Records from 2001 to 2002. Most recent: inspection, 5 May 2002.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Deck/Cargo
Issued 23 August 2001
Resolved
Have class address condition of crane hydraulic, cargo securing mechanisms,& hydraulic piping.
Condition: Unknown
Due 21 September 2001
Resolved 21 September 2001
Documentation
Issued 23 August 2001
Resolved
Clear all outstanding deficiencies issued by MSO Lake Charles.
Condition: Unknown
Due 21 September 2001
Resolved 21 September 2001
Lifesaving
Issued 23 August 2001
Resolved
Provide a light for portside lifebuoy on main deck.
Condition: Unknown
Due 23 August 2001
Resolved 24 August 2001
Deck/Cargo
Issued 23 August 2001
Resolved
Repair hydraulic leaks & soft patches on piping for cargo hatches (portside).
Condition: Unknown
Due 21 September 2001
Resolved 21 September 2001
Documentation
Issued 23 August 2001
Resolved
Provide valid crew documents in accordance with Safe Manning document, specifically oiler(as required).
Condition: Unknown
Due 23 August 2001
Resolved 29 August 2001
Fire Fighting
Issued 2 July 2001
Resolved
Replace various gaskets in fire hoses, nozzels, and fire mains throughout the ship. SOLAS 74 II-2/4.7
Condition: Unknown
Due 25 August 2001
Resolved 21 September 2001
Navigation
Issued 2 July 2001
Resolved
GPS not working properly. 33 CFR 164.41
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Lifesaving
Issued 2 July 2001
Resolved
Line-throwing device missing one charge. SOLAS 74 (AMENDED) III/17
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Accommodation/Occupational Safety
Issued 2 July 2001
Resolved
Certify sewage tanks. 33 CFR 159.12
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Electrical
Issued 2 July 2001
Resolved
Missing non-conductive matting in front of electric palel in engine controlroom. SOLAS 74 II-1/40.1.3
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Navigation
Issued 2 July 2001
Resolved
Pre-arrival checks not logged. 33 CFR 164.25
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Lifesaving
Issued 2 July 2001
Resolved
Replace line on smoke signals attatched to life rings on the bridge wings. SOLAS 74 (AMENDED) III/7.1
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Lifesaving
Issued 2 July 2001
Resolved
Replace buoyant lifeline on portside, maindeck lifering. _x001C_ SOLAS 74 (AMENDED) III/31.4
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Lifesaving
Issued 2 July 2001
Resolved
Replace expired distress signals._x001C_ SOLAS 74(AMENDED) III/6.3
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Fire Fighting
Issued 2 July 2001
Resolved
Firemans outfit missing flashlight and hatchet. Face sheild on the helmet needs to be replaced. _x001C_ SOLAS 74 II-2/17.3
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Electrical
Issued 2 July 2001
Resolved
Missing machinery guards on generators. SOLAS 74 II-1/26.1
Condition: Unknown
Due 25 August 2001
Resolved 21 September 2001
Engineering
Issued 2 July 2001
Resolved
Missing containment for fuel oil, lube oil vents, and bunkering stations._x001C_ 33 CFR 155.320
Condition: Unknown
Due 25 August 2001
Resolved 21 September 2001
Electrical
Issued 2 July 2001
Resolved
Missing light covers in engine room. SOLAS 74 II-1/40.1.3
Condition: Unknown
Due 25 August 2001
Resolved 21 September 2001
Accommodation/Occupational Safety
Issued 2 July 2001
Resolved
A/C inoperable. ILO 147
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001
Navigation
Issued 2 July 2001
Resolved
Missing Coast Pilot. 33 CFR 164.33(a)(2)(i)
Condition: Unknown
Due 24 August 2001
Resolved 24 August 2001