MAURY USCG vessel records Sign in
← All vessels

SIKUMI

SIKUMI is a 1985 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 1986, most recently in May 2021, along with 34 deficiencies.

Records from 1986 to 2021. Most recent: inspection, 21 May 2021.

Built
1985
Last inspected
21 May 2021
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB3009
266674
Flag
UNITED STATES
369244000 (licence lapsed)
Maury page id
psix-266674

Inspections, by type

…with no type recorded5
Years with a record 14 calendar years (1986–2021)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.3 ft × 23.2 ft × 10.8 ft
Registered tonnagegross 103 / net 83
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHANSEN BOAT CO · MARYSVILLE, WA, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPETERSBURG, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 5 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it103 - Simplified, Gross Ton
83 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB3009MMSI 369244000 · expired · compulsorily equipped · granted 20 February 2003, cancelled 27 April 2013
WCY5102MMSI not assigned · expired · compulsorily equipped · granted 30 June 1998, cancelled 30 August 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 32

21 May 2021 Uninspected Passenger Vessel
Physical examination · USCG Arctic District (dp) · USCG Arctic District (CGD-A) · Activity 7284217
22 July 2017 Uninspected Passenger Vessel
Physical examination · USCG Arctic District (dp) · USCG Arctic District (CGD-A) · Activity 6220861
15 July 2009 Uninspected Passenger Vessel
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3536068
2 February 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1125962
15 August 1995 COI Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1363343
8 March 1995 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 862618
1 December 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 871370
10 November 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 862542
3 November 1994 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1455212
14 October 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1177135
12 October 1994 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1425508
29 October 1993 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 838182
30 September 1993 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1373938
1 October 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1387276
4 August 1992 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1259441
8 July 1992 Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 963045
10 June 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1423706
25 November 1991 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 937032
8 August 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1245510
5 July 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1243960
5 July 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1245022
1 February 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 918684
11 December 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1241207
20 August 1990 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 924981
18 June 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1240462
11 May 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1229489
19 July 1989 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 897153
19 June 1989 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1198101
24 February 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1199631
15 June 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1201498
9 July 1987 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1019669
24 July 1986 Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1321328

Deficiency record · 34

Engineering
Issued 15 August 1995 Resolved
STENCIL EMERGENCY FUEL SHUT-OFF VALVES.
Condition: Unknown
Due 30 August 1995
Resolved 12 September 1995
Lifesaving
Issued 15 August 1995 Resolved
REPAIR ONE ADULT PERSONAL FLOATATION DEVICE. VESSEL'S CAPACITY LIMITED TO 148 PASSENGERS (ON RESTRICTED ROUTE) UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 30 August 1995
Resolved 12 September 1995
Electrical
Issued 15 August 1995 Resolved
PROVIDE GUARD FOR ENGINE ROOM LIGHT.
Condition: Unknown
Due 19 September 1995
Resolved 25 September 1995
Electrical
Issued 10 November 1994 Resolved
ENCLOSE WIRE LEADS TO VACUUM PUMP.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994
Construction/Loadline
Issued 3 November 1994 Resolved
CLEAN OIL FROM THE BILGES OF THE ENGINE ROOM. THIS ITEM IS TO BE COMPLETEDPRIOR TO CARRIAGE OF PASSENGERS BUT NOT LATER THAN COMPLIANCE DATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 December 1994
Resolved 10 November 1994
Construction/Loadline
Issued 3 November 1994 Resolved
PROVIDE STRAINER FOR FORE PEAK BILGE SUCTION. THIS ITEM IS TO BE COMPLETEDPRIOR TO CARRIAGE OF PASSENGERS BUT NOT LATER THAN COMPLIANCE DATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 December 1994
Resolved 10 November 1994
Construction/Loadline
Issued 3 November 1994 Resolved
PROVIDE VALVES FOR ALL PIPING PENETRATIONS IN COLLISION BULKHEAD. THIS ITEM TO BE COMPLETED PRIOR TO CARRIAGE OF PASSENGERS BUT NOT LATER THAN COMPLIANCE DATE._x001C_ _x001C_
Condition: Unknown
Due 3 December 1994
Resolved 10 November 1994
Electrical
Issued 3 November 1994 Resolved
PROVIDE ONE LINE DIAGRAM FOR ALL NEW ELECTRICAL CABLE RUNS. THIS ITEM TO BE COMPLETED PRIOR TO RUNNING NEW CABLE BUT NOT LATER THAN COMPLIANCE DATE._x001C_ _x001C_
Condition: Unknown
Due 3 December 1994
Resolved 10 November 1994
Electrical
Issued 3 November 1994 Resolved
REMOVE ALL EXTENSION CORDS AND TEMPORARY HOUSEHOLD LIGHTING FIXTURES. THISITEM TO BE COMPLETED PRIOR TO CARRIAGE OF PASSENGERS BUT NOT LATER THAN COMPLIANCE DATE._x001C_ _x001C_
Condition: Unknown
Due 3 December 1994
Resolved 10 November 1994
Electrical
Issued 3 November 1994 Resolved
HARD WIRE ALL PERMANENT ELECTRICAL FIXTURES. THIS ITEM TO BE COMPLETED PRIOR TO CARRIAGE OF PASSENGERS BUT NOT LATER THAN COMPLIANCE DATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 December 1994
Resolved 10 November 1994
Engineering
Issued 12 October 1994 Resolved
LABEL ALL REMOTE FUEL SHUTOFF VALVES.
Condition: Unknown
Due 15 October 1994
Resolved 14 October 1994
Fire Fighting
Issued 12 October 1994 Resolved
LABEL ALL FIRE STATIONS.
Condition: Unknown
Due 15 October 1994
Resolved 14 October 1994
Fire Fighting
Issued 12 October 1994 Resolved
PROVIDE PORTABLE FIRE HAND PUMP
Condition: Unknown
Due 15 October 1994
Resolved 14 October 1994
Accommodation/Occupational Safety
Issued 12 October 1994 Resolved
WELD FRACTURES ON PASSENGER ACCOMODATION LADDER. NO PASSENGERS SHALL BE CARRIED UNTIL THIS IS COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINEINSPECTOR.
Condition: Unknown
Due 15 October 1994
Resolved 14 October 1994
Electrical
Issued 12 October 1994 Resolved
INSTALL BLANK IN #5 BREAKER SLOT IN MAIN DECK DISTRIBUTION PANEL.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Lifesaving
Issued 12 October 1994 Resolved
POST EMERGENCY CHECKOFF LIST PER 46 CFR 185-25-1
Condition: Unknown
Due 11 November 1994
Resolved 14 October 1994
Fire Fighting
Issued 12 October 1994 Resolved
PERMANENTLY INSTALL FIRE HOSES AT FIRE STATIONS.
Condition: Unknown
Due 15 October 1994
Resolved 14 October 1994
Lifesaving
Issued 12 October 1994 Resolved
REMOVE GEAR IN WAY OF EMERGENCY ESCAPE IN MACHINERY SPACE.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Electrical
Issued 12 October 1994 Resolved
LABEL ALL EMERGENCY LIGHTING.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Electrical
Issued 12 October 1994 Resolved
REPAIR EMERGENCY LIGHT AT FWD END OF MAIN DECK.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Electrical
Issued 12 October 1994 Resolved
INSTALL GROMMET ON STBD MOST CABLE UNDER MAIN SWITCHBOARD.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Construction/Loadline
Issued 12 October 1994 Resolved
MAKE SUB-DIVISION BULKHEADS WATERTIGHT.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Lifesaving
Issued 12 October 1994 Resolved
DOUBLE STITCH TOP STITCHING ON 14 ADULT AND 1 CHILD PFD.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Electrical
Issued 12 October 1994 Resolved
INSTALL MARINE APPROVED CABLE FOR VACUUM PUMPS.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Electrical
Issued 30 September 1993 Resolved
REPLACE ALL NON COAST GUARD APPROVED WIRING AND NON ATTENDED PLUG-IN TYPE CONNECTORS WITH COAST GUARD APPROVED WIRING AND APPROVED JUNCTIONS. 46 CFR 183.05-45(a): WIRING SIZES FOR LIGHTING AND POWER SHALL BE IN ACCORDANCE WITH TABLE 183.05-45(a).
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Engineering
Issued 30 September 1993 Resolved
REPLACE PLASTIC TUBE GAUGES ON FUEL TANKS WITH FIRE RESISTANT GLASS GAUGES.46 CFR 182.20-25(5): WHERE LIQUID LEVEL INDICATING GAGES ARE INSTALLED, THEY SHALL BE OF HEAT RESISTANT MATERIALS, ADEQUATELY PROTECTED FROM MECHANICAL DAMAGE.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Electrical
Issued 30 September 1993 Resolved
PROVIDE DIELECTRIC MAT FOR ENGINE ROOM SWITCH BOARD. 46 CFR 183.10-15(b): SWITCHBOARDS SHALL BE FITTED WITH DRIPHOODS AND NON-CONDUCTING HAND RAILS. NON-CONDUCTING MATS OR GRATING SHALL BE PROVIDED ON DECK IN FRONT AND REAR OF SWITCHBOARDS.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Engineering
Issued 30 September 1993 Resolved
REPLACE PORT GENERATOR FUEL LINES WITH COAST GUARD APPROVED FUEL LINES WITHFACTORY CONNECTORS. 46 CFR 182.20-40(a)(2): FLEXIBLE HOSE MAY BE USED PROVIDED IT IS FITTED WITH SUITABLE CONNECTION FITTINGS AND HAS RESISTANCE TO SALTWATER, PETROLEUM OILS AND VIBRATION. MUST MEET ASTM D1692
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Documentation
Issued 10 June 1992 Resolved
PROVIDE COAST GUARD APPROVED PERMANENT STABILITY LETTER TO THE SATISFACTIONOF THE COGNIZANT OCMI.
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Unknown
Issued 19 June 1989 Resolved
PROVE PROPER OPERATION OF AIR RECIEVER RELIEF VALVE.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Lifesaving
Issued 19 June 1989 Resolved
REPLACE ALL WATERLIGHT BATTERIES.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Fire Fighting
Issued 9 July 1987 Resolved
PROVIDE ADEQUATE FIRE HOSE AND NOZZLE FOR FORWARD HYDRANT IN ACCORDANCE WITH 46 CFR 181.15-5.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Navigation
Issued 9 July 1987 Resolved
PROVIDE 1987 TIDE CURRENT TABLES AND LIGHT LIST FOR PACIFIC NORTHWEST.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Unknown
Issued 9 July 1987 Resolved
PROVIDE EMERGENCY INSTRUCTIONS AND POST ON BOARD IN WHEELHOUSE, IN ACCORDANCE WITH 46 CFR 185.25-1.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987

Ownership record