Records from 1986 to 2008. Most recent: inspection, 20 October 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
20 October 2008
Administrative Inspection · COC-MODU Renew
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3334992
13 September 2006
COC-MODU Renew
Type not classified · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2779316
25 September 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468247
25 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073135
10 June 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 19409
31 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066355
11 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064317
26 April 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1063063
28 September 2000
Letter of Compliance (Initial/Renewal) · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1418773
6 September 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 824736
21 March 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1047476
3 March 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 815696
21 December 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1468546
7 January 1999
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 810179
6 January 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 810397
27 November 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1400892
22 October 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1440071
15 January 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398592
26 November 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 871813
27 February 1996
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 884461
27 January 1996
Deficiency Check · Letter of Compliance (Initial/Renewal)
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1431594
21 December 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1139753
18 October 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 871514
12 August 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1432846
1 July 1994
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1171751
17 August 1993
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1158299
30 September 1992
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1250786
18 August 1992
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 957031
4 January 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 151923
16 October 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1250094
6 September 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1311162
2 August 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1000475
27 September 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 915728
8 August 1990
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1211875
23 August 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1220004
12 August 1989
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1219239
12 August 1988
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1352043
15 October 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016030
14 August 1987
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013100
15 April 1987
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1330579
5 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006463
22 December 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002775
3 June 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307462
16 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295855
17 January 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1304452
Deck/Cargo
Issued 25 September 2001
Resolved
C/R WASTED DRILL WATER PIPING AND DEEP WELL PIPING IN SHAKER PIT ROOM.
Condition: Unknown
Due 1 October 2001
Resolved 1 October 2001
Electrical
Issued 28 September 2000
Resolved
Make permanent repairs to electrical wiring in the mud pit room.
Condition: Unknown
Due 29 September 2000
Resolved 29 September 2000
Electrical
Issued 28 September 2000
Resolved
Make permanent repairs to electrical wiring on the drill floor.
Condition: Unknown
Due 29 September 2000
Resolved 29 September 2000
Fire Fighting
Issued 28 September 2000
Resolved
Install general alarm in mud pit room and prove proper operation of generalalarm throughout the vessel.
Condition: Unknown
Due 29 September 2000
Resolved 29 September 2000
Engineering
Issued 28 September 2000
Resolved
Properly wire the lube oil pump switch.
Condition: Unknown
Due 29 September 2000
Resolved 29 September 2000
Fire Fighting
Issued 28 September 2000
Resolved
Install fire alarm bell in aft store room, aft mechanic shop and install visual and audible alarm on drill floor.
Condition: Unknown
Due 26 October 2000
Resolved 26 October 2000
Deck/Cargo
Issued 21 December 1999
Resolved
MAKE REPAIRS TO CLEATS/BITS. BOTH BITS LOCATED AFT OF HOUSE. REPAIRS AND TEST TO BE TO THE SATISFACTON OF CLASS.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Construction/Loadline
Issued 21 December 1999
Resolved
REPLACE MISSING STUDS FOR TANK MANWAY COVERS.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Electrical
Issued 21 December 1999
Resolved
REPLACE JUNCTION BOXES AT SHALE SHAKER DECK.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Lifesaving
Issued 21 December 1999
Resolved
PRIOR TO DRILLING UNIT GOING INTO OPERATION FIRE AND BOAT DRILLS TO BE WITNESSED BY CG MARINE INSPECTOR.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Electrical
Issued 21 December 1999
Resolved
REPAIR BROKEN SWITCH LOCATED IN MUD PIT ROOM.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Construction/Loadline
Issued 21 December 1999
Resolved
CROP AND RENEW BILGE OVERBOARD LINE AT SOFT PATCH LOCATED GENERATOR ROOM
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Electrical
Issued 21 December 1999
Resolved
MAKE REPAIRS TO EXHAUST LEAK ON EXHAUST LINE FOR MAIN SHIP GENERATOR PRIME MOVER. LEAK LOCATED IN BATTERY ROOM.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Lifesaving
Issued 27 November 1998
Resolved
CONDUCT UNDER LOAD RELEASE GEAR TEST OF BOTH LIFEBOATS.
Condition: Unknown
Due 27 November 1998
Resolved 27 November 1998
Lifesaving
Issued 27 November 1998
Resolved
PROVIDE 8 PARACHUTE FLARES FOR STARBOARD LIFEBOAT.
Condition: Unknown
Due 27 November 1998
Resolved 27 November 1998
Documentation
Issued 27 November 1998
Resolved
PROVIDE COPY OF COMPLETED IOPP AND PANAMANIAN MODU SAFETY CERTIFICATE TO [name withheld].
Condition: Unknown
Due 27 November 1998
Resolved 27 November 1998
Documentation
Issued 27 November 1998
Resolved
PROVIDE ABS CLASS SURVEY REPORT CLEARING OUTSTANDING REQUIREMENTS OF CLASS REPORT HS26474 DATED 10OCT98.
Condition: Unknown
Due 27 November 1998
Resolved 27 November 1998
Lifesaving
Issued 22 October 1998
Resolved
PROVE OPERATION OF INTRINSICALLY SAFE OUTLET COVERS, WHERE SPRUNG, IN MUD PIT & DRILL FLOOR.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Engineering
Issued 22 October 1998
Resolved
PROVIDE STANDARD INTERNATIONAL DISCHARGE CONNECTION IAW IOPP REQUIREMENTS.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Engineering
Issued 22 October 1998
Resolved
PROVIDE FUEL TRANSFER HOSE HYDRO
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Documentation
Issued 22 October 1998
Resolved
PROVIDE ABS CLASS SURVEY REPORT CLEARING OUTSTANDING REQUIREMENTS OF CLASS REPORT HS26474 DATED 10OCT98.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Engineering
Issued 22 October 1998
Resolved
LABEL STBD FUEL TANK EMERGENCY SHUT OFF VALVES.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Engineering
Issued 22 October 1998
Resolved
PROVIDE CAPS ON DRAINS FOR FUEL, L.O. AND HYDRAULIC OIL TANKS.
Condition: Unknown
Due 27 October 1998
Resolved 27 October 1998
Electrical
Issued 22 October 1998
Resolved
LABEL EMERGENCY SHUT DOWN FOR THE AIR COMPRESSOR FOR THE STANDBY GENERATOR.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Electrical
Issued 22 October 1998
Resolved
LABEL BREAKERS IN PANELS 120/208 ABOVE REACH ROD WHEEL HANDLES FOR THE STBDFUEL TANK.
Condition: Unknown
Due 27 October 1998
Resolved 27 October 1998
Electrical
Issued 22 October 1998
Resolved
REPAIR EXAUST LEAK ON THE STBY GENERATOR.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Electrical
Issued 22 October 1998
Resolved
REPAIR SHUTDOWN ON THE STBY GENERATOR SO THAT GENERATOR WILL COMPLETELY SHUTDOWN AND NOT IDLE.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Electrical
Issued 22 October 1998
Resolved
REPLACE SPRING LOADED CAP OVER 480V OUTLET IN THE MUD PITS.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Accommodation/Occupational Safety
Issued 22 October 1998
Resolved
REPLACE UPV UNDER RIG FLOOR.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Accommodation/Occupational Safety
Issued 22 October 1998
Resolved
REPLACE 150# SAFETY VALVE ON THE PRESSURE VESSEL NEXT TO THE STBY GENERATOR.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Engineering
Issued 22 October 1998
Resolved
ENSURE THAT TRANSFER HOSE IS LABELED FO SERVICE.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Engineering
Issued 22 October 1998
Resolved
PROVIDE A STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Lifesaving
Issued 22 October 1998
Resolved
CONDUCT RELEASE GEAR TEST ON BOTH L/Bs
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Lifesaving
Issued 22 October 1998
Resolved
PROVIDE LANTERN & 1 PARACHUTE FLARE FOR STBD L/B
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Navigation
Issued 22 October 1998
Resolved
REMOUNT STBD NAVIGATION RUNNING LT
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Lifesaving
Issued 22 October 1998
Resolved
INSTALL AFT SIDE LIMIT SWITCH ON PORT L/B & PROVE PROPER OPERATION
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Lifesaving
Issued 22 October 1998
Resolved
STENCIL RIG NAME ON PORT L/B
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Navigation
Issued 22 October 1998
Resolved
REMOVE EXCESSIVE PAINT OVERSPRAY FROM STERN LT
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Navigation
Issued 22 October 1998
Resolved
ADJUST & PROVE PROPER OPERATION OF FOGHORN
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Lifesaving
Issued 22 October 1998
Resolved
PROVIDE 2 FLARES IN WHEELHOUSE
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Electrical
Issued 22 October 1998
Resolved
PROVIDE E-LIGHT FRO LADDER WELL THAT LEADS UP TO GALLEY
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Lifesaving
Issued 22 October 1998
Resolved
PROVIDE 100 PSI RELIEF VALVE FOR HOT WATER HEATER IN GALLEY.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Accommodation/Occupational Safety
Issued 22 October 1998
Resolved
PROVE PROPER OPERATION OF SHOWER DRAIN & SINK IN HOSPITAL TREATMENT ROOM.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Fire Fighting
Issued 22 October 1998
Resolved
PROVIDE 6 YR SERVICING ON FIRE EXTINGUISHER #77
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Fire Fighting
Issued 22 October 1998
Resolved
REPLACE BENT VALVE STEM FOR INTERNATIONAL SHORE CONNECTION AT STATION #12
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Lifesaving
Issued 22 October 1998
Resolved
LABEL GENERAL ALARM IN SHALE SHAKER HOUSE
Condition: Unknown
Due 27 October 1998
Resolved 27 October 1998
Documentation
Issued 22 October 1998
Resolved
PROVIDE COPY OF ENDORSED IOPP & MODU CODE CERTIFICATE TO [name withheld]
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Fire Fighting
Issued 22 October 1998
Resolved
PROVIDE CLEAR, LEGIBLE INSTRUCTIONS FOR MANUAL OPERATION OF FIXED CO2 SYSTEM AT BOTTLE BANK
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Lifesaving
Issued 22 October 1998
Resolved
REMOUNT H2S SENSOR IN MUD PIT ROOM
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Fire Fighting
Issued 15 January 1997
Resolved
HYDROSTATIC TEST ALL FIXED CO2 CYLINDERS.
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Documentation
Issued 15 January 1997
Resolved
PROVIDE COPIES OF ENDORSED LOADLINE CERTIFICATE, MODU SAFETY EQUIPMENT CERTIFICATE AND INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE.
Condition: Unknown
Due 16 January 1997
Resolved 16 January 1997
Navigation
Issued 15 January 1997
Resolved
REPAIR FOG HORN.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Lifesaving
Issued 15 January 1997
Resolved
CONDUCT LINETHROWING APPLIANCE TRAINING. IMPLEMENT POLICY TO CONDUCT AND LOG QUARTERLY LINETHROWING APPLIANCE TRAINING.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Electrical
Issued 15 January 1997
Resolved
REPLACE LIGHTS ON ALARM PANEL AND ADJUST OVERSPEED SHUTDOWN ON STANDBY GENERATOR.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Engineering
Issued 15 January 1997
Resolved
HYDROSTATICALLY TEST AND PROPERLY LABEL TWO FUEL TRANSFER HOSES.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Engineering
Issued 15 January 1997
Resolved
REMOVE PETCOCKS FROM FUEL FILTERS.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Fire Fighting
Issued 15 January 1997
Resolved
CROP AND RENEW FIRE MAIN PIPING IN ACCORDANCE WITH ABS RECOMMENDATIONS.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Accommodation/Occupational Safety
Issued 15 January 1997
Resolved
PLACE 100 PSI SAFETY RELIEF VALVE ON ONE HOT WATER HEATER.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Lifesaving
Issued 15 January 1997
Resolved
EQUIP LIFEBOATS IN ACCORDANCE WITH SOLAS, CHAPTER III AND REPAIR/REPLACE EQUIPMENT NOTED ON WORKLIST ISSUED 15JAN97 (REF: MINS MI97000041).
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Documentation
Issued 27 January 1996
Resolved
PROVIDE COPIES OF FOLLOWING FINAL CERTIFICATES: IMO MODU CODE, IOPP, AND LOADLINE.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Electrical
Issued 12 August 1994
Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR PRIME MOVER ALARMS AND SHUTDOWNS.
Condition: Unknown
Due 30 August 1994
Resolved 15 November 1994
Electrical
Issued 12 August 1994
Resolved
PROVE PROPER OPERATION OF GENERATOR PRIME MOVER ALARMS AND SHUTDOWNS.
Condition: Unknown
Due 30 August 1994
Resolved 15 November 1994
Lifesaving
Issued 12 August 1994
Resolved
PROVIDE DOCUMENTATION INDICATING LIFEBOAT AND LIFERAFT FALLS HAVE BEEN RENEWED WITHIN FIVE YEARS OR RENEW FALLS ON LIFEBOAT AND LIFERAFT DAVITS.
Condition: Unknown
Due 30 August 1994
Resolved 15 November 1994
Lifesaving
Issued 18 August 1992
Resolved
UPON ACTIVATION OF RIG CONDUCT FIRE AND ABANDON DRILLS, FORWARD COPY OF LOCTO [name withheld].
Condition: Unknown
Due 18 August 1992
Resolved 18 August 1992
Electrical
Issued 18 August 1992
Resolved
REPLACE JUNCTION BOXES AND INSPECTION PLATES ON ALL JACK HOUSE VENTS AND PORT MUD PIT SUPPLY VENT.
Condition: Unknown
Due 18 August 1992
Resolved 18 August 1992
Accommodation/Occupational Safety
Issued 2 August 1991
Resolved
PROVIDE NAMEPLATE FOR DEMCO MSD
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Electrical
Issued 2 August 1991
Resolved
PROVE OPERATION OF #3 GENERATOR OVERSPEED, LOW L/O & REVERSE POWER TRIPS
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Construction/Loadline
Issued 2 August 1991
Resolved
INSTALL NAMEPLATE SHOWING HOMEPORT
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Electrical
Issued 2 August 1991
Resolved
PROVE OPERATION OF EM. GEN OVERSPEED.
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Electrical
Issued 2 August 1991
Resolved
PROVE PROPER OPERATION OF #2 GEN REVERSE POWER RELAY ON THE LIGHT.
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Electrical
Issued 2 August 1991
Resolved
PROVE PROPER OPERATION OF #1 EMO LOW LUBE OIL TRIP
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Lifesaving
Issued 2 August 1991
Resolved
REPAIR/ RENEW FORWARD LIMIT SWITCH ON #2 LIFEBOAT
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Engineering
Issued 2 August 1991
Resolved
PROVE PROPER OPERATION OF ALL PRESSURE VESSEL RELIEF VALVES
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Engineering
Issued 2 August 1991
Resolved
PRESENT FOR INSPECTION ALL AIR RCVRS
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Deck/Cargo
Issued 2 August 1991
Resolved
PROVIDE FOR INSPECTION THE OIL RECORD BOOK
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Lifesaving
Issued 2 August 1991
Resolved
PROVIDE SIGNAL MIRROR FOR #2 LIFEBOAT.
Condition: Unknown
Due 2 August 1991
Resolved 2 August 1991
Electrical
Issued 8 August 1990
Resolved
PROPERLY SUPPORT AND CLAMP CABLES AT NO. 2 CAPSULE DAVIT RUNNING TO WINCH MOTOR AND RUNNING LIGHT.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Accommodation/Occupational Safety
Issued 8 August 1990
Resolved
MAKE AVAILABLE FOR TESTING THE RELIEF VALVES ON THE FOLLOWING PRESSURE VESSELS: FIVE (5) P-TANKS, RIG AIR, DRILL FLOOR AIR, AND EMERGENCY GENERATOR START AIR.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Fire Fighting
Issued 8 August 1990
Resolved
CONDUCT HYDROSTATIC TESTING OF CO2 PORTABLE FIRE EXTINGUISHERS WITH LAST HYDROSTATIC TEST DATES OF OVER FIVE (5) YEARS.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Electrical
Issued 8 August 1990
Resolved
PROVIDE GUARD TO THE EXPLOSION PROOF LIGHT IN THE MUD PIT ROOM.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Electrical
Issued 8 August 1990
Resolved
MAKE PROPER REPAIRS TO THE EMERGENCY GENERATOR LOW LUBE OIL SHUTDOWN AND PROVE PROPER OPERATION.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Lifesaving
Issued 8 August 1990
Resolved
REPAIR CABLE HOUSINGS FOR DAVIT LAUNCHED LIFERAFT BRAKE RELEASE CABLES AND COLOR CODE HANDLES IAW INSTRUCTIONS AND PLACE YELLOW MARK ON CABLE AND DAVIT IAW INSTRUCTIONS.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Electrical
Issued 8 August 1990
Resolved
MAKE REPAIRS TO EXPOSED WIRING IN #1 TOILET & SHOWER ROOM IN OVERHEAD AND HEATER UNIT ON WALL.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Electrical
Issued 8 August 1990
Resolved
INSTALL BULB IN GROUND DETECTION PANEL ON EMERGENCY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Electrical
Issued 8 August 1990
Resolved
MAKE REPAIRS TO THE #1 MAIN GENERATOR LOW LUBE OIL SHUTDOWN.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Lifesaving
Issued 8 August 1990
Resolved
PROVIDE PROOF OF THE INSPECTION OF LIFERAFT #5 S/N: 20MMUS7 LOT 14 WHICH WAS LAST TESTED 6/89.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Lifesaving
Issued 8 August 1990
Resolved
PROVIDE HYDROSTATIC RELEASES ON LIFERAFTS #3 AND #4 AND PROVIDE PROOF OF TESTING WITHIN THE LAST YEAR.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Electrical
Issued 8 August 1990
Resolved
MAKE PROPER REPAIRS TO AND PROVE PROPER OPERATION OF THE EMERGENCY GENERATOR HI TEMPERATURE ALARM AND SHUTDOWN AND MARK THE EMERGENCY FUEL SHUTOFF.
Condition: Unknown
Due 8 August 1990
Resolved 8 August 1990
Accommodation/Occupational Safety
Issued 12 August 1989
Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION THE DRILL FLOOR AND SHIP'S SERVICE AIR RECEIVERS, AND TEST ASSOCIATED RELIEF VALVES.
Condition: Unknown
Due 12 August 1989
Resolved 12 August 1989
Lifesaving
Issued 12 August 1989
Resolved
SERVICE AND REINSTALL ON BOARD THE NO.3 DAVIT-LAUNCHED LIFERAFT.
Condition: Unknown
Due 12 August 1989
Resolved 12 August 1989
Fire Fighting
Issued 12 August 1989
Resolved
HYDROTEST NITROGEN CYLINDERS FOR BOTH HELODECK 150 LB. SEMI-PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 12 August 1989
Resolved 12 August 1989
Lifesaving
Issued 12 August 1989
Resolved
REPLACE OR SERVICE, AND THEN REINSTALL THE HYDROSTATIC RELEASE FOR THE NO.5LIFERAFT.
Condition: Unknown
Due 12 August 1989
Resolved 12 August 1989
Lifesaving
Issued 12 August 1989
Resolved
PROVIDE A HYDROSTATIC RELEASE FOR LIFERAFT NO.6 AND PROVIDE PROOF OF ANNUALTESTING.
Condition: Unknown
Due 12 August 1989
Resolved 12 August 1989
Lifesaving
Issued 12 August 1989
Resolved
REPLACE INTERIOR LIGHT, GUARD AND BATTERIES ON LIFEBOAT NO. 2.
Condition: Unknown
Due 12 August 1989
Resolved 12 August 1989
Lifesaving
Issued 14 August 1987
Resolved
REPAIR HYDRAULIC LEAK IN STARTING SYSTEM OF #2 LIFESAVING CAPSULE.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Fire Fighting
Issued 14 August 1987
Resolved
PROVIDE A FIRE HYDRANT FOR FIRE STATION #1.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Lifesaving
Issued 14 August 1987
Resolved
PROVIDE TOOL KITS FOR LIFEBOATS #1 AND #3 TO COMPLETE REQUIRED EQUIPMENT INVENTORY.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Lifesaving
Issued 14 August 1987
Resolved
DISCHARGE PRESSURIZED AIR BOTTLE #2 IN #2 LIFEBOAT.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Construction/Loadline
Issued 14 August 1987
Resolved
PROVIDE EVIDENCE THAT A DRYDOCKING OR SPECIAL EXAMINATION IN LIEU OF DRYDOCKING HAS BEEN SATISFACTORILY CONDUCTED.
Condition: Unknown
Due 14 August 1987
Resolved 14 August 1987
Accommodation/Occupational Safety
Issued 16 May 1986
Resolved
OBTAIN AND TEST IN PRESENCE OF A CG MARINE INSPECTOR A RELIEF VALVE FOR THERIG FLOOR AIR RECEIVER EQUIPPED WITH A HAND RELIEVING DEVICE. NVC 4-78 AND 46CFR 54.15-10
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Construction/Loadline
Issued 16 May 1986
Resolved
PAINT THE VESSEL DRAFT MARKS IN A CONTRASTING COLOR TO THE HULL. NVC 4-78 AND 46 CFR 108/661
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986