MAURY USCG vessel records
← All vessels

KNOT RIGHT

Built
1985
Last inspected
31 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN7564
264856
Flag
UNITED STATES
Maury page id
psix-264856

Documentation record

Registered dimensions (L × B × D)43.8 ft × 14.8 ft × 8.0 ft
Registered tonnagegross 34 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFF'S BOAT REPAIR · BAYVILLE, NJ, UNITED STATES · built 1985
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY, FL
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Simplified, Gross Ton
27 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 24 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 24

31 March 2026 Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8338870
17 March 2026 Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 8327986
25 March 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8099431
28 January 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8070393
29 May 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7922517
12 March 2024 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7872703
4 May 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7681132
23 March 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7648222
24 January 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7626237
29 June 2022 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 7503820
2 March 2022 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7404443
9 February 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7394340
19 July 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7260986
10 February 2021 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7138899
13 January 2021 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7123719
15 January 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6890615
16 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6835839
27 March 2019 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6644396
14 November 2018 Drydock Exam · Administrative Inspection · Damage Survey · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580475
19 March 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6372944
7 February 2018 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6351429
29 March 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6110283
27 February 2017 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6093320
25 May 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5885727

Deficiency record · 10

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 March 2024 Resolved
All submersible electrical bilge pumps must be operational. The pump located in the forward compartment does not operate with the manual lever or the float switch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2024
Resolved 29 May 2024
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 March 2024 Resolved
The vessel must have a VHF-DSC radio that is properly installed. The radio must be GPS capable or linked to a GPS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2024
Resolved 29 May 2024
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 March 2024 Resolved
Emergency instructions shall be posted and/or available for crew. There are no instructions on board containing instructions on what to do in the event of an emergency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2024
Resolved 29 May 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 March 2024 Resolved
Machinery space supply/exhaust ducts must have the ability to be closed in the event of an emergency. The space has two 3" scoops that have no closure devices.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2024
Resolved 29 May 2024
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 March 2023 Resolved
Provide record of current drills. Current drills were not provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2023
Resolved 4 May 2023
Resolution: Drill records provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 March 2023 Resolved
Inspect first aid kit. Satisfactory first aid kit was not provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2023
Resolved 4 May 2023
Resolution: First aid kit provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 March 2023 Resolved
Comply with requirements of the Federal Communications Commission. Current FCC documents were not provided.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 4 May 2023
Resolution: FCC documents provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 March 2023 Resolved
Comply with requirements of the Federal Communications Commission. DSC VHF radio function was not programmed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 4 May 2023
Resolution: DSC VHF Radio programmed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2019 Resolved
Vessel was not made available to conduct in-service inspection. Vessel is prohibited from carrying passengers overnight until vessel completes in-service inspection to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 October 2019
Resolved 24 October 2019
Resolution: Vessel completed In-Service inspection, no deficiencies
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 November 2018 Resolved
Due to structural damages sustained during Hurricane Michael a repair plan must be submitted to MSD Panama City detailing proposed repairs prior to starting work. All repairs are to be verified by an attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2019
Resolution: Verified all repairs were comleted during drydock.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.