MAURY USCG vessel records
← All vessels

MISS BLUE HERON

MISS BLUE HERON is a 1985 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in May 2026, along with 20 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 5 May 2026.

Built
1985
Last inspected
5 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WSC7597
264521
Flag
UNITED STATES
Maury page id
psix-264521

Inspections, by type

Years with a record 10 calendar years (2016–2026)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)74.9 ft × 23.5 ft × 6.3 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROTHERS ENTERPR. · LOREAUVILLE, LA, UNITED STATES · built 1985
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portRIVIERA BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 17 December 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 17

5 May 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8367286
6 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8129127
23 October 2024 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8023484
13 May 2024 DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7912170
13 February 2024 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7863174
16 January 2024 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7850392
5 May 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7681608
22 September 2022 Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7564039
8 February 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7392475
9 April 2021 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7171707
18 September 2020 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7060663
16 June 2020 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6978018
15 February 2019 Administrative Inspection · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6626327
21 September 2017 Administrative Inspection · Plan Review "T" Boat · In-Service Inspection · Deadweight Survey · Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6271827
15 August 2017 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6241085
20 August 2016 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5982622
24 May 2016 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5885081

Deficiency record · 20

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 May 2026 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents. First-aid kit missing content.
Action required: 10 - Deficiency Rectified
Resolved 5 May 2026
Resolution: Corrected on the spot. New kit purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 May 2025 Resolved
Each life float must be fitted with a light. Life float light is inoperable.
Action required: 10 - Deficiency Rectified
Resolved 6 May 2025
Resolution: Replaced.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 13 May 2024 Resolved
Master with passengers for hire failed to be compelled by marine employer to conduct pre-employment chemical testing as required prior to be conducting safety sensitive duties.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2024
Resolved 13 May 2024
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 13 February 2024 Resolved
A vessel is inspected for compliance with the standards required by this Subchapter. Equipment not covered by standards in this Subchapter may be inspected in accordance with standards acceptable to the OCMI as good marine practice. Potable water tank has pin hole leak in aft bottom section. Temp repairs using J-B Weld are authorized. Permanent repairs are to be completed by vessel's next schedule drydock on 31OCT2024.
Action required: 705 - Other - as specified
Due 31 October 2024
Resolved 23 October 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 February 2024 Resolved
A vessel must carry either a first-aid kit approved under 160.041 or a kit with equivalent content. First-aid kit content expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 22 February 2024
Resolution: Provided.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 February 2024 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability letter, the maximum number of passengers allowed on upper deck must be indicated. Sign missing at the entranceway to upper deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 22 February 2024
Resolution: Installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 February 2024 Resolved
Each life float must be fitted with a light. Light is cracked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2024
Resolved 22 February 2024
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 January 2024 Resolved
At each subsequent inspection, the owner shall be prepared to conduct test and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of piping. Inlet piping IWO sea valve has pitting. Repair or replace to the satisfaction of attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2024
Resolved 1 February 2024
Resolution: All repairs completed and satisfactory.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 May 2023 Resolved
EPIRB's hydrostatic release is expired. Install current hydrostatic release. Operations restricted to no more than 3 miles from shore. 46 CFR 185.740
Action required: 705 - Other - as specified
Resolved 17 May 2023
Resolution: HRU replaced with current release.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2023 Resolved
Portable fire extinguishers not inspected within the last year. Provide current fire service inspection report. 46 CFR 181.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 17 May 2023
Resolution: Service report provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 May 2023 Resolved
1 of the vessel's life floats is weathered. Life float to be re-sealed or replaced. 46 CFR 180.130
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 17 May 2023
Resolution: Life float re-sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 May 2021 Resolved
6 man life float in non-serviceable condition. Replace life float with approved type. Max persons allowed reduced to 132. 46 CFR 180.200
Action required: 705 - Other - as specified
Resolved 8 June 2021
Resolution: Life float replaced SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 May 2021 Resolved
Life float water lights lanyards are in non-serviceable condition. Replace lanyards with at least 18 feet of approved type for each light. 46 CFR 180.175(f)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 19 May 2021
Resolution: Lanyards replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 11 May 2021 Resolved
Life ring float light lanyard in non-serviceable condition. Replace lanyard with 3-6 feet of approve type. 46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 19 May 2021
Resolution: Lanyard replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2017 Resolved
Prove proper operation of fire hose shutoff valves.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2017
Resolved 22 February 2019
Resolution: New valves installed and tested SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 August 2017 Resolved
Provide servicable 6 man lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2017
Resolved 22 February 2019
Resolution: All lifefloats is SAT condition.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 August 2017 Resolved
Provide current FCC SSL.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2017
Resolved 22 February 2019
Resolution: FCC SSL current.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2017 Resolved
Provide cover for deckhouse light on port side pilot house.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2017
Resolved 22 February 2019
Resolution: Cover provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 August 2017 Resolved
Install class B AIS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2017
Resolved 22 February 2019
Resolution: AIS installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 20 August 2016 Resolved
Prove proper operation of STBD inboard main engine due to faulty injector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2016
Resolution: Proved proper operation of main engine.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.