MAURY USCG vessel records
← All vessels

THE MARIKA

Built
1986
Last inspected
8 October 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 October 2024
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE9581
264442
Flag
UNITED STATES
Maury page id
psix-264442

Documentation record

Registered dimensions (L × B × D)90.5 ft × 23.1 ft × 11.7 ft
Registered tonnagegross 99 / net 68
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderT D VINETTE COMPANY · ESCANABA, MI, UNITED STATES · built 1986
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHUDSON, NY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 5 August 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
68 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 12 inspections, each with its date, unit and type; 39 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

8 October 2024 Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8015893
24 July 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7966005
10 May 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7685538
18 August 2022 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7538282
19 August 2021 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7283995
4 June 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7215692
29 May 2019 COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6698630
25 April 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6719994
24 April 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6670221
15 June 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6448167
20 June 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6181080
20 June 2016 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5914026

Deficiency record · 39

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 July 2025 No resolution recorded
At each inspection of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure. Significant interior and exterior corrosion was discovered throughout the vessel. Complete the following work list items to make the vessel ready for re-inspection: a) Sandblast entire hull to bare steel. b) Sandblast and clean out each tank and void space, including spaces where entry is blocked by ovens or work counters. c) Remove ballast from engine room and clean the bilge pockets. d) Sandblast and audio gauge galley deck and forward main deck. e) Audio gauge every 18" in the longitudinal and transverse directions. Prepare a full gauging report. Highlight areas that exceed 25% wastage. f) Remove bulkhead facades on the upper deck for inspection.
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 August 2021 Resolved
All vessel shall be provided with a satisfactory arrangement for draining any watertight compartment. Bilge system did not function. 46CFR182.25-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2021
Resolution: Vessel demonstrated satisfactory bilge arrangments.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 August 2021 Resolved
All vessel shall be provided with a satisfactory arrangement for draining any watertight compartment. Vessel is required to have two bilge pumps. The crew did not know if the secondary bilge pump (PTO pump) worked and did not attempt to see if it worked. 46CFR182.25-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2021
Resolution: Vessel demonstrated satisfactory bilge arrangments.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2021 Resolved
All unfired pressure vessels shall be Coast Guard approved. Design, testing, and construction will be in accordance with applicable regulations in subchapter F. Provide data plate for air receiver attesting to its approval. During internal inspection found corrosion,P/V requires hydrostatic test along with test of relief valve. 5 year expired 6/29/2020.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2021
Resolution: Vessel removed air received from vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2021 Resolved
Electrical equipment on board vessel must be installed and maintained. Electrical connections on battery terminals are loose. 46CFR183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2021
Resolution: Witnessed satisfactory attachment of battery terminal hardware
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2021 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and the purpose intended. Valves on sea chest going to port engine/generator did not have handles. 46CFR182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2021
Resolution: Witnessed satisfactory attachment of seachest handle
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2021 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and the purpose intended. Remove temp repair made on stbd generator exhaust piping for inspection. Submission of repair proposal required if piping found defective. Complete NLT next dry dock
Action required: 705 - Other - as specified
Resolved 18 August 2022
Resolution: Cleared during vessel's ddx.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2021 Resolved
Each floating waterlight must be approved in accordance with sub-chapter Q of this chapter. Ring lifebuoy waterlight is inop. 46CFR180.70(d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 September 2021
Resolution: Witnessed satisfactory operation of lifebuoy waterlight
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 August 2021 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Bilge piping going to space under galley disconnected on engine room fwd bulkhead. Allows for water ingress when pump is running. 46CFR182.25-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2021
Resolution: Vessel demonstrated satisfactory bilge arrangments. Pipe re-connected.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 August 2021 Resolved
Vital system piping shall comply with subchapter F. Flexible hose installed on fire line piping going from bilge piping to fire pump and port engine PTO to fire main piping. Both directly in front of port engine. Submit repair proposal, complete NLT next dry dock. 46CFR182.40-5(b)
Action required: 705 - Other - as specified
Resolved 18 August 2022
Resolution: Cleared during vessel's ddx.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 May 2019 Resolved
Prove functionality of bilge pumping arrangement for each space served.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2019
Resolution: video
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 May 2019 Resolved
Secure gray water pump in forward compartment.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: MI verified that the pump was secured in the compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 May 2019 Resolved
Replace retro-reflective tape on 02 main deck life rings with SOLAS tape.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Retro-reflective tape was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
AV compartment above ladderwell to forward galley: place wire twists in an enclosure.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 31 May 2019
Resolution: pics
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
AV compartment above ladderwell to forward galley: repair recessed lighting in overhead.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: MI verified that the recessed lighting had been repaired by way of re-securing the lights into their respective locations.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 May 2019 Resolved
Remove AC drain piping in galley (port and stbd).
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: MI verified that piping not in use for the actively utilized AC had been removed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 May 2019 Resolved
Provide proof of Gaylord Hood servicing in galley by 31MAY2019. Becomes code 701 @ 2359 on 31MAY2019.
Action required: 705 - Other - as specified
Due 31 May 2019
Resolved 31 May 2019
Resolution: pics
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
Remove or place in enclosure, the dead-end wire to right of escape scuttle in galley.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Junction box was added to the area.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
Security light inboard of escape scuttle in galley needs to be properly affixed.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Light was affixed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
Provide proper connection from generator panel to switchboard (left side when facing it). Currently electrical taped.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Connection was made utilizing tubing and flex hose.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
All wire connections inside local generator electrical boxes must have pressure fittings (presently taped.) Boxes must also be capable of being closed. Action taken changed to 701C on 6/5/2019 - MHM
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2019
Resolved 12 June 2019
Resolution: Connections were made with pressure fittings and both boxes were capable of being clossed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 May 2019 Resolved
Port engine belt missing forward guard. Install.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Crew constructed a guard from wood.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
All electrical panels in engine room have multiple openings on sides. Enclose properly.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Panels were closed utilizing plugs for the openings.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 May 2019 Resolved
Engine room emergency fuel shutoff does not secure all the way. Due date updated to 6/12/2019 during 6/5/2019 def check - MHM
Action required: 705 - Other - as specified
Due 12 June 2019
Resolved 12 June 2019
Resolution: Valve was capable of being completely shut.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
Port aft stairwell recess has jimmy rigged electrical installation for the LED strip on the "watch your step" step. Place junction in enclosure with pressure fitting or remove.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Junction box was added to the area w/the connection made inside of it.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
Remove all LED lighting strips external to vessel (see vessel masts).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2019
Resolution: Cleared by LT S.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 May 2019 Resolved
Post corrected PFD donning placard throughout ship. Type posted does not match PFD carried.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Correct donning placard posted.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 May 2019 Resolved
Replace and date battery on float light.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Battery replaced and dated.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 May 2019 Resolved
New first aid kit required.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: New first aid kit acquired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 May 2019 Resolved
Forward port fire station valve unable to be secured. Leaks continuously. (Test with system energized).
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Valve replaced and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
"Power Horn" atop forward bridge window has electrical connection that must be made in an enclosure.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Junction box was added to the area with connection inside.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 May 2019 Resolved
NEW life ring on port bridge wing. Grab lines wasted.
Action required: 705 - Other - as specified
Due 5 June 2019
Resolved 5 June 2019
Resolution: Bridge wing life ring satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 May 2019 Resolved
SEGREGATE CHILD LIFE JACKETS FROM ADULTS - TEMPORARY CARDBOARD INSTALLATION IS COMPLETELY INSUFFICIENT.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2019
Resolution: Cleared by LT S.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 April 2019 Resolved
C/R to good material, stbd side shell IWO A/C drain in Engine Room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2019
Resolution: Repairs have been complete
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 25 April 2019 Resolved
Descale all voids.
Action required: 705 - Other - as specified
Due 30 November 2019
Resolved 18 August 2022
Resolution: Cleared during vessel's ddx.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 15 June 2018 Resolved
Vessel must carry adequate up-to-date publications. Vessel missing coast pilot and light list.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2018
Resolved 15 June 2018
Resolution: Vessel printed off new publications.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 June 2018 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Child and adult life jackets are stowed together on the main deck. Life jackets need to be stowed separated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2018
Resolved 18 August 2022
Resolution: Cleared during vessel's ddx.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 June 2016 Resolved
Properly install DSC on VHF radios.
Condition: Improper/Lack of Maintenance
Due 20 July 2016
Resolved 19 July 2016
Resolution: DSC properly installed.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 20 June 2016 Resolved
Provide proper operation of ground detection system.
Condition: Improper/Lack of Maintenance
Due 20 July 2016
Resolved 6 July 2016
Resolution: Vsl rep attested to proper op.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.