← All vessels
SEA WAVE
Freight Ship · Ro-Ro Cargo Ship class · Built 1980s · USCG Northeast District (CGD-NE) · Other hulls named SEA WAVE
SEA WAVE is a 1980 freight ship. The Coast Guard has recorded 54 inspections since 1986, most recently in February 2010, along with 35 deficiencies and 9 operational controls.
Records from 1986 to 2010. Most recent: operational control imposed, 27 February 2010.
- Built
- 1980
- Last inspected
- 27 February 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 35 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8014227 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HYH6
264103
Flag
MALTA
—
Maury page id
psix-264103
Inspections, by type
…with no type recorded28
Years with a record
20 calendar years (1986–2010)
The 54 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it27421 - Convention (Subpart B), Gross Ton
27421 - Regulatory (Subpart C or D), Gross Ton
16891 - Regulatory (Subpart C or D), Net Ton
10677 - Dead Weight, Ton
27421 - Regulatory (Subpart C or D), Gross Ton
16891 - Regulatory (Subpart C or D), Net Ton
10677 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 54
27 February 2010
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3686180
19 February 2010
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3682217
18 February 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3681752
16 February 2010
ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3680336
15 February 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3680207
14 February 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3679789
8 February 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3677150
1 January 2009
ISPS III Exam · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3387423
25 November 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3367093
25 November 2008
ISPS I Exam · NPV Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3368784
20 November 2008
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3370574
17 October 2008
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3346697
15 October 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3345502
14 October 2008
Deficiency Check · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3344156
13 October 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3343911
9 October 2008
NPV Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3341362
9 October 2008
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3344524
7 May 2008
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3201043
3 May 2008
ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3196528
26 November 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3104458
14 November 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3098481
13 November 2007
MARPOL Annex I Examination · Random ISPS/MTSA/PSC · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3097515
11 May 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2927918
28 March 2007
MARPOL Annex I Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2897231
27 March 2007
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2895977
20 March 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2891588
24 July 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2723492
6 September 2005
ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2485668
20 July 2005
PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2433454
3 March 2005
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2302767
27 July 2004
ISPS II Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2146886
28 March 2004
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2034348
19 February 2004
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2009116
16 February 2004
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2008104
7 January 2004
Ballast Water Examination · Annual Inspection · Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1977933
21 November 2003
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1953336
17 October 2003
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 1930543
8 October 2003
Re-Inspection · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1923503
7 October 2003
Security Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1923506
12 December 2002
Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1720099
5 July 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 279508
5 January 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 436075
11 March 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 426384
26 December 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 411220
3 February 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 387481
21 April 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 366276
2 April 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 476674
2 July 1990
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 338044
6 February 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 490771
6 June 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 330734
4 April 1988
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 533708
9 October 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 318977
20 August 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 463602
23 April 1986
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 308351
Deficiency record · 35
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 27 February 2010
Resolved
Priming pump for Emergency Fire Pump has water leaking from rear of electric motor casing. Pump was tested and still operating and provides sufficient priming for emergency fire pump. Rectify to the Satisfaction of Class.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 27 February 2010
Resolved
Vessel lost port anchor and approximately 5.5 shots of chain at sea (approximately 1.5 E-SE of Narragansett Bay Pilot [name withheld]). Address to the satisfaction of Class.
Construction/Loadline › Hull › Hull Plating
Issued 16 February 2010
Resolved
0938 - Inset in the hull approximately 10 meters forward of the load line. Inset is approximately 6 ft wide by 6 ft tall with an indent of approximately 6 inches. RO to attest to inset structural integrity.
SOLAS 2004 Ch. 1 Reg. 11
Fire Fighting › Fire Main › Condition
Issued 16 February 2010
Resolved
0720 - Firemain leak in the starboard paint locker due to missing sprinkler head. Vessel to replace missing sprinkler head so system may work at designed specifications.
SOLAS 2004 II-2 Reg. 10.2.1.2
Electrical › Lighting (service) › Lighting Fixture
Issued 16 February 2010
Resolved
0950 - The explosion proof ligh located in the starboard paint locker is missing caulking resulting in the fixture not meeting its designed specifications of not allowing flammable mixtures to ignite.
SOLAS 2004 II-I Reg 45.10
Communications › Internal Communications System › Sound-powered Telephone
Issued 16 February 2010
Resolved
2015 - Vessel must have a fixed means of communication between the steering gear room and bridge. The speakers are currently inoperable.
SOLAS 60 Reg. 29
Construction/Loadline › Structures › Superstructure
Issued 16 February 2010
Resolved
1270 - Openings on the superstructure above the main deck shall be weatherttight. Doors leading to the steering gear will not close properly with multiple dogs inoperable.
ICLL Ch. II Reg 12
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 16 February 2010
Resolved
0710 - Structural fire protection in the CO2 stowage room is wasted making the boundary potentially ineffective.
SOLAS 2004 Ch. II-2 Reg. 9
SOLAS 60 Reg. 40
Operations/Management › Drills/Instruction › Fire
Issued 16 February 2010
Resolved
0920 - The current approved Fire/Safety Plan designates the lifejackets to be stowed at embarkation station. Vessel currently stows lifejackets in crew cabins. Vessel to either update plan or move lifejackets to the approved location.
SOLAS 2004 II-2 Reg 15
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 16 February 2010
Resolved
2055 - Current training plan does not explain in detail donning of lifejackets. Current poster posted for lifejacket donning is outdated. Vessel to update plan to give vessel specifics on life-saving appliances.
SOLAS 2004 III Reg. 35
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 1 January 2009
Resolved
Alterations were made in the discharge piping of the OWS. A tie in for recirculation and testing after the 3 way valve was installed following a PSC exam in Belgium. This required changes to the piping plan for which approval by the Administration could not be verified. Verify to the satisfaction of Class. MARPOL (06 CONS) I/14
Engineering › Fuel Oil Service System › Piping
Issued 1 January 2009
Resolved
Fuel Oil drain line (lower deck) on STBD Aft section of Main Engine is potentially blocked. A threaded drain cock is left open, allowing fuel oil (diesel) to drip on deck, creating an unsafe condition. SOLAS (04 CONS) I/11(a) and (04 CONS) II-1/26.1 Correct to the satisfaction of Class.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 1 January 2009
Resolved
Hydraulic Motor on STBD anchor windlass has a cracked casing. Windlass failed when vessel attempted anchor retrieval in preparation to transit Narragansett Bay. Temporary repairs were made. Permanent repairs must be made to the satisfaction of Class. SOLAS (04 CONS) I/11 and 33 CFR 164.11(c).
Fire Fighting › Means of Escape › Number
Issued 1 January 2009
Resolved
EEBD's were not readily available for use in the following locations: 1) Engine room port side lower deck on ladder FWD of OWS. 2) Boiler deck on port ladder aft of boiler. Both of these devices were not adequately charged. SOLAS (04 CONS) II-2/13.4.3.1 Correct to the satisfaction of Class.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 October 2008
Resolved
10CM INOP
Construction/Loadline › Structures › Door
Issued 9 October 2008
Resolved
Starboard stern ramp damaged. Watertight integrity uncertain.
Construction/Loadline › Structures › Door
Issued 9 October 2008
Resolved
Starboard stern ramp not fit for cargo operations. Permanent repairs to ramp and associated equipment required prior to use for cargo operations. (NKK class survey report extended requirement to be completed by end of November 2008, see activity # 3341362 for details).
Construction/Loadline › Structures › Door
Issued 9 October 2008
Resolved
Operationally test port side winch to the satisfaction of attending surveyor prior to use (hydraulic control is common to port and stbd cargo ramp lowering cable drums)
Construction/Loadline › Hull › Side Shell
Issued 28 March 2007
Resolved
Hull Fractured approximately 2'' and 3'' at the forward lower cornor of the diagonal section that connects the transom to the side shell. 70a
Documentation › Logs/Records › Oil Record Book
Issued 28 March 2007
Resolved
Comence making the entries under code C-11-1 and 2 in the Oil record book. 60a
MARPOL 73/78 I App. III
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 March 2007
Resolved
Maintain a tank level log for all of the tanks so the oncoming watch understands the condition of the vessel. 60a
STCW 95 A-VIII 4-2
Engineering › Feedwater/Condensate Water System › Tank
Issued 28 March 2007
Resolved
Renew water heater tank where the welds have repeated fractures. 70a
ILO 147
Fire Fighting › Means of Escape › Doorways
Issued 28 March 2007
Resolved
Remove hold backs and make A-60 doors from engine room, upper, to accommodation self close. 70a
Engineering › Bilge Water Management System › Piping
Issued 27 March 2007
Resolved
Overboard line to OWS has a small hole. Also address the drip line that is connected to the overboard line to the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 27 March 2007
Resolved
Sewage collection tank has visible holes leaking out of the side shell.
Operations/Management › Drills/Instruction › Fire
Issued 24 July 2006
Resolved
Vessels crew failed to complete a proper fire drill. Crew responded with empty SCBA's, fire team was not fully outfitted in firemans outfitt and crew failed to demonstrate proper technique when responding to the fire. SOLAS 2004 CONS. III/19.3.4
70a - Satisfaction of Classification Society
Operations/Management › Drills/Instruction › Fire
Issued 24 July 2006
Resolved
Vessels crew could not properly operate emergency fire pump to provide two jets of water). Emergency Fire Pump was found to be fully operational yet crew lacked knowledge on how to properly charge fire main using emergency fire pump. At the end of the inspection the crew demonstrated that they could provide to jets of water. SOLAS 2004 CONS. IX/3.1 ISM Code Reg. 8.
70b To the Administrati
Fire Fighting › Firemans Outfit
Issued 16 February 2004
Resolved
Vessel could not produce any satisfactory and complete fire suits as required by SOLAS 74/78 II-2; 17.3.
Vessel must provide (2) Satisfactory Fireman's Suits prior to departing this port (WUT Tacoma, WA) to the satisfaction of the USCG. LEGACY COMPONENT DESC: Protective Clothing
Operations/Management › Drills/Instruction
Issued 7 January 2004
Resolved
Abandon Ship drill was not conducted for safety concerns due to night boarding. Drills should be conducted at next US port. LEGACY COMPONENT DESC: Abandon Ship
Operations/Management › Drills/Instruction
Issued 7 January 2004
Resolved
Fire drill was not conducted for safety concerns due to night boarding. Fire drill should be conducted at next US port. LEGACY COMPONENT DESC: Fire
Fire Fighting
Issued 5 July 2000
Resolved
Prove proper operation of emergency fire pump to the satisfaction of Class and U.S. Coast Guard.
Navigation
Issued 11 March 1999
Resolved
VESSEL'S LIGHT LISTS, U.S. COAST PILOT BOOKS, AND SEVERAL CHARTS WERE NOT CURRENTLY CORRECTED. VESSEL MUST CORRECT CHARTS AND PUBS UP-TO-DATE PRIOR TO DEPARTURE-11MAR99.
Documentation
Issued 6 June 1989
Resolved
A VIO OF 33CFR155.750 IN THAT THE OTP REQ. BY 33CFR155.720 WERE INCOMPLETE IN THAT THEY DIDN'T CONTAIN ANYTHING EXCEPT LINE DIAGRAM/LOCATION OF SHUT OFF VALVES & # OF PERSONS REQ. ON DUTY DURING XFER OPS.
Documentation
Issued 6 June 1989
Resolved
A VIO OF 33 CFR 156.170 IN THAT THE EQUIPMENT TEST & INSPECTIONS REQ. BY 33 CFR 156.170(F)(2) WERE NOT CONDUCTED BY THE VSL.
Navigation
Issued 9 October 1987
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE U.S. CHART 12277,USED BY THE VSL, WAS NOT CORRECTED TO NTM 38/84,WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM CHESAPEAKE AND DELAWARE CANAL TO BALTIMORE HARBOR. NO FOREIGN EQUIVALENT O/B.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.