MAURY USCG vessel records Sign in
← All vessels

SANTA FRANCISCA

SANTA FRANCISCA is a 2001 freight ship. The Coast Guard has recorded 24 inspections since 2001, most recently in August 2014, along with 14 deficiencies — 1 with no resolution recorded — and 1 operational control, 1 with no removal date recorded.

Records from 2001 to 2014. Most recent: inspection, 8 August 2014.

Built
2001
Last inspected
8 August 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9248198 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-26556

Inspections, by type

…with no type recorded7
Years with a record 10 calendar years (2001–2014)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it28494 - Dead Weight, Ton
16941 - Convention (Subpart B), Gross Ton
10498 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BOSPHORUS ASIA Freight Ship · MISLE 586992 · 10 August 2002 · activity 1662108EX "JODY K" Commercial Fishing Vessel · MISLE 666221 · 10 August 2002 · activity 1662108

Inspection history · 24

8 August 2014 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4948415
30 July 2012 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4396423
22 January 2010 PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3665014
13 December 2008 ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3376248
30 October 2008 Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3350245
3 April 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3176867
24 August 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2758429
3 July 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2700013
28 April 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2635844
9 March 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2599572
23 February 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2590966
7 November 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2530147
7 July 2005 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2418863
24 March 2005 PII Safety Exam · ISPS III Exam
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2319838
18 November 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2243638
9 August 2004 PII Safety Exam · ISPS II Exam
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2161958
17 April 2004 Re-Inspection
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2047794
7 November 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1941846
10 September 2003 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1900717
28 May 2003 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1801915
10 August 2002 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1662108
10 June 2002 MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1626661
16 February 2002 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1486708
14 May 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 289933

Deficiency record · 14

Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 22 January 2010 Resolved
2050 Emergency generator not able to be readily started using a second source of energy. Crew was able to successfully start emergency generator utilizing #2 battery bank, but generator fail to start when crew switched to #1 battery bank. See scanned Form B for full description. SOLAS74 (01cons) ch. II-1 reg. 44.2 30ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2010
Resolution: Deficiency cleared due to satisfactory class survery report.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 30 October 2008 Resolved
Class A Fire door leading to engine room is missing gasket and fitted with hold back hook. Door is required to be reasonably gas tight and not fitted with hold back hook.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 December 2008
Resolution: Door repaired to the satisfaction of Class.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 30 October 2008 No resolution recorded
#2 Fuel oil purifier and #2 fuel oil transfer pump have gross leaks of fuel oil. Associated lagging is saturated and containment is insufficient.
Condition: Unknown
Action required: 705 - Other - as specified
Resolution: Necessary components repaired to the satisfaction of Class.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 30 October 2008 Resolved
Fire locker and all associated equipment consolidated with second fire locker. Current arrangementn is not indicated in approved fire control plan.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 30 October 2008
Resolution: Moved fire locker to correct area as designated in fire control plan.
Engineering › Bilge Water Management System › Pump
Issued 30 October 2008 Resolved
Bilge ballast pump, fire general service pump, salt water cooling pump, and steamline valve all excessively leaking and causing standing water.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 December 2008
Resolution: Necessary components repaired to the satisfaction of Class.
Operations/Management › Drills/Instruction › Fire
Issued 28 April 2006 Resolved
Crew lacked proficiency and understanding in ship board fire fighting drill. SOLAS 2004 III/19.3.4 Satisfaction of Coast Guard
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 December 2016
Resolved 20 December 2016
Resolution: Deficiency entered in error. [name withheld]
Operations/Management › Drills/Instruction › Fire
Issued 28 April 2006 Resolved
Crew lacked proficiency and understanding in fire drill. STCW CH. 6 Section A-6/1 to the satisfaction of Class Society
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 July 2006
Resolution: As per NKK''s report "According to the master of the ship, he had a meeting for educating crew members on the fire drill & other things on fire fighting and recorded it''s meeting topics.The crew was found well educated on the drill through the interview.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 9 August 2004 Resolved
Hospital room toilet inoperable
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2004
Resolution: Witnessed satisfactory operation of toilet.
Fire Fighting › Fire Hoses › Condition
Issued 9 August 2004 Resolved
Provide two (2) additional hoses to replace two ruptured ones during drill ivo port and starboard quarterdeck.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 November 2004
Resolution: Recieved fax of recept for hoses.
Documentation › Certificates/Documents
Issued 10 September 2003 Resolved
Include all of the tanks in block 3 of the IOPP under the C-11 entries into the oil record book. MARPOL 73/78 I. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 November 2003
Documentation › Logs/Records
Issued 10 September 2003 Resolved
Commence making entries into the oil record book under C-2 as per the instructions found in MARPOL 73/78 Appendix I. Where the quantity of contents retained has not been recorded. LEGACY COMPONENT DESC: Oil Record Book
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 November 2003
Documentation › Logs/Records
Issued 10 September 2003 Resolved
Record all operations separately in the oil record book where now all transfers and incinerations are combined between tanks. MARPOL 73/78 I. LEGACY COMPONENT DESC: Oil Record Book
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 November 2003
Resolution: Recieved Class Report.
Engineering › Lubricating Oil Storage/Transfer System
Issued 10 September 2003 Resolved
Provide protection of oil system. SOLAS 74 and II-2/1529-12
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 November 2003
Resolution: Recieved Class report
Documentation › Manuals/Policy Documentation
Issued 10 June 2002 Resolved
Provide oil transfer procedures that meet the requirements of 33 CFR 155.750 prior to transferring oil products internally or externally, in U.S. waters. LEGACY COMPONENT DESC: Transfer Procedures
Due 11 June 2002
Resolved 11 June 2002

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.