ANTARES

ANTARES is a 1976 freight ship. The Coast Guard has recorded 28 inspections since 1986, most recently in February 2024, along with 29 deficiencies and 6 operational controls, 1 with no removal date recorded.

Records from 1986 to 2024. Most recent: inspection, 6 February 2024.

Built
1976
Last inspected
6 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7508532 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
263756
Flag
FRANCE
—
Maury page id
psix-263756

Inspections, by type

…with no type recorded17
Years with a record 15 calendar years (1986–2024)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it4793 - Convention (Subpart B), Gross Ton
4793 - Regulatory (Subpart C or D), Gross Ton
2702 - Convention (Subpart B), Net Ton
2702 - Regulatory (Subpart C or D), Net Ton
7020 - Dead Weight, Ton
9455 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

6 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7861609
20 August 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2753856
1 August 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2733665
31 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2731211
31 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2817027
22 February 2006 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2589781
25 January 2006 Ballast Water Examination · ILO-147 Exam · MARPOL Annex I Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2573374
20 September 2005 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2497198
19 July 2005 PII Safety Exam · ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2431169
1 September 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2183000
30 January 2004 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2001810
24 March 2003 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1761881
17 January 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1732168
30 December 2002 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1723244
31 August 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1670758
30 June 2002 Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1638913
30 August 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 293224
7 January 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 273442
22 December 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 40178
7 August 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 419243
17 February 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 375317
7 November 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 77492
27 October 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 333362
29 June 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 488678
5 December 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 473081
30 June 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 521968
3 March 1988 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 321713
13 January 1986 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 306496

Deficiency record · 29

Engineering › Generator (propulsion-electric) › Remote Control Circutry
Issued 2 August 2006 Resolved
Number one generator does not start.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2006
Engineering › Generator (propulsion-electric) › Remote Control Circutry
Issued 2 August 2006 Resolved
Number three generator has vital gauges (RPM's, Fuel Press, Water temp etc.) that do not work. The generator will only start from the local position.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2024
Resolved 6 February 2024
Resolution: Closing Open defs from activity # 2733665 they were written prior to departure and the vessel was allowed to leav
Engineering › Compressed Air System (control) › Compressor
Issued 2 August 2006 Resolved
Number two air compressor not working has a broken motor. The wiring is temporarily fixed into an auxiliary pump panel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2006
Engineering › Compressed Air System (control) › Compressor
Issued 2 August 2006 Resolved
Number one air compressor only works locally.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2006
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 2 August 2006 Resolved
CPP hub possibly leaking oil. On inspectors walk through of the vessel noticed a sheen around the hull of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2024
Resolution: Closing Open defs from activity # 2733665 they were written prior to departure and the vessel was allowed to leav
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 22 February 2006 Resolved
Vessel failed to report into the WHALESOUTH Mandatory Ship Reporting System while transiting into the Port of Brunswick, Ga.
Condition: Unknown
Due 22 February 2006
Resolved 22 February 2006
Resolution: Issued LOW
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 July 2005 Resolved
The No.1 Auxiliary Engine cooling water pump has a temporary patch on suction side of the pump between the pump housing and flange.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 July 2005
Resolved 20 September 2005
Resolution: Received Class report verifying that repairs have been made.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 2 September 2004 Resolved
Ground fault detected on 220 V feeder panel, locate ground and repair to satisfaction of class within 30 days.
Action required: 705 - Other - as specified
Due 1 October 2004
Resolved 7 September 2004
Resolution: Received class report attesting to repair.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 2 September 2004 Resolved
Approx. 2 inches of standing water located on deck in emergency fire pump room. Have class conduct a full survey function test on emergency fire pump and compartment including piping and seals prior to departure from the port of Hampton Roads.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2004
Resolution: Received class report attesting that the full survey function test has been completed. The emergency fire pump was overhauled and the mechanical seal was replaced.
Fire Fighting › Fire Hoses › Condition
Issued 2 September 2004 Resolved
Examined 7 fire hoses with 3 failures. Replace with 3 new fire hoses and have class conduct full survey of all hoses and attest to integrity of each hose prior to departure from the port of Hampton Roads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attesting that all fire hoses tested satisfactory. Three (3) were renewed. 11 hoses are now in good order.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 2 September 2004 Resolved
Several flame screens were cracked and blocked with residue. Replace flame screens on fuel oil and lube oil vent piping portside aft. Have class conduct survey of all flame screens and attest to proper installation and quality of each prior to departure from the port of Hampton Roads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attesting that all flame screens on the lube oil and fuel oil vents on the poop deck were renewed. Survey complete.
Fire Fighting › Fire Main › Condition
Issued 2 September 2004 Resolved
Noticed 3 leaks on fire main piping system and 2 leaks from valve stem (port and starboard) aft of #1 hold. Have class conduct survey on entire fire main system and associated valves prior to departure from the port of Hampton Roads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attesting that the survey on the fire main system has been completed. The fire main piping was hydro tested and approx. 12 mtrs of piping was renewed.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 2 September 2004 Resolved
Have class attest to replacement of fire suits prior to departure from the port of Hampton Roads.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attesting to two (2) new fire suits.
Lifesaving › Buoyant Apparatus › Float Free
Issued 2 September 2004 Resolved
EPIRB not mounted in location where able to float free. Relocate and mount EPIRB in location where able to float free prior to departure from the port of Hampton Roads.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attest that the EPIRB has been re-mounted on the starboard side of the bridge wing where it can now float free.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 2 September 2004 Resolved
No containment on fuel oil and lube oil vent piping (portside aft location). Install permanent containment around fuel oil and lube oil to satisfaction of class prior to departure from the port of Hampton Roads.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attesting that a total of six(6) oil spill containments have been fabricated and installed in way of lube oil and fuel oil vents on both port and starboard side.
Construction/Loadline › Structures › Deck Plating
Issued 2 September 2004 Resolved
Ladder leading up to anchor windlass starboard side needs repair approx. 2 feet from bottom (both welds cracked/coming apart). Have class attest to proper repairs prior to departure from the port of Hampton Roads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attesting to proper repair of ladder.
Documentation › Certificates/Documents › IOPP Certificate
Issued 2 September 2004 Resolved
Have class amend IOPP certificate to reflect new OWS installation prior to departure from the port of Hampton Roads.
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received clas report attesting that the IOPP now reflects the new OWS installation.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 2 September 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 8 September 2004
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Personnel › Certificates/Documents/Licenses › License, Second Mate
Issued 2 September 2004 Resolved
2nd Officer's Panamanian endorsements not on board vessel. Provide proof of Panamaian endorsements by either original endorsement or application to satisfaction of class prior to departure from the port of Hampton Roads.
Action required: 705 - Other - as specified
Resolved 8 September 2004
Resolution: During audit with class, the boarding team verified the validity of the 2nd Officer''s Panamanian endorsement.
Operations/Management › Pollution › Control of Garbage
Issued 2 September 2004 Resolved
Have class attest to permanent removal of 55 gallon drum (located on stern deck) used for burning oily rags prior to departure from the port of Hampton Roads.
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attesting to the permanent removal of the 55 gallon drum.
Lifesaving › Lifebuoys › Serviceable
Issued 2 September 2004 Resolved
Replace entire supply of ship's lifebuoys with approved lifebuoys to satisfaction of class prior to departure from the port of Hampton Roads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attesting to renewal of all life rings with Solas approved type.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 2 September 2004 Resolved
Have class attest to replacement of entire supply of ship's life jackets with approved life jackets prior to departure from the port of Hampton Roads.
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attesting that all life jackets have been replaced with approved type. Total nineteen (19).
Lifesaving › Launching Appliances › Release Mechanism
Issued 2 September 2004 Resolved
Have class attest to replacement of hydrostatic release mechanism on starboard side liferaft with approved type prior to departure from the port of Hampton Roads.
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attesting that the hydrostatic release is of the approved type.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 2 September 2004 Resolved
Have class conduct full survey on both lifeboats including replacement of sail on portside lifeboat prior to departure from the port of Hampton Roads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report that the survey on both lifeboats have been completed and found satisfactory. Class also attested to the temp. repair to the portside lifeboat''s sail until vessel can purchase a new one.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 2 September 2004 Resolved
Have class attest to lifesaving maintenance log which is specific to ship, year of build and all lifesaving equipment onboard prior to departure from the port of Hampton Roads.
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report attesting that the Life Saving Maintanence Log has been examined and is now corrected.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 2 September 2004 Resolved
Have class attest to adequate supply and placement of SOLAS training manuals onboard prior to departure from the port of Hampton Roads.
Action required: 705 - Other - as specified
Resolved 7 September 2004
Resolution: Received class report that two new SOLAS training manuals have now been provided.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 2 September 2004 Resolved
Vessel/Company has failed to fully implement the requirements of SOLAS 74 Amendment Chapter IX. Vessel is required to have ISM audit from recognized organization approved by flag state within 72 hours in the presence of a US Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 8 September 2004
Resolution: Completed PSC/SMS follow-up with recognized organization approved by flag state. Both recognized organization and US Coast Guard Marine Inspector found vessel to be in compliance with the ISM code.
Navigation › Collision/Grounding Avoidance
Issued 30 December 2002 Resolved
Echo-sounding device damaged due to rough weather during voyage to the United States. LEGACY COMPONENT DESC: Echo-sounding Device
Condition: Unknown
Due 31 January 2003
Resolved 24 March 2003
Resolution: New echo-sounding device installed.
Documentation
Issued 7 August 1998 Resolved
Prior to 08AUG98 or entering next U.S. port of call provide a SOPEP approval letter from authorized class society.
Condition: Unknown
Due 8 August 1998
Resolved 24 August 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.