GELBERMAN is a 1980 public vessel, unclassified. The Coast Guard has recorded 15 inspections since 2016, most recently in August 2025, along with 19 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 27 August 2025.

Built
1980
Last inspected
27 August 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 August 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

264384
Flag
UNITED STATES
Maury page id
psix-264384

Documentation record

Tonnage as PSIX records it110 - Regulatory (Subpart C or D), Gross Ton
74 - Regulatory (Subpart C or D), Net Ton
190 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

27 August 2025 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8219199
12 November 2024 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8033351
4 September 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7995146
28 May 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7921252
6 September 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7786024
13 September 2022 Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7557897
25 October 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7339306
11 June 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7339376
9 September 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7054126
10 September 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6808069
15 August 2018 Annual Inspection · MTSA Verification · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6513074
11 April 2018 Internal Structural Exam · Drydock Extension · Administrative Inspection · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6389520
20 September 2017 Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6274254
27 September 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6009865
23 March 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5838870

Deficiency record · 19

04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 September 2025 Resolved
Drills must, as far as practicable, be conducted as if there were an actual emergency. Vessel was unable to conduct underway drills while steering repairs were in progress. Demonstrate underway drills to the satisfaction of an attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2025
Resolution: Conducted satisfactory man overboard drill. Verified satisfactory operation of newly installed steering pump. Also, Sea Safetey was onboard. Witnessed satisfactory test & operation of CO2 system, time delay (31 seconds), siren & engineroom discharge.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 September 2025 Resolved
The inspection for certification shall include an inspection of equipment to insure that the vessel is in satisfactory condition. CO2 system alarms and shutdowns did not function (faulty distribution valve) Repair and demonstrate to the satisfaction of an attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 September 2025
Resolution: Conducted satisfactory man overboard drill. Verified satisfactory operation of newly installed steering pump. Also, Sea Safetey was onboard. Witnessed satisfactory test & operation of CO2 system, time delay (31 seconds), siren & engineroom discharge.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 November 2024 Resolved
The o/o must provide satisfactory evidence of the required servicing to the marine inspector. The remote activation for the fixed CO2 system from the bridge was tagged 2023 and the servicing report did not note it was subject to testing during it's 2024 annual testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 November 2024
Resolution: Recieved documentation attesting to the servicing of the pilot house remote activation pulls from the servicing company.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 12 November 2024 Resolved
The main steering gear must be capable of moving the rudder from 35 degrees on either side to 35 degrees on the other. During the dockside steering test using steering pump #2, rudder angle indicator was displaying 32-34 degrees both port and starboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 November 2024
Resolution: Engineers statement provided attesting to the proper operation of the vessel's rudder angle indicator via calibration.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 12 November 2024 Resolved
Beacon registration is required for the EPIRB. Provided sufficient documentation attesting to the proper registration of the vessel's beacon.
Action required: 10 - Deficiency Rectified
Resolved 12 November 2024
Resolution: Provided documentation duirng the inspection
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 September 2024 Resolved
The inspection shall be such as to ensure that the workmanship of all parts of the vessel and it's equipment is in all respects satisfactory for it's intended service. During the internal structural exam, MI discovered an area in way of the shaft assembly requiring further evaluation. Vessel to clean and prep the area for further evaluation and provide sufficient evidence to determine the thickness of the material in the area in question. Area appeared to be filled with an epoxy or caulk material and was then painted over. Gauging should be conducted to determine the extent of wastage prior to determining the extent of repairs necessary.
Action required: 705 - Other - as specified
Resolved 6 September 2024
Resolution: Attended and accepted the area in question after it was cleaned and presented in a way to allow for closer inspection. Area was accepted satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 September 2020 Resolved
46CFR199.262 46CFR199.640(g) Each cargo vessel must carry at least one rescue boat, the Gelberman may carry a workboat IAW 46CFR199.640(g). Rescue boat was not inflated satisfactory. Provide manufacturer guidance for leak testing rescue boat and leak test rescue boat with CG MI in attendance.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 October 2020
Resolution: Test sat
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 9 September 2020 Resolved
46CFR199.190(e) Provide immersion suit invoices in order to determine age of suits and testing intervals IAW NVIC 01-08.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2018 Resolved
Vessel was unable to demonstrate proper operation of fixed Bilge pump
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2019
Resolved 2 May 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2018 Resolved
30 second time delay bottle went off at 18 seconds. Required sea safety to replace and retest. all sat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 May 2019
Resolved 2 May 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2018 Resolved
identified badly worn hose for main cylinder valve on CO2 bottle. Sea safety replaced and tested. all sat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 May 2019
Resolved 2 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2018 Resolved
Each self-propelled vessel must be provided with a power-driven pump. Vessel's power-driven bilge pump is not operational. Prove proper operation to attending USCG MI.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 May 2019
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 15 August 2018 Resolved
Every vessel of this section must have a radiotelephone on board capable of operation from its navigational bridge. Vessel's radios on the navigational bridge were not operational. Prove proper operation to attending USCG MI.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 August 2018 Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern of the vessel. Vessel's lifebuoy markings were either faded or left blank. Prove proper markings on all lifebuoys.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2019
Communications › Alarms/Indicators › General Alarm
Issued 20 September 2017 Resolved
Vessel must remove/replace general alarm button on aft port side deck. It is not needed and can't be tied into the general arlarm pannel.
Due 5 October 2017
Resolved 26 October 2017
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 20 September 2017 Resolved
vessel was unable to demonstrate loss of lube oil shut down for the MDE's
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 October 2017
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 20 September 2017 Resolved
Vessel was unable to demonstrate loss of lube oil shutdown to the generators.
Action required: 705 - Other - as specified
Resolved 26 October 2017
Fire Fighting › Fire Main › Condition
Issued 27 September 2016 Resolved
Fire main piping ruptured during testing. Make permanent repairs to the affected section of fire main piping. 46 CFR 95.10-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2016
Resolution: Permanent Repairs were made to the fire main and the system was satisfactorily pressurized.
Fire Fighting › Nozzles › Condition
Issued 27 September 2016 Resolved
Fire nozzles must have threads to accommodate hose connections. Starboard fire hose nozzle threads were bent and could not seal. 46 CFR 95.10-10(m)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 September 2016
Resolution: New nozzle was installed with a good seal and operated as designed.