LADY VIRGINIA II

LADY VIRGINIA II is a 1985 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in March 2026, along with 68 deficiencies and 1 casualty investigation in 2003.

Records from 2003 to 2026. Most recent: inspection, 16 March 2026.

Built
1985
Last inspected
16 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB5872
263883
Flag
UNITED STATES
Maury page id
psix-263883

Documentation record

Registered dimensions (L × B × D)56.0 ft × 16.0 ft × 9.7 ft
Registered tonnagegross 58 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDMR YACHTS, INC. · ARUNDEL, ME, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portSEABROOK, NH
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 9 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Simplified, Gross Ton
46 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

21 inspections, each with its date, unit and type; 68 deficiencies with the resolution recorded against each; 1 other recorded name, with years; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

16 March 2026 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8327265
2 January 2026 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8287736
7 October 2025 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8246946
19 September 2024 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8004891
11 March 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7874215
5 September 2023 COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7784911
30 March 2023 Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7660593
19 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7558851
25 October 2021 Internal Structural Exam · Construction Oversight · Administrative Inspection · Drydock Exam · Simplified Stability Test · Plan Review "T" Boat
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7387471
23 September 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7319073
13 March 2020 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6926093
4 February 2020 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6901921
7 January 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6883515
1 October 2019 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6831155
13 June 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6713131
27 December 2018 COI Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6599085
9 February 2018 Deficiency Check · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6350953
10 January 2018 Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6331972
28 February 2017 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6096054
3 February 2016 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5808579
12 January 2016 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5795634

Deficiency record · 68

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 January 2026 Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway...Sea chests, sea valves, and sea strainers must be opened for examination. Sea valve for generator cooling water intake was unable to be tested due to the pipe breaking while trying to access the valve. Operator is to repair/replace the pipe and valve prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 16 March 2026
Resolution: Operator installed new valve and pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 January 2026 Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. Operator had removed the propellers for routine maintenance prior to the inspection. Operator is to reinstall the propellers for inspection prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 16 March 2026
Resolution: Operator reinstalled propellers, jam nuts and retaining pins.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 October 2025 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date installed. Hydrostatic release expired Sept 2025. Limited to 3 miles. Corrected prior to end of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2025
Resolved 7 October 2025
Resolution: Crewmember went to store and purchased HSR. HSR was installed prior to end of inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 October 2025 Resolved
All vessels must have navigation lights in compliance with applicable sections of the international and inland rules. Inspector found starboard sidelight extinguished/inoperative. Operation restricted to actual or forecast visibility of 2nm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2025
Resolved 8 October 2025
Resolution: Light repaired and tested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 September 2024 Resolved
Each disposable hydrostatic release must be marked with an expiration date of two years after the date installed. HSR marked April 2024.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 September 2024
Resolution: Hydrostatic release replaced and marked 2 years (2026).
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 19 September 2024 Resolved
A vessel must comply with applicable radio requirements of Federal Communications Commission as set forth in 47 CFR part 80. Limited to 20 miles as vessel does not have a radio meeting the requirements of this part for operation beyond 20 miles.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 21 September 2024
Resolution: Vessel owner elected to reduce route to limited coastwise therefore no longer requiring radio equipment for beyond 20 miles.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 September 2024 Resolved
At each inspection owner must have fire protection system ready for inspection. Pre engineered system manufactured 1/11 and has not undergone hydrostatic or visual in lieu of hydrostatic in accordance with MI notice 02-12 provided to operator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2025
Resolution: Fireboy cylinder received visual inspection in lieu of hydro by facility with valid DOT RIN.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 7 September 2023 Resolved
A vessel must comply with applicable requirements for any radio installations. FCC safety radio certificate expired July 2023.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 September 2023
Resolution: Safety radiotelephony certificate issued.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 September 2023 Resolved
At each inspection all ovserved unsafe practices, fire hazards, and other hazardous conditions must be corrected. Tank space unable to be inspected due to high carbon monoxide and hydrogen sulfide levels.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2023
Resolution: Vessel owner corrected exhaust leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2023 Resolved
Discharge ends of fuel tank vents must be fitted with removable flame screens of 30 x 30 mesh. Port and starboard vents do not have screens.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2024
Resolution: Mesh installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 September 2023 Resolved
A vessel must carry a first aid kit that meets 46 CFR 199.175(b)(10). Vessel kit contains multiple expired items.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2023
Resolution: New kit was purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 September 2022 Resolved
Each flare carried must be stowed in a portable watertight container, of a bright color and marked "DISTRESS SIGNALS" in legible contrasiting letters at least .5 inches high. Distress signals were stored in a non watertight tool case.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 30 March 2023
Resolution: Vessel operator purchased brightly colored watertight container and labeled it.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 September 2022 Resolved
The certificate of inspection must be posted under glass or other suitable transparent material, such that all pages are visible in a place likely to be seen by passengers. COI was not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 30 March 2023
Resolution: COI posted.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 19 September 2022 Resolved
Each survival craft must be secured to the vessel by a painter with a float free link. Vessel survival craft hydrostatic release was improperly installed and not secured to the vessel. Corrected by end of inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2022
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 September 2022 Resolved
A vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible; vessel was unable to show that the elecronic charts being used were updated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 7 September 2023
Resolution: Charts are being updated online.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 September 2022 Resolved
A vessel must comply with the applicable requirements for any radio as set forth in 47 CFR part 80. VHF radio onboard vessel is programmed with an MMSI number that does not belong to this vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 30 March 2023
Resolution: Radio was programmed with proper MMSI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2022 Resolved
Each small battery installation must be protected from falling objects. Two battery boxes located under the operating station do not have covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 30 March 2023
Resolution: Covers fabricated and installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew and the vessel from electrical hazards including fire and electric shock. Port side electrical shore tie is not longer used, connections are cut inside the vessel and are exposed. Stern shore tie connection is burned inside. Shore tie cable from dock has plug that is not properly installed and is taped. The electrical arrangement behind the operating station switchboard has 1) wires that are worn/aged with exposed conductors 2) butt connected splices 3) damaged/corroded current transformer 4) terminal lugs improperly installed 5) dead ended conductors
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2022
Resolved 19 September 2024
Resolution: Vessel owner completed multiple repairs to electrical system.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 September 2021 Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down...all engines that draw intake air from within the protected space; and A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: A light to indicate discharge [and] An audible alarm that sounds upon discharge. LADY VIRGINIA II Fireboy system does not shut down generator, and does not alarm upon simulated discharge. Make proper repairs and test to satisfaction of [name withheld] OF PASSENGERS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2021
Resolution: System re-wired and tested to shutdown generator and properly alarm.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 September 2021 Resolved
The [fuel] shutoff valve at the tank shall be operable from outside the tank compartment. On LADY VIRGINIA II, there is currently no fuel shutoff valve at the tank for the generator fuel line that is operable from outside the tank compartment. Make modifications as necessary to ensure the system fully meets this requirement PRIOR TO CARRIAGE OF PASSENGERS. 46 CFR 182.20-40(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2021
Resolution: Valve installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 September 2021 Resolved
Each vessel that operates on the high seas...must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. On LADY VIRGINIA II, the EPIRB battery is expired. VESSEL LIMITED TO 3 NM FROM SHORE UNTIL CORRECTED.
Action required: 705 - Other - as specified
Resolved 25 September 2021
Resolution: Operator purchased/registered new EPIRB
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 23 September 2021 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. LADY VIRGINIA II currently has no operable MF-DSC/SSB radio installation. VESSEL RESTRICTED TO 20 NM FROM LAND UNTIL CORRECTED.
Action required: 705 - Other - as specified
Resolved 18 November 2022
Resolution: Cleared deficiency due to recent CG policy change regarding MF/HF voice monitoring.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 23 September 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 5 October 2021
Resolution: Updated list provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 September 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit on LADY VIRGINIA II is missing multiple required items. PROVIDE PROPER APPROVED FIRST AID KIT NLT 07OCT21.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 5 October 2021
Resolution: Operator provided new first aid kit.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 September 2021 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.Operator of LADY VIRGINIA II was unable to produce a valid FCC Station License. PROVIDE NLT 07OCT21.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 5 October 2021
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 September 2021 Resolved
A suitable marine type strainer shall be fitted in the fuel supply line in the engine compartment. Drip pans fitted with flame screens may be required under fuel strainers other than those mounted on the engine. On LADY VIRGINIA II, the port side RACOR filter is made from a material other than steel and is not fitted with a proper flame impingement bowl. INSTALL PROPER EQUIPMENT NLT 07OCT21. 46 CFR 182.20-40(b)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 5 October 2021
Resolution: Installed required equip.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 September 2021 Resolved
All vessels shall be provided with not less than two avenues of escape from all general areas...where the crew may be...normally employed. On the LADY VIRGINIA II, the E/R does have two hatches that open to the main deck; however, the second means of escape does not meet the requirements of this cite, including suitable means to escape, and marking requirements. Discussed and provided requirements to vessel rep. ENSURE BOTH MEANS OF ESCAPE FROM THE E/R MEET THE REQUIREMENTS OF THIS CITE NLT 07OCT21. 46 CFR 177.15-1 46 CFR 185.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 5 October 2021
Resolution: Means of escape upgraded to meet the requirements.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 September 2021 Resolved
Each hatch exposed to the weather must be watertight and...be attached to the hatch frame or coaming by hinges, captive chains, or other devices to prevent its loss. On LADY VIRGINIA II, the forepeak hatch is broken and gasket/captive device not installed. RENEW OR REPLACE HATCH TO MEET FULL REQUIREMENT NLT 07OCT21. 46 CFR 171.124
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 5 October 2021
Resolution: New hatch installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 September 2021 Resolved
A voltmeter and an ammeter shall be provided that can be used for measuring voltage and current of each generator that is in operation. For alternating-current generators a means for measuring frequency shall also be provided. LADY VIRGINIA II currently is not fitted with means to measure these operating parameters. INSTALL REQUIRED METERS NLT 07OCT21. 46 CFR 183.10-5(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 5 October 2021
Resolution: Meters installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 September 2021 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. On LADY VIRGINIA II, the portable extinguisher at the operating station has lapsed on required tests and inspections. PROVIDE EVIDENCE OF PROPER INSPECTION/SERVICING NLT 07OCT21.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2021
Resolved 5 October 2021
Resolution: New Extinguisher provided.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 September 2021 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Operator of LADY VIRGINIA II could not produce logs of any required drills. Drills conducted as part of the inspection; operator instructed to log these and begin conducting periodic drills and logging them as required. CORRECTED ON THE SPOT. 46 CFR 185.520 46 CFR 185.524
Action required: 10 - Deficiency Rectified
Resolved 23 September 2021
Resolution: Corrected on the spot.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 September 2021 Resolved
LADY VIRGINIA II Operator not able to produce records/logs of any of the required maintenance, testing, and inspection of the lifesaving equipment required by 46 CFR 185 SUBPART G, including EPIRB. Operator instructed to begin conducting and recording these required activities immediately. CORRECTED ON THE SPOT. 46 CFR 185.700 THROUGH 46 CFR 185.740 AS APPLICABLE.
Action required: 10 - Deficiency Rectified
Resolved 23 September 2021
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2020 Resolved
Provide additional lights for PFD's
Due 15 May 2020
Resolved 12 May 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 April 2020 Resolved
Replace stbd nav light bulb
Due 15 May 2020
Resolved 12 May 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 April 2020 Resolved
Repalce fire hose and nozzle
Due 15 May 2020
Resolved 12 May 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 April 2020 Resolved
Replace high bilge alarm speaker
Due 15 May 2020
Resolved 12 May 2020
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 April 2020 Resolved
Provide VHF with DSC capabilities
Due 15 May 2020
Resolved 12 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 January 2020 Resolved
Replace flare storage box with a watertight container.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2020
Resolved 4 February 2020
Resolution: Flare storage box was replaced with a watertight container.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2020 Resolved
Remove or properly terminate in a junction box the cut wire overhead between the engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2020
Resolved 4 February 2020
Resolution: Dead-end wiring was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2020 Resolved
Enclose the bare light bulb above the air compressor in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2020
Resolved 4 February 2020
Resolution: New light enclosure was purchased and installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 October 2019 Resolved
Crew and Passenger List has not been kept for each voyage with overnight passengers. 46 CFR 185.502
Action required: 10 - Deficiency Rectified
Due 1 October 2019
Resolved 1 October 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 October 2019 Resolved
Install Emergency Lighting in below-deck hold forward of the engine room. Emergency Lighting must turn on automatically upon failure of main lighting system. Passengers are prohibited from accessing the space until this is installed. 46 CFR "Old T" 184.30-5
Action required: 705 - Other - as specified
Due 1 October 2019
Resolved 10 October 2019
Resolution: Own state he will no longer allow passengers in this space.
09 - Working and Living Conditions › 091 - Living Conditions › Berth dimensions, etc.
Issued 1 October 2019 Resolved
Passenger overnight accommodations in the below deck hold forward of the engine room substantially do not meet construction requirements in 46 CFR "Old T". Area must be modified prior to being used as overnight passenger accommodations. Submit plans to OCMI prior to beginning any modifications. Space may be used as a crew accommodation only. 46 CFR "Old T" 177.30-7
Action required: 705 - Other - as specified
Due 1 December 2019
Resolved 10 October 2019
Resolution: Own state he will no longer allow passengers in this space.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 December 2018 Resolved
Move mast headlight to centerline of vessel. Ensure visibility 22.5 degrees abaft the beam on either side of the vessel. 33 CFR 83.20(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
Resolution: Masthead light moved to centerline and is clear of radar
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 December 2018 Resolved
Wire splices shall be made in junction boxes. 46 CFR "Old T" 183.05-50(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 December 2018 Resolved
Dead End wiring shall be removed. 46 CFR "Old T" 183.01-15(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 December 2018 Resolved
Ring Buoy must be replaced with one meeting 46 CFR 160.050 and appropriate for the size and operation of the vessel. 46 CFR 180.70(a)(2) and (b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 December 2018 Resolved
Label at the operating station which space automatic bilge pumps are operating. 46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 December 2018 Resolved
Bolt on the port engine jacket water pump shall be replaced. 46 CFR "Old T" 182.01-5(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 December 2018 Resolved
Bilge manifold in the engine room shall be labeled with the compartments served. 46 CFR "Old T" 182.25-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 December 2018 Resolved
Permanent means shall be made to secure ventilation to the Engine Room. 46 CFR "Old T" 182.20-40(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 December 2018 Resolved
Fuel shutoff valve in the aft section of the cabin shall be made easily operable. 46 CFR "Old T" 182.20-40(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 December 2018 Resolved
Only 35 adult and 10 child PFDs have water lights required by an Oceans Route. Until rectified, vessel is restricted to 35 Adults and 10 Children on an Oceans route. 46 CFR 180.75(a)
Action required: 705 - Other - as specified
Due 28 January 2019
Resolved 4 February 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 December 2018 Resolved
Permanently install engine room lighting with all connections inside junction boxes. 46 CFR 183.10-20(j)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 December 2018 Resolved
Place plug on port fuel strainer in engine room. 46 CFR "Old T" 182.0-40(b)(7)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 December 2018 Resolved
Ground in receptacle outlet in machinery space is disconnected. Reconnect ground. 46 CFR 183.10-20(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2019
Resolved 16 January 2019
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 January 2018 Resolved
Masthead light inop and crackled. Make masthead light operational and replace lens.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 15 March 2018
Resolution: O/O replaced masthead light.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 10 January 2018 Resolved
Starboard engine fuel strainer flame shield has valve but no plug. Install plug on below valve.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Resolution: Vessel owner installed threaded plug in fuel strainer flame shield drain.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 January 2018 Resolved
Excessive engine oil in engine room bilge. Bilge to be cleaned prior to operation of the bilge manifold.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Resolution: Vessel owner cleaned bilge in engine room and operated bilge suction in space.
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 January 2018 Resolved
Unable to conduct drills due to ice conditions in zone. Underway dills, and checks of propulsion and steering shall be conducted prior to credit annual
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Resolution: Operated propulsion and steering equipment. Chose to conduct fire and abandonship drill on [name withheld] (same owners/crew).
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 February 2017 Resolved
Remove wire nuts under pilothouse and replace with acceptable connector
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 28 March 2017
Resolution: Wire nuts removed and replaced with butt connectors
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 February 2017 Resolved
Remove dead end wiring as discussed. Remaining wiring must be labeled and provided with shock protection
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 28 March 2017
Resolution: All dead end wiring removed and capped/labeled
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 February 2017 Resolved
Prove operating station extinguisher has been serviced
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 28 March 2017
Resolution: Portable extinguisher serviced
Engineering › Fuel Oil Service System › Hose
Issued 28 February 2017 Resolved
Replace fuel hose on stbd side Racor filter
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 28 March 2017
Resolution: Hose renewed with proper J1942 hose
Engineering › Steering Gear System › Hydraulic Hose
Issued 28 February 2017 Resolved
Replace stbd side hydraulic pump discharge hose
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 28 March 2017
Resolution: Hose renewed with proper J1942 hose.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 28 February 2017 Resolved
Fill engine room bulkhead penetrations with firestop
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 29 March 2017
Resolution: Received photo via e-mail of penetrations filled with foam fireblock.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 28 February 2017 Resolved
Provide proper amount of adult lifejackets. Vessel is restricted to 52 pax, 3 crew.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 25 May 2017
Resolution: Correct number on board.
Electrical › Electric Generation Source (service) › Generator
Issued 28 February 2017 Resolved
Make stbd generator available for inspection when operable.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 10 October 2018

Casualty record · 1

7 August 2003Routine · role: Involved in a Marine Casualty · activity 1870192
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

JERSEY DEVIL (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.