Records in 1997. Most recent: inspection, 25 March 1997.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, DEMONSTRATE PROPER OPERATION OF EMERGENCY POWER SYSTEM UNDER LOAD TO CG BOARDING OFFICER. SOLAS 60, II/26
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Fire Fighting
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE COMPLETE INTERNATIONAL SHORE CONNECTION. SOLAS60, II/56
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Fire Fighting
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, CONDUCT TEST OF FIXED FIRE/SMOKE DETECTION SYSTEM IN PRESENCE OF CG BOARDING OFFICER. SOLAS 60, II/61
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Documentation
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PRODUCE OFFICERS LICENCES TO CG BOARDING OFFICER. STCW, 1978.
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Lifesaving
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PRESENT FOR INSPECTION ALL EXPOSURE SUITS AND THERMAL PROTECTIVE AIDS TO CG BOARDING OFFICER. SOLAS 74, III/19
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Unknown
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, COMPLETE INSPECTION OF ALL POLLUTION PREVENTION REQUIREMENTS IN PRESENCE OF CG BOARDING OFFICER. 33 CFR 151, 33 CFR 156.
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Construction/Loadline
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION AS TO CONDITION OF TYPE III WATERTIGHT DOOR ALARMS FOR THE REFIRIGERATION SPACES, LOCATED IN WAY OF CONTROLS IN PORTSIDE PASSAGE, MAIN DECK, AND DEMONSTRATE OPERATION TO CG BOARDING OFFICER. SOLAS 74 AMEN, II-2/21.
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Lifesaving
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, REMOVE EXCESSIVE PAINT/FLAMMABLES FROM SPACE ADJACENT TO AFTER STEERING. PWSA, 33 USC 1223(B).
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Fire Fighting
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE NON-COMBUSTABLE LIFE LINES FOR ALL FIRE FIGHTING OUTFITS ON BOARD. SOLAS 60, II/63
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Fire Fighting
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE APPROPRIATE EQUIPMENT AT SHAFT ALLEY FIRESTATION. SOLAS 74 AMEN, II-2/21
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Fire Fighting
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, MAKE PERMANENT REPAIRS TO EMERGENCY FIREPUMP DISCHARGE PIPING WHERE HOLED/WASTED. SOLAS 74 AMEN, II-2/21
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Fire Fighting
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, MAKE PERMANENT REPAIRS TO FIRESTATION #13 PIPING WHERE HOLED. SOLAS 74 AMEN, II-2/21
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Fire Fighting
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, MAKE PERMANENT REPAIRS TO FIRESTATION #14 PIPING WHERE HOLED. SOLAS 74 AMEN, II-2/21
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Navigation
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, CONDUCT STEERING GEAR TEST- PRIMARY AND EMERGENCY, IN PRESENCE OF CG BOARDING OFFICER. SOLAS 60, II/29.
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Navigation
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION AS TO PRESENT ARRANGEMENT OF UNGUARDED MACHINERY IN THE STEERING GEAR SYSTEM AND THE PERSONNEL HAZARDS INHERANT BY DESIGN. PWSA, 33 USC 1223(B).
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Engineering
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION AS TO SERVICEABILITY OF EMERGENCY FIRE PUMP PRIME MOVER EXHAUST SYSTEM AND CONDITION OF EXHAUST PIPING WHERE LEAKING/WASTED. PWSA, 33 USC 1223(B)
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Lifesaving
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, RE-STOW VSL'S LIFERAFTS IN A FLOAT FREE POSITION, READYFOR DEPLOYMENT. SOLAS 74 AMEN, III/13.
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Fire Fighting
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, RENEW ALL FIRE CONTROL PLANS ON BOARD SO AS EASILY READAND IN LANGUAGE OF CREW AND ENGLISH. SOLAS 74 AMEN, II-2/20
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Fire Fighting
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE ANNUAL SERVICE REPORT FOR FIXED FIRE EXTINGUISHING SYSTEM (CO2). SOLAS 60, II/58
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Fire Fighting
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CO2 SYSTEM INTRUCTIONS AND POST IN LANGUAGE UNDERSTOOD BY CREW. SOLAS 74 AMEN, II-2/20
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Lifesaving
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PRODUCE VSL LIFESAVING/TRAINING MANUALS AND LOGS TO CG INSPECTOR. SOLAS 74 AMEN, III/18
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Lifesaving
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, RENEW ALL CREW MUSTER LISTS ON BOARD TO REFLECT PRESENTCREW. SOLAS 74 AMEN, III/8
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Lifesaving
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE ANNUAL SERVICE REPORTS FOR ALL LIFERAFTS ABOARD. SOLAS 74 AMEN, III/19
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Lifesaving
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CG BOARDING OFFICER WITH ALL APPROPRIATE LIFEBOAT EQUIPMENT AS PRESCRIBED BY SOLAS 74 AMEN, III/41
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Lifesaving
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, DEMONSTRATE PROPER OPERATION OF LIFEBOAT PORTABLE RADIOAPPARATUS. SOLAS 60, III/13
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Construction/Loadline
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, RENEW VSL'S LOADLINE AND DRAFTMARKS AMIDSHIPS IN CONTRASTING COLOAR WITH HULL. ICLL 66
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Construction/Loadline
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION AS TO WATERTIGHT INTEGRITY OFTHE AFTERSTEERING COMPARTMENT. ICLL 66
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Construction/Loadline
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION AS TO CONDITION OF WATERTIGHTDOOR TO AFTERSTEERING AND OTHER SPACES, LOCATED ON MAIN DECK, AFT. ICLL 66
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Construction/Loadline
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION AS TO SERVICEABILITY OF FIBERGLASS PATCH ON VSL SIDESHELL IWO AFTERSTEERING. ICLL 66.
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Construction/Loadline
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION AS TO CONDITION OF THE HULL IN WAY OF FRACTURE LOCATED IN THE PORT SIDE BOW, NEAR BULWARK AND DECK SEAMWELD. ICLL 66.
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Engineering
Issued 14 March 1997
Resolved
PRIOR TO RETURN TO U.S., PROVIDE CLASS ATTESTATION TO SERVICEABILITY OF TEMPORARY REPAIR IN MAIN ENGINE/SS GENERATOR MAIN COLLING LINE IN WAY OF MAIN CIRCULATION PUMP. SOLAS 60, I/11
Condition: Unknown
Due 21 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 14 March 1997
Resolved
PRIOR TO RETURN TO U.S., PROVIDE CLASS ATTESTATION AS TO CONDITION OF LUBE OIL COOLING PIPING ON #1 SS GENERATOR WHERE HOLED AT BEND IN WAY OF COOLER.S OLAS 60, I/11
Condition: Unknown
Due 21 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 14 March 1997
Resolved
PRIOR TO VSL DEPARTURE, CONDUCT ABANDON SHIP DRILL IN PRESENCE OF CG BOARDING OFFICER. SOLAS 74, III/18.
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Electrical
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE APPROPRIATE LIGHTING/ELECTRICAL FIXTURES FOR HAZARDOUS LOCATION IN SPACE ADJACENT TO AFTER STEERING, WHERE FLAMMABLES ARE LOCATED. SOLAS 60, II/27.
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Electrical
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE ANTI-SHOCK ELECTRICAL MATTING IN WAY OF SWITCHBOARD IN ROOM #D-14 ON BOAT DECK LEVEL. SOLAS 60, II/27
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Accommodation/Occupational Safety
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE FLAG STATE ATTESTATION AS TO CONDITION OF WATERCLOSETS THROUGHOUT VESSEL. PWSA, 33 USC 1223(B).
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Lifesaving
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION AS TO SERVICEABILITY OF TEMPORARY REPAIR TO STARBOARD LIFEBOAT. SOLAS 74 AMEN, III/19.2
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Navigation
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE CORRECT MANEUVERING FACT SHEET TO CG BOARDING OFFICER, INCLUDING DATA FOR HALF OR SLOW SPEED MANEUVERING. 33 CFR 164.35(G)
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Documentation
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, PROVIDE FLAG STATE APPROVAL FOR VSL SOPEP IN ACCORDANCEWITH MARPOL 73/78, ANNEX I, REG 26
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997
Accommodation/Occupational Safety
Issued 14 March 1997
Resolved
PRIOR TO DEPARTURE, MAKE HOSPITAL SPACE AVAILABLE FOR CG BOARDING OFFICER INSPECTION. PWSA, 33 USC 1223(B).
Condition: Unknown
Due 21 March 1997
Resolved 24 March 1997