MAURY USCG vessel records
← All vessels

BRUGGE VENTURE

BRUGGE VENTURE is a 1997 tank ship. The Coast Guard has recorded 3 inspections in 2016, along with 2 deficiencies.

Records in 2016. Most recent: inspection, 16 April 2016.

Built
1997
Last inspected
16 April 2016
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9132789
Flag
HONG KONG
Maury page id
psix-26676

Inspections, by type

Years with a record 1 calendar year (2016)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it6945 - Convention (Subpart B), Net Ton
22352 - Convention (Subpart B), Gross Ton
26777 - Dead Weight, Metric Ton
37661 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

16 April 2016 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5862069
15 April 2016 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 5876489
12 April 2016 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5852916

Deficiency record · 2

Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 12 April 2016 Resolved
While testing the vessel's deck water spray system, the water spray system did not properly cover the number one cargo tank dome, cargo control room/motor room, starboard cargo manifold or either cargo cargo deck tank.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2016
Resolved 16 April 2016
Resolution: Recitfied to the satifaction of attending CG inspector.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 12 April 2016 Resolved
While testing the vessel's emergency shutdown valves, the emergency shutdown valve on the number one liquid line took more than 30 seconds.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 15 April 2016
Resolution: Engineer sucessfully adjusted emergency shutdown valve to time limit requirements of 30 seconds or less.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.