MAURY USCG vessel records
← All vessels

WATER TAXI MIAMI 2

WATER TAXI MIAMI 2 is a 1986 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in February 2026, along with 8 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 28 February 2026.

Built
1986
Last inspected
28 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 February 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDFI6258
263665
Flag
UNITED STATES
Maury page id
psix-263665

Documentation record

Tonnage as PSIX records it1 - Regulatory (Subpart C or D), Gross Ton
1 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

28 February 2026 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8324937
17 February 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8311793
5 March 2025 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8088811
20 March 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7883663
16 January 2024 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7849648
25 January 2023 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7626699
1 April 2022 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7422621
21 January 2022 Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7383532
29 January 2021 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7128950
3 February 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6901446
21 January 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6892876
13 March 2019 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6641571
19 April 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6394714
21 March 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6375779
31 January 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6349164
11 January 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6069359
13 January 2016 Drydock Exam · Simplified Stability Test · Internal Structural Exam · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5809624

Deficiency record · 8

03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 February 2026 Resolved
Deck fittings in way of forward hatch covers and fixed seating was found not to be weather tight, allowing free ingress of nuisance water from normal operating conditions and weather. Effect repairs of all weather tight fittings in accordance with an approved repair proposal submitted to the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 March 2026
Resolution: All weather tight fittings tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 February 2026 Resolved
All submersible bilge pumps were not marked as UL 1113 approved or permanently mounted. Provide proof of UL 1113 approval of all installed pumps or permanently install UL1113 submersible bilge pumps as required.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 3 March 2026
Resolution: UL 1113 approved submersible bilge pumps installed and tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 April 2022 Resolved
The fuel shut off valve required to cut the engine will satisfy one means of stopping the engine. Fuel shut off valve is corroded. 46 CFR 182.15-40
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
Resolution: Operator sent video demonstrating operation in open and closed position.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2022 Resolved
Each portable fire extinguisher must be inspected and maintained in accordance with NFPA. Extinguishers have not been serviced in 2020. 46 CFR 176.810(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
Resolution: Operator sent pictures of newly purchased fire extinguishers and associated receipts.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 April 2022 Resolved
Vessel must carry first aid kit with contents under 46 CFR 160.041. First aid kid onboard is incomplete. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2022
Resolved 18 April 2022
Resolution: Owner/operator sent photo of compliant kit purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2022 Resolved
Each ring life buoy with a floating light must have a lanyard of at least 3 feet in length lanyard on vessel is of insufficient length. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2022
Resolved 4 May 2022
Resolution: Owner sent picture of waterlight line.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 3 February 2020 Resolved
Emergency broadcast placard not present. Provide placard IAW 46CFR184.510.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2020
Resolved 24 February 2020
Resolution: Picture evidence submitted to Sector Miami showed taht proper placarding was placed.
Electrical › Electrical Distribution System (service) › Fuse
Issued 21 March 2018 Resolved
46CFR 182 - Replace fuses and satisfactorily test port midship bilge pump #4 and navigational lights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2018
Resolved 22 March 2018
Resolution: Vessel rep provided pictures suporting repairs made and equipment identified in operational condition.

Ownership record