Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
6092 - Regulatory (Subpart C or D), Net Ton
2078 - Convention (Subpart B), Net Ton
6092 - Regulatory (Subpart C or D), Gross Ton
6927 - Convention (Subpart B), Gross Ton
Maury page id
psix-26646
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 3 January 2017Resolved
Conduct annual service for two (02) fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 February 2017
Resolved 3 January 2017
Resolution: Replaced two (02) extinguishers with servicable units.
Construction/Loadline › Penetrations › Weld
Issued 3 February 2014Resolved
Repair cracked welds on centerline of aft perpendicular in the center aft rake.
Due 18 March 2014
Resolved 12 February 2014
Construction/Loadline › Penetrations › Weld
Issued 3 February 2014Resolved
Repair cracked welds in stiffener at aft perpendicular in port aft rake.
Due 18 March 2014
Resolved 12 February 2014
Construction/Loadline › Hull › Girder
Issued 3 February 2014Resolved
Crop and renew Fr 7A at side shell. Repair Fracture at Fr 6. Repair side shell between Fr 5A 5C. Further discussion to determine exact dimensions.
Due 18 March 2014
Resolved 12 March 2014
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 January 2012Resolved
Effect satisfactory repair of the sideshell plating and internal structural members listed in the ABS Surveyor's report (see attached: repair survey_2012) in way of stbd void 05 from frame 32-34.
Action required: 705 - Other - as specified
Resolved 21 January 2012
Resolution: USCG Inspector visited vessel with [name withheld], ABS and witnessed final repair vacuum box test of sideshell 4''''x6'''' insert from frame 32 and 33 and verified weld up of all internal structural members. All sat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 April 2010Resolved
During SIP casework, it was discovered that the barge had not had an annual inspection in 2009.
Action required: 705 - Other - as specified
Due 11 May 2010
Resolved 11 May 2010
Construction/Loadline › Hull › Hull Plating
Issued 26 February 2009Resolved
Damage on port side between frames 6 and 8 as noted in narrative.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 March 2009
Resolved 5 March 2009
Resolution: Cropped and renewed areas damaged as noted in narrative to the satisfaction of the attending CG inspector.
Fire Fighting
Issued 17 August 2001Resolved
Move fire extinguisher to a more accessable location. 46CFR95.50-10
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Electrical
Issued 17 August 2001Resolved
Prove proper operation of generators overspeed trip device. 46CFR111.12-1 (a)
Condition: Unknown
Due 17 August 2001
Resolved 17 August 2001
Engineering
Issued 17 August 2001Resolved
Provide machinery guard on generator belt. 46CFR58.01-20
Condition: Unknown
Due 17 August 2001
Resolved 17 August 2001