Inspection history · 32
9 June 2026
Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8405327
10 March 2026
COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8319041
18 April 2025
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8114003
27 January 2025
Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8070364
19 June 2024
Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7939321
10 May 2024
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7932419
18 January 2024
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7851515
28 March 2023
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7658666
9 January 2023
Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7618508
6 June 2022
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7470196
25 March 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7418764
4 February 2022
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7391078
10 September 2021
Deficiency Check · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7309206
23 August 2021
Administrative Inspection · Damage Survey
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7298184
7 April 2021
Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7170673
5 March 2021
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7148060
21 January 2021
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7127783
9 June 2020
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6923424
9 January 2020
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6885873
14 August 2019
Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6796054
11 March 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6629918
7 January 2019
Drydock Exam · Hull Examination · Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6606773
2 October 2018
Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6553078
28 March 2018
Deficiency Check · Annual Inspection · Administrative Inspection · Examination of Repairs · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6370640
14 December 2017
Administrative Inspection · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6324373
27 October 2017
Drydock Exam · Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6295998
22 July 2017
Examination of Repairs · Damage Survey
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6219478
29 June 2017
Damage Survey
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6205694
16 February 2017
Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6083387
11 March 2016
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5831399
8 March 2016
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5832925
1 March 2016
Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5826110
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 June 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Replace broken forward engine mounts on starboard engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 June 2026
Resolution: New STBD shaft and engine mounts installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 April 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
The visual alarm at the operating station was inoperative.
Action required: 705 - Other - as specified
Resolved 18 April 2025
Resolution: New operable light was installed immediately after the inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 June 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must: (3) Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space.
Stbd engine would not shut down.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 13 June 2022
Resolution: Found wire loose at controller. Operational test was satisfactory
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 June 2022
Resolved
Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and (2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
Missing 4 flares and marked water tight container.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 13 June 2022
Resolution: Vessel got the missing flares and placed in the vicinity of the operation station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 June 2022
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
no fire buckets were present on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 13 June 2022
Resolution: placed fire buckets in service
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 8 June 2022
Resolved
A loading mark required by paragraph (c)(2) of this section must be a horizontal line of at least 205 millimeters (8 inches) in length and 25 millimeters (1 inch) in height, with its upper edge passing through the point of maximum draft. The loading mark must be painted in a contrasting color to the sideshell paint.
Loading marks are missing.
no fire buckets were present on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 30 June 2022
Resolution: Loading mark add as per stability letter
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 June 2022
Resolved
If posting is impracticable, such as in an open boat, the certificates must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request.
Missing original COI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 30 June 2022
Resolution: COI placed onboard the vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 June 2022
Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable.
EPIRB not being tested or logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 13 June 2022
Resolution: EPIRB tested and logged
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 June 2022
Resolved
Abandon ship, man overboard, fire drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics.
Drills not conducted or documented.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 13 June 2022
Resolution: MOB and fire drills conducted and logged
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 June 2022
Resolved
The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84)
Vessel did not have day shapes present on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 13 June 2022
Resolution: Day shapes are placed in service
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 June 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
Missing equivalent contents or 160.041 first aid kit.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 13 June 2022
Resolution: Approved first aid kit placed in service
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 June 2022
Resolved
Bells and gongs shall be made of corrosion-resistant material and designed to give clear tone.
Bell missing mounting surface.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 13 June 2022
Resolution: Bell mounting bracket was installed
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 June 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables.
Missing above nautical publications.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 13 June 2022
Resolution: Missing nautical publications placed in service
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 June 2022
Resolved
Every vessel equipped with an inflatable survival craft must have approved placards or other cards containing instructions for launching and inflating inflatable survival craft for the information of persons on board posted in conspicuous places by each inflatable survival craft.
Missing IBA launching instruction.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 13 June 2022
Resolution: placed launching instruction in the galley area.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 8 June 2022
Resolved
Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request.
No shore side passenger count available.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 13 June 2022
Resolution: Contact number added to dock signs to call for passenger count
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 June 2022
Resolved
A hydrostatic release unit when used in a float-free arrangement must be approved under approval series 160.062 or 160.162 or other standard specified by the Commandant.
Hydrostatic release was improperly configured. Instructed the crew on proper configuration.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 8 June 2022
Resolution: Conducted on the spot training and properly configured hydrostatic release.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 8 June 2022
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Acceptable methods of securing the device include - (1) Closing the seacock and removing the handle; (2) Padlocking the seacock in the closed position.
Sewage ovbd was not properly secured. O/O locked it during the exam.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 June 2022
Resolution: Sewage Ovbd was locked.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 June 2022
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.
Station license has incorrect operator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2022
Resolved 13 June 2022
Resolution: Vessel received a new station license
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2022
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
Wrong donning placard was posted
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 13 June 2022
Resolution: Correct donning placard posted
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 25 March 2022
Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel's COD is currently expired with the wrong owner. Vessel owner to present proof of valid COD. 46 CFR 67.7
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2022
Resolved 5 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 August 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The port main diesel engine vibrates excessively at low RPM's (<1000 RPM). Port main diesel engine requires adjustment/alignment to ensure proper operation under all loads/RPM's.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2021
Resolved 10 November 2021
Resolution: Engine was realigned and sea trialed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 August 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Water ingress noted IWO port propellor shaft seal.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2021
Resolved 10 November 2021
Resolution: Shaft seal replaced
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 April 2021
Resolved
Vessel required to be equipped with fixed fire fighting system or as an alternate, a pre-engineered fire extinguishing system. Existing pre-engineered fire extinguishing system alarms/shut downs were inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 November 2021
Resolution: Attending Inspector(s) verified installation of (new) pre-engineered fire extinguishing system and witnessed satisfactory operational test.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 March 2021
Resolved
Vessel is required to be equipped with an operable VHF-FM radio-telephone. Existing VHF-FM radiotelephone is not properly programmed with MMSI ID#.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2021
Resolved 7 April 2021
Resolution: MMSI # programmed into radio
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2021
Resolved
Vessel is required to be equipped with a sound producing device. Existing horn was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2021
Resolved 7 April 2021
Resolution: Vessel's horn was operational
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 March 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2021
Resolved 5 April 2021
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 August 2019
Resolved
Grind/fill/install glass (FRP) IWO starboard hull approx. 2' from stem. Install extra layers of glass (FRP) along the bottom of each hull (from stem to approx. 8' aft) to accomodate beaching operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2019
Resolved 16 September 2019
Resolution: Attending Inspector(s) verified repairs made to port/starboard sponsons/hulls.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 August 2019
Resolved
Vessels starboard main engine shaft seal failed to seal properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2019
Resolution: Attending Inspector verified installation of starboard shaft seal. Witnessed satisfactory operational test.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 January 2019
Resolved
Wear noted IWO port & starboard hull(s) due to beaching operations. The wear extends approximately 8-10' aft of the stem (measured aft) of both the port & starboard hull(s).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 16 January 2019
Resolution: Attending Inspector(s) verified repairs made IWO port/starboard sponsons.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 January 2019
Resolved
Water seepage noted in port hull IWO shaft tube/strut. Affected area to be ground for further inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 16 January 2019
Resolution: Attending Inspector(s) witnessed condition of hull following removal of outer layers of FRP, all sat.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 7 January 2019
Resolved
Deterioration identified IWO flex hose between sewage discharge pump and tank suction.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 11 March 2019
Resolution: Attending Inspector(s) verified installation of new hose assembly IWO sewage pump/tank suction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 January 2019
Resolved
Deterioration noted IWO flex hose connection between transom & exhaust piping (FRP) for starboard main diesel engine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 11 March 2019
Resolution: Attending Inspector(s) verified installation of new flex hose assembly IWO exhaust system for stbd main diesel engine.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 January 2019
Resolved
Machinery space access cover IWO starboard hull required repair to mounting hardware (missing/loose).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 11 March 2019
Resolution: Attending Inspector(s) witnessed repairs made to starboard machinery space cover.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 January 2019
Resolved
Stern light socket required repair/replacement due to deterioration/missing components.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 11 March 2019
Resolution: Attending Inspector performed operatinal test of (new) stern light assembly, test sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2018
Resolved
Gouges/delamination noted IWO port quarter side shell @ transom.
Action required: 705 - Other - as specified
Due 2 November 2018
Resolved 2 November 2018
Resolution: Attending Inspector(s) verified repairs made IWO port qtr.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2018
Resolved
Gouges noted IWO starboard quarter side shell @ transom.
Action required: 705 - Other - as specified
Due 2 November 2018
Resolved 2 November 2018
Resolution: Attending Inspector(s) verified repairs made IWO starboard qtr.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2018
Resolved
Effect permanent repairs IWO port (outboard) window stanchion due to rot.
Action required: 705 - Other - as specified
Due 2 November 2018
Resolved 7 January 2019
Resolution: Attending Inspector(s) verified final repairs made IWO port window stanchion (outboard).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2018
Resolved
Grind FRP IWO port inboard window stanchion for further inspection due to potential rot.
Action required: 705 - Other - as specified
Due 2 November 2018
Resolved 7 January 2019
Resolution: Attending Inspector(s) witnessed final repairs IWO port window stanchion (inboard).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2018
Resolved
Gouges noted IWO port stem.
Action required: 705 - Other - as specified
Due 2 November 2018
Resolved 2 November 2018
Resolution: Attending Inspector(s) verified repair made IWO port stem.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2018
Resolved
Gouges noted IWO starboard stem.
Action required: 705 - Other - as specified
Due 2 November 2018
Resolved 2 November 2018
Resolution: Attending Inspector(s) verified repairs made IWO starboard stem.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2018
Resolved
Erosion of weldments noted IWO port aft peripheral hand railing @ base.
Action required: 705 - Other - as specified
Due 2 November 2018
Resolved 11 March 2019
Resolution: Attending Inspector(s) witnessed repairs made IWO aft peripheral raiings.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2018
Resolved
Grind FRP IWO starboard qtr @ transom (inboard) for further inpsection due to potential rot.
Action required: 705 - Other - as specified
Due 2 November 2018
Resolved 2 November 2018
Resolution: Attending Inspector(s) verified repair made IWO starboard qtry @ transom.
Construction/Loadline › Structures › Superstructure
Issued 28 March 2018
Resolved
Attending Inspector(s) called out fractured stanchion IWO port outboard front window.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 4 May 2018
Resolution: Attending Inspector(s) witnessed temporary repairs IWO port window stanchion.
Documentation › Markings/Placards › Warning Signs
Issued 28 March 2018
Resolved
Vessels emergency escape(s) were not properly marked/identified.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 4 May 2018
Resolution: Attending Inspector(s) witnessed installation of Emergency Escape markings.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 28 March 2018
Resolved
Emergency instructions were not posted/carried on board.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 4 May 2018
Resolution: Attending Inspector(s) verified the carriage/posting of Emergency Instructions.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 March 2018
Resolved
Vessels owner/operator had not developed/implemented EAP (program).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2018
Resolution: Attending Inspector(s) verified implementation of EAP (program).
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 March 2018
Resolved
Vessel did not carry current/up to date navigational publications for areas transited.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 4 May 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
Communications › Audible Communications › Horn/Whistle
Issued 28 March 2018
Resolved
Vessels sound producing device (horn) was inoperable at the time of the inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 4 May 2018
Resolution: Attending Inspector(s) verified repairs made to ship's whistle and performed operational test.
Construction/Loadline › Structures › Deck Plating
Issued 17 November 2017
Resolved
Sand the fiberglass back on the main deck IWO centerline under the bar area due to a fracture; make repairs as necessary.
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 20 February 2018
Resolution: Attending Inspectors witnessed final repairs to main deck (aft bar/serving area).
Engineering › Fuel Oil Service System › Hose
Issued 17 November 2017
Resolved
The fuel return hose from the stbd main engine is a non-approved type; replace the fuel hose between the stbd main engine and the port fuel tank with an approved type (SAE J1942).
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 14 December 2017
Resolution: Attending Inspector(s) witnessed installation of fuel lines IWO port/starboard sponsons.
Construction/Loadline › Hull › Hull Plating
Issued 22 July 2017
Resolved
Starboard stem (FRP) was damaged as a result of a collision with a recreational vessel (cosmetic only).
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 24 July 2017
Resolution: Attending Inspector verified repairs made to starboard stem.
Communications › Radio Communications › VHF Radiotelephone
Issued 16 February 2017
Resolved
VHF-FM marine radio not programmed with vessels MMSI number (DSC equipped).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 24 February 2017
Resolution: Attending Inspector verified new VHF-FM radio installation.
Engineering › Bilge Water Management System › Not Operational
Issued 16 February 2017
Resolved
Starboard aft sponson bilge pump inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 24 February 2017
Resolution: Attending Inspector verified repairs made to starboard aft sponson bilge pump. Performed operational test, test sat.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 February 2017
Resolved
Starboard fuel fill bonding/grounding strap disconnected due to clamp wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 24 February 2017
Resolution: Attending Inspector verified re-connection of grounding strap in way of starboard fuel fill.
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 February 2017
Resolved
Emergency fuel shut off valves were not properly marked with operating instructions.
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 24 February 2017
Resolution: Attending Inspector verified markings for remote fuel shut off valves.
Communications › Alarms/Indicators › High Water Alarm
Issued 16 February 2017
Resolved
High water alarms were not properly marked (spaces served).
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 24 February 2017
Resolution: Attending Inspector verified markings for bilge high water alarms.