MAURY USCG vessel records Sign in
← All vessels

WATER TAXI

WATER TAXI is a 1976 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 1986, most recently in August 1994, along with 6 deficiencies.

Records from 1986 to 1994. Most recent: inspection, 4 August 1994.

Built
1976
Last inspected
4 August 1994
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WSD7991
264284
Flag
UNITED STATES
—
Maury page id
psix-264284

Inspections, by type

Years with a record 9 calendar years (1986–1994)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

4 August 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359896
6 August 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1154375
2 July 1993 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1153766
11 February 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1144242
5 November 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1263407
18 July 1991 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 932265
9 July 1990 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1242296
7 March 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 917329
18 January 1989 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1202223
10 February 1988 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1026708
11 June 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1311207
28 January 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1308577
15 January 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1306028

Deficiency record · 6

Construction/Loadline
Issued 5 November 1992 Resolved
MAKE PERMANENT REPAIRS TO ALL CRACKED WELDS IN THE GUNNEL CORNERS.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Accommodation/Occupational Safety
Issued 5 November 1992 Resolved
REPAIR ALL ROTTEN SEAT TOPS.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Electrical
Issued 18 July 1991 Resolved
PRIOR TO CARRYING PASSENGERS MAKE REPAIRS TO VESSEL'S ALTERNATOR.
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Engineering
Issued 9 July 1990 Resolved
REPLACE CRACKED FUEL BOWL ON RACOR FUEL FILTER AND PROVIDE METAL BOWL FLAMESHIELD OR INSTALL CG APPROVED FILTER GAS SEPERATOR. THIS ITEM IS TO BE COMPLETED PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Fire Fighting
Issued 9 July 1990 Resolved
PROVIDE ONBOARD ADDITIONAL B1 FIRE EXTINGUISHER.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Engineering
Issued 10 February 1988 Resolved
MAKE ENGINE COMPARTMENT BLOWER OPERABLE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 February 1988
Resolved 10 February 1988

Ownership record