Records from 2001 to 2026. Most recent: inspection, 12 August 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)86.5 ft × 31.2 ft × 9.0 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)86.5 ft × 31.2 ft × 9.0 ft
ITC tonnagegross 243 / net 100
BuilderNICHOLS BROTHERS BOAT BUILDERS INC · FREELAND, WA, UNITED STATES · built 1985
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEWARD, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 11 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
243 - Convention (Subpart B), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
100 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
24 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; 1 other recorded name, with years; 6 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 24
12 August 2026
In-Service Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8462730
21 April 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8329404
20 August 2025
In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8214724
12 April 2025
Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8110433
7 November 2024
Deficiency Check · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8032255
5 September 2024
Deficiency Check · Administrative Inspection · Annual Inspection · In-Service Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7997474
3 August 2023
In-Service Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7759967
5 December 2022
Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7604603
27 October 2022
Plan Review (Other than "T") · Administrative Inspection · Annual Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7596467
7 October 2021
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7328428
15 September 2021
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7313004
23 July 2021
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7268891
28 September 2020
COI Inspection · MTSA Verification · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7067229
11 June 2020
Administrative Inspection · Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6974465
23 September 2019
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6820333
29 May 2019
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6698875
26 April 2018
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6390666
20 February 2018
Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam · Examination of Repairs
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6352080
10 May 2017
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6149668
10 May 2017
Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6149689
8 May 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6137218
28 March 2017
Spot Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6113430
28 April 2016
COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5860541
22 April 2016
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5852059
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 April 2026
Resolved
Provide schematic diagram of the system at the location of the bottle for both engine rooms fixed system in the generator spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2026
Resolved 13 May 2026
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 April 2026
Resolved
Install blanks in distribution panels in both generator spaces prevent a person from accidentally contacting energized parts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 22 April 2026
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2026
Resolved
Install caps or plugs to prevent fuel leakage from port generator fuel filter water removal valve
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2026
Resolved 22 April 2026
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 September 2020
Resolved
Small fire dampers in engine room did not close completely when activated. Repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2022
Resolution: Fire dampers repaired
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 30 September 2020
Resolved
Remove temporary repair in overhead of starboard laz and make available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2022
Resolution: Clad welded pits
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 June 2020
Resolved
Prove proper operation of the bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2020
Resolution: operational test sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 June 2020
Resolved
Ensure proper operations of the STBD engine fuel shut off.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2020
Resolution: repaired
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 12 June 2020
Resolved
Ensure proper operation of the port engine room fire damper .
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2020
Resolution: repaired
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 12 June 2020
Resolved
Port generator space-02 vertical cracks were found on 02 inboard transverse structural members, repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 12 June 2020
Resolution: repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2020
Resolved
Starboard void #3-electrical wire was improperly remaoved. Repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 12 June 2020
Resolution: repaired
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 June 2020
Resolved
COD was found expired. Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2020
Resolution: showed proof of applying for COD
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 June 2020
Resolved
Designation letter for senior deck hands was not on board. Provide.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2020
Resolved 22 June 2020
Resolution: Designated letter provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 June 2020
Resolved
IBA sea painter line was found disconnected on 3 of 4 IBAs. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 12 June 2020
Resolution: corrected on the spot
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 12 June 2020
Resolved
Overboard discharge valve for MSD was found open. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 12 June 2020
Resolution: corrected on the spot
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2020
Resolved
Ensure electrical panels have matting in front. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 12 June 2020
Resolution: corrected on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 June 2020
Resolved
Electric discharge bilge pump was tied into fixed bilge discharge. Remove and properly install system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2020
Resolved 22 June 2020
Resolution: Bilge system tie-in was replaced with a positive action valve.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 June 2020
Resolved
STBD Void #2 - A crack was found in the side shell around support approximately 4" in length located inboard, aft of first frame approximately 8" below deck. Make repair proposal and complete satisfactory repair (temporary repair).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2020
Resolution: repaired
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 April 2018
Resolved
Vessel is restricted to 192 passengers due to reduction in liferaft capacity.
Action required: 705 - Other - as specified
Resolved 30 May 2018
Resolution: Liferafts are back onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2018
Resolved
Replace retroreflective material on lifebuoy
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 30 May 2018
Resolution: repairs satisfactory
Construction/Loadline › Hull › Hull Plating
Issued 11 May 2017
Resolved
Make proper repairs via insert on starboard forward pontoon, inboard side. Fit up has been witnessed however finals have not been.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 27 March 2018
Resolution: Examined/cleared vee & reweld upper fwd corner ~ 8 inches to May 2017 insert.
Stability › Watertight Integrity › General
Issued 8 May 2017
Resolved
Watertight dog on stbd bow door is broken. Vessel required to replace dog to the satisfaction of the attending marine inspector prior to sailing with passengers.
Due 11 May 2017
Resolved 10 May 2017
Resolution: Vessel replaced dog on stbd bow door. Door operates properly. //s// [name withheld]
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 8 May 2017
Resolved
Port side engine room blower damper did not operate properly. Vessel required to show proper operation to the satisfaction of the attending marine inspector.
Due 11 May 2017
Resolved 10 May 2017
Resolution: Verified proper operation of damper. //s// [name withheld]