MAURY USCG vessel records Sign in
← All vessels

CAPE LOBOS

CAPE LOBOS is a 1973 freight ship. The Coast Guard has recorded 103 inspections since 1985, most recently in August 2018, along with 167 deficiencies, 1 operational control and 1 casualty investigation in 2003.

Records from 1985 to 2018. Most recent: inspection, 14 August 2018.

Built
1973
Last inspected
14 August 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7216854 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
264193
Flag
UNITED STATES
—
Maury page id
psix-264193

Inspections, by type

…with no type recorded29
Years with a record 21 calendar years (1985–2018)
The 103 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it15005 - Regulatory (Subpart C or D), Gross Ton
22286 - Convention (Subpart B), Gross Ton
10164 - Regulatory (Subpart C or D), Net Ton
7283 - Convention (Subpart B), Net Ton
20544 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KEBAMMSI not assigned · expired · compulsorily equipped · granted 30 November 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NITA E Towing Vessel · MISLE 87953 · 22 March 1993 · activity 15761DM 3027 Freight Barge · MISLE 202401 · 22 March 1993 · activity 15761

Inspection history · 103

14 August 2018 Load Line/Change of Employment
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6511696
7 August 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2738777
11 July 2006 Administrative Inspection
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2710668
28 February 2006 MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2593095
19 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2496213
19 September 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2496232
29 March 2005 Annual Inspection · MTSA/ISPS Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2321953
22 November 2004 MTSA/ISPS Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2247349
28 June 2004 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2113581
18 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2102820
13 April 2004 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2038592
18 February 2004 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2008567
28 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995693
29 September 2003 Internal Structural Exam · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1920560
15 September 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1905446
29 July 2003 Drydock Extension
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1856271
18 March 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1758883
17 March 2003 Security Inspection · Administrative Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1758399
1 March 2003 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1751747
1 March 2003 Deficiency Check · Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1752386
21 February 2003 COI Inspection · Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1748494
5 August 2001 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1068853
8 January 2001 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 825332
3 October 2000 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1056227
22 November 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 28315
22 November 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 799210
26 October 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 458529
27 September 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1039661
5 August 1999 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1411944
3 March 1999 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 807294
13 November 1998 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 805621
4 September 1998 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 797107
2 September 1998 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 797840
28 July 1998 Hull Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1372466
27 July 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 796264
8 July 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1386292
21 May 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1126456
22 January 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 778924
18 December 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 784173
30 September 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1467028
26 September 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1116128
18 June 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1383586
5 May 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1428754
9 April 1997 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1101593
25 February 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1097024
30 September 1996 Examination of Repairs
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1392478
30 May 1996 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1085395
3 April 1996 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1079533
8 January 1996 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 879588
24 August 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1190272
18 August 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1188999
10 August 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1182409
26 July 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1191346
2 June 1995 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1185608
9 January 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1137130
2 December 1994 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1181559
11 September 1994 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 867219
7 September 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 863985
2 September 1994 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1172063
27 July 1994 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 870412
25 July 1994 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1409162
13 April 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 365980
8 April 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 860141
24 March 1994 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1166839
4 March 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 853315
19 July 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 143225
25 May 1993 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1356336
22 March 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 15761
18 November 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1136592
26 May 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1269340
4 March 1992 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 961617
3 February 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 125127
5 January 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1142118
5 January 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1143247
30 October 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 175655
15 July 1991 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1248282
3 May 1991 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 927504
3 February 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 932235
29 November 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1231435
18 October 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223889
17 October 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 454504
17 October 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927354
20 September 1990 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1241039
31 August 1990 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 925045
20 August 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1233775
16 August 1990 Excursion Permit · Re-Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1230030
6 March 1990 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 920910
26 February 1988 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1028082
15 April 1987 Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1027554
5 March 1987 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1014792
18 November 1986 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1311367
27 August 1986 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 992870
20 August 1986 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 451910
18 July 1986 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 452758
25 June 1986 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1302592
2 June 1986 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1298132
8 May 1986 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 534387
8 May 1986 Deficiency Check
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1293913
6 May 1986 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1299034
2 May 1986 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 506561
20 March 1986 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1307546
28 February 1986 Reflagging & Initial Certification
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 991943
5 December 1985 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 996076

Deficiency record · 167

Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 28 February 2006 Resolved
STB loss of power/steering alarm would not sound in the pilot house.
Condition: Unknown
Due 1 April 2006
Resolved 27 September 2010
Resolution: Cleared deficiency due to the length of time passed since the issue date.
Lifesaving › Rocket Parachute Flares › General
Issued 28 February 2006 Resolved
Expired flares for lifeboats.
Condition: Unknown
Due 1 April 2006
Resolved 27 September 2010
Resolution: Cleared deficiency due to the length of time passed since the issue date.
Lifesaving › Lifeboat Equipment › Electric Torch
Issued 28 February 2006 Resolved
Smoke Signals expired and needs replacement.
Due 1 April 2006
Resolved 27 September 2010
Resolution: Cleared deficiency due to the length of time passed since the issue date.
Lifesaving › Buoyant Apparatus › Float Free
Issued 28 February 2006 Resolved
Expired hydrostatic release
Due 1 April 2006
Resolved 27 September 2010
Resolution: Cleared deficiency due to the length of time passed since the issue date.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 29 March 2005 Resolved
Liferafts removed for service
Due 1 May 2005
Resolved 27 April 2005
Resolution: Liferafts installed and made available for inspection
Engineering › Diesel Engine (propulsion-direct drive)
Issued 18 March 2003 Resolved
VESSEL LOST PROPULSION WHILE ENTERING PORT. EFFECT REPAIRS AND PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 March 2003
Resolved 18 March 2003
Resolution: CLASS APPROVED REPAIRS.
Engineering › Shafting/Propeller Arrangements
Issued 1 March 2003 Resolved
Make proper repairs to the port and starboard shaft seal prior to sailing. LEGACY COMPONENT DESC: Stern Gland
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2003
Resolved 7 March 2003
Electrical › Lighting (service)
Issued 28 February 2003 Resolved
Properly mount lighting cables in EOS A/C room.
Action required: 705 - Other - as specified
Due 28 March 2003
Resolved 7 March 2003
Lifesaving › Lifeboat
Issued 28 February 2003 Resolved
Prove proper operation of 2nd brake station on both lifeboats.
Action required: 705 - Other - as specified
Due 28 March 2003
Resolved 17 March 2003
Electrical › Lighting (emergency)
Issued 28 February 2003 Resolved
Prove proper operation of Emergency Lighting on Upper Deck, Starboard side aft near aft stairtower. Three lights are not on the emergency circuit. LEGACY COMPONENT DESC: Lighting Branch Circuit
Action required: 705 - Other - as specified
Due 28 March 2003
Resolved 7 March 2003
Electrical › Lighting (emergency)
Issued 28 February 2003 Resolved
Provide emergency lighting at emergency steering gear motor/pump/station. No light currently exists in this location.
Action required: 705 - Other - as specified
Due 28 March 2003
Resolved 7 March 2003
Documentation › Safety/Response Plans/Programs
Issued 28 February 2003 Resolved
Provide approved fire control plan. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 28 March 2003
Resolved 30 April 2004
Documentation
Issued 5 August 2001 Resolved
COMPLETE SATISFACTORY INSPECTION FOR CERTIFICATION AT NEXT ACTIVATION BUT NO LATER THAN ONE YEAR FROM THE DATE 05AUG01. VESSEL COI WILL BE DEACTIVATED IF REQUIREMENT IS NOT CLEARED BY DUE DATE. NO EXTENTION IS AUTHORIZED.
Condition: Unknown
Due 5 August 2002
Resolved 28 February 2003
Resolution: COI was conducted on 2/28/03.
Engineering
Issued 5 August 1999 Resolved
REPAIR STBD BOAT DECK VENT CLOSURE BELL CRANK.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Navigation
Issued 5 August 1999 Resolved
PROVE PROPER OPERATION OF AFT ANCHOR LIGHT.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Accommodation/Occupational Safety
Issued 5 August 1999 Resolved
CLEAN UP HYDRAULIC FLUID ON DECK AND TIGHTEN LOOSE FITTINGS IN " POTATO ROOM" AFT OF GALLEY.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Accommodation/Occupational Safety
Issued 5 August 1999 Resolved
Repair/replace port/stbd SSG start air safety relief valves. Valves failed to properly releive at set pressure and reset firmly.
Condition: Unknown
Due 11 August 1999
Resolved 1 February 2000
Construction/Loadline
Issued 5 August 1999 Resolved
REPAIR HYDRAULIC LEAKS ON DOOR CYLINDERS ON CARGO HOLD WTD'S 3/4 TWEEN AND 1/2 TWEEN.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Electrical
Issued 5 August 1999 Resolved
Reverse power relay on #1 SSG not working; fails to trip generator off-linewhen reverese power signal received.
Condition: Unknown
Due 11 August 1999
Resolved 1 February 2000
Electrical
Issued 5 August 1999 Resolved
REPLACE MISSING LOWER PANEL ON SPACE HEATER IN AFT CONTROL ROOM.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Navigation
Issued 5 August 1999 Resolved
REPLACE BURNED OUT BULB IN #2 STEERING MOTOR CONTROL PANEL.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Construction/Loadline
Issued 5 August 1999 Resolved
PROVE PROPER OPERATION OF OPEN DOOR INDICATOR ON ALL CARGO HOLD WTD'S.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Construction/Loadline
Issued 5 August 1999 Resolved
REPAIR LOOSE OR TORN GASKETS ON 3/4 LOWER AND 3/4 TWEEN WTD'S.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Lifesaving
Issued 5 August 1999 Resolved
PROVIDE SUFFICIENT PFDS AND IMMERSION SUITS AS REQUIRED BY THE COI.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Electrical
Issued 5 August 1999 Resolved
PROVIDE KNOB FOR LIGHT SWITCH IN FAN SPACE AFT OF GALLEY.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Lifesaving
Issued 5 August 1999 Resolved
PROPERLY STOW COMPRESSED GAS CYLINDERS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Construction/Loadline
Issued 5 August 1999 Resolved
REPAIR OR REPLACE WTD ON ELEVATOR HOUSE #2.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Electrical
Issued 5 August 1999 Resolved
REPLACE WASTED BRACKET FOR 110V OUTLET ADJACENT TO FS#16.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Accommodation/Occupational Safety
Issued 5 August 1999 Resolved
REPAIR OR REPLACE HANDLE AND COLLAR ON TOP OF BOW THRUSTER VENT DOME ON THEFOCSLE.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Fire Fighting
Issued 5 August 1999 Resolved
PROPERLY SECURE FIE MAIN PIPING IN EMERGENCY FIRE PUMP SPACE.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Lifesaving
Issued 5 August 1999 Resolved
PROPERLY SECURE HYDRAULIC FILL HOSE IN FWD CONTROL ROOM.
Condition: Unknown
Due 5 August 1999
Resolved 9 August 1999
Construction/Loadline
Issued 13 November 1998 Resolved
PROVE CLOSURES FOR ELEVATOR FANS 1-4 ARE WATERTIGHT.
Condition: Unknown
Due 27 July 1999
Resolved 28 February 2003
Resolution: MISLE maintenance.
Construction/Loadline
Issued 28 July 1998 Resolved
Prove closures for elevator fans 1-4 are watertight.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Navigation
Issued 28 July 1998 Resolved
Provide current deviation table.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998 Resolved
Provide a means to keep firemens outfit pants up around waist.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998 Resolved
Prove proper operation of stbd lifeboat.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Electrical
Issued 27 July 1998 Resolved
INSTALL 02 AMMETERS FOR THE FORWARD SHELL DOOR AND RAMP TO THE SATISFACTIONOF THE CLASS SOCIETY.
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Electrical
Issued 27 July 1998 Resolved
INSTALL FORWARD CATHODIC PROTECTION SYSTEM TO THE SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 27 July 1998
Resolved 27 July 1998
Construction/Loadline
Issued 5 May 1997 Resolved
REPAIR OR REPLACE NON-POTABLE WATER TANK VENT, STBD AFT.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Lifesaving
Issued 5 May 1997 Resolved
DETERMINE SOURCE OF STANDING WATER IN #1 ELEVATOR HOUSE AND REPAIR OR REPLACE SCUPPER DRAIN PIPING AS NEEDED.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Engineering
Issued 5 May 1997 Resolved
REPAIR EXHAUST LEAKS IN EMERGENCY FIRE PUMP EXHAUST PIPING, LOWER LEVEL BENEATH VENTILATOR AND UPPER LEVEL IWO ELBOWS IN PIPE.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Fire Fighting
Issued 5 May 1997 Resolved
PROVE PROPER OPERATION OF SPRINKLER PUMP IN #4 LOWER HOLD, AND PROVE PROPEROPERATION OF THE SPRINKLER SYSTEM BY DECK.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 5 May 1997 Resolved
REPAIR OR REPLACE THE WEATHER TIGHT DOOR ON THE PORT NAVIGATING BRIDGE DECK.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Navigation
Issued 5 May 1997 Resolved
DERUST AND RENEW FITTINGS FOR THE STERN LIGHT.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 5 May 1997 Resolved
REPAIR OR REPLACE PORT POOP DECK FORE AND AFT WEATHERTIGHT DOORS.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Electrical
Issued 5 May 1997 Resolved
ON ALL EXTERIOR MARINE ELECTRICAL OUTLETS, TIGHTEN FITTINGS AND PROVIDE KEEPERS FOR COVERS.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Electrical
Issued 5 May 1997 Resolved
REPAIR WASTED DECK LIGHT BRACKET TO PORT OF THE STERN LIGHT.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Deck/Cargo
Issued 5 May 1997 Resolved
RENEW GASKETS AND FOUNDATION, AS NEEDED, ON THE PORT AFT RADIO MAST.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 5 May 1997 Resolved
REPAIR OR REPLACE #4C WB STBD TANK VENT.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 5 May 1997 Resolved
CHALK TEST AND RECORD RESULTS FOR EACH WATER TIGHT DOOR, HATCH OR CLOSURE ON ALL WEATHER DECKS. REPAIR, REPLACE OR RENEW FITTINGS AS NEEDED._x001C_
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Accommodation/Occupational Safety
Issued 5 May 1997 Resolved
PROVIDE MOTOR FOR STBD ACCOMODATION LADDERPRIOR TO USE OF LADDER.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Construction/Loadline
Issued 5 May 1997 Resolved
REPAIR LOOSE GASKET IN WTD ON #3/#4 TWEEN DECK CARGO HOLD, AND DETERMINE SOURCE OF HYDRAULIC FLUID LEAK AND REPAIR SAME, UPPER RAM FOR WTD.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Electrical
Issued 5 May 1997 Resolved
RENEW CABLE GUARDS ON #2 AND #3 WINCHES, UPPER DECK FORWARD.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 5 May 1997 Resolved
RENEW GASKETS ON ALL UPPER DECK WATERTIGHT DOORS ABOUT THE HOUSE.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Lifesaving
Issued 5 May 1997 Resolved
REPLACE EPIRB BATTERY PRIOR TO VSL ACTIVATION.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Electrical
Issued 5 May 1997 Resolved
RENEW MOTOR COVER AND JUNCTION BOX COVER FOR GALLEY EXHAUST VENT.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Electrical
Issued 5 May 1997 Resolved
PROVE PROPER OPERATION OF EMERGENCY DIESEL GENERATOR AUTO START FEATURE.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Navigation
Issued 5 May 1997 Resolved
PROVE PROPER OPERATION OF PILOTHOUSE RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Construction/Loadline
Issued 5 May 1997 Resolved
REPAIR OR REPLACE WARPER WTD, STBD SIDE #2 ELEVATOR HOUSE._x001C_
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Fire Fighting
Issued 5 May 1997 Resolved
REPAIR HIHGES AND PROVE PROPER OPERATION OF FIRE SCREEN DOOR ON UPPER DECK IN FWD STAIRWELL.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Accommodation/Occupational Safety
Issued 5 May 1997 Resolved
RENEW COVER FOR GALLEY SUPPLY VENT, BOAT DECK AFT.
Condition: Unknown
Due 18 June 1997
Resolved 19 June 1997
Lifesaving
Issued 30 September 1996 Resolved
VESSEL SHALL NOT OPERATE UNTIL PRIMARY LIFESAVING EQUIPMENT IS PROVIDED IN ACCORDANCE WITH 46 CFR 94.10-10.
Condition: Unknown
Due 30 September 1996
Resolved 8 October 1996
Lifesaving
Issued 30 September 1996 Resolved
VESSEL SHALL CONDUCT SATISFACTORY FIRE AND BOAT DRILLS PRIOR TO ACTIVATION.
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Construction/Loadline
Issued 3 April 1996 Resolved
PROVE PROPER OPERATION OF LOCKING CLEATS FOR LOWER 3/4 WTD AND TWEEN 1/2 WTD.
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Engineering
Issued 3 April 1996 Resolved
PROVIDE ALTERNATE VENTING ARRANGEMENT FOR D.O. BUNKER TANK STBD VENT.
Condition: Unknown
Due 30 May 1996
Resolved 31 May 1996
Electrical
Issued 3 April 1996 Resolved
PROVIDE EMERGENCY LIGHTING FOR THE EMERGENCY FIRE PUMP, LOWER LEVEL OF THE BOW THRUSTER SPACE.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Lifesaving
Issued 3 April 1996 Resolved
MAKE PERMANENT REPAIRS TO THE PORT LIFEBOAT AS SPECIFIED IN THE SCHAT- HARDING SERVICE REPORT DTD 4/9/96.
Condition: Unknown
Due 30 September 1996
Resolved 8 October 1996
Electrical
Issued 3 April 1996 Resolved
REPLACE EXPLOSION PROOF COVER ON OVERHEAD LIGHT IN #3 LOWER CARGO HOLD, STBD CTR JUST AFT OF ELEVATOR
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Lifesaving
Issued 3 April 1996 Resolved
PROVIDE AN ENGINE ALARM, AUDIBLE TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Deck/Cargo
Issued 3 April 1996 Resolved
IN #2 TWEEN CARGO HOLD, PROPERLY SECURE ELEVATOR RETURN SWITCH ON PORT FWD_x001C_STANCHION.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Accommodation/Occupational Safety
Issued 3 April 1996 Resolved
PROVIDE A REPORT FROM AN ASME CERTIFIED PERSON ADDRESSING THE CONTROL AIR RECIEVERS INTERNAL CONDITION PRIOR TO ITS USE.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Electrical
Issued 3 April 1996 Resolved
PROVIDE VISIBLE INDICATOR OF POWER SUPPLY STATUS TO HPU CONTROLLER IN FWD RAMP CONTROL ROOM.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Electrical
Issued 3 April 1996 Resolved
RENEW WASTED STANDPIPE AND ASSOCIATED ELECTRICAL WIRING AT TOP OF THE FWD MAST.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Electrical
Issued 3 April 1996 Resolved
REPLACE WASTED ELECTRICAL OUTLET AT BASE OF MAIN MAST.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Fire Fighting
Issued 3 April 1996 Resolved
PROVE PROPER OPERATION OF THE FIRE DETECTION CONTROL PANEL IN THE P/H.
Condition: Unknown
Due 30 May 1996
Resolved 31 May 1996
Navigation
Issued 3 April 1996 Resolved
PROVE PROPER OPERATION OF STBD B/W GYRO REPEATER.
Condition: Unknown
Due 30 May 1996
Resolved 31 May 1996
Deck/Cargo
Issued 3 April 1996 Resolved
CLEAN HYDRAULIC OIL FM BOW THRUSTER SPACE; PROVE PROPER OPERATION OF HPU SYSTEM AND STORAGE TANK FLOAT SWITCH.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Accommodation/Occupational Safety
Issued 3 April 1996 Resolved
RENEW LADDER FM PORT AFT BOAT DECK TO POOP DECK.
Condition: Unknown
Due 30 May 1996
Resolved 31 May 1996
Accommodation/Occupational Safety
Issued 3 April 1996 Resolved
RENEW CLOSURE DEVICE FOR DOOR FM ENG RM TO PORT GARAGE.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Lifesaving
Issued 3 April 1996 Resolved
PROVIDE A PROFESSIONAL EVALUATION OF THE PHYSICAL CONDITION OF THE PORT (#2) MLB BY A MFRS AUTHORIZED REPRESENTATIVE.
Condition: Unknown
Due 10 April 1996
Resolved 22 April 1996
Electrical
Issued 3 April 1996 Resolved
PROPERLY REMOUNT ELECTRICAL OUTLET STBD POOP DK, BELOW LIFERAFT.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Electrical
Issued 3 April 1996 Resolved
PROPERLY AFFIX COVER AND REPLACE WASTED MOUNT FOR ELECTRICAL JUNCTION BOX ON FWD STBD DAVIT.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Lifesaving
Issued 3 April 1996 Resolved
RENEW WASTED LOCKING PIN PLATE ON STBD FWD DAVIT ARM.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Engineering
Issued 3 April 1996 Resolved
RENEW WASTED FIXED CONTAINMENT FOR "F.O. SETTLING TANK STBD".
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Navigation
Issued 3 April 1996 Resolved
RENEW WATERTIGHT ENTRY FITTING FOR AFT ANCHOR LIGHT.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Deck/Cargo
Issued 3 April 1996 Resolved
PROVE PROPER OPERATION OF TOPSIDE LOCKING CLEATS FOR AFT RAMP.
Condition: Unknown
Due 23 April 1996
Resolved 24 April 1996
Deck/Cargo
Issued 3 April 1996 Resolved
PROVE PROPER OPERATION OF ALL CARGO ELEVATOR INDICATOR LAMPS AND ROTATING BEACONS.
Condition: Unknown
Due 30 September 1996
Resolved 8 October 1996
Construction/Loadline
Issued 10 August 1995 Resolved
MAKE FORWARD PORTION (APPROX 10') OF FORWAED SIDE SHELL DOOR WATERTIGHT.
Condition: Unknown
Due 10 August 1995
Resolved 10 August 1995
Lifesaving
Issued 2 June 1995 Resolved
PROVIDE REQUIRED MEDICAL & FIRST AID SUPPLIES FOR HOSPITAL PRIOR TO ACTIVATION OF THE VESSEL.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Lifesaving
Issued 2 June 1995 Resolved
PROVIDE PROPERLY RATED RELIEF VALVE FOR THE ACCOMODATION SPRINKLER SYSTEM HEAD TANK PRIOR TO ACTIVATION OF THE VESSEL.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Fire Fighting
Issued 2 June 1995 Resolved
PROVE THE OPERATION OF THE FIRE AND SMOKE DETECTION SYSTEM PRIOR TO THE VESSELS ACTIVATION.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Construction/Loadline
Issued 2 June 1995 Resolved
PROVE THE OPERATION OF BOTH FORE AND AFT SIDE SHELL DOORS PRIOR TO ACTIVATION OF THE VESSEL.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Lifesaving
Issued 2 June 1995 Resolved
MAKE REPAIRS TO, AND WEIGHT TEST STBD LIFEBOAT PRIOR TO THE VESSELS ACTIVATION.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Lifesaving
Issued 2 June 1995 Resolved
CONDUCT FIRE AND BOAT DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR PRIORTO THE VESSELS ACTIVATION.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Construction/Loadline
Issued 11 September 1994 Resolved
NO STORAGE OR TRANSITING OF ANY KIND IN AREAS MARKED ON DECK ABOVE ROLL TANKS. TRANSITING ONLY IN AREA BETWEEN AREAS MARKED ON DECK UNTIL ROLL TANKS ARE RERAIRED AS PER CG-835 ITEM D9, ISSUED BY WNCMS CASE MI94022074.
Condition: Unknown
Due 11 September 1994
Resolved 11 September 1994
Electrical
Issued 11 September 1994 Resolved
PROVIDE AUDIBLE AND VISUAL ALARM FOR HIGH JACKET WATER TEMPERATURE ON EMERGENCY GENERATOR TO SOUND IN ENGINEERING CONTROL ROOM.
Condition: Unknown
Due 11 September 1994
Resolved 11 September 1994
Engineering
Issued 7 September 1994 Resolved
RENEW FLEX LINE FOR COOLING ON #1 START AIR COMPRESSOR.
Condition: Unknown
Due 30 September 1994
Resolved 15 September 1994
Lifesaving
Issued 7 September 1994 Resolved
CONDUCT FIRE AND BOAT DRILLS IN THE COMPANY OF A CG MARINE INSPECTOR PRIOR TO ACTIVATION OF VESSEL.
Condition: Unknown
Due 25 May 1995
Resolved 15 September 1994
Engineering
Issued 25 July 1994 Resolved
MAKE OPERATIONAL THE OVERSPEED ALARM FOR THE STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Engineering
Issued 25 July 1994 Resolved
PROVIDE DOCUMENTATION OF THE DEACTIVATION OF THE AUX. BOILER.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Electrical
Issued 25 July 1994 Resolved
PROVE PROPER OPERATION OF THE OVERSPEED SHUTDOWN, LOW LUBE OIL PRESSURE SHUTDOWN AND HIGH JACKET WATER TEMP. ALARM FOR THE EMERGENCY GENERATOR PRIOR TO USE OF THE VESSEL.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Construction/Loadline
Issued 25 July 1994 Resolved
MAKE REPAIRS TO UPPER AND LOWER BALLAST "ROLL" TANKS IN ACCORDANCE WITH THEC. BAXTER AND ASSOCIATES SURVEY OF 3 FEB 1994 WITH ADDITIONAL REPAIRS AS DIRECTED BY MSO WILMINGTON PRIOR TO USE OF THE VESSEL..
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Electrical
Issued 25 July 1994 Resolved
REMOVE ALL SO TYPE ELECTRICAL CABLE FROM VESSEL EXCEPT THAT ATTACHED TO PORTABLE EQUIPMENT.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Fire Fighting
Issued 25 July 1994 Resolved
LOCATE AND REPAIR "FAULT" IN THE #1 ZONE OF THE CARGO DECK SMOKE DETECTION SYSTEM.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Fire Fighting
Issued 25 July 1994 Resolved
RELOCATE FIRE HYDRANTS ON THE MAIN DECK TO ALLOW ACCESS TO ELEVATOR HOUSES WITH THE REQUIRED STREAMS OF WATER FROM A 50' LENGTH.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Fire Fighting
Issued 25 July 1994 Resolved
PROVIDE A SYSTEM DIAGRAM AT THE SMOKE ALARM PANEL LOCATED IN THE ELECTRICALSTOREROOM.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Documentation
Issued 25 July 1994 Resolved
PROVIDE VALID FCC RADIOTELEGRAPH CERTIFICATE.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Documentation
Issued 25 July 1994 Resolved
PROVIDE VALID FCC BRIDGE TO BRIDGE RADIO CERTIFICATE.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Lifesaving
Issued 25 July 1994 Resolved
CONDUCT OPERATIONAL TEST OF BOTH LIFEBOATS IN THE WATER PRIOR TO USE OF THEVESSEL.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Construction/Loadline
Issued 25 July 1994 Resolved
PROVE PROPER OPERATION OF STERN RAMP AND SIDE DOOR.
Condition: Unknown
Due 25 July 1994
Resolved 25 July 1994
Lifesaving
Issued 8 April 1994 Resolved
PROVIDE PROOF OF END FOR ENDING OF LIFEBOAT FALLS OR COMPLETE END FOR ENDING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Engineering
Issued 8 April 1994 Resolved
COMPLETE INTERNAL EXAMINATION AND TEST OF PRESSURE RELIEVING DEVICES ON ALLPRESSURE VESSELS LISTED ON CERTIFICATE OF INSPECTION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Fire Fighting
Issued 8 April 1994 Resolved
PROVIDE EVIDENCE, WITH CG APPROVED PLANS, THAT KIDDE CO2 TIME DELAY COMPONENTS ARE COMPATIBLE WITH INSTALLED ANSUL CO2 SYSTEM TO ENSURE AN EFFECTIVE SYSTEM.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Fire Fighting
Issued 8 April 1994 Resolved
INSTALL HAMMER TO PAINT LOCKER CO2 PULL STATION BOX TO FACILITATE BREAKING GLASS.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Fire Fighting
Issued 8 April 1994 Resolved
PROVIDE APPROVED PIPING PLANS FOR CO2 MANIFOLD SYSTEM THAT ACCEPT 150 LB FITTINGS IN THE 600 LB SYSTEM OR CHANGE FITTINGS.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Construction/Loadline
Issued 4 March 1994 Resolved
MAKE REPAIRS TO UPPER & LOWER, PORT, CENTER, AND STARBOARD CONTROL ROLL (FLUME) TANKS IAW DEFFICIENT/WASTED ITEMS IDENTIFIED IN C. BAXTER AND ASSOC. SURVEY DATED 03FEB94. CARRIAGE OF CARGO ON UPPER CONTROL ROLL TANK CARGO DECK IS PROHIBITED UNTIL SATISFACTORY REPAIRS ARE MADE.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Engineering
Issued 25 May 1993 Resolved
SATISFACTORLY TEST STDB MAIN ENGINE OVERSPEED TRIP AND PROVIDE COAST GUARD INSPECTOR WITH DOCUMENTATION ATTESTING TO SAME.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Construction/Loadline
Issued 25 May 1993 Resolved
DEMONSTRATE PROPER OPERATION OF BILGE ALARM IN BOW THRUSTER COMPARTMENT TO THE SATISFACTION OF ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Electrical
Issued 25 May 1993 Resolved
WIRE LUBE OIL CIRCULATION PUMP MOTORS INTO EXISTING REMOTE SHUT-OFF CIRCUITAND DEMONSTRATE PROPER OPERATION TO ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Navigation
Issued 25 May 1993 Resolved
DEMONSTRATE ACCURATE AND CONSISTANT READINGS BETWEEN RUDDER ANGLE INDICATORS AND FIXED ANGLE INDICATOR ON RUDDER POST IN THE PRESENCE OF USCGINSPECTOR.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Deck/Cargo
Issued 25 May 1993 Resolved
LABEL ALL VENTS ON DECK (REQUIREMENT ORIGINALLY ISSUED BY PATMS ON 04MAR92).
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Electrical
Issued 4 March 1992 Resolved
REPAIR PATCHED PIPING IN SALT WATER COOLING LINES OF THE #2 SHIP SERVICE DIESEL GENERATOR.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Fire Fighting
Issued 4 March 1992 Resolved
MAKE OPERABLE AND RETEST ALL MANUAL PULL FIRE ALARMS.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Electrical
Issued 4 March 1992 Resolved
PLUG OPENINGS IN PANELBOARDS IN MAIN CONTROL.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Fire Fighting
Issued 4 March 1992 Resolved
UPDATE ALL FIRE CONTROL PLANS TO REFLECT PROPER NUMBER OF LIFERAFTS AND NUMBER OF PEOPLE ON LIFEBOATS.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Engineering
Issued 4 March 1992 Resolved
REPAIR THEN CONDUCT ALL OPERATIONAL TESTS AND SHUTDOWNS ON THE STARBOARD MAIN ENGINE.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Engineering
Issued 4 March 1992 Resolved
TEST THE OVERSPEED TRIP ON THE PORT MAIN ENGINE.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Fire Fighting
Issued 4 March 1992 Resolved
REPLACE BURNT OUT BULBS AND RETEST HEAT SENSORS ALARM PANEL ON BRIDGE FOR MACHINERY AND CARGO HOLD SPACES.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Engineering
Issued 4 March 1992 Resolved
OPERATIONALY TEST OR REMOVE WASTE HEAT BOILER.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Electrical
Issued 4 March 1992 Resolved
MAKE REPAIRS THEN RETEST EMERGENCY LIGHTING THOURGHOUT THE VESSEL.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Fire Fighting
Issued 4 March 1992 Resolved
PROVIDE ONBOARD ONE APPROVED FIRE HELMET FOR FORWARD EMERGENCY GEAR LOCKER.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Lifesaving
Issued 4 March 1992 Resolved
PROVIDE ONBOARD ONE BUOYANT ROCKET FOR LINE THROWING GUN.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Deck/Cargo
Issued 4 March 1992 Resolved
LABEL ALL VENTS ON DECK.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Lifesaving
Issued 4 March 1992 Resolved
WEIGHT TEST #1 LIFEBOAT STARBOARD SIDE.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Fire Fighting
Issued 4 March 1992 Resolved
PROVIDE BRACKET FOR PORTABLE FIRE EXTINGUISHER #27.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Accommodation/Occupational Safety
Issued 4 March 1992 Resolved
PROVIDE GREASE FILTER FOR GALLEY RANGE.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Deck/Cargo
Issued 15 July 1991 Resolved
PROVE AFT LOWER TWEEN DECK RAMP DOOR WATERTIGHT.
Condition: Unknown
Due 15 July 1991
Resolved 15 July 1991
Construction/Loadline
Issued 3 May 1991 Resolved
RENEW GASKET FOR AFT LOWER TWEEN DECK RAMP DOOR.
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Deck/Cargo
Issued 20 August 1990 Resolved
A ROVING WATCH SHALL BE MAINTAINED TO CONTINUOUSLY CHECK THE CARGO HOLDS EXHAUST BLOWERS TO INSURE PROPER OPERATION DURING ALL CARGO OPERATIONS. THE WATCH IS TO BE PROVIDED WITH A MEANS FOR CONSTANT COMMUNICATIONS WITH THE ENGINE ROOM AND/OR PILOT HOUSE. CARGO OPS TO CEASE UPON BLOWER FAILURE.
Condition: Unknown
Due 20 August 1990
Resolved 20 August 1990
Deck/Cargo
Issued 20 August 1990 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF THE CARGO HOLD EXHAUST BLOWER FAILUREPANEL (INCLUDING ALARM) LOCATED IN THE ENGINE ROOM. DEFICIENCY D1 ISSUED THIS DATE IS TO REMAIN IN EFFECT UNTIL PROPER OPERATION OF THE ALARM PANEL CAN BE DEMONSTRATED.
Condition: Unknown
Due 20 August 1990
Resolved 20 August 1990
Fire Fighting
Issued 16 August 1990 Resolved
PROVIDE ROVING WATCH FOR CARGO HOLDS DURING TRANSIT FROM HAMPTON ROADS TO JACKSONVILLE FLORIDA 15-18 AUG 1990.
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Fire Fighting
Issued 16 August 1990 Resolved
PROVE PROPER OPERATION OF CARGO HAOLD FIRE DETECTION SYSTEM AUDIBLE ALARM LOCATED ON BRIDGE CONSOLE PRIOR TO LOADING CARGO BUT NOT LATER THAN 22AUG90
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Accommodation/Occupational Safety
Issued 16 August 1990 Resolved
PROVE PROPER OPERATION OF CARGO HOLD LOSS OF VENTILATION ALARMS LOCATED ON ENGINE ROOM CONSOLEPRIOR TO LOADING CARGO BUT NOT LATER THAN 22AUG90
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Construction/Loadline
Issued 16 August 1990 Resolved
PRIOPR TO GETTING UNDERWAY ENSURE PRECAUTIONS HAVE BEEN TAKEN TO SEAL WATERTIGHT BULKHEAD WHERE GASKET IS MISSING ON LOWER AFT TWEEN DECK RAMP.
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Accommodation/Occupational Safety
Issued 16 August 1990 Resolved
PROPERLY DEMONSTRATE THE TYPEII MARINE SANITATION DEVICE PRIOR TO 22AUG90
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Engineering
Issued 16 August 1990 Resolved
REFIT FWD WATER LEVEL INDICATOR SIGHT GLASS TUBE FOR THE OIL FIRED BOILER PRIOR TO 22AUG90
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Engineering
Issued 16 August 1990 Resolved
PROPERLY PACK PORT AND STARBOARD SALT WATER CIRCULATING PUMP PACKING GLANDSPRIOR TO 22AUG90
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Engineering
Issued 16 August 1990 Resolved
INCLUDE IN FUEL OIL TRANSFER PROCEDURES THE PROPER FUELING PROCEDURES FOR THE FOLLOWING DIESEL POWERED UNITS-EMERGENCY GENERATOR, EMERGENCY SPRINKLERPUMP, EMERGENCY STEERING PUMP AND EMERGENCY FIRE PUMP PRIOR TO 22AUG90
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Fire Fighting
Issued 16 August 1990 Resolved
REPAIR OR REPLACE THE EMERGENCY SHUTDOWN FOR THE FUEL OIL PUMPS AND THE MACHINERY SPACE VENTILATION LOCATED ON THE PORT BOAT DECK AT THE MACHINERY SPACE ACCESS PRIOR TO 22AUG90
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Fire Fighting
Issued 16 August 1990 Resolved
MAKE PERMENANT REPAIRS TO AND PROVE PROPER OPRERATION OF ENGINE ROOM EMERGENCY SHUT DOWN SYSTEM IN CONNECTION WITH THE FIXED CO2 SYSTEM. WHILE OPERATION UNDER TEMPORARY REPAIRS A MANNED WATCH SHALL INSURE PROPER OPER- ATION OF SYSTEM. REPAIRS TO BE COMPLETED NOT LATER THAN 20AUG90.
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Navigation
Issued 16 August 1990 Resolved
PROVE PROPER OPERATION OF NAVIGATION LIGHT PANEL LOSS OF POWER ALARM PRIOR TO 22AUG90.
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Navigation
Issued 16 August 1990 Resolved
PROVIDE AUDIBLE AND VISUAL ALARM FOR LOSS OF 24V POWER SUPLY TO EOT SYSTEM AT BRIDGE CONSOLE PRIOR TO 22AUG90.
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Construction/Loadline
Issued 16 August 1990 Resolved
REPLACE MISSING AND DAMAGED PORTIONS OF GASKET FOR MAFT LOWER TWEEN DECK RAMP DOOR PRIOR TO 14FEB91.
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Navigation
Issued 16 August 1990 Resolved
REPLACE NAVIGATION LIGHTS WITH TYPE REQUIRED BY 46 CFR 111.75-17(D) PRIOR TO 14FEB91
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Fire Fighting
Issued 16 August 1990 Resolved
REPAIR ELECTRIC STAIR TOWER FIRE DOOR CLOSURE SYSTEM PRIOR TO 22AUG90.
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Fire Fighting
Issued 26 February 1988 Resolved
CONDUCT A FIRE AND BOAT DRILL WHEN VESSEL IS REACTIVATED. THIS REQUIREMENT SHALL BE COMPLETED IN THE PRESENCE OF A U.S. COAST GUARD MARINE INSPECTOR PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Navigation
Issued 20 March 1986 Resolved
PROVIDE RUDDER ANGLE INDICATOR AND MEANS OF COMMUNICATION AT REMOTE EMER- GENCY STEERING FLAT.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Navigation
Issued 20 March 1986 Resolved
OBTAIN PLAN APPROVAL FROM U.S. COAST GUARD MERCHANT MARINE TECHNICAL BRANCH (MMT) FOR NEWLY INSTALLED ELECTRIC PUSHBUTTON ENGINE ORDER TELE- GRAPH SYSTEM.
Condition: Unknown
Due 20 March 1986
Resolved 20 March 1986
Unknown
Issued 28 February 1986 Resolved
THE PORT AND STBD SEACHEST SIX INCH RECIRCULATION VALVES WERE NOT RENEWED DURING DRYDOCK. THESE TWO VALVES WILL BE REQUIRED TO BE RENEWED WITH CG ACCEPTABLE VALVES AT NEXT DRYDOCK, DEC 1987.
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Engineering
Issued 28 February 1986 Resolved
DEMONSTRATE MAIN DIESEL ENGINE OVERSPEED TRIPS.
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Engineering
Issued 28 February 1986 Resolved
EOT AUDIBLE AND WRONG DIRECTION BELLS NOT OPERATING PROPERLY.
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Engineering
Issued 28 February 1986 Resolved
PROVIDE CAM POSITION INDICATOR LIGHTS AT ENGINE ROOM CONSOLE FOR MAIN ENGINES.
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Electrical
Issued 28 February 1986 Resolved
DEMONSTRATE REMOTE STOPS FOR ENGINE FUEL OIL AND LUBE OIL PUMPS.
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Fire Fighting
Issued 28 February 1986 Resolved
THE EMERGENCY FIRE PUMP MUST BE DEMONSTRATED WITH CORRECT PITOT TUBE PRESSURE.
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Navigation
Issued 28 February 1986 Resolved
DEMONSTRATE EMERGENCY STEERING AAT WHEELHOUSE.
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Unknown
Issued 5 December 1985 Resolved
OPEN FOR INSPECTION THE ENGINE ROOM EMERGENCY BILGE SUCTION VALVE.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Construction/Loadline
Issued 5 December 1985 Resolved
INSTALL SOUNDING DEVICES IN ALL DOUBLE BOTTOM BALLAST TANKS IAW 46 CFR 56.50-90.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985

Casualty record · 1

1 March 2003Routine · role: Involved in a Marine Casualty · activity 1751747
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.