MAURY USCG vessel records Sign in
← All vessels

GELBERMAN

GELBERMAN is a 1980 public vessel, unclassified. The Coast Guard has recorded 91 inspections since 1986, most recently in August 2025, along with 112 deficiencies.

Records from 1986 to 2025. Most recent: inspection, 27 August 2025.

Built
1980
Last inspected
27 August 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

264384
Flag
UNITED STATES
—
Maury page id
psix-264384

Inspections, by type

…with no type recorded6
Years with a record 37 calendar years (1986–2025)
The 91 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it110 - Regulatory (Subpart C or D), Gross Ton
74 - Regulatory (Subpart C or D), Net Ton
190 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 91

27 August 2025 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8219199
12 November 2024 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8033351
4 September 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7995146
28 May 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7921252
6 September 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7786024
13 September 2022 Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7557897
25 October 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7339306
11 June 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7339376
9 September 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7054126
10 September 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6808069
15 August 2018 Annual Inspection · MTSA Verification · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6513074
11 April 2018 Internal Structural Exam · Drydock Extension · Administrative Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6389520
20 September 2017 Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6274254
27 September 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6009865
23 March 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5838870
15 September 2015 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5719100
29 October 2014 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5014156
11 February 2011 Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3943373
27 September 2010 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3857853
3 November 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3356354
30 September 2008 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3335766
15 August 2008 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3299072
12 February 2008 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3146069
19 October 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3083006
21 September 2007 Periodic Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3062651
9 February 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2870316
10 October 2006 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2806030
25 January 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2572901
27 September 2005 MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2502429
6 October 2004 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2231298
5 January 2004 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1974671
16 October 2003 Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1934362
8 January 2003 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1727667
16 December 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1719754
27 November 2001 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1410703
9 January 2001 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 825384
9 January 2001 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1397518
6 October 2000 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1405065
10 August 2000 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1412157
3 November 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 799771
28 October 1999 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 796505
8 October 1998 COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1469209
23 June 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 792188
20 October 1997 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1453416
12 August 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1089093
17 July 1996 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1421170
16 October 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1190986
15 August 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 872267
17 July 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878197
21 February 1995 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1161286
8 September 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 861330
10 August 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868394
22 July 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 868689
13 May 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1180722
17 September 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 841844
7 September 1993 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 841843
18 June 1993 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845000
14 October 1992 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945321
31 August 1992 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944260
26 June 1992 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 950630
4 May 1992 Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937831
14 June 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934483
5 June 1991 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246533
4 June 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 939380
25 March 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246037
19 February 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 922258
24 January 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 901137
14 August 1990 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907141
24 July 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1228934
14 June 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1218504
14 June 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1221938
22 May 1990 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 906659
16 February 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1217019
2 February 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905193
11 August 1989 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1352917
20 July 1989 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349105
9 June 1989 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341990
28 April 1989 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 896227
13 April 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036784
2 February 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1352036
18 April 1988 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341698
16 February 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021763
2 February 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018671
7 October 1987 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1320650
18 September 1987 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313853
21 August 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337951
20 May 1987 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1333339
3 February 1987 Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013242
4 September 1986 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1023342
16 May 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 992440
3 February 1986 Credit Drydock · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1305536

Deficiency record · 112

04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 September 2025 Resolved
Drills must, as far as practicable, be conducted as if there were an actual emergency. Vessel was unable to conduct underway drills while steering repairs were in progress. Demonstrate underway drills to the satisfaction of an attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2025
Resolution: Conducted satisfactory man overboard drill. Verified satisfactory operation of newly installed steering pump. Also, Sea Safetey was onboard. Witnessed satisfactory test & operation of CO2 system, time delay (31 seconds), siren & engineroom discharge.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 September 2025 Resolved
The inspection for certification shall include an inspection of equipment to insure that the vessel is in satisfactory condition. CO2 system alarms and shutdowns did not function (faulty distribution valve) Repair and demonstrate to the satisfaction of an attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2025
Resolution: Conducted satisfactory man overboard drill. Verified satisfactory operation of newly installed steering pump. Also, Sea Safetey was onboard. Witnessed satisfactory test & operation of CO2 system, time delay (31 seconds), siren & engineroom discharge.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 November 2024 Resolved
The o/o must provide satisfactory evidence of the required servicing to the marine inspector. The remote activation for the fixed CO2 system from the bridge was tagged 2023 and the servicing report did not note it was subject to testing during it's 2024 annual testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 November 2024
Resolution: Recieved documentation attesting to the servicing of the pilot house remote activation pulls from the servicing company.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 12 November 2024 Resolved
The main steering gear must be capable of moving the rudder from 35 degrees on either side to 35 degrees on the other. During the dockside steering test using steering pump #2, rudder angle indicator was displaying 32-34 degrees both port and starboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 November 2024
Resolution: Engineers statement provided attesting to the proper operation of the vessel's rudder angle indicator via calibration.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 12 November 2024 Resolved
Beacon registration is required for the EPIRB. Provided sufficient documentation attesting to the proper registration of the vessel's beacon.
Action required: 10 - Deficiency Rectified
Resolved 12 November 2024
Resolution: Provided documentation duirng the inspection
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 September 2024 Resolved
The inspection shall be such as to ensure that the workmanship of all parts of the vessel and it's equipment is in all respects satisfactory for it's intended service. During the internal structural exam, MI discovered an area in way of the shaft assembly requiring further evaluation. Vessel to clean and prep the area for further evaluation and provide sufficient evidence to determine the thickness of the material in the area in question. Area appeared to be filled with an epoxy or caulk material and was then painted over. Gauging should be conducted to determine the extent of wastage prior to determining the extent of repairs necessary.
Action required: 705 - Other - as specified
Resolved 6 September 2024
Resolution: Attended and accepted the area in question after it was cleaned and presented in a way to allow for closer inspection. Area was accepted satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 September 2020 Resolved
46CFR199.262 46CFR199.640(g) Each cargo vessel must carry at least one rescue boat, the Gelberman may carry a workboat IAW 46CFR199.640(g). Rescue boat was not inflated satisfactory. Provide manufacturer guidance for leak testing rescue boat and leak test rescue boat with CG MI in attendance.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 October 2020
Resolution: Test sat
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 9 September 2020 Resolved
46CFR199.190(e) Provide immersion suit invoices in order to determine age of suits and testing intervals IAW NVIC 01-08.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2018 Resolved
Vessel was unable to demonstrate proper operation of fixed Bilge pump
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2019
Resolved 2 May 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2018 Resolved
30 second time delay bottle went off at 18 seconds. Required sea safety to replace and retest. all sat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 May 2019
Resolved 2 May 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2018 Resolved
identified badly worn hose for main cylinder valve on CO2 bottle. Sea safety replaced and tested. all sat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 May 2019
Resolved 2 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2018 Resolved
Each self-propelled vessel must be provided with a power-driven pump. Vessel's power-driven bilge pump is not operational. Prove proper operation to attending USCG MI.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 May 2019
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 15 August 2018 Resolved
Every vessel of this section must have a radiotelephone on board capable of operation from its navigational bridge. Vessel's radios on the navigational bridge were not operational. Prove proper operation to attending USCG MI.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 August 2018 Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern of the vessel. Vessel's lifebuoy markings were either faded or left blank. Prove proper markings on all lifebuoys.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2019
Communications › Alarms/Indicators › General Alarm
Issued 20 September 2017 Resolved
Vessel must remove/replace general alarm button on aft port side deck. It is not needed and can't be tied into the general arlarm pannel.
Due 5 October 2017
Resolved 26 October 2017
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 20 September 2017 Resolved
vessel was unable to demonstrate loss of lube oil shut down for the MDE's
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 October 2017
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 20 September 2017 Resolved
Vessel was unable to demonstrate loss of lube oil shutdown to the generators.
Action required: 705 - Other - as specified
Resolved 26 October 2017
Fire Fighting › Fire Main › Condition
Issued 27 September 2016 Resolved
Fire main piping ruptured during testing. Make permanent repairs to the affected section of fire main piping. 46 CFR 95.10-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2016
Resolution: Permanent Repairs were made to the fire main and the system was satisfactorily pressurized.
Fire Fighting › Nozzles › Condition
Issued 27 September 2016 Resolved
Fire nozzles must have threads to accommodate hose connections. Starboard fire hose nozzle threads were bent and could not seal. 46 CFR 95.10-10(m)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2016
Resolution: New nozzle was installed with a good seal and operated as designed.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 15 September 2015 Resolved
Nonmetallic flexible hose in fuel oil and lube oil systems shall not exceed 30 inches. Identified vessel having many non metallic hoses for fuel and lube oil systems for their main engine and appurtenance that exceeds over 30 inches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 18 November 2015
Resolution: Add a special note into MISLE for future reference regarding the nonmetallic hoses.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 September 2015 Resolved
Identified battery cable has lost its mechanical stregth and insulation integrity as designed. Vessel shall replace all battery cable that has lost its mechanical strength and insulation integrity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2015
Resolved 30 March 2016
Resolution: All Battery Cables have been replaced
Documentation › Logs/Records › Dry Cargo Log Book
Issued 29 September 2010 Resolved
No proof of testing of cargo gear (crane), CG835 issued to provide proof of testing.
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 30 September 2010
Resolution: Received Cargo Gear Certificate Inspection Report form ABS.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 30 September 2008 Resolved
Install lagging on all exposed surfaces exceeding 150 degrees F and replace wasted/worn lagging on starboard MDE outboard side and on both MDEs inboard side. 46 CFR 56.50-1(k).
Action required: 705 - Other - as specified
Due 17 November 2008
Resolved 12 December 2008
Resolution: Lagging has been properlly installed on all exhaust surfaces exceeding 150 degrees F and or replaced IAW 46 CFR 56.50-1(k).
Engineering › Bilge Water Management System › Pump
Issued 30 September 2008 Resolved
Installed/approved auxiliary bilge pump on port side MDE is not working properly. Repair and test to the satisfaction of attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 17 November 2008
Resolved 12 December 2008
Resolution: Witnessed satisfactory testing of the installed auxiliary bilge pump on port side MDE.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 21 September 2007 Resolved
Replace CO2 empty cylinders with new filled bottles’/replace flex loop connectors and have all items certified by Sea Safety International. Unknown leak occurred, hydrostatic test all loop and cylinders and replace bottles as needed prior to going back in service.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2007
Resolution: Sea Safety International replaced all four (4) CO2 cylinders and flex loop connectors, CG verified the replacements. Received certificates for all fire fighting equipment. Inspection complete.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 21 September 2007 Resolved
Both MDE's have overspeed protection, demonstrate proper shutdowns.
Condition: Improper/Lack of Maintenance
Due 21 September 2007
Resolved 21 September 2007
Resolution: Chief engineer corrected problem by the end of this inspection, test sat.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 21 September 2007 Resolved
Port MDE loss of L/O alarm failed to actuate, identify and repair and test to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 2 October 2007
Resolved 24 September 2007
Resolution: Replace transducer for the L/O system, test sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 September 2007 Resolved
Bilge alarm panel located on the bridge indicates flooding for both the sewage space and FWD peak when testing the sewage space level indicator. Identify and repair the alarm indication on the panel.
Condition: Improper Installation
Due 2 October 2007
Resolved 24 September 2007
Resolution: Properly labeled alarm panel located on the bridge and wired the indicators to report independently.
Electrical › Electric Generation Source (service) › Panelboard
Issued 21 September 2007 Resolved
Tach meter on the port ship service generator is not indicating properly, repair or replace tachomater.
Condition: Improper/Lack of Maintenance
Due 2 October 2007
Resolved 24 September 2007
Resolution: Replaced tachometer, ran the generator and verified the tachometer, sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 21 September 2007 Resolved
Repair or replace air supply motor on the STBD side of the engine room.
Condition: Improper/Lack of Maintenance
Due 12 October 2007
Resolved 19 October 2007
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 21 September 2007 Resolved
Boiler alarms did not function IAW 46 CFR 63.15-7(a). Test boiler in accordance with instructions for testing boiler controls & safeties (46 CFR 63.10(a)) and certification required under 46 CFR 63.10 (b).
Due 12 October 2007
Resolved 19 October 2007
Resolution: New panel installed in the athwartship passageway.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 October 2006 Resolved
Navigation light panel missing audible alarm.
Due 15 December 2006
Resolved 9 February 2007
Resolution: Witnessed satisfactory operation of audible and visual alarm in way of navigation light panel.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 October 2006 Resolved
Bilge high level alarm in lazarette inoperable.
Due 24 November 2006
Resolved 24 November 2006
Resolution: Corrected.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 10 October 2006 Resolved
Stbd generator F/O pump leaking fuel. Repair 46 CFR 91.25-45
Due 24 November 2006
Resolved 24 November 2006
Resolution: Corrected.
Engineering › Fuel Oil Service System › Hose
Issued 10 October 2006 Resolved
STBD Generator F/O hose on secondary filter is cut through to the inner reinforcement. Replace hose 46 CFR 61.20-3
Due 24 November 2006
Resolved 24 November 2006
Resolution: Corrected.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 10 October 2006 Resolved
STBD Generator overspeed trip is set too high (trips @ 2268). Set trip to 110 - 115% of rated speed (Old J - 46 CFR 110.10-5)
Due 24 November 2006
Resolved 24 November 2006
Resolution: Corrected.
Engineering › Fuel Oil Service System › Hose
Issued 10 October 2006 Resolved
Port Generator F/O hose to pump is cut. Replace - 46 CFR 61.20-3
Due 24 November 2006
Resolved 24 November 2006
Resolution: Corrected.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 10 October 2006 Resolved
Port MDE E-stop does not stop engine completely. Correct 46 CFR 61.20-3
Due 24 November 2006
Resolved 24 November 2006
Resolution: Corrected.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 10 October 2006 Resolved
Boiler flame out alarm did not function IAW 46 CFR 63.15-7(a). Boiler pre-purge period less than 20 seconds (46 CFR 63.25-1). Provide instructions for testing boiler controls & safeties (46 CFR 63.10(a)) and certification required under 46 CFR 63.10 (b).
Due 24 November 2006
Resolved 24 November 2006
Resolution: Corrected.
Communications › Radio Communications › VHF Radiotelephone
Issued 27 September 2005 Resolved
Missing FCC Marine Radio Operator permit.
Condition: Unknown
Due 30 September 2005
Resolved 28 September 2005
Resolution: Viewed valid FCC Marine Operator Permit.
Engineering › Bilge Water Management System › Not Operational
Issued 27 September 2005 Resolved
Missing couplings in the Bilge system therefore not operational until installed.
Condition: Unknown
Due 28 September 2005
Resolved 28 September 2005
Resolution: Witnessed sat test of fixed bilge system by dewatering void space.
Engineering
Issued 5 January 2004 Resolved
Prover propper operation of automation system prior to use.
Due 5 January 2004
Resolved 7 January 2004
Resolution: Witnessed proper operation of automation system.
Engineering
Issued 5 January 2004 Resolved
Clean out bilges.
Due 16 January 2004
Resolved 7 January 2004
Resolution: Bilges cleaned.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 January 2004 Resolved
Prove propper operation of fixed CO2 system in the presence of a CG MI, prior to sailing.
Due 5 January 2004
Resolved 7 January 2004
Resolution: Witnessed proper operation of fixed CO2 system.
Engineering
Issued 5 January 2004 Resolved
Conduct underway steering and main propulsion tests.
Due 5 January 2004
Resolved 7 January 2004
Resolution: Conducted u/w steering and main prop tests.
Fire Fighting › Remote Fuel Shutoff
Issued 16 December 2002 Resolved
Emergency remote fuel shutoff cables are too short and worn. Renew cables as needed. LEGACY COMPONENT DESC: Cables
Condition: Unknown
Due 16 January 2003
Resolved 8 January 2003
Resolution: All cables replace in new, tested satisfactorily.
Fire Fighting › Fire Hoses
Issued 16 December 2002 Resolved
Found starboard fire hose weeping when charged. Fire hose replaced with new hose. Note: 2 hoses were attempted to be put into service but had non-standard coupling threads. Non-standard threads were on couplings marked "FDNY". LEGACY COMPONENT DESC: Condition
Due 16 December 2002
Resolved 16 December 2002
Resolution: Corrected
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 16 December 2002 Resolved
During test of fixed CO2 system, found one discharge nozzle blocked. Servicing company, Sea Safety International, corrected on the spot. LEGACY COMPONENT DESC: Nozzle
Condition: Improper/Lack of Maintenance
Due 16 December 2002
Resolved 16 December 2002
Resolution: Corrected.
Lifesaving
Issued 28 October 1999 Resolved
Liferaft servicing due date expired SEP99. Provide properly serviced liferaft aboard vessel IAW 46 CFR 199.190.
Condition: Unknown
Due 11 November 1999
Resolved 3 November 1999
Electrical
Issued 20 October 1997 Resolved
REPAIR LIGHTING IN MID-BODY BOTTOM COMPARTMENT.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 20 October 1997 Resolved
LINES FOR RING BOUYS AND LANYARD FOR WATERLIGHT FOUND TO BE DETERIORATED FROM UV. ISSUED REQUIRMENT TO REPLACE WITH UV RESISTANT TYPE LINE.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Electrical
Issued 20 October 1997 Resolved
IN ELECTRICAL COMPARTMENT UNDER BRIDGE CONSOLE: REPLACE WIRE NUTS WITH_x001C_ PROPER CONNECTIONS, INSTALL COVER FOR WIRE RECEPTACLE, CLEAN TERMINALS ON POWER SUPPLY, AND REMOVE VARIOUS DEAD ENDED WIRES.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Construction/Loadline
Issued 20 October 1997 Resolved
BILGE HIGH LEVEL ALARMS IN FWD AND MID-BODY COMPARTMENTS INSTALLED TOO HIGH. FOUND APPROXIMATELY 12 INCHES OF STANDING WATER IN THESES BILGES. ISSUED REQUIREMENT TO LOWER BILGE ALARMS TO WITHIN 6 INCHES OF BOTTOM.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 20 October 1997 Resolved
REMOVE OIL FROM BILGES IN ENGINE ROOM.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Electrical
Issued 20 October 1997 Resolved
FOUND WIRE CONNECTIONS WITH WIRE NUTS AND DEAD ENDED WIRES NEXT TO ALARMS IN BILGES OF COMPARTMENTS 2,6, AND 8. ISSUED REQUIREMENT TO REMOVE WIRES AND REPLACE WIRE NUTS WITH PROPER CONNECTIONS.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Electrical
Issued 20 October 1997 Resolved
CLEAN TERMINALS ON EMERGENCY LIGHTING BATTERIES AND REPLACE INSULATION ON WIRES.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Electrical
Issued 20 October 1997 Resolved
WIRES IN CO2 ROOM FOUND LAYING ON AND SUPPORTED BY SHEET METAL COVERS IN OVERHEAD; ISSUED REQUIREMENT TO PROPERLY MOUNT WIRES.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Engineering
Issued 17 July 1996 Resolved
PROVE PROPER OPERATION AND ALARM SYSTEM ON BOILER.
Condition: Unknown
Due 16 August 1996
Resolved 15 August 1996
Electrical
Issued 17 July 1996 Resolved
REPLACE STUFFING TUBE SHIP SERVICE AIR PRESSURE SENSING UNIT.
Condition: Unknown
Due 16 August 1996
Resolved 15 August 1996
Electrical
Issued 17 July 1996 Resolved
REWIRE OR REMOVE DEADEND WIRE IWO STBD SSDG.
Condition: Unknown
Due 16 August 1996
Resolved 15 August 1996
Unknown
Issued 17 July 1996 Resolved
PROVE PROPER OPERATION OF AFTER STEERING SOUND-POWERED PHONE.
Condition: Unknown
Due 16 August 1996
Resolved 15 August 1996
Unknown
Issued 17 July 1996 Resolved
REPLACE FITTINGS AND HOSES ON TARCOR MARCON ALARM SYSTEM FOR SSDG AND MDG IAW 46CFR56.60-25(C) USCG APPROVED SAE J-1475, J-1942.
Condition: Unknown
Due 16 August 1996
Resolved 15 August 1996
Electrical
Issued 17 July 1996 Resolved
INSTALL EMERGENCY LIGHTING IWOENGINE ROOM ESCAPE LADDER AND SSDGS. (3) REQUIRED.
Condition: Unknown
Due 16 August 1996
Resolved 15 August 1996
Electrical
Issued 17 July 1996 Resolved
VESSEL HAS INTERMITTENT GROUNDS. ELIMINATE GROUNDS TO SATISFACTION OF MARINE INSPECTOR.
Condition: Unknown
Due 16 August 1996
Resolved 15 August 1996
Electrical
Issued 17 July 1996 Resolved
MOUNT LIGHT SWITCH IN SEWAGE COMPARTMENT.
Condition: Unknown
Due 16 August 1996
Resolved 15 August 1996
Construction/Loadline
Issued 17 July 1996 Resolved
REPAIR DECKPLATE FRAME IN SEWAGE COMPARTMENT.
Condition: Unknown
Due 16 August 1996
Resolved 15 August 1996
Construction/Loadline
Issued 17 July 1996 Resolved
PROVE PROPER OPERATION OF ALL BILGE ALARMS.
Condition: Unknown
Due 16 August 1996
Resolved 15 August 1996
Navigation
Issued 17 July 1995 Resolved
PROVE PROPER OPERATION OF RUDDER ANGLE INDICATOR FOR EMERGENCY STEERING STATION.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Electrical
Issued 17 July 1995 Resolved
PROVE PROPER OPERATION OF STBD GENERATION.
Condition: Unknown
Due 8 August 1995
Resolved 10 August 1995
Electrical
Issued 17 July 1995 Resolved
HARD WIRE ALL EMERGENCY LIGHTING UNITS.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Fire Fighting
Issued 17 July 1995 Resolved
PROVE PROPER OPERATION OF FIRE PUMP PRIOR TO SAILING.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Engineering
Issued 17 July 1995 Resolved
REPAIR OVERSPEED TRIP ON STBD MDE.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Navigation
Issued 17 July 1995 Resolved
SECURE WIRING TO # 2 STEERING MOTOR CONTROLLER.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Electrical
Issued 17 July 1995 Resolved
REPLACE ALL PLASTIC WIRE-TIES IN E/R WITH METAL WIRE-TIES.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Construction/Loadline
Issued 17 July 1995 Resolved
REPLACE RUBBER GASGET ON EMERGENCY E/R ESCAPE.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Lifesaving
Issued 17 July 1995 Resolved
PROVE GENERAL ALARM IN ENGINE ROOM CAN BE HEARD AT REAR OF E/R WITH HEARINGPROTECTION ON.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Construction/Loadline
Issued 22 July 1994 Resolved
REPAIR & PROVE PROPER OPERATION OF ENGINE ROOM HIGH LEVEL BILGE ALARM.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Engineering
Issued 22 July 1994 Resolved
PROVE PROPER OPERATION OF THE MAIN E/R PACT SUPPLY VENT BLOWER EMERGENCY STOPS.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Engineering
Issued 22 July 1994 Resolved
REPAIR & PROVE PROPER OPERATION OF THE STBB M/E LOW LUBE OIL ALARM.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Engineering
Issued 22 July 1994 Resolved
CONDUCTED A HYDROSTATIC TEST OF THE ENGINE ROOM AIR RECEIVER TO 1.25 X MAWP& TEST THE SAFETY RELIEF VALVE.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Navigation
Issued 22 July 1994 Resolved
CALIBRATE ALL RUDDER ANGLE INDICATORS.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Electrical
Issued 22 July 1994 Resolved
RE-WIRE LOUDSPEAKER ON AFTER DECK.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Engineering
Issued 22 July 1994 Resolved
MAKE PERMANENT REPAIRS TO ON-DECK ELECTRICAL STUFFING BOXES.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Fire Fighting
Issued 18 June 1993 Resolved
PROVE PROPER OPERATION OF ENGINEROOM FIXED CO2 TIME DELAY RELEASE TO SATISFACTION OF ATTENDING MARINE INSPECTOR NO LATER THAN 28JUN93.
Condition: Unknown
Due 13 July 1993
Resolved 13 July 1993
Accommodation/Occupational Safety
Issued 18 June 1993 Resolved
PROVE PROPER OPERATION OF ENGINEROOM SUPPLY FAN, STARBOARD SIDE.
Condition: Unknown
Due 13 July 1993
Resolved 13 July 1993
Electrical
Issued 18 June 1993 Resolved
INSTALL MECHANICAL INTERLOCK ON MAIN SWITCHBOARD TO PREVENT PARALLEL OPERATION OF SHIPS SERVICE GENERATORS.
Condition: Unknown
Due 13 July 1993
Resolved 13 July 1993
Unknown
Issued 18 June 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 July 1993
Resolved 13 July 1993
Navigation
Issued 26 June 1992 Resolved
PROVE PROPER OPERATION OF NAV LIGHT PANEL, ALARMS & LIGHTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 July 1992
Resolved 23 July 1992
Construction/Loadline
Issued 4 May 1992 Resolved
RENEW STERN TUBE SEACOCK SEA VALVE AND PROOF PROPER OPERATION 3 DRAIN VALVES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Construction/Loadline
Issued 4 May 1992 Resolved
PROPERLY REPAIR CRACKED WELD IN RUB RAIL ON STBD SIDE 4FT AFT OF FORWARD BIT._x001C_
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Construction/Loadline
Issued 4 May 1992 Resolved
PROPERLY REPAIR TWO CRACKED WELDS IN SPACE NUMBER 7 IN WAY OF AFT BULKHEAD AND FRAME #4 FROM FORWARD BULKHEAD AND OVERHEARD.
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Engineering
Issued 24 January 1991 Resolved
PROVE PROPER OPERATION OF AUDIBLE BILGE ALARM ON BRIDGE.
Condition: Unknown
Due 24 January 1991
Resolved 24 January 1991
Electrical
Issued 24 January 1991 Resolved
PROVE ELIMINATION OF ELECTRICAL GROUND ON ELECTRICAL SWITCHBOARD IN ENGINE_x001C_ROOM.
Condition: Unknown
Due 24 January 1991
Resolved 24 January 1991
Electrical
Issued 2 February 1990 Resolved
PROPERLY SEAT ALL SEVEN (7) ELEC CABLES IN GLANDS AT BASE OF MAST TOP OF WHEELHOUSE.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Lifesaving
Issued 2 February 1990 Resolved
RENEW LINES ON ALL RING LIFE BUOYS.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Construction/Loadline
Issued 2 February 1990 Resolved
FREE-UP VENT COVERS PORT FWD AND ALL FOREDECK VENTS.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Engineering
Issued 2 February 1990 Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL ALARMS ON BOTH MAIN DIESEL ENGINES.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Fire Fighting
Issued 2 February 1990 Resolved
PROVE PROPER OPERATION OF FIRE ALARM SENSORS IN ENGINE ROOM.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Engineering
Issued 2 February 1990 Resolved
PROVE PROPER OPERATION OF AUXILIARY HEATING BOILER IAW 46 CFR 63.10.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Engineering
Issued 2 February 1990 Resolved
HYDROSTATICALLY TEST AUX HEATING BOILER AND DEMONSTRATE OPERATION OF SAFETYVALVE.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Engineering
Issued 2 February 1990 Resolved
PROVIDE EXHAUST LAGGING OR SHIELDING FOR GENERATOR #2 AND CRANE HYDRAULIC PUMP ENGINE.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Electrical
Issued 2 February 1990 Resolved
REMOVE UNUSED ELECTRICAL CABLE CONNECTED TO STEERING CONTROLLER.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Fire Fighting
Issued 2 February 1989 Resolved
PROVIDE RETAINING CHAINS FOR SPANNER WRENCHES ON PORT AND STARBOARD FIRE STATIONS.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Lifesaving
Issued 2 February 1989 Resolved
PROVIDE REPLACEMENT RETROREFLECTIVE TAPE FOR LIFEJACKETS AND LIFE RING BUOYS.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Engineering
Issued 2 February 1988 Resolved
PROVE PROPER OPERATION OF THE PORT ENGINE OVERSPEED TRIP.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Electrical
Issued 2 February 1988 Resolved
REPAIR AND PROVE PROPER OPERATION OF THE GENERAL ALARM CONTACT MAKERS.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Electrical
Issued 2 February 1988 Resolved
REPLACE THE BROKEN LIGHT GLOBE IN THE PORT VOID AFT OF THE MACHINERY SPACE.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Electrical
Issued 2 February 1988 Resolved
REPLACE CRACKED BATTERY BOX AND PROVIDE MEANS TO SECURE IT FROM SHIFTING IN THE RESCUE BOAT.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Navigation
Issued 2 February 1988 Resolved
PROPERLY MARK CALL STATIONS ON THE SOUND POWERED PHONE LOCATED AT THE ALTERNATE STEERING/CONTROL STATION.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Construction/Loadline
Issued 2 February 1988 Resolved
FREE-UP ALL WEATHER DECK HATCH CLOSING DOGS.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Engineering
Issued 2 February 1988 Resolved
CLEAN BILGES IN THE PORT VOID (AFT OF MACHINERY SPACE) OF DEBRIS.
Condition: Unknown
Due 2 February 1988
Resolved 2 February 1988
Fire Fighting
Issued 3 February 1987 Resolved
REPLACE ALL FOUR CO2 BOTTLES FOR THE FIXED CO2 SYSTEM IN KIND. BOTTLES WERE PITTED AND HEAVILY CORRODED.
Condition: Unknown
Due 3 February 1987
Resolved 3 February 1987

Ownership record