← All vessels
RIO GAS
RIO GAS is a 1986 tank ship. The Coast Guard has recorded 46 inspections since 1986, most recently in February 2010, along with 18 deficiencies and 9 operational controls.
Records from 1986 to 2010. Most recent: inspection, 7 February 2010.
- Built
- 1986
- Last inspected
- 7 February 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8511031 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELRL3
266333
Flag
GERMANY
—
Maury page id
psix-266333
Inspections, by type
…with no type recorded24
Years with a record
19 calendar years (1986–2010)
The 46 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it7808 - Dead Weight, Ton
12393 - Displacement, Ton
7581 - Convention (Subpart B), Gross Ton
2274 - Convention (Subpart B), Net Ton
12393 - Displacement, Ton
7581 - Convention (Subpart B), Gross Ton
2274 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 46
7 February 2010
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3676585
11 December 2009
Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3648850
10 December 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3645270
5 November 2008
COC-GAS Renew · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3357552
5 August 2005
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2448641
1 July 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2410616
14 February 2005
COC-GAS Renew · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2292520
12 July 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2130534
3 March 2004
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2018612
2 March 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2016581
11 February 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2005624
8 September 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1900089
10 December 2002
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1717123
20 November 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1708437
6 August 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1657829
12 April 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1604205
5 April 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1601464
4 April 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1601238
5 September 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 281903
5 September 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1054243
8 April 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 426851
8 April 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1122990
7 December 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 423276
26 July 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 418438
19 May 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 416407
19 March 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 791958
17 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 403740
17 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1108440
12 April 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 390043
12 April 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1081561
27 December 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 857911
5 October 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 461931
11 April 1994
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1167729
2 February 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 364367
18 January 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1164227
9 November 1993
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 362715
9 November 1993
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359669
14 August 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 481945
23 December 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1256177
30 October 1990
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 928416
29 October 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 339962
2 November 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 319390
30 October 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 492196
30 October 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1020556
29 March 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 307803
29 March 1986
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1304967
Deficiency record · 18
Construction/Loadline › Structures › Door
Issued 14 February 2005
Resolved
Vessel has two hold backs installed in the area of the Engine Control room.
Electrical › Electric Generation Source (emergency) › Generator
Issued 14 February 2005
Resolved
Second means of starting emergency generator not working properly.(solas II-1/44.2) Investigate cause of malfunction and repair to the satisfaction of the certificate issuing authority prior to 01MAR05. Inspectors noticed loose gaskets in generator used in the HANSA quick starting method, which may be cause.
Pollution Prevention/Response
Issued 3 March 2004
Resolved
Vsl has invalid COFR. Must obtain valid COFR priot o conducting cargo operations, shifting or bunkering.
Pollution Prevention/Response
Issued 3 March 2004
Resolved
Vsl did not have a valid COFR. Vsl must submit LOU for 97,500 U.S. dollars prior to departing the port.
Deck/Cargo › Cargo Stowage
Issued 11 February 2004
Resolved
Audible alarms for tanks 1&2 for pressure monitor is inoperable (46CFR154.1335). Repair to the satisfaction of the certificate issuing authority.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 5 April 2002
Resolved
SOFT PATCH LEAKING ON DECK WATER SPRAY PIPING ON PORT SIDE AFT OF THE COMPRESSOR ROOM. LEGACY COMPONENT DESC: Piping
Fire Fighting
Issued 5 September 2000
Resolved
HAVE THE MOTOR ROOM FIXED HALON SYSTEM PROFESSIONALY SERVICED AND PROVIDE SERVICE REPORT TO THIS OFFICE.
Fire Fighting
Issued 5 September 2000
Resolved
HAVE CLASS ATTEST TO THE ADEQUACY OF THE PAINT LOCKER SPRINKLER SYSTEM, IE:NUMBER OF SPRINKLER HEADS, AREA OF COVERAGE, AND LOCATION OF ACTIVATION VALVE, INCLUDING THE SYSTEMS DELIVERY RATE.
Deck/Cargo
Issued 19 May 1998
Resolved
MAKE PERMANENT REPAIRS TO IG GAS LINE BETWEEN SCRUBBER OUTLET AND KNOCKOUT DRUM.
Accommodation/Occupational Safety
Issued 19 May 1998
Resolved
MAKE PERMANENT REPAIRS TO MARINE SANITATION DEVICE OVERBOARD DISCHARGE AT THE OVERBOARD CHECK VALVE.
Electrical
Issued 12 April 1996
Resolved
Provide flag state documentation that determines that the bare lamp lighting in the electric motor room is adequate as explosive proof.
Navigation
Issued 27 December 1994
Resolved
PRIOR TO NEXT U.S. VOYAGE, PROVIDE UPDATED/CORRECTED CHARTS 11324, 11327, 11328, & 11329 AND PUB. COAST PILOT 5, & LIGHT LIST IV.
Deck/Cargo
Issued 27 December 1994
Resolved
PROVIDE DOCUMENTATION OF SATISFACTORY OPERATIONAL TESTS OF ALL CARGO RELIEFVALVES; ie. PIPING AND TANKS.
Construction/Loadline
Issued 11 April 1994
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED PORT BOW AREA.
Construction/Loadline
Issued 9 November 1993
Resolved
PRIOR TOP TRANSFER OF CARGO THE INTERBARRIER SPACES MUST BE INERTED OR CONTAIN DRY AIR. I.A.W. 46CFR 154.902(d)
Deck/Cargo
Issued 9 November 1993
Resolved
PRIOR TO NEXT U.S. PORT, PROVE PROPER OPERATION OF BOW THRUSTER UNIT TO THELOCAL [name withheld].
Deck/Cargo
Issued 29 March 1986
Resolved
PROVIDE COMDT (G-MTH-1) WITH TECHNICAL DATA SHOWING THAT THE DRAGER CATALYTIC GAS DETECTION SYSTEM IS CAPABLE OF MEASURING FLAMMABLE VAPOR CONCENTRATIONS IN INERTED SPACES.
Fire Fighting
Issued 29 March 1986
Resolved
PROVIDE A FIREFIGHTING SYSTEM FOR THE FORECASTLE PAINT LOCKER WHICH WILL COMPLY WITH 46 CFR 34.05-5.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.