Records from 1986 to 2007. Most recent: inspection, 3 April 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
3 April 2007
Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Deficiency Check · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2900101
12 March 2005
PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2301429
23 February 2005
Ballast Water Examination · ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2297533
20 February 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2295947
24 May 2004
Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2076798
29 May 2002
Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1620398
2 May 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 289636
24 March 2000
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 275847
3 March 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 426024
29 March 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 414454
12 December 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 411230
28 May 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 393278
17 August 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 381466
10 June 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 379426
8 June 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 379211
23 May 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 448771
22 September 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 339407
11 August 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 310712
13 June 1986
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 473858
10 April 1986
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 307876
8 April 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 308028
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 12 March 2005
Resolved
Remove open oil drum from lower engine room where currently 55 gallon drum is used to collect oil drainings from the deck below generators. SOLAS II-2/4. Action 70c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 April 2007
Resolution: SECTOR New Orleans conducted boarding on vessel, drum was removed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, High Pressure (fuel injection)
Issued 12 March 2005
Resolved
Install class approved protective tape on all high pressure fuel lines as required by SOLAS 74 amd II-2/15.9-11. Action 70c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 April 2007
Resolution: SECTOR New Orleans conducted boarding on vessel, class approved protective tape was on all high pressure fuel lines.
Navigation
Issued 24 March 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 May 2001
Resolved 3 May 2001
Lifesaving
Issued 3 March 1999
Resolved
Class to attend vessel and attest to proper operation of port and stbd lifeboat davit deadman brakes.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Navigation
Issued 12 December 1997
Resolved
Steering Gear Room does not have a non-slip surface as required by SOLAS _x001C_ Chapter II-2, Regulation 29.13.2
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Engineering
Issued 28 May 1996
Resolved
Clean engineroom of excess oil especially in way of generators, purifiers, and the main engine. Empty all catch buckets in these same areas of accumulated fuel oil. SOLAS II 2/15 (2)
Condition: Unknown
Due 21 January 1998
Resolved 21 January 1998
Accommodation/Occupational Safety
Issued 28 May 1996
Resolved
Make permanent repairs to sewage overboard drain line near sideshell, STBD aft, lower engine room in way of cement box. SOLAS II 1/26
Condition: Unknown
Due 21 January 1998
Resolved 21 January 1998
Lifesaving
Issued 28 May 1996
Resolved
Remove stored paints from stbd aft locker on main deck to approved paint locker or make current location into approved paint locker._x001C_ SOLAS II 2/18_x001C_
Condition: Unknown
Due 21 January 1998
Resolved 21 January 1998
Deck/Cargo
Issued 8 June 1995
Resolved
Repair cargo hold control valves for holds 1,2,3,4 and 5 for excessive leaks.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Fire Fighting
Issued 8 June 1995
Resolved
Make repairs and prove operation of emergency fire pump.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Deck/Cargo
Issued 8 June 1995
Resolved
Repair cargo hatch ram #2 starboard forward for excessive leakage.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Lifesaving
Issued 8 June 1995
Resolved
Make following repairs to vessels lifeboats: storage locker covers broken, canopy stanchions broken, seat supports severely corroded.
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Fire Fighting
Issued 8 June 1995
Resolved
Make permanent repairs to fire main by #5 cargo hold.(2- Jubilee patches).
Condition: Unknown
Due 24 August 1995
Resolved 24 August 1995
Navigation
Issued 8 April 1986
Resolved
VESSEL MISSING LOCAL CHART 13221, NARRAGANSETT BAY.
Condition: Unknown
Due 8 April 1986
Resolved 8 April 1986
Documentation
Issued 8 April 1986
Resolved
VESSEL MISSING OIL TRANSFER PROCEDURES THAT ARE IAW 33 CFR 155.720(A)
Condition: Unknown
Due 10 April 1986
Resolved 8 April 1986