TERRY BORDELON

TERRY BORDELON is a 2001 offshore supply vessel. The Coast Guard has recorded 14 inspections since 2016, most recently in October 2025, along with 21 deficiencies and 1 casualty investigation in 2010.

Records from 2010 to 2025. Most recent: inspection, 17 October 2025.

Built
2001
Last inspected
17 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 October 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9260744
WDM6583
Flag
UNITED STATES
Maury page id
psix-26700

Documentation record

Registered dimensions (L × B × D)130.8 ft × 36.0 ft × 11.5 ft
Registered tonnagegross 90 / net 50
ITC dimensions (L × B × D)130.8 ft × 36.0 ft × 11.5 ft
ITC tonnagegross 435 / net 136
BuilderBOLLINGER SHIPYARDS LOCKPORT LLC · LOCKPORT, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 December 2025 · expires 30 November 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it136 - Convention (Subpart B), Net Ton
50 - Regulatory (Subpart C or D), Net Ton
435 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

14 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

17 October 2025 Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 8254788
22 April 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8116136
23 May 2024 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7907582
25 April 2024 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7901560
11 October 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7806512
25 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7515935
9 June 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7473223
2 June 2022 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7465655
18 October 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7334627
23 September 2020 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7063868
17 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7085799
16 July 2019 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6752425
3 June 2019 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6702077
9 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6055428

Deficiency record · 21

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 April 2025 Resolved
Each penetration of a bulkhead in a machinery space must have means to make it watertight. The cable penetration entering the machinery space is not watertight due to an opening and incorrectly run cables.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: Company electrician renewed Rox Blocks, reran cables.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2025 Resolved
Electrical equipment must be maintained to protect persons from electrical hazard. Starboard breaker panel in the engine room had a blank which poses an electrical hazard.
Action required: 10 - Deficiency Rectified
Resolved 22 April 2025
Resolution: Blank cover installed.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 22 April 2025 Resolved
Line throwing appliance must have an auxiliary line that is at least 500 ft. long. There is not an auxiliar line on the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2025
Resolved 24 April 2025
Resolution: Aux line put onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2025 Resolved
Each cable must be supported to avoid chafing and damage. A/C cable coming out the side of the switchboard is not supported properly. The dead end wire coming out of the switchboard can cause damage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: Dead end cable removed, other cable properly run.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2024 Resolved
Electrical equipment must be designed to protect crew from electrical hazards. Switchboard and panel has open circut breaker openings.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 10 June 2024
Resolution: Installed proper cover.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 23 May 2024 Resolved
Vessel less than 100 GT must have fixed communication with auxilliary steering station. Sound powered phone inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 10 June 2024
Resolution: Technician provided report for repairs to system.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 October 2023 Resolved
Vessel must have adequate emergency lighting along line of escape to main deck from machinery spaces below. 2 emergency lights in the engine room passageway and mess deck did not work.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 7 November 2023
Resolution: Emergency light replaced, test sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 October 2023 Resolved
Watertight doors and watertight bulkheads must be watertight. Emergency escape hatch out of engine room is not properly adjusted. Engine room watertight door had a major gap in the gasket and was not watertight. A pinhole in the escape hatch was discovered.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2023
Resolution: Pinhole welded, WTD adjusted; all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 June 2022 Resolved
For each watertight door, an indicator light must be installed in the pilothouse that shows the door to be open or closed. The watertight door indicator was not installed (hanging down) to show the indication of the door being open or closed. 10JUN2022: Door indicator was installed. Two holes from prevous installiation observed and not welded. Changed to 30 days.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2022
Resolved 15 June 2022
Resolution: 10JUN2022: Door indicator was installed. Two holes from prevous installiation observed and not welded. Changed to 30 days. 17JUN22: Received email from Vessel Rep providing proof of welding holes to the satisfaction of the MI.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 June 2022 Resolved
Rudder Angle Indicator shall function properly. During Follow-Up steering test, the RAI showed the Port Rudder at over 40 degrees indicated when requesting 30 degrees stbd rudder at both stations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2022
Resolution: Vessel had technition out to recalibrate. When MI observed test, four degrees of deflection were noted. Vessel will have tech back out per their request to resolve 4 degree difference.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 June 2022 Resolved
Non-metallic fuel hoses shall be SAE J1942 compliant, no more than 30 inches, and in good condition. A non-metallic fuel hose on the stbd generator was observed to be chaffed with the outside layer frayed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2022
Resolved 15 June 2022
Resolution: Received email from Vessel Rep providing proof of correcting to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 June 2022 Resolved
Vessel shall be in a safe and seaworthy condition regarding fire hazards. The bow thruster/fire monitor engine's RACOR was leaking marine diesel fuel onto the deck.
Action required: 10 - Deficiency Rectified
Resolved 9 June 2022
Resolution: Cleared on the spot
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 June 2022 Resolved
A vessel of less than 100GRT shall have adequate emergency lighting along the line of escape. Vessel had two emergency lights that were not functional and needed adjusting to properly work (ER escape and bridge stairwell).
Action required: 10 - Deficiency Rectified
Resolved 9 June 2022
Resolution: Cleared on the spot.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 October 2021 Resolved
A radiotelephony station license must be kept onboard the vessel at all times. No radio station license was found onboard the vessel during the inspection. Vessel must show proof of radio station license onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 5 November 2021
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 18 October 2021 Resolved
Each refrigerated space that is accessible to the vessel's personnel must have an audible alarm system or be able to be opened from the inside. Refregirated space onboard was able to be locked from the outside but did not have a operable alarm associated with it. Either a working alarm must be demonstrated or the door must be made to open from the inside.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 4 November 2021
Resolution: Received video graphic results from repairs that are uploaded into documents. This meets the intent and is deemed safe for operations.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 18 October 2021 Resolved
Liferaft launching procedures must be posted for the crew in the vicinity of the liferaft. No instructions were seen near the liferaft. Vessel must show the instructions are now displayed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 4 November 2021
Resolution: Received video graphic results from repairs that are uploaded into documents. This meets the intent and is deemed safe for operations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 September 2020 Resolved
Means for securing doors shall consist of gasket and clamping devices; 03 water tight doors in the engine room had inadequate gaskets not allowing a closure seal; make repairs IAW stated regulation.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2020
Resolved 25 November 2020
Resolution: Vsl replaced gasket material and adjusted doors to rectify defs
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 23 September 2020 Resolved
Means must be provided for closing, in case of fire, each ventilator and annular space around funnels and other openings into such spaces, Engine room ventilation hatch was missing 09 bolts ineffectively securing the hatch; provide means for securing vent hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2020
Resolved 25 November 2020
Resolution: Vsl sealed vent access with new gasket material and replaced the missing bolts, rectifying deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 September 2020 Resolved
Must have a mechanical means of closing each scupper in container or enclosed deck area; 03 Port and 02 STBD discharge containment areas did not have drain plugs; Provide mechanical means meeting requirements per 33CFR155.310
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 25 November 2020
Resolution: Vsl installed missing scupper plugs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 September 2020 Resolved
A power-driven vessel underway shall exhibit sidelights; Vsl did not have lightbulb in PORT side side light; Install light meeting regulation.
Action required: 10 - Deficiency Rectified
Due 24 November 2020
Resolved 24 November 2020
Resolution: Vessel installed replacement bulbs
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 23 September 2020 Resolved
The master shall make periodic inspections of the quarters, galleys and the like; The oven range vent in the galley was found in a unsanitary state and without a screen; clean or replace to meet stated regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 25 November 2020
Resolution: Vsl cleaned and provided receipt for new vent screen.