Records from 1986 to 1997. Most recent: operational control imposed, 23 December 1997.
Inspection history · 82
18 December 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 117718
17 November 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 410156
20 October 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 384451
20 October 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 871067
4 October 1995
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 383388
4 October 1995
Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1377543
24 August 1995
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 107777
18 July 1995
MARPOL Annex I Examination · Deficiency Check · Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1453160
12 June 1995
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 380785
12 June 1995
MARPOL Annex I Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 875643
6 May 1995
Quarterly Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1360100
14 January 1995
Quarterly Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1153147
6 January 1995
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 668987
14 October 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 372276
14 October 1994
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 867557
29 September 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 710822
28 September 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 370742
28 September 1994
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 868614
30 August 1994
MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1423991
27 July 1994
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 167878
20 May 1994
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1170572
18 May 1994
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1170547
6 May 1994
Control Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385234
18 January 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 850808
6 January 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 652482
12 December 1993
Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 849673
4 November 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 687372
23 October 1993
Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 840885
23 October 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1135385
30 September 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 177030
28 September 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 361229
14 September 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 360888
3 August 1993
Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1359623
25 May 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 505629
10 May 1993
Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1359559
8 March 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1143570
5 March 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 668985
14 February 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1150057
11 February 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 142127
31 January 1993
Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1144999
13 December 1992
Certificate of Compliance · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1138769
25 October 1992
Control Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1257790
9 October 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 353672
9 October 1992
Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1261805
30 July 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 687371
30 July 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 687373
20 May 1992
Certificate of Compliance · Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 949750
22 March 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 949248
26 January 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1011772
23 October 1991
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1250993
23 July 1991
Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 941389
5 May 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 346284
31 March 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 343158
31 March 1991
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1211664
2 November 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 907969
21 September 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 490743
11 July 1990
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 924028
13 April 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1217909
19 January 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 334857
19 January 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 925612
19 January 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1237685
27 September 1989
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 332780
28 August 1989
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1226070
22 August 1989
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1344319
15 May 1989
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1351817
14 February 1989
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1039455
10 November 1988
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 892017
28 October 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 437656
15 July 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1210185
17 June 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 323999
6 March 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1030920
25 January 1988
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1321868
20 November 1987
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1312390
13 November 1987
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1026254
25 September 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1317163
12 August 1987
Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1337966
10 May 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 316028
10 May 1987
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1023967
27 August 1986
Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1299073
16 May 1986
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 308877
11 May 1986
Control Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1303306
10 May 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 308729
Unknown
Issued 4 October 1995
Resolved
REPAIR BROKEN BRACKET SUPPORTING HOT WATER HEATING TANK. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
REPLACE WASTED LAGGING ON STEAM LINES OUTBOARD OF STARBOARD BOILER. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
PROVIDE METAL GUARD COVER ON OVERHEAD LIGHT FOR DIESEL GENERATOR FUEL TANK_x001C_ON 2ND DECK GENERATOR ROOM. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
REPLACE WASTED SCREENS ON VENTILATION PANEL DUCT OVER DIESEL OIL TANK IN _x001C_ THE GENERATOR ROOM. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
REPLACE WASTED 8 INCH SEWAGE LINE OVERHEAD ON OUTBOARD SIDE BOILER #1. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
REPAIR LEAKS TOP COVER OF HOT WATER HEATING TANK. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Lifesaving
Issued 4 October 1995
Resolved
PROVIDE EMEGENCY LIGHT FOR HATCH TO "C" DECK FROM WATERTIGHT DOOR #43 AT _x001C_ ENGINE SPACES. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
RENEW WASTED FIRE MAIN LINE FROM EMERGENCY FIRE PUMP. WASTED LINE IS FROM _x001C_"Y" TO SPRINKLER VALVE (APPROXIMATELY 3 FEET). _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
CLEAN TENDERS #2 & #4 BILGES FREE OF OIL RESIDUE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
PROVIDE SAFETY GLASS COVERS FOR OVERHEAD LIGHTS IN PAINT & BOS'N STOREROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
RENEW WASTED COVER ON #1 EVAPORATOR PUMP. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
REMOVE MISCELLANEOUS FILTERS BLOCKING CO2 FIRE STATION E-22. PROPERLY STOW FILTERS. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Fire Fighting
Issued 4 October 1995
Resolved
PROVIDE SATISFACTORY MOUNTING FOR PORTABLE FIRE EXTINGUISHERS E-13, E-22, E-27, E-24, E-16, E-21 & E-36. RECHARGE EMPTY PORTABLE EXTINGUISHERS & PROPERLY SEAL CYLINDERS AFTER CHARGING. _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Fire Fighting
Issued 4 October 1995
Resolved
PROPERLY CONNECT & INSTALL CO2 CYLINDER E-22. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Engineering
Issued 4 October 1995
Resolved
REPAIR EXCESSIVE LEAK ON BOILER FEED PUMP. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
RENEW WASTED I-BEAM OVERHEAD IN EVAPORATOR ROOM. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
RENEW WASTED VENTILATION DUCT OVERHEAD IN EVAPORATOR ROOM. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
REPAIR SOFT PATCH LEAK ON FRSH WATER LINE _x001C_ IN EVAPORATOR ROOM. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
RENEW LEAKING SOFT PATCH ON SALT WATER PIPING OVERHEAD IN EVAPORATOR ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
PROPERLY SECURE CHLORINE DRUMS IN EVAPORATOR ROOM. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Unknown
Issued 4 October 1995
Resolved
REPLACE ALL BROKEN VALVE HANDLES IN EVAPORATOR ROOM. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Lifesaving
Issued 18 July 1995
Resolved
CHECK CREW LIFE JACKETS AND REPLACE THE WATER ACTIVATED BATTERIES ON THE LIGHTS AS REQUIRED. MANY JACKETS WORN BY CREW TO ABANDON SHIP MUSTER HAD BATTERIES WHICH WERE SWOLLEN, INDICATING EXPOSURE TO MOISTURE. BATTERIES INTHIS CONDITION MUST BE REPLACED REGARDLESS OF EXPIRATION DATES.
Condition: Unknown
Due 1 August 1995
Resolved 6 September 1995
Electrical
Issued 18 July 1995
Resolved
REPLACE OR FULLY DEGREASE/CLEAN NON CONDUCTING MATTING AROUND MAIN ELECTRICAL BOARD. MATS IN THEIR PRESENT OILED CONDITIONS, MAY NOT PROVIDE SAFETY FROM ELECTRICAL SHOCK HAZARDS.
Condition: Unknown
Due 1 August 1995
Resolved 6 September 1995
Fire Fighting
Issued 18 July 1995
Resolved
PRESSURE TEST FIXED FOAM SYSTEM HOSES IN ENGINE ROOM, SERVICE OR REPLACE ASMAY BE REQUIRED.
Condition: Unknown
Due 1 August 1995
Resolved 6 September 1995
Fire Fighting
Issued 18 July 1995
Resolved
PROVIDE/POST ONBOARD THE CLASS APPROVED CORRECTED/UPDATED COPIES OF FIRE CONTROL PLANS.
Condition: Unknown
Due 13 October 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 18 July 1995
Resolved
MAKE PROPER ENTRIES IN OIL RECORD BOOK TO REFLECT SHIP'S POSITION AT START AND END OF TRANSFERS BETWEEN BILGES/SLUDGE TANKS/OVERBOARD DISCHARGES. MAKEENTRIES FOR TRANSFER FROM BILGES TO SLUDGE/SLOP TANKS.
Condition: Unknown
Due 1 August 1995
Resolved 6 September 1995
Documentation
Issued 12 June 1995
Resolved
PROVIDE COPY OF APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN IN ACCORDANCE WITH REG. 26, MARPOL 73/78.
Condition: Unknown
Due 4 July 1995
Resolved 20 July 1995
Documentation
Issued 12 June 1995
Resolved
_x001C_ AMEND IOPP CERTIFICATE TO REFLECT THE CORRECT MAXIMUM THROUGHPUT OF THE OILY WATER SEPARATING SYSTEMS (ITEM 2.5 OF THE IOPP CERTIFICATE).
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Documentation
Issued 12 June 1995
Resolved
_x001C_ PROVIDE NEW IOPP CERTIFICATE TO REFLECT THE STANDARD FORMAT REQUIRED BY MARPOL 73/78, APPENDIX II (1991 REVISION).
Condition: Unknown
Due 2 November 1995
Resolved 2 November 1995
Fire Fighting
Issued 14 October 1994
Resolved
Provide updated FIRE CONTROL PLANS to reflect 1992 Fire Safety Amendment changes.
Condition: Unknown
Due 8 April 1995
Resolved 8 April 1995
Fire Fighting
Issued 14 October 1994
Resolved
Provide portaqble foam applicator as required by SOLAS II2 Reg.41-2,1.4
Condition: Unknown
Due 8 April 1995
Resolved 8 April 1995
Documentation
Issued 14 October 1994
Resolved
Provide valid lifeboatmens certificates for Indonesians whosecertificates have expired according to existing certificates.
Condition: Unknown
Due 8 April 1995
Resolved 8 April 1995
Lifesaving
Issued 14 October 1994
Resolved
Repair #1 rescue boat engine. In the interim #3 lifeboat to be outfitted and used as rescue boat.
Condition: Unknown
Due 21 October 1994
Resolved 2 December 1994
Engineering
Issued 14 October 1994
Resolved
Repair forward oily water separatorprior to returnto U.S. waters.
Condition: Unknown
Due 14 October 1994
Resolved 2 December 1994
Navigation
Issued 28 September 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Lifesaving
Issued 30 August 1994
Resolved
ALL BEAUFORT INFLATABLE LIFERAFTS (SERIAL NO. H 251827, 251814, 251820, 1319, AND 1329) MUST BE SERVICED AT A FACILITY APPROVED BY THE MANUFACTUREROR REPLACED IN KIND BY SOLAS APPROVED, 25 PERSON LIFERAFTS.
Condition: Unknown
Due 8 November 1994
Resolved 8 November 1994
Lifesaving
Issued 18 May 1994
Resolved
PRIOR TO CARRYING PASSENGERS ON THE #6 TENDER, REPAIR THE EXHAUST LEAK IN THE AFT SECTION.
Condition: Unknown
Due 18 May 1994
Resolved 18 May 1994
Documentation
Issued 12 December 1993
Resolved
Provide updated Code of Federal Regulations.
Condition: Unknown
Due 12 December 1993
Resolved 12 December 1993
Fire Fighting
Issued 3 August 1993
Resolved
Adjust all FSD's to close with an opposing list of 3.5 degrees or provide written approval from the vessel's Classification Society explaining why approved.
Condition: Unknown
Due 3 August 1993
Resolved 3 August 1993
Lifesaving
Issued 3 August 1993
Resolved
Place retro-reflective tape on all the vessel's lifejackets so that both sides of the lifejackets have retro-reflective tape in accordance with SOLAS Resolution A.658(16). The lifejackets are capable of being worn inside-out meeting the requirements of SOLAS 74/78 Chap. III Reg. 32.
Condition: Unknown
Due 3 August 1993
Resolved 3 August 1993
Documentation
Issued 3 August 1993
Resolved
Correct International Loadline Certificate and hull markings to reflect required C1 and Freshwater markings
Condition: Unknown
Due 3 November 1993
Resolved 1 September 1993
Electrical
Issued 3 August 1993
Resolved
Inspect all electrical breaker panels and install guards over open electrical fittings.
Condition: Unknown
Due 31 August 1993
Resolved 1 September 1993
Lifesaving
Issued 3 August 1993
Resolved
Repair and make operational embarkation deck light aids for lifeboats #7 and 11.
Condition: Unknown
Due 17 August 1993
Resolved 23 August 1993
Lifesaving
Issued 3 August 1993
Resolved
Place retro-reflective tape on all tender lifejackets which are reversible in accordance with SOLAS Resolution A.658(16) (Retro tape placed on both sides of jackets). In the opinion of the attending inspector, all the lifejackets on board the tenders were reversible.
Condition: Unknown
Due 31 August 1993
Resolved 1 September 1993
Construction/Loadline
Issued 3 August 1993
Resolved
Inspect all mechanical alarms on watertight doors and repair to ensure these sound during manual closure of watertight doors.
Condition: Unknown
Due 17 August 1993
Resolved 23 August 1993
Documentation
Issued 10 May 1993
Resolved
REVISE AND SUBMIT TO USCG MSO PUGET SOUND, THE FLAG STATE APPROVED FIRE CONTROL PLAN, ESCAPE PLAN, AND VENTILATION PLAN. REVISIONS SHOULD SHOW VESSEL ARRANGEMENTS AND SYSTEMS AS EXISTING ON BOARD._x001C_ _x001C_
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Lifesaving
Issued 10 May 1993
Resolved
REVISE VESSEL EVACUATION PLANS AND PROCEDURES TO ENSURE THE 4-DOG WATER- TIGHT DOORS ON VERANDAH DECK (AT FORWARD HATCH) ARE OPENED IN PATH OF EGRESS DURING ABANDON SHIP. SUBMIT REVISED PROCEDURES TO USCG MSO PUGET SOUND._x001C_
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Fire Fighting
Issued 8 March 1993
Resolved
Demonstrate adequate insulation on stairs vent ducts A & B deck, P & S, FWDstaris (outside MVZ's).
Condition: Unknown
Due 8 March 1993
Resolved 8 March 1993
Fire Fighting
Issued 31 January 1993
Resolved
Demonstrate all MVZ fire dampers are in compliance w/solas 48 II/29 and 74 II/68(c) in that they are manually operable from both sides, marked, and auto where required by 68(c).
Condition: Unknown
Due 31 January 1993
Resolved 31 January 1993
Electrical
Issued 13 December 1992
Resolved
Install additional emergency lighting in: (1) aft port pass-way 'C' deck, (2) pass-way near firedoor BD 123 'B' deck, (3) 5 additional lights in main galley.
Condition: Unknown
Due 13 December 1992
Resolved 13 December 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
Remove glass doors obstructing exit from stairs to weather deck, P & S sun deck.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
Remove contents of staterooms 29S and 30S.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
Reomve contents of photolab.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
Repack emergency firepump.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
Install a fire damper on duct through MVZ at frame 39, A deck STBD (6" x 24")
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Construction/Loadline
Issued 25 October 1992
Resolved
Repair penetrations at frame 39 main deck MVZ.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
Remove swinging doors adjacent to fire doors between auditiorium and stairs.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
Reomve all combustibles from duty free shop.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
Replace dead emergency fire pump starting battery.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Lifesaving
Issued 25 October 1992
Resolved
Repair #2 lifeboat rudder where wasted at upper end.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Electrical
Issued 25 October 1992
Resolved
Repair emergency lights at following locations: Cabins 208,207, fire door BD104 (both sides), at firedoor BD4, and STBD aft Lido
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Electrical
Issued 25 October 1992
Resolved
Demonstrate automatic change over of emergency light battery system upon_x001C_ loss of power.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Construction/Loadline
Issued 25 October 1992
Resolved
Adjust WT door 46 operating lever so it operates in full open position.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
Secure fire pump start battery to foundation.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
Repair castodor cover panels that prevent door reopening.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
Repair 2" gap at elevator door, A deck, STBD, aft of dining room.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Documentation
Issued 25 October 1992
Resolved
Provide evidence at 1st U.S. Port of Call; L/R servicing.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Documentation
Issued 25 October 1992
Resolved
Provide evidence at 1st U.S. Port of Call; portable fire ext. servicing
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Engineering
Issued 25 October 1992
Resolved
Provide gaging report of P & S boiler O.F. deep tanks I.W.O. voids and makenecessary repairs as required by Lloyds interim class cert no. lan 200110 dated 17OCT92.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
Demonstrate aft main dining room doors can be operated by one person.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
Paint all fire doors white in areas of 38A throught 38I as a temporary measure until the new fixtures are installed.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Documentation
Issued 25 October 1992
Resolved
Provide evidence at 1st US Port of Call; fixed CO2 servicing.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992
Resolved
Repair emergency light at cabin 15A.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
Repair following fire screen doors: 29, 46A, 49A, 29A,52A, 60,61, BD6, 12, 100, 112, 115, port aft regency lounge, 83, 93, 97, 41, 118, 122, 124, 121,137, 138, 16, at stateroom 71, 78, 70, 100, BD2, 80, 85.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
Identify stop switches for ventilation shutdowns in wheelhouse.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Construction/Loadline
Issued 25 October 1992
Resolved
Secure side ports with all dogs.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Lifesaving
Issued 25 October 1992
Resolved
Post muster lists bridge, crew and officer lounges, engineroom.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
Clean paint from sprinkler heads (2) at fire door 115 in stairs.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Lifesaving
Issued 25 October 1992
Resolved
Install reflective tape per solas for all lifejackets, both sides.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
B deck FWD MVZ STBD has a vent duct without a fire damper.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
There is inadequate escape markings throughout the vessel.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
There is a hole in the stairtower adjacent to a locker at fire door 115.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
Castodors to be redemonstrated, including trim clips.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Electrical
Issued 25 October 1992
Resolved
Emergency light lens missing at room 2B and fire door BD104.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992
Resolved
Install additional emergency lights in Auditorium.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Engineering
Issued 25 October 1992
Resolved
Repair main shaft packing. Leaking at both shafts equivelent to 1 1/2" firehose.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Navigation
Issued 25 October 1992
Resolved
Renew wasted drain lines P & S in steering gear room.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
There are many fire boundary violations, including pipe and cable penetrations in all main vertical zones and A class boundaries.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Documentation
Issued 25 October 1992
Resolved
Submit the flag state approved fire control plan, escape plan, and ventilaton plans to Commandant G-MSC for review.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Construction/Loadline
Issued 25 October 1992
Resolved
WT doors 12 and 29 must remain connected at all times and be operable from both sides.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
The draft stops are not acceptable. Be prepared to show them after review_x001C_of flag state approved details.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
Submit flag state approved details of installation and material of construction for draft stops.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Electrical
Issued 25 October 1992
Resolved
Install additional emergency lights P & S bridge deck aft of radio room.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992
Resolved
Install additional emergency lights at P & S enclosures outboard of casino.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992
Resolved
Install additional emergency lights at casino
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992
Resolved
Install additional emergency lights in corridors at the following cabins: 180, 181,185,259,284,254,240, between sauna and stairs, at firedoor BD108.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992
Resolved
Install additional emergency lights at Regency Lounge.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992
Resolved
Install additional emergency lights at P & S outboard of Lido Lounge
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992
Resolved
Install additional emergency lights at Lido Lounge.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
Many sprinkler heads are recessed too far into ceilings. Adjust to have_x001C_ at least 1-1/2" of heads below ceilings.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992
Resolved
Install emergency lights at passageway aft of officer lounge.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992
Resolved
Renew all emergency light lens yellowed from heat & age.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
Remove swinging wood doors at firedoor BD130.
Condition: Unknown
Due 28 October 1992
Resolved 28 October 1992
Navigation
Issued 9 October 1992
Resolved
U.S. CHART 18773, 31ST EDITION (18JUN88) NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Navigation
Issued 9 October 1992
Resolved
LORAN C RECEIVER DID NOT HAVE LABEL REQUIRED BY 33CFR164.41.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Navigation
Issued 9 October 1992
Resolved
PRE-ARRIVAL TEST REQUIRED BY 33CFR164.25 NOT LOGGED.
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Fire Fighting
Issued 9 October 1992
Resolved
FIRE SCREEN DOORS DID NOT OPERATE/DID NOT PROPERLY CLOSE.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Fire Fighting
Issued 9 October 1992
Resolved
ZONE 9 WAS PLUGGED UP WITH NO FLOW OF WATER. ALSO, ONE SECTION OF PIPING INZONE WAS HOLED.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Construction/Loadline
Issued 9 October 1992
Resolved
WTD #29 DID NOT OPERATE. VESSEL LEAVES THIS DOOR CLOSED FULL TIME- ALSO NOTED DOOR LEAKING HYDRAULIC FLUID.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Lifesaving
Issued 9 October 1992
Resolved
ALL LIFERAFTS IMPROPERLY INSTALLED. MISSING WEAKLINKS AND HYDRO RELEASES WERE OUTDATED. SOME RAFTS WERE TIED TO THE VESSEL AND WERE NOT FLOAT FREE.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Documentation
Issued 9 October 1992
Resolved
FIRE CONTROL PLANS SERIOUSLY OUTDATED. MAJOR CHANGES IN VESSEL NOT REFLECTED ON PLAN.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Fire Fighting
Issued 9 October 1992
Resolved
PROVE PROPER OPERATION OF FIRE DETECTION SYSTEM.
Condition: Unknown
Due 13 October 1992
Resolved 13 October 1992
Accommodation/Occupational Safety
Issued 9 October 1992
Resolved
REMOVE ALL LOCKS FROM GLASS DOORS AND ESCAPE ROUTES IN SRAIR TOWERS.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Electrical
Issued 9 October 1992
Resolved
BATTERY BANK NOT LEAD LINED.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Fire Fighting
Issued 9 October 1992
Resolved
REPLACE GASKET ON FIRE STATION 18. CURRENT GASKET PROTRUDES OUTWARD AND WILL NOT ALLOW THE HOSE TO CONNECT TO THE HYDRANT.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Lifesaving
Issued 9 October 1992
Resolved
REMOVE ALL COMBUSTIBLES IN UNAUTHORIZED STORE ROOMS WHICH OPEN INTO STAIR TOWERS. ALSO NOTED TWO STATEROOMS 30S AND 29S, ON SUN DECK WHICH OPEN DIRECTLY INTO STAIR TOWER W/O AN A-60 FIRE DOOR. NUMEROUS OTHER STATEROOMSOPEN INTO TOWERS, BUT ARE PROTECTED BY BY AN A-60 DOOR.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Accommodation/Occupational Safety
Issued 9 October 1992
Resolved
REMOVE ALL COMBUSTIBLES FROM FAN AND VENTILATION SPACES.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Electrical
Issued 9 October 1992
Resolved
REMOVE UNAUTHORIZED BATTERY BANK, PORT SIDE, ADJACENT TO BATTERY ROOM. SPACE IS NOT VENTILATED OR SET UP FOR BATTERY INSTALLATION.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Electrical
Issued 9 October 1992
Resolved
ELECTRICAL PANEL FOR FIRE ALARMS NEEDED DEAD COVERS FOR OPEN SLOTS.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Lifesaving
Issued 9 October 1992
Resolved
ENSURE EPIRB IS INSTALLED IN A FLOAT FREE ARRANGEMENT. THE EPIRB WAS BLOCKED BY SEARCHLIGHT INSTALLATION.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Construction/Loadline
Issued 9 October 1992
Resolved
PROPERLY SECURE FWD DOOR, STBD SIDE, ON ELECTRICAL ROOM ON HOUSE TOP.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Navigation
Issued 9 October 1992
Resolved
REPAIR HYDRAULIC LEAK ON MAIN STEERING STATION.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Lifesaving
Issued 9 October 1992
Resolved
REPAIR/REPLACE ALL CREW PFD'S AS NEEDED. NOTED APPROX 25 WERE TORN. SPOT CHECKED PAX STATEROOMS, ALL APPEARED SAT. MASTER STATED HE HAD REPLACEMENTS ON BOARD AND WOULD DISTRIBUTE AS NECESSARY.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Lifesaving
Issued 9 October 1992
Resolved
REMOVE ALL COMBUSTIBLES STOWED IN STAIR TOWERS.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Fire Fighting
Issued 26 January 1992
Resolved
THE PORT AND STARBOARD SIDE FIRE SCREEN DOORS FOR ACCESS TO, OR EGRESS FROMTHE CINEMA ARE MISSING CLOSURES.
Condition: Unknown
Due 26 January 1992
Resolved 26 January 1992
Lifesaving
Issued 26 January 1992
Resolved
PLACE IN THE PAINT LOCKER ALL CANS OF PAINT AND THINNER. ALL CANS MUST BE CLOSED WHEN NOT IN IMMEDIATE USE.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Fire Fighting
Issued 26 January 1992
Resolved
DEMONSTRATE MANUAL OPERATION OF ALL FIRE DAMPERS FROM EACH SIDE OF THE BULKHEAD IN ALL TRUNKS PASSING THROUGH MAIN VERTICAL ZONE BULKHEADS.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Lifesaving
Issued 26 January 1992
Resolved
EXCESS CHILD LIFEJACKETS WITHOUT LIGHTS ARE NOT TO BE STOWED WITH THE REQUIRED LIFEJACKETS (SUNDECK)
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Fire Fighting
Issued 26 January 1992
Resolved
REPAIR AND DEMONSTRATE CLOSING AND LATCHING OF THE FOLLOWING FIRE SCREEN DOORS: BD7, 39, 40, 80, 84, 85, 88, 92, 100, 133, 142. NOTE: SERVERAL OF THESE DOORS' MAGNETIC HOLD-BACKS APPEAR TO HAVE MAGNETIZED THE METAL PLATE ONTHE FIRE SCREEN DOOOR, MAKING THE RELEASE OF THE DOOR UNRELIABLE.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Electrical
Issued 26 January 1992
Resolved
THE MAJORITY OF THE EMERGENCY LIGHTS THROUGHOUT THE VESSEL ARE NOT MARKED.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Lifesaving
Issued 26 January 1992
Resolved
PORT ILLUSTRATED LIFERAFT LAUNCHING INSTRUCTIONS, READABLE UNDER EMERGENCY LIGHTING CONDITIONS, AT EACH LAUNCHING STATION.
Condition: Unknown
Due 26 January 1992
Resolved 26 January 1992
Fire Fighting
Issued 26 January 1992
Resolved
INSTALL A PROPER A-60 DECK PENETRATION INSIDE HOSE STATION 119 (BETWEEN ENGINE ROOM AND GYMNASIUM).
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Fire Fighting
Issued 26 January 1992
Resolved
THE FIRE HOSE STATIONS IN THE MAIN DINING ROOM ARE NOT VISIBLE (OBSTRUCTED BY CURTAINS)
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Fire Fighting
Issued 26 January 1992
Resolved
REINSTALL THE FIRE SCREEN DOOR BETWEEN THE OFFICER'S MESS AND GALLEY.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Fire Fighting
Issued 26 January 1992
Resolved
THE FIRE DAMPER IN THE MAIN GALLEY ABOVE FIRE STATION 56 IS MISSING THE HANDLE.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Electrical
Issued 26 January 1992
Resolved
REPAIR THE EMERGENCY LIGHT AT FIRE STATION 114, "C" DECK.
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Lifesaving
Issued 11 July 1990
Resolved
PROVIDE SOLAS CERTIFICATE FOR SHIP'S TENDERS NO. 3,4,5,AND 6 PRIOR TO NEXT QUARTERLY REINSPECTION.
Condition: Unknown
Due 11 July 1990
Resolved 11 July 1990
Navigation
Issued 27 September 1989
Resolved
MANEUVERING FACT SHEET MISSING INFORMATION FOR MANEUVERING IN DIFFERENT LOAD CONDITIONS AND MISSING WARNING STATEMENT. 33 CFR 164.35 (G)
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Navigation
Issued 10 May 1987
Resolved
ADMIRALTY CHARTS 899, 1063, 1081, 1082 AND COAST PILOT VOL. 8 AND LIGHT LIST VOL. G NOT CORRECTED TO DATE. TIDE AND TIDAL CURRENT TABLES NOT ON BOARD.
Condition: Unknown
Due 10 May 1987
Resolved 10 May 1987
Construction/Loadline
Issued 10 May 1987
Resolved
PROPERLY CLOSE AND INSULATE WHERE APPROPRIATE THE OPENINGS IN THE BULKHEAD IN FOLLOWING LOCATIONS: ABOVE FDS #20,26,32,41,49,102,105; ABOVE FSD #18, 23,46A,78; ADJACENT TO AND ABOVE FSD #27A; IN DRAFT STOPS BETWEEN ROOMS 138-140, OUTSIDE RM 207 & 230.
Condition: Unknown
Due 10 May 1987
Resolved 10 May 1987
Fire Fighting
Issued 10 May 1987
Resolved
ADJUST AND DEMONSTRATE PROPER CLOSING OF FOLLOWING FIRE SCREEN DOORS: FD 102, BD 140.
Condition: Unknown
Due 10 May 1987
Resolved 10 May 1987
Fire Fighting
Issued 10 May 1987
Resolved
INSTALL AUTOMATIC CLOSING DEVICE ON DOOR TO MAIN DECK FORWARD STOREROOM.
Condition: Unknown
Due 10 May 1987
Resolved 10 May 1987
Fire Fighting
Issued 10 May 1987
Resolved
ADJUST AND DEMONSTRATE PROPER OPERATION OF THE FIRE DAMPER IN FIRE ROOM #9.
Condition: Unknown
Due 10 May 1987
Resolved 10 May 1987
Accommodation/Occupational Safety
Issued 10 May 1987
Resolved
REMOVE PLYWOOD SHEETS LOCATED IN FAN ROOM #11, VENTS N42A AND N42B.
Condition: Unknown
Due 10 May 1987
Resolved 10 May 1987
Fire Fighting
Issued 11 May 1986
Resolved
UPDATE FIXED CO2/SMOKE DETECTION SYSTEM PLAN TO ACCURATLEY.
Condition: Unknown
Due 11 May 1986
Resolved 11 May 1986
Fire Fighting
Issued 11 May 1986
Resolved
ENSURE MAIN BAR PANTRY (ON VERANDA-DECK) DOORS AND BULKHEADS ARE "A" CLASS.
Condition: Unknown
Due 11 May 1986
Resolved 11 May 1986
Fire Fighting
Issued 11 May 1986
Resolved
SEND FOAM SAMPLE OUT FOR ANALYSIS.
Condition: Unknown
Due 11 May 1986
Resolved 11 May 1986
Fire Fighting
Issued 11 May 1986
Resolved
PROVIDE WATERTIGHT CONTAINERS FOR FIRE CONTROL PLANS AT GANGWAYS AND LABLE CONTAINERS WITH "FIRE CONTROL PLAN".
Condition: Unknown
Due 11 May 1986
Resolved 11 May 1986
Navigation
Issued 10 May 1986
Resolved
33 CFR 164.33(A)(II) USCG LIGHT LIST NOT ON BOARD
Condition: Unknown
Due 11 May 1986
Resolved 10 May 1986