THE PEARL BUTTON

THE PEARL BUTTON is a 1985 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1985, most recently in March 2017, along with 116 deficiencies and 1 operational control.

Records from 1985 to 2017. Most recent: inspection, 30 March 2017.

Built
1985
Last inspected
30 March 2017
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF4205
266091
Flag
UNITED STATES
—
Maury page id
psix-266091

Inspections, by type

…with no type recorded5
Years with a record 30 calendar years (1985–2017)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.0 ft × 24.0 ft × 4.0 ft
Registered tonnagegross 92 / net 92
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderV E GRAY INC · NEWPORT, MN, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMUSCATINE, IA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
92 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 60

30 March 2017 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6114625
28 March 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6113308
8 March 2017 Spot Check · Internal Structural Exam · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6101637
1 February 2017 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6081212
4 October 2016 Examination of Repairs · Hull Examination · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6017076
20 July 2016 Spot Check · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5947531
3 June 2016 Annual Inspection · MARPOL Annex IV Survey · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5898806
28 July 2015 Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5199113
22 July 2015 Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5194275
17 July 2015 Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5187244
13 August 2014 Annual Inspection · Administrative Inspection · MARPOL Annex VI Survey · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4965705
9 July 2012 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4375212
5 June 2012 Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4335553
8 May 2009 Type not recorded
No type recorded · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3470170
6 May 2009 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection · Excursion Permit · MARPOL Annex VI Survey · In-Service Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3468950
10 September 2008 Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3323502
23 May 2008 Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3218652
22 April 2008 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3187189
1 June 2007 Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2962979
27 April 2007 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2914535
11 October 2006 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2799918
16 May 2006 Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2649772
6 June 2005 COI Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2383817
2 August 2004 Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2133922
22 July 2004 Administrative Inspection
Administrative · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2141338
14 July 2003 Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1874320
9 October 2002 Hull Examination
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1724562
28 May 2002 Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1654301
10 May 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1379517
9 September 2000 Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 5851
22 June 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1051859
2 May 2000 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1443008
10 May 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1418616
11 May 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1461048
24 September 1997 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1464716
27 April 1997 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1452283
15 May 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1400362
26 April 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1443567
1 August 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 863327
27 April 1994 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 857975
20 October 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 840805
12 May 1993 Re-Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 833215
8 October 1992 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1259811
24 April 1992 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1251964
2 May 1991 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1217379
23 July 1990 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1238141
2 May 1989 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1344976
18 July 1988 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1031880
11 July 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 897573
2 May 1988 Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1035889
5 January 1988 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1314981
14 October 1987 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1323858
20 July 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1329696
11 June 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1030339
8 June 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1336252
4 May 1987 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1324553
19 August 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 991150
13 May 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 990260
30 April 1986 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 985273
15 May 1985 COI Inspection · Credit Drydock
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1299919

Deficiency record · 116

Engineering › Bilge Water Management System › Piping
Issued 9 March 2017 Resolved
Bilge suction line fractured due to lack of winterization in starboard & port void spaces.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2017
Resolved 10 April 2017
Resolution: Vessel has been taken out of service
Stability › Watertight Integrity › General
Issued 1 February 2017 Resolved
Port and Starboard pontoons are required to be tested to 1 1/2 psi to ensure water tight integrity
Action required: 705 - Other - as specified
Due 1 February 2017
Resolved 1 February 2017
Resolution: Pontoons were tested at 1.5 psi and held for 15 minutes to prove water tight integrity.
Engineering › Bilge Water Management System › Not Operational
Issued 3 June 2016 Resolved
Vessel high level alarms in C1, S2, and P2 are inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 23 June 2016
Resolution: Vessel owner installed new wiring and high level alarms. Vessel owner also installed new visual and auidable indicators in the operation station.
Stability › Watertight Integrity › General
Issued 13 August 2014 Resolved
Wing voids on either side of the fuel tank void have 4"x6" soft patches that need to be removed and have permanant patches installed in place to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 October 2014
Resolved 22 September 2014
Resolution: Voided CG-835 and reissued with extension
Electrical › Electric Supply System (service) › Cable
Issued 13 August 2014 Resolved
Electrical supply cord on motor to diaphram tank is worn at the conection to the motor and presents an electrical hazard to the crew. Replace to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2014
Resolved 15 August 2014
Resolution: Provided Pictures of repairs that appeared sat, will schedule a on scene verification at future date.
Electrical › Electric Supply System (service) › Cable
Issued 13 August 2014 Resolved
Electrical cord on motor to diaphram tank is excessive in length and needs to be lifted off the deck and shortened to prevent tripping and electrical hazard to crew.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 September 2014
Resolved 15 August 2014
Resolution: Provided Pictures of repairs that appeared sat, will schedule a on scene verification at future date.
Electrical › Electric Supply System (service) › Cable
Issued 13 August 2014 Resolved
In starboard engine room void space, unprotected electrical cable passes through bulkhead penetration, chaffing or protective gear is required to protect cable from creating an undue electrical hazard to crew.
Condition: Improper Installation
Due 13 September 2014
Resolved 15 August 2014
Resolution: Provided Pictures of repairs that appeared sat, will schedule a on scene verification at future date.
Electrical › Electric Supply System (service) › Cable
Issued 13 August 2014 Resolved
Two electrical extension cords in the galley must be removed from service.
Condition: Improper Installation
Due 13 September 2014
Resolved 15 August 2014
Resolution: Provided Pictures of repairs that appeared sat, will schedule a on scene verification at future date.
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 9 July 2012 Resolved
Reduce total number of persons allowed onboard to 91 adults and 8 children until lifejackets are provided for total 120 passengers and 11 children.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 2 August 2012
Resolution: Added added 49 adult life jackets for a total of (120 required ) 140 adult life jackets and added 10 children life jackets for a total of 11 required )18 Children on board.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 July 2012 Resolved
Stowage space on 2nd Deck must be clearly marked for lifejackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 2 August 2012
Resolution: Stowage space on 2nd Deck is clearly marked for lifejackets.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 9 July 2012 Resolved
Alcohol Testing Devices onboard are expired and must be replaced.
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 2 August 2012
Resolution: Alcohol Testing Devices onboard are not required as long as crewmember can be conducted tested within 2 hours of a serious marine Incident
Construction/Loadline › Structures › Scuttle
Issued 9 July 2012 Resolved
Make all Void covers watertight prior to the carriage of passengers, repairs must be to the satifaction of the attending Coast Guard Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 August 2012
Resolution: All Void covers have been made watertight
Stability › Watertight Integrity › Weathertight Enclosure
Issued 5 June 2012 Resolved
Bulkhead between 5C AND 5P found not watertight. Remove caulk and repair with permanent repair
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 July 2012
Resolution: Bulkhead between 5C AND 5P found not watertight. Removed caulk and repaired with permanent repair
Stability › Watertight Integrity › Weathertight Enclosure
Issued 5 June 2012 Resolved
Vessel potable water service pipe through bulkhead 4C AND 5C caulked and not metal. Repair with permanent materials
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 9 July 2012
Resolution: Vessel potable water service pipe through bulkhead 4C AND 5C caulked and not metal. Repaired with permanent materials
Construction/Loadline › Markings › Load Line Mark
Issued 10 May 2010 Resolved
Mark minimum freeboard lines as per stability letter forward amidships, and aft of vessel. Lines must be horizontal at least 8 inches in length and 1 inch in height.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Marked minimum freeboard lines as per stability letter forward amidships, and aft of vessel. Lines must be horizontal at least 8 inches in length and 1 inch in height.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 10 May 2010 Resolved
Prove proper operation of Starboard Engine and Jetpack
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 May 2010
Resolution: Proved proper operation of Starboard Engine and Jetpack
Stability › Incline Test › General
Issued 6 May 2009 Resolved
Vessel did not meet the conditions of the stability letter. Vessel required to engage with Marine Architect. Marine Architect engaged with MSC and determined that the stability letter was invalid. New stability letter must be issued.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 6 November 2009
Resolution: MSC and marine architect redid calculations for the vessel and issued a new stability letter.
Stability › Intact Stability (when using lifting gear) › General
Issued 6 May 2009 Resolved
New stability calculations included addition of foam blocks to the aft compartment. Foam blocks need to be installed prior to operation of the vessel
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2010
Resolution: All foam blocks have been installed in accordance with the new stability latter
Fire Fighting › Combustible Materials › Insulation
Issued 6 May 2009 Resolved
Remove port and starboard wood paneling and styrofoam insulation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Engineering › Bilge Water Management System › Not Operational
Issued 6 May 2009 Resolved
Prove proper operation of vessel's bilge system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 May 2010
Resolution: Tested vessels bilge system-all Sat
Fire Fighting › Nozzles › Condition
Issued 6 May 2009 Resolved
Prove operation of vessel's fire nozzle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Resolution: Fire nozzle was replaced.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 6 May 2009 Resolved
Ensure port and starboard fuel tanks are vapor and fuel tight/ clean fuel tanks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Port and starboard fuel tanks are vapor and fuel tight./cleaned
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 6 May 2009 Resolved
Install high level bilge alarms in all voids with through hull fittings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Construction/Loadline › Structures › Scuttle
Issued 6 May 2009 Resolved
Ensure all non-watertight main deck hatches are accessible. Currently sealed underneath carpet.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 6 May 2009 Resolved
Ensure that the sewage tank lids located in the head area are sealed and vapor tight and that the sewage tank is vented outside the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Engineering › Lubricating Oil Service System › Hose
Issued 6 May 2009 Resolved
Repair hydraulic oil leaks in both port and starboard engine rooms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 6 May 2009 Resolved
Remove all flammables and wooden cabinets from vessel's engine rooms.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 6 May 2009 Resolved
Replace 8 unserviceable PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2009 Resolved
Replace all non-U/L wiring with marine approved ones.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Engineering › Steering Gear System › Valve
Issued 6 May 2009 Resolved
Properly support port engine steering manifold valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Deck/Cargo › Holds/Tanks › Ventilation Air Intake
Issued 6 May 2009 Resolved
Ensure all voids are vented.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: All voids are vented
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 6 May 2009 Resolved
Ensure that the vessel's bilge piping system is configured as per vessel's original plans.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Ensured that the vessel''''''''s bilge piping system is configured as per vessel''''''''s original plans.
Engineering › Freshwater System (jacketwater cooling) › Charging Tank
Issued 6 May 2009 Resolved
Install metal lid with latch on engine room bulkhead antifreeze and oil reservoir tanks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Installed metal lid with latch on engine room bulkhead antifreeze and oil reservoir tanks.
Engineering › Lubricating Oil Service System › Hose
Issued 6 May 2009 Resolved
Replace starboard engine room chafed and leaking hydraulic oil line
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Engineering › Pressure Vessel › Relief Valve
Issued 6 May 2009 Resolved
Replace or have the repair certified by the approved vessel repair facility. Unapproved weld on the pressure vessel for the vessel's air horn.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 May 2009 Resolved
Properly install the port and starboard fuel shutoff valves.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Properly installed the port and starboard fuel shutoff valves.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 May 2009 Resolved
Repair the deteriorated starboard stern light post.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 May 2009 Resolved
Segregate and properly mark child and adult size PFD lockers. Each child lifejacket must be stored in a location properly marked and segregated from adult lifejackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Segregated and properly marked child and adult size PFD lockers. Each child lifejacket is stored in a location properly marked and segregated from adult lifejackets.
Engineering › Generator (propulsion-electric) › Ground Conductor
Issued 6 May 2009 Resolved
Install water temperature gauge, oil pressure gauge, and frequency meter on the generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 May 2010
Resolution: Installed water temperature gauge, oil pressure gauge, and frequency meter on the generator.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2009 Resolved
Properly support with metal strap every 24 inches, vessel's wires and cables from integral part of the hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Properly supported with metal strap every 24 inches, vessel''s wires and cables from integral part of the hull.
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 May 2009 Resolved
Properly secure the engineroom steering fluid lines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 May 2009 Resolved
Ensure the wire splices for the engine room junction box are inside the box and the box is covered.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2009 Resolved
Remove the abandoned red wire in the overhead starboard engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 May 2009 Resolved
Ensure the engine's dry exhaust piping has no exhaust leaks and is properly insulated and guarded to prevent personal injury.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 May 2009 Resolved
Ensure the vessel's first aid kit meets the requirements of 46 CFR 185.710
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 6 May 2009 Resolved
Install a vessel's bell with a minimum of 200 mm. mouth opening.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Construction/Loadline › Structures › Superstructure
Issued 6 May 2009 Resolved
Properly secure/tighten the first deck hand rail.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Pollution Prevention/Response › Prevention Equipment › Annex VI
Issued 6 May 2009 Resolved
Ensure all waste receptacles are non-combustible
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Ensured all waste receptacles are non-combustible
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 May 2009 Resolved
Cover the exposed outlet behind the second deck bar.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 6 May 2009 Resolved
Prove proper operation of vessel's rudder angle indicator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Resolution: Removed instrumentation, not needed.
Lifesaving › Lifebuoys › Immediately Available
Issued 6 May 2009 Resolved
Ensure life ring-line is stowed so as to be rapidly cast loose and the the clip on the float light is non-corrosive.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 6 May 2009 Resolved
Secure the loose piping in the overhead of the C2 void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Secured the loose piping in the overhead of the C2 void.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 May 2009 Resolved
Ensure the vessel has a current light list.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2009 Resolved
Properly hard-wire/install a outside water-tight outlet box for the third deck string lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Engineering › Non-conventional Propulsion/Steering › Nozzle (jet)
Issued 6 May 2009 Resolved
Label the pilot house jet drive controls.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 May 2010
Resolution: Labeled the pilot house jet drive controls.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 6 May 2009 Resolved
Repair, reconfigure, or replace the starboard engine kinked raw water hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Fire Fighting › Fire Hoses › Condition
Issued 6 May 2009 Resolved
Reconfigure or support the water hose so that it doesn't kink at the valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Reconfigured support for the water hose so that it doesn''t kink at the valve.
Operations/Management › Passenger Operations › Safety Orientation
Issued 6 May 2009 Resolved
Ensure all items in 46 CFR 185-506 are covered in the passenger safety orientation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Engineering › Fuel Oil Service System › Valve, Control
Issued 6 May 2009 Resolved
Install remote fuel shutoff valve at the generator as per 46 CFR 182.20-40 (b) (3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Installed remote fuel shutoff valve at the generator as per 46 CFR 182.20-40 (b) (3)
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 6 May 2009 Resolved
Properly label all vessel PFDs with the name of the vessel with legible block capital letters.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Properly labeled all vessel PFDs with the name of the vessel with legible block capital letters.
Engineering › Non-conventional Propulsion/Steering › Impeller (jet)
Issued 6 May 2009 Resolved
Ensure that the flexible fuel line for the jet pack meets the requirements of 46 CFR 182.455 (a)(1)(iii)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 May 2009
Operations/Management › Passenger Operations › Safety Orientation
Issued 6 May 2009 Resolved
Post placards containing instructions for the donning and use of lifejackets on board. These must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 November 2009
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 May 2009 Resolved
Provide documentation of enrollment in approved DAPI program/consortium.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 May 2010
Resolution: Provided documentation of enrollment in approved DAPI program/consortium.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 6 May 2009 Resolved
Display for employees, required EAP policy statement and hotline number.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Display for employees, required EAP policy statement and hotline number.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 6 May 2009 Resolved
Provide documentation of supervisors receiving the one hour EAP training.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 May 2010
Resolution: Provide documentation of supervisors receiving the one hour EAP training.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 6 May 2009 Resolved
Replace retroreflective material on 10 identified lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2009
Resolution: 10 identified lifejackets removed from service.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 6 May 2009 Resolved
Next drydock, ensure hull marking requirements of 46 CFR 185.602(c) are met.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2012
Resolution: Ensured Hull markings were completed
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 April 2008 Resolved
Battery in Stbd engine room not secured within a tray. Provide battery tray securely holding battery I.A.W. 46 CFR 183.350
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 23 May 2008
Resolution: Battery relocated and placed in new battery tray.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 22 April 2008 Resolved
Label all circuit breakers in C/B box for service intended. 46 CFR 183.220
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 23 May 2008
Resolution: All Circuit breakers labled.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 April 2008 Resolved
Weld broken on upper horizontal stiffner in stb water tnk at forward bulkhead. Grind and reweld stiffner 46 CFR 176.25-5
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 23 May 2008
Resolution: Corrected
Accommodation/Occupational Safety › Ventilation › General
Issued 22 April 2008 Resolved
Clean exhaust fans and louvers in engine rooms. 46 CFR 181
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 23 May 2008
Resolution: Exhaust fans replaced with new ones.
Engineering › Bilge Water Management System › Manifold
Issued 22 April 2008 Resolved
Relabel bilge manifold to identify individual bilge lines in port engine room. 46 CFR 182.510
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 23 May 2008
Resolution: Manifold properly marked.
Stability › Watertight Integrity › General
Issued 22 April 2008 Resolved
Make all penetrations through watertight bulkheads watertight 46 CFR 179.360
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 23 May 2008
Resolution: Pentrations in bulkhead below port main engine packed.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 22 April 2008 Resolved
Replace exhaust lagging where missing for main engine exhaust in port engine room 46 CFR 182.20-20
Action required: 705 - Other - as specified
Due 22 May 2008
Resolved 23 May 2008
Resolution: Lagging replaced
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 April 2008 Resolved
Port navigation light bottom bracket broken repair IAW 33 CFR 83
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2008
Resolution: Navigation light repaired.
Engineering › Diesel Engine (propulsion-direct drive) › Bearing
Issued 22 April 2008 Resolved
Starboard inner bearing for shaft to sidewheel is loose. Secure bearing. 46 CFR 182.05-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2008
Resolution: Bearing tightened, operator got vessel underway with MI observing all sat.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 22 April 2008 Resolved
Chemical testing program does not comply with 46 CFR 16. Provide evidence company fully complies with part 16. Did not meet 46 CFR 16.210, 230, 401, and 500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2008
Resolution: Company has signed up with a Maritime Consortium, received training for EAP rep and has submitted MIS for last years activity.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 27 April 2007 Resolved
Shaft support for starboard paddle is loose, align shaft and secure bolts prior to carrying passengers for hire to the satisfaction of a Coast Guard Inspector. 46 CFR 182.05-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2007
Resolution: Owner verified Pillow block was aligned and tightened.
Fire Fighting
Issued 2 May 2000 Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILLS WHEN NEWLY HIRED CREW IS ONBOARD.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Engineering
Issued 27 April 1994 Resolved
Replace missing starboard engine exhaust lagging as necessary not later than the compliance date.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Lifesaving
Issued 27 April 1994 Resolved
Clean oil as necessary around both main engines and void spaces below the engines not later than the compliance date.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Fire Fighting
Issued 27 April 1994 Resolved
Provide a mounting bracket for the galley fire extinguisher not later than the compliance date.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Lifesaving
Issued 27 April 1994 Resolved
Conduct emergency drills with the assigned vessel crew not later than the compliance date.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Construction/Loadline
Issued 27 April 1994 Resolved
Plug or cap off all unused steering cable wire runs through watertight bulkheads and transom, also insure all penetration plates are sealed as necessary not later than the compliance date.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Construction/Loadline
Issued 27 April 1994 Resolved
Install compression fittings where electrical wiring is penetrating watertight bulkheads as necessary not later than the compliance date.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Construction/Loadline
Issued 27 April 1994 Resolved
Remove unused PVC pipe penetrating watertight bulkheads and seal holes as necessary not later than the compliance date.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Fire Fighting
Issued 27 April 1994 Resolved
Fasten down electric fire pump not later than the compliance date.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Electrical
Issued 12 May 1993 Resolved
Repair or replace broken light fixture in the portside engine room not later than the compliance date.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Engineering
Issued 12 May 1993 Resolved
Provide lagging for the port engine exhaust system not later than the compliance date.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Navigation
Issued 12 May 1993 Resolved
Provide a bell with a minimum size of 7.9 inches not later than the compliance date.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 12 May 1993 Resolved
Conduct underway emergency drills with the assigned vessel crew not later than the compliance date.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Construction/Loadline
Issued 12 May 1993 Resolved
Open integral sewage and fuel tanks for inspection not later than the compliance date.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Construction/Loadline
Issued 12 May 1993 Resolved
Provide hull freeboard marks per the vessel stability letter not later thanthe compliance date.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Accommodation/Occupational Safety
Issued 24 April 1992 Resolved
Replace broken window glass in second deck passenger area not later than the compliance date.
Condition: Unknown
Due 24 April 1992
Resolved 24 April 1992
Engineering
Issued 2 May 1991 Resolved
Provide a bilge pump with the capacity of 25 gallons per minute.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Unknown
Issued 2 May 1991 Resolved
Replace solid core wire from the switch to the sewage pump in the starboardengine room.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1988 Resolved
PROVIDE 6 HAND RED FLARE AND 6 HAND ORANGE SMOKE DISTRESS SIGNAL OR 12 HANDCOMBINATION FLARE AND SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Lifesaving
Issued 2 May 1988 Resolved
PROVIDE PORTABLE WATERTIGHT CONTAINER FOR DISTRESS SIGNALS.
Condition: Unknown
Due 2 May 1988
Resolved 2 May 1988
Construction/Loadline
Issued 14 October 1987 Resolved
SUBMIT PALNS TO MSO ST. LOUIS, MO FOR THE ENCLOSURE OF THE SECOND DECK.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Construction/Loadline
Issued 20 July 1987 Resolved
SEAL OPENINGS IN THE DECK OF THE PORT AND STARBOARD SPONSONS.
Condition: Unknown
Due 20 July 1987
Resolved 20 July 1987
Documentation
Issued 11 June 1987 Resolved
BASED UPON A SIMPLIFIED STABILITY TEST CONDUCTED ON THE M/V ANDIAMO ON 11 JUNE 1987 THE PASSENGER AND STABILITY CRITERIA FOR THE VESSEL ARE AMENDED AS FOLLOWS: TOTAL PASSENGERS=85; TOTAL PERSONS=90. NO MORE THAN 40 PERSONS ALLOWED ON THE SECOND DECK. NO PASSENGERS ALLOWED ON THIRD DECK.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Documentation
Issued 11 June 1987 Resolved
DUE TO UNUSUAL DESIGN OF VESSEL AND WEIGHT MODIFICATIONS TO UPPER DECK A FORMAL INCLINING STABILITY TEST IS REQUIRED TO BE CONDUCTED PRIOR TO RECERTIFICATION OF THE VESSEL ON 15 MAY 1988.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Unknown
Issued 4 May 1987 Resolved
SUBMIT PLANS FOR CHANGE TO EXTERIOR PROFILE.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Unknown
Issued 4 May 1987 Resolved
PROVIDE VALVE EXTENSIONS FOR FIRE PUMP INLET VALVE AND GENERATOR COOLING SYSTEM INLET VALVE.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Fire Fighting
Issued 4 May 1987 Resolved
PROVIDE HAND FIRE PUMP & HOSE.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Unknown
Issued 4 May 1987 Resolved
PROVIDE EXHAUST VENTILATION DUCTS IN BOTH ENGINE COMPARTMENTS.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Documentation
Issued 4 May 1987 Resolved
PROVIDE EVIDENCE OF DOCUMENTATION.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Unknown
Issued 4 May 1987 Resolved
PROVIDE GUARDS OVER COUPLINGS ON HYDRAULIC MOTORS IN ENGINE COMPARTMENTS.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Construction/Loadline
Issued 30 April 1986 Resolved
PROVIDE SET OF HULL PRINTS DETAILING HULL AND COMPARTMENT DIMENSIONS, FUEL TANKS, BILGE/FIRE MAIN PIPING, ETC. OF SUFFICIENT DETAIL TO COMPLETE VESSELPLAN REVIEW AND DETERMINE VESSEL'S FLOODABLE LENGTH CRITERIA.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Lifesaving
Issued 30 April 1986 Resolved
PROVIDE THREE ADULT PFDS.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Fire Fighting
Issued 30 April 1986 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Engineering
Issued 30 April 1986 Resolved
REMOVE C-CLAMPS AND SAFETY BOLT MORSE CONTROL CABLE GUIDES IN BRIDGE CONSOLE HOUSING.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Documentation
Issued 30 April 1986 Resolved
POST EMERGENCY CHECKOFF LIST IN PASSENGER LOUNGE.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Navigation
Issued 30 April 1986 Resolved
COMPLETE INSTALLATION OF AIR HORN.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Electrical
Issued 30 April 1986 Resolved
PROVIDE BATTERY BOX WITH COVER FOR 12 VOLT BATTERY IN WHEELHOUSE.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Construction/Loadline
Issued 15 May 1985 Resolved
MAKE ALL MODIFICATIONS TO TRANSVERSE BULKHEADS AS DETAILED IN [name withheld] LETTER DATED 24 JUNE 1986.
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.