MAURY USCG vessel records Sign in
← All vessels

DEVSI

DEVSI is a 1985 tank ship. The Coast Guard has recorded 66 inspections since 1986, most recently in September 2003, along with 24 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 1986 to 2003. Most recent: inspection, 19 September 2003.

Built
1985
Last inspected
19 September 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8319926 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
264688
Flag
INDIA
—
Maury page id
psix-264688

Inspections, by type

…with no type recorded51
…past their stated due date1
Years with a record 18 calendar years (1986–2003)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it52629 - Regulatory (Subpart C or D), Gross Ton
28898 - Regulatory (Subpart C or D), Net Ton
94706 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 66

19 September 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1910562
19 September 2003 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1944945
7 August 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1869147
5 July 2003 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1835866
3 December 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1726961
20 October 2002 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1693348
13 August 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1660676
1 July 2002 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1638324
12 June 2002 Control Verification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1629804
29 June 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 291478
27 June 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 291435
18 June 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 291150
5 October 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 282849
10 July 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 279621
9 June 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 279468
2 June 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 278537
1 June 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 278478
12 November 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 434510
1 June 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 429267
15 February 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 425580
12 December 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 423590
15 July 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 418070
2 June 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 421265
24 February 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 413130
23 June 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 405060
23 June 1997 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1452304
2 June 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 417894
2 May 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 403283
2 May 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 451236
30 January 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 454969
19 November 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 397648
31 October 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 397190
26 September 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 395857
4 July 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 392814
6 August 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 381113
12 June 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 379411
22 November 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 372531
22 November 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 832645
16 October 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 371421
7 October 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 483384
8 July 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 864941
21 June 1994 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 367786
21 June 1994 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 864174
5 December 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 362839
1 July 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 359135
7 May 1993 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1135978
4 February 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 647532
9 December 1992 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830061
13 October 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 54623
5 October 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 353463
21 September 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 458544
25 August 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 647533
15 July 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 40475
25 March 1992 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1259158
9 October 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 470613
12 April 1991 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1216464
24 March 1990 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983219
11 August 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 498209
23 March 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 523924
23 March 1989 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1338861
12 March 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 489822
2 September 1987 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1002586
28 August 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 318112
1 August 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 525211
6 February 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 306933
5 January 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1298519

Deficiency record · 24

Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 19 September 2003 No resolution recorded
Have class inspect soft patch on entry pipeline into deck seal. Class to attest to condition of piping under suspected soft patch under deck seal water filling line. If class finds wastage or cracks on piping, piping must be permanently repaired prior to arrival at next U.S. port.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 October 2003 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment
Issued 19 September 2003 Resolved
IOPP issuing authority must verify that piping from discharge of OWS to sideshell, including overboard discharge valve has been cleaned, thereby ensuring piping is free of standing oil. Proper operation of OWS 15ppm alarm & automatic stop must be retested in IOPP issuing authority's presence. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2003
Resolved 20 September 2003
Resolution: Received class report from DNV attesting their satisfaction its proper testing.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 20 October 2002 Resolved
#3 CARGO DEEP WELL PUMP INOPERABLE. LEGACY COMPONENT DESC: Cargo Pump
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2002
Resolution: RCVD TECHNICIAN REPORT INDICATING #3 DEEP WELL PUMP WAS REPAIRED.
Navigation › Collision/Grounding Avoidance
Issued 11 August 2002 Resolved
Vsl issued LOD to enter the Port of Corpus Christi with an inoperable primary radar with the understanding that the equipment will be operable prior to departure from port. 33 CFR 164.35(a). LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2002
Resolution: Received tech report stating equipment was operational.
Lifesaving › Lifeboat
Issued 1 July 2002 Resolved
Port life boat failed to start. LEGACY COMPONENT DESC: Propulsion Engine
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2002
Resolution: Battery charger had loose connection allowing the battery to drain. Installed a new spare battery and properly connected the charger.
Accommodation/Occupational Safety
Issued 18 June 2001 Resolved
AFT DECK BY WAY OF DECK MACHINERY STEAM PIPE HOLED AND LEAKING. REPAIR TO THE SATISFACTION OF CLASS NO LATER THAN 18 JULY 2001.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Engineering
Issued 18 June 2001 Resolved
SEA WATER INLET PIPE FOR STEAM TURBINE CONDENSOR HOLED AND LEAKING. REPAIRTO THE SATISFACTION OF CLASS NO LATER THAN 18 JULY 2001.
Condition: Unknown
Due 18 July 2001
Resolved 29 June 2001
Engineering
Issued 18 June 2001 Resolved
TEMPORARY REPAIR ON F/W GENERATOR EJECTOR PIPE. REPAIR TO THE SATISFACTIONOF CLASS NO LATER THAN 18 JULY 2001.
Condition: Unknown
Due 18 July 2001
Resolved 29 June 2001
Accommodation/Occupational Safety
Issued 18 June 2001 Resolved
SEWAGE OVERBOARD DISCHARGE PIPE HOLED AND LEAKING. REPAIR TO THE SATISFACTION OF CLASS NO LATER THAN 18 JULY 2001.
Condition: Unknown
Due 18 July 2001
Resolved 29 June 2001
Deck/Cargo
Issued 18 June 2001 Resolved
VESSEL PROHIBITED FROM CONDUCTING CARGO OPERATIONS IN U.S. WATERS UNTIL CARGO PIPES ARE HYDRO TESTED IN ACCORDANCE WITH 33 CFR 156.170. ALSO NOTEDVESSEL'S VAPOR CONTROL SYSTEM IS NOT APPROVED BY CLASS. *SEE PARTICULAR INTEREST VESSEL NOTE*
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Deck/Cargo
Issued 2 June 2000 Resolved
Repair the pressure side on P/V valves #3C, #1C, #5C, and port slop tank prior to cargo ops in U.S. waters._x001C_ 74 SOLAS Amd II-2/59 46 CFR 32.55-20
Condition: Unknown
Due 30 June 2000
Resolved 30 June 2000
Deck/Cargo
Issued 2 June 2000 Resolved
Provide Class approval for calibration of high level (95%) alarms on #7C, Port Slop Tank, and Starboard Slop Tank prior to 02Jul00. Vessel must maintain manual guaging on said tanks while conducting cargo operations in U.S. waters until corrected. 46 CFR 153.409
Condition: Unknown
Due 27 July 2000
Resolved 27 July 2000
Accommodation/Occupational Safety
Issued 2 June 2000 Resolved
Repair wasted step on ladder near deck seal on port side on main deck._x001C_ _x001C_ _x001C_ ILO 147
Condition: Unknown
Due 30 June 2000
Resolved 30 June 2000
Fire Fighting
Issued 1 June 1999 Resolved
REPLACE MISSING SPRINKLER NOZZLES IN FORWARD PAINT LOCKER.
Condition: Unknown
Due 12 November 1999
Resolved 12 November 1999
Engineering
Issued 2 June 1998 Resolved
MAIN COOLING LINE FOR AUXILARY ENGINE HAS BEEN REPAIRED WITH A SOFT PATCH.
Condition: Unknown
Due 2 August 1998
Resolved 8 October 1998
Engineering
Issued 2 June 1997 Resolved
MAIN COOLING LINE FOR AUXILIARY ENGINE HAS SOFT PATCH. MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Deck/Cargo
Issued 2 June 1997 Resolved
EMERGENCY STOP IN CARGO CONTROL ROOM FOR STEAM TURBINE CARGO PUMPS NOT WORKING PROPERLY. EMERG. STOP ACTIVATES TRIP, BUT TURBINES CONTINUE TO RUN.
Condition: Unknown
Due 16 February 1999
Resolved 16 February 1999
Deck/Cargo
Issued 26 September 1996 Resolved
PRIOR TO TRANSFER OF CARGO IN U.S. WATERS, MAKE PERMANENT REPAIRS TO #5C_x001C_ DEEP WELL CARGO PUMP TO SATISFACTION OF COGNIZANT COTP.
Condition: Unknown
Due 6 November 1996
Resolved 6 November 1996
Engineering
Issued 12 June 1995 Resolved
MAKE PROPER AND PERMENANT REPAIRS TO THE MAIN ENGINE COLLING LINE AT THE COLLING WATER PUMP, LOWER LEVEL E/R. CURRENTLY PATCHED WITH 16 CLAMPS HOLDING TEMP REPAIRS IN PLACE. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 7 August 1995
Resolved 7 August 1995
Deck/Cargo
Issued 21 June 1994 Resolved
PROVIDE PROPER MAINTENANCE/CLEANING OR RENEW ALL FLAME SCREENS FOR ALL CARGO TANKS PER 46CFR30.10-25.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Fire Fighting
Issued 21 June 1994 Resolved
MAKE PROPER REPAIRS TO THE TOP OF THE FOAM STORAGE TANK WHERE WASTED PER SOLAS II-2 REG 21 (SOLAS 74 AMENDED)
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Fire Fighting
Issued 21 June 1994 Resolved
PROVIDE NEW FIRE CONTROL PLAN AT STBD SIDE MAIN DECK LOCATION PER SOLAS 74 (AS AMENDED) REG 20
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Deck/Cargo
Issued 9 December 1992 Resolved
REPAIR HOLES IN BOTTOM OF, AND RESECURE TO DECK, ALL DEFICIENT PORTIONS OF THE PORT CARGO MANIFOLD CONTAINMENT SYSTEM. VESSEL MAY NOT CONDUCT TRANSFER OPERATIONS WITH THE PORT CARGO MANIFOLD UNTIL PROPERLY REPAIRED. THESE ITEMS TO BE COMPLETED PRIOR TO ENTERING NEXT U.S. PORT.
Condition: Unknown
Due 9 December 1992
Resolved 9 December 1992
Fire Fighting
Issued 9 December 1992 Resolved
REPAIR OR REPLACE FORWARD TWO FOAM MONITORS AND ASSOCIATED PIPING. TEMPORARY MONITORS TO REMAIN ONBOARD UNTIL COMPLETION OF REPAIRS. THIS ITEMTO BE COMPLETED PRIOR TO ENTERING NEXT U.S. PORT.
Condition: Unknown
Due 9 December 1992
Resolved 9 December 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.