MAURY USCG vessel records
← All vessels

LEGACY

Built
1985
Last inspected
10 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 February 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ8642
263938
Flag
UNITED STATES
Maury page id
psix-263938

Documentation record

Registered dimensions (L × B × D)39.2 ft × 13.5 ft × 5.1 ft
Registered tonnagegross 26 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMICHAEL FITZ CUSTOM BOATS · NAPLES, FL, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portORANGE BEACH, AL
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 48 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 21

10 February 2026 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8308652
14 May 2025 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8129709
1 April 2025 Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 8110714
24 July 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7966160
18 January 2024 Deficiency Check · Drydock Exam · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7851179
16 May 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7690049
14 March 2023 Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 7652118
16 May 2022 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7464651
19 January 2022 Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7382896
4 August 2021 Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7277267
6 May 2020 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949312
8 January 2020 Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6885653
25 July 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6762049
2 August 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6499245
8 January 2018 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6334137
30 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6297880
1 August 2017 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit · Plan Review "T" Boat
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6227738
24 August 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5981816
18 August 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5976995
1 August 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5959792
17 February 2016 Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5817101

Deficiency record · 48

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 February 2026 Resolved
One railing pedestal port and one railing pedestal starboard have cracked or broken off. Repair or replace as appropriate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2026
Resolution: observed rectification
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2026 Resolved
Starboard fuel tank fill bonding wire is severely corroded and no longer connected. Repair or replace as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 17 March 2026
Resolution: observed rectification
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2026 Resolved
Starboard fuel tank grounding wire is no longer connected. Repair or replace as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 17 March 2026
Resolution: observed rectification
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2026 Resolved
Forward battery in engine room space was not secure and able to move around. Repair or replace as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 17 March 2026
Resolution: observed rectification
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2026 Resolved
Electrical connection terminal block in steering/fuel tanks space has broken connections and is severely corroded. Repair or replace as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 17 March 2026
Resolution: observed rectification
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2026 Resolved
Conduit containing wires into electrical breaker switch located in port forward engine compartment is not fully seated. Repair or replace as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 17 March 2026
Resolution: observed rectification
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2026 Resolved
A/C condensate drain line is pointed towards battery in forward engine compartment. Repair, rearrange, or replace as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 17 March 2026
Resolution: observed rectification
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2026 Resolved
Fuel emergency shutoff was not labeled. Label as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 17 March 2026
Resolution: observed rectification
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 24 February 2026 Resolved
"No passengers allowed" on upper deck was not labeled. Label as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 17 March 2026
Resolution: observed rectification
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 May 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI observed missing air filter and breathing tube on generator causing oil particulate to accumulate on generator windings and surrounding equipment. Cite: 46 CFR 182.100
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2025
Resolution: Generator air filter and breathing tube installed, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 May 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed the vessel's port sidelight to be extinguished. Vessel is daylight restricted. Cite: 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2025
Resolution: Port sidelight is operational, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 May 2025 Resolved
A vessel of 12 meters or more in length shall be provided with a whistle, a vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle, and a vessel of 100 meters or more in length shall, in addition, be provided with a gong, the tone and sound of which cannot be confused with that of the bell. The whistle, bell and gong shall comply with the specifications in Annex III to these Rules (33 CFR part 86). The bell or gong or both may be replaced by other equipment having the same respective sound characteristics, provided that manual sounding of the prescribed signals shall always be possible. MI observed no sound signaling device on board. Vessel restricted to fair weather. Cite: 33 CFR 83.33(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2025
Resolution: Sound signaling device acquired, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 May 2023 Resolved
Vessel does not have an interconnected smoke detection and alarm system. Vessels on a Coastwise or Oceans route must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. 46 CFR 181.405(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 June 2023
Resolution: Received objective evidence that vessel has installed an interconnected fire detection system.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2023 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel's Safety Radiotelephony Certificate was expired. 47 CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 July 2024
Resolution: Radiotelephony certificate verified up to date and accurate.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 May 2022 Resolved
A vessel not required to have a power driven fire pump must have at least three 2 1/2 gallon buckets, with attached lanyard. Vessel was missing fire buckets. Replace fire buckets.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2022
Resolved 1 June 2022
Resolution: Received documentary evidence of fire buckets placed on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2022 Resolved
A vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Vessels alarm panel did not show visual alarm. Show proper operation of the alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2022
Resolved 16 June 2022
Resolution: Photos received, see docs.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 5 August 2021 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The grab line webbin on one of the life floats is worn and needs to be replaced. Replace webbing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2021
Resolved 2 September 2021
Resolution: Vessel rep submitted objective evidence of repairs made to life float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 August 2021 Resolved
A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding are required to have a high level alarm. The engine room high level alarm has a broken bracket. Replace float switch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2021
Resolved 26 August 2021
Resolution: Vessel rep submitted objective evidence to the satisfaction of marine inspector clearing deficiency.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 August 2021 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel IAW its COI. A stringer support in the aft lazarette has deteriorated creating a soft spot on the deck. Repair or replace the deteriorated stringer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2021
Resolved 3 September 2021
Resolution: Owner/operator submitted objective evidence for correction of deficiency to the satisfacton of the MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 August 2021 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel IAW its COI. The ladder leading to the wheelhouse has a broken hand rail support. Repair or replace the ladder.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2021
Resolved 26 August 2021
Resolution: Vessel rep submitted objective evidence to the satisfaction of marine inspector clearing deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 May 2020 Resolved
Vessel supervisor required to have 60 minutes of EAP training annually.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2020
Resolved 26 May 2020
Resolution: Supervisor completed required training and submitted proof to [name withheld] resolved.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2020 Resolved
Vessel had exposed wiring in accommodation space. Vessel electrical must be installed and maintained to protect passengers, crew, other persons, and vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2020
Resolved 8 June 2020
Resolution: vessel rep covered exposed wires with cabin light, provided pictures as proof.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 August 2019 Resolved
Nautical charts not up-to-date. Charts must be kept up-to-date. Update charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 15 August 2019
Resolution: Purchased new updated chart
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 August 2019 Resolved
Current tables onboard are not current. Vessel must have updated tidal current tables onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 15 August 2019
Resolution: Printed out up-to-date Tidal Current Tables
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 August 2019 Resolved
Vessel has outdated Coast Pilot. Must have current Coast Pilot onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 8 January 2020
Resolution: Received picture via email
Communications › Alarms/Indicators › High Water Alarm
Issued 2 August 2017 Resolved
Bilge pumps and high water alarms must have operable light and alarm at operating station IAW 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 7 August 2017
Resolution: Connected wire correctly so all lights and alarms function.
Accommodation/Occupational Safety › Ventilation › General
Issued 2 August 2017 Resolved
Provide ventilation for engine room to prevent hazardous condition in accommodation space IAW 46CFR182.430.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 September 2017
Resolved 7 August 2017
Resolution: Added ventilation and connected to automatically shutdown with fire extinguisher.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 2 August 2017 Resolved
Fire extinguisher certificate needs to be attached to extinguisher in the fwd space IAW 46 CFR 176.810.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 7 August 2017
Resolution: Serviced and attached certificate to fire extinguisher.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 2 August 2017 Resolved
Conduct and log monthly test of EPIRB IAW 46 CFR 185.728.
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 7 August 2017
Resolution: Generated log and conducted a monthly test.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 August 2017 Resolved
Replace stern light and FWD mast light lens IAW 46 CFR 183.420 and 33 CFR Part 84.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 October 2017
Resolution: MI witnessed satisfactory operation of nav lights
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 August 2017 Resolved
Provide space to store child life preservers and clearly mark "child" and quantity IAW 46 CFR 185.604 and 46 CFR 180.78.
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 7 August 2017
Resolution: Added plastic box to store life jackets under labeled bench seat.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 2 August 2017 Resolved
Replace retro tape on life floats, life jackets, and life ring IAW 46 CFR 180.70, 46 CFR 180.71, and 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 October 2017
Resolution: Retro tape has satisfactorily been replaced on life jackets, life floats and life ring
Lifesaving › Lifefloat › Paddle
Issued 2 August 2017 Resolved
Tether paddles to life floats IAW 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 October 2017
Resolution: Life float paddles were properly attached to life float
Lifesaving › Lifefloat › Lifeline
Issued 2 August 2017 Resolved
Replace melted/broken strap on life float IAW 46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 October 2017
Resolution: Strap was replaced to the satisfaction of attending MI
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 2 August 2017 Resolved
Vessel must have current Tides and Currents for operating area IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 October 2017
Resolution: Current copy of tide tables was on board the vessel
Engineering › Bilge Water Management System › Piping
Issued 2 August 2017 Resolved
Replace PVC bilge pipes with suitable piping material IAW 46 CFR 182.710.
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 October 2017
Resolution: Bilge piping was satisfactorily replaced IAW 46 CFR 182.530
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 2 August 2017 Resolved
Provide means to seal engine room ventilation during fire IAW 46 CFR 181.400.
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 7 August 2017
Resolution: Added seals to engine room hatches.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 August 2017 Resolved
Repair broken breaker boxs IAW 46 CFR 183.330
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 October 2017
Resolution: Electrical installation was replaced and found to be in satisfactory condition.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 2 August 2017 Resolved
Replace outlet box in engine room that is broken with a hole in the side IAW 46 CFR 183.10-10.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 October 2017
Resolution: Electrical installation was replaced and found to be in satisfactory condition.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 2 August 2017 Resolved
Add crewmember to DAPI program and complete supervisory program IAW 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 October 2017
Resolution: Provided proof of supervisory training
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 August 2017 Resolved
Obtain FCC radio documents, have radios inspected, connect with MMSI/DSC, and retain copy of FCC inspectors report, IAW 47 CFR Part 80.
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 October 2017
Resolution: Provided required radio documentation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 August 2017 Resolved
Splice wire next to microwave in cabinet inside an enclosure IAW 46 CFR 183.10-10.
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 October 2017
Resolution: Resolved to the satisfaction of MI.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 9 August 2016 Resolved
No proof of DAPI enrollment for company. Provide proof of DAPI enrollment for all of company's employees
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 24 August 2016
Resolution: Provided updated roster.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 August 2016 Resolved
EAP training not provided for crew. Provide documentation of completed training.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 24 August 2016
Resolution: Training provided to all crew.
Documentation › Certificates/Documents › FCC SSL
Issued 9 August 2016 Resolved
Original FCC Station license not on board. Provide Station license.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 24 August 2016
Resolution: Provided original copy of document.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 August 2016 Resolved
FCC Safety Radiotelephony certificate expired. Provide current and valid cert.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 18 August 2016
Resolution: Provided current certificate
Documentation › Certificates/Documents › Stability Letter
Issued 9 August 2016 Resolved
Stability letter and emergency instructions not posted at operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 24 August 2016
Resolution: Posted at operating station
Fire Fighting › Means of Escape › Escape Route Signs
Issued 9 August 2016 Resolved
Emergency exit not properly labeled. Label "Emergency Exit, Keep Clear" at exit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 August 2016
Resolved 24 August 2016
Resolution: Escape properly labeled.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.