7673216
16 March 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7619352
2 November 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7591637
18 March 2022 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7414312
11 February 2022 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7380265
7 December 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7364310
23 August 2021 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7294632
7 July 2021 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7270747
7 May 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7192274
17 November 2020 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7096917
19 May 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6887360
28 February 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6615134
27 November 2018 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6587511
1 March 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6335202
23 February 2017 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6069647
5 December 2016 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6052998
28 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5851935

Deficiency record · 25

03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 March 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI observed the two doors leading to the back deck weren't capable of being latched.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2026
Resolved 10 April 2026
Resolution: MI observed the two doors leading to the back deck were capable of being latched-cleared def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 March 2026 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. MI observed instructions for donning life jackets were unreadable. Replace placard to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2026
Resolved 10 April 2026
Resolution: MI observed instructions for donning life jackets were new and readable-cleared def.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 March 2026 Resolved
Penetrations in watertight bulkheads must have means to make them water tight. Marine Inspector (MI) observed bulkhead penetrations that weren't watertight in the crew storage room, old luggage hold, and water tank room. Make all penetrations watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2026
Resolved 10 April 2026
Resolution: Observed bulkhead penetrations that were watertight in the crew storage room, old luggage hold, and water tank room-cleared def
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 February 2025 Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. MI observed (1) lifering was weather worn beyond service.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 March 2025
Resolved 27 February 2025
Resolution: Replaced Lifering during inspection
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 February 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Gaskets around door weathered worn and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 2 April 2025
Resolution: Gasket replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 27 February 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Numerous windows showed signs of water ingress.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 19 March 2025
Resolution: Def cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 February 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Id'd three holes in general seating area with exposed wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 18 March 2025
Resolution: Def cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Id'd excessive oil in bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 18 March 2025
Resolution: Def cleared
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 February 2024 Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). Existing vessels as of July 22, 2016 have 180 days to comply with this requirement. Vessel missing two spanner wrenches. Missing spanners must be replaced. 46CFR181.310(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2024
Resolved 20 February 2024
Resolution: Two new spanner wrenches placed into service.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 February 2024 Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: (a) Every power-driven vessel of 20 meters or over in length while navigating; Vessel does not have a valid FCC Bridge-to-Bridge Radio Certificate (FCC Form 827) on board. Provide required certificate.47CFR80.1001
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2024
Resolved 1 March 2024
Resolution: Bridge to bridge radio certificate issued and onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 February 2024 Resolved
Penetrations in watertight bulkheads must have means to make them water tight. There is a plastic hose penetrating the lazarette fwd watertight bulkhead with no purpose. There are also small holes randomly found in the tank space water tight bulkhead. Make all penetrations watertight. 47CFR171.114(a)(2) (Old T)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2024
Resolved 1 March 2024
Resolution: Penetrations satisfactorily made watertight.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 May 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both side in clearly legible letters at least 2 inches high: "EMERGENCY EXIT, KEEP CLEAR". MI found exit doors used as means of escape with out proper marking.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2023
Resolved 2 June 2023
Resolution: Recieved pictures. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 February 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Vessel to place updated copy on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2022
Resolved 2 May 2022
Resolution: Vessel has valid COD and MISLE is updated as such.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 February 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel to install shaft guard/cover on the bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2022
Resolved 18 March 2022
Resolution: Vessel properly installed shaft guard.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 February 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Vessel had (02) valves in e/r that were not properly plugged. 1 on discharge of fire pump & 1 for port side thru hull (old exhaust)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 February 2022
Resolved 11 February 2022
Resolution: Vessel properly installed brass plugs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 7 May 2021 Resolved
An inflatable liferaft must be serviced at a facility approved no later than the month and year on its servicing sticker. 03 liferafts were last serviced 14APR20. Provide proof of liferaft servicing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2021
Resolution: Removed all IBAs. Installed 7 new LF's. All LF's and installation appeared SAT.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 7 May 2021 Resolved
On a vessel of more than 65 ft. in length, the public address required must be fixed installation and be audible during normal operating conditions. PA system was inoperable. Make proper repairs to prove function.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 7 July 2021
Resolution: PA system was repaired and found working properly.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 May 2021 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date; charts, U.S. Coast Pilot, CG Light List. Vessel had out-of-date charts and pubs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 6 July 2021
Resolution: Replaced outdated charts and publications.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 7 May 2021 Resolved
On a vessel on which the number of passengers by stability, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch number and letters of the entranceway to that deck. Upper deck max. passenger marking missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 6 July 2021
Resolution: Updated passenger count signage on upper deck.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 May 2021 Resolved
Each lighting fixture must have a guard or be made of high strength material. Lighting fixture in Luggage-space missing guard or cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 6 July 2021
Resolution: Lighting fixture cover was properly installed.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 24 February 2017 Resolved
Provide means to secure main ventilation to the engine room in case of fire.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: o/o installed satisfacory means to secure main ventilation to the engine room.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 23 February 2017 Resolved
Provide 2 adult lifejackets.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 23 February 2017
Resolution: Operator immediately replaced missing life jackets with 2 new.
Fire Fighting › Fire Pumps › Pressure
Issued 23 February 2017 Resolved
Install pressure gauge on discharge side of fire pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Pressure gauge installed to the satisfaction of the MI.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 23 February 2017 Resolved
Crop/renew/treat wood rot at fwd stbd corner of engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 23 March 2017
Resolution: Wood rot treated to the satisfaction of the Marine Inspector
Fire Fighting › Ventilation Systems › Ducts
Issued 23 February 2017 Resolved
Provide means to secure abandoned ventilation ducting leading to engine room.
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 24 April 2017

Recorded names · 2

TWO HARBORS EXPRESS (2008–2009), TWO HARBORS FLYER (2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.