TERRY BORDELON

TERRY BORDELON is a 2001 offshore supply vessel. The Coast Guard has recorded 41 inspections since 2001, most recently in October 2025, along with 44 deficiencies and 1 casualty investigation in 2010.

Records from 2001 to 2025. Most recent: inspection, 17 October 2025.

Built
2001
Last inspected
17 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9260744 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDM6583
Flag
UNITED STATES
366816910
Maury page id
psix-26700

Inspections, by type

…with no type recorded11
Years with a record 20 calendar years (2001–2025)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)130.8 ft × 36.0 ft × 11.5 ft
Registered tonnagegross 90 / net 50
ITC dimensions (L × B × D)130.8 ft × 36.0 ft × 11.5 ft
ITC tonnagegross 435 / net 136
BuilderBOLLINGER SHIPYARDS LOCKPORT LLC · LOCKPORT, LA, UNITED STATES · built 2001
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 December 2025 · expires 30 November 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it136 - Convention (Subpart B), Net Ton
50 - Regulatory (Subpart C or D), Net Ton
435 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM6583MMSI 366816910 · active · compulsorily equipped · granted 6 November 2021, expires 6 November 2031
WDA5140MMSI 366816910 · expired · compulsorily equipped · granted 28 June 2011, cancelled 28 August 2021
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

OCEAN AMBASSADOR Mobile Offshore Drilling Unit · MISLE 48504 · 5 March 2002 · activity 1637281

Inspection history · 41

17 October 2025 Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 8254788
22 April 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8116136
23 May 2024 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7907582
25 April 2024 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7901560
11 October 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7806512
25 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7515935
9 June 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7473223
2 June 2022 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7465655
18 October 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7334627
23 September 2020 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7063868
17 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7085799
16 July 2019 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6752425
3 June 2019 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6702077
9 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6055428
31 July 2015 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5206895
24 July 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4388920
27 February 2012 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4252019
23 February 2012 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4249491
7 February 2012 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4242060
25 February 2011 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 3954235
29 October 2010 Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 3882114
27 September 2010 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3856380
9 March 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3431090
30 September 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3335358
13 September 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3056775
2 July 2007 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2981761
13 April 2007 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2907489
29 June 2005 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2408043
1 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232330
2 July 2004 Cargo Tank Internal · Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2118521
5 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2017095
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2004023
30 January 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2017090
19 January 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2017070
20 October 2003 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1932005
9 September 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1672894
5 April 2002 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1614997
5 March 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1637281
24 January 2002 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1481191
11 July 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 53920
28 June 2001 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379554

Deficiency record · 44

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 April 2025 Resolved
Each penetration of a bulkhead in a machinery space must have means to make it watertight. The cable penetration entering the machinery space is not watertight due to an opening and incorrectly run cables.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: Company electrician renewed Rox Blocks, reran cables.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2025 Resolved
Electrical equipment must be maintained to protect persons from electrical hazard. Starboard breaker panel in the engine room had a blank which poses an electrical hazard.
Action required: 10 - Deficiency Rectified
Resolved 22 April 2025
Resolution: Blank cover installed.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 22 April 2025 Resolved
Line throwing appliance must have an auxiliary line that is at least 500 ft. long. There is not an auxiliar line on the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2025
Resolved 24 April 2025
Resolution: Aux line put onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 April 2025 Resolved
Each cable must be supported to avoid chafing and damage. A/C cable coming out the side of the switchboard is not supported properly. The dead end wire coming out of the switchboard can cause damage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2025
Resolution: Dead end cable removed, other cable properly run.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2024 Resolved
Electrical equipment must be designed to protect crew from electrical hazards. Switchboard and panel has open circut breaker openings.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 10 June 2024
Resolution: Installed proper cover.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 23 May 2024 Resolved
Vessel less than 100 GT must have fixed communication with auxilliary steering station. Sound powered phone inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 10 June 2024
Resolution: Technician provided report for repairs to system.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 October 2023 Resolved
Vessel must have adequate emergency lighting along line of escape to main deck from machinery spaces below. 2 emergency lights in the engine room passageway and mess deck did not work.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2023
Resolved 7 November 2023
Resolution: Emergency light replaced, test sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 October 2023 Resolved
Watertight doors and watertight bulkheads must be watertight. Emergency escape hatch out of engine room is not properly adjusted. Engine room watertight door had a major gap in the gasket and was not watertight. A pinhole in the escape hatch was discovered.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 October 2023
Resolution: Pinhole welded, WTD adjusted; all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 June 2022 Resolved
For each watertight door, an indicator light must be installed in the pilothouse that shows the door to be open or closed. The watertight door indicator was not installed (hanging down) to show the indication of the door being open or closed. 10JUN2022: Door indicator was installed. Two holes from prevous installiation observed and not welded. Changed to 30 days.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2022
Resolved 15 June 2022
Resolution: 10JUN2022: Door indicator was installed. Two holes from prevous installiation observed and not welded. Changed to 30 days. 17JUN22: Received email from Vessel Rep providing proof of welding holes to the satisfaction of the MI.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 June 2022 Resolved
Rudder Angle Indicator shall function properly. During Follow-Up steering test, the RAI showed the Port Rudder at over 40 degrees indicated when requesting 30 degrees stbd rudder at both stations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2022
Resolution: Vessel had technition out to recalibrate. When MI observed test, four degrees of deflection were noted. Vessel will have tech back out per their request to resolve 4 degree difference.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 June 2022 Resolved
Non-metallic fuel hoses shall be SAE J1942 compliant, no more than 30 inches, and in good condition. A non-metallic fuel hose on the stbd generator was observed to be chaffed with the outside layer frayed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2022
Resolved 15 June 2022
Resolution: Received email from Vessel Rep providing proof of correcting to the satisfaction of the MI.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 June 2022 Resolved
Vessel shall be in a safe and seaworthy condition regarding fire hazards. The bow thruster/fire monitor engine's RACOR was leaking marine diesel fuel onto the deck.
Action required: 10 - Deficiency Rectified
Resolved 9 June 2022
Resolution: Cleared on the spot
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 June 2022 Resolved
A vessel of less than 100GRT shall have adequate emergency lighting along the line of escape. Vessel had two emergency lights that were not functional and needed adjusting to properly work (ER escape and bridge stairwell).
Action required: 10 - Deficiency Rectified
Resolved 9 June 2022
Resolution: Cleared on the spot.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 October 2021 Resolved
A radiotelephony station license must be kept onboard the vessel at all times. No radio station license was found onboard the vessel during the inspection. Vessel must show proof of radio station license onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 5 November 2021
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 18 October 2021 Resolved
Each refrigerated space that is accessible to the vessel's personnel must have an audible alarm system or be able to be opened from the inside. Refregirated space onboard was able to be locked from the outside but did not have a operable alarm associated with it. Either a working alarm must be demonstrated or the door must be made to open from the inside.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 4 November 2021
Resolution: Received video graphic results from repairs that are uploaded into documents. This meets the intent and is deemed safe for operations.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 18 October 2021 Resolved
Liferaft launching procedures must be posted for the crew in the vicinity of the liferaft. No instructions were seen near the liferaft. Vessel must show the instructions are now displayed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 November 2021
Resolved 4 November 2021
Resolution: Received video graphic results from repairs that are uploaded into documents. This meets the intent and is deemed safe for operations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 September 2020 Resolved
Means for securing doors shall consist of gasket and clamping devices; 03 water tight doors in the engine room had inadequate gaskets not allowing a closure seal; make repairs IAW stated regulation.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2020
Resolved 25 November 2020
Resolution: Vsl replaced gasket material and adjusted doors to rectify defs
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 23 September 2020 Resolved
Means must be provided for closing, in case of fire, each ventilator and annular space around funnels and other openings into such spaces, Engine room ventilation hatch was missing 09 bolts ineffectively securing the hatch; provide means for securing vent hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2020
Resolved 25 November 2020
Resolution: Vsl sealed vent access with new gasket material and replaced the missing bolts, rectifying deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 September 2020 Resolved
Must have a mechanical means of closing each scupper in container or enclosed deck area; 03 Port and 02 STBD discharge containment areas did not have drain plugs; Provide mechanical means meeting requirements per 33CFR155.310
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 25 November 2020
Resolution: Vsl installed missing scupper plugs.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 September 2020 Resolved
A power-driven vessel underway shall exhibit sidelights; Vsl did not have lightbulb in PORT side side light; Install light meeting regulation.
Action required: 10 - Deficiency Rectified
Due 24 November 2020
Resolved 24 November 2020
Resolution: Vessel installed replacement bulbs
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 23 September 2020 Resolved
The master shall make periodic inspections of the quarters, galleys and the like; The oven range vent in the galley was found in a unsanitary state and without a screen; clean or replace to meet stated regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 25 November 2020
Resolution: Vsl cleaned and provided receipt for new vent screen.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 31 July 2015 Resolved
Fuel pump leaking
Action required: 705 - Other - as specified
Resolved 31 July 2015
Resolution: Leak stopped/corrected prior to completion of inspection
Documentation › Markings/Placards › Garbage Placard
Issued 31 July 2015 Resolved
Vsl still had old MARPOL Placard posted. No new MARPOL Placard.
Due 7 August 2015
Resolved 31 July 2015
Resolution: New Placard posted prior to completion of inspection.
Construction/Loadline › Structures › Door
Issued 31 July 2015 Resolved
Engine room water tight door needs adjustment to close properly
Action required: 705 - Other - as specified
Resolved 31 July 2015
Resolution: Water tight door adjusted prior to completion of inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 July 2015 Resolved
Electrical wiring in engine room supported by plastic wire ties
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2015
Resolution: Plastic wire tires replaced with metal wire ties
Lifesaving › Lifefloat › Float-free Link
Issued 31 July 2015 Resolved
Lifefloat float-free link installed where line could not pay out properly
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2015
Resolution: Float-free link adjusted so that line would pay out properly
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 7 February 2012 Resolved
Replace vinyl stack covers with adequate vent covers to properly seal during vessel fire.
Due 7 March 2012
Resolved 23 February 2012
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 27 September 2010 Resolved
Provide a new turbo line for port main deisel engine
Action required: 705 - Other - as specified
Resolved 29 September 2010
Communications › Radio Communications › VHF Radiotelephone
Issued 27 September 2010 Resolved
Provide Bridge to Bridge radio communications cert
Action required: 705 - Other - as specified
Resolved 29 September 2010
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 27 September 2010 Resolved
Provide fuel hose certification of hydro test prior to operation
Action required: 705 - Other - as specified
Resolved 29 September 2010
Engineering › Pressure Vessel › Relief Valve
Issued 27 September 2010 Resolved
Provide serial numbers for pressure relief valves
Action required: 705 - Other - as specified
Resolved 27 September 2010
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 September 2010 Resolved
Provide alcohol strips for each crew member on board
Action required: 705 - Other - as specified
Resolved 29 September 2010
Lifesaving › Line-Throwing Appliances › Lines
Issued 27 September 2010 Resolved
Provide spare auxillary line for line throwing gun
Action required: 705 - Other - as specified
Resolved 29 September 2010
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 27 September 2010 Resolved
Demonstrate proper operation of overspeed device on stbd unit
Action required: 705 - Other - as specified
Resolved 29 September 2010
Engineering › Pressure Vessel › Shell Plate
Issued 27 September 2010 Resolved
Remove paint on pressure vessel data plate
Action required: 705 - Other - as specified
Resolved 29 September 2010
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 September 2010 Resolved
Properly lable emergency escape in e/r
Action required: 705 - Other - as specified
Resolved 29 September 2010
Fire Fighting › Means of Escape › Doorways
Issued 27 September 2010 Resolved
Properly seal emergency escape hatch
Action required: 705 - Other - as specified
Resolved 29 September 2010
Communications › Public Address System › Announcing Station
Issued 27 September 2010 Resolved
Demonstrate proper operation of PA system on battery backup
Action required: 705 - Other - as specified
Resolved 29 September 2010
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 September 2010 Resolved
Demonstrate proper operation of E-Light in ladder well of e/r.
Action required: 705 - Other - as specified
Resolved 29 September 2010
Communications › Public Address System › Loudspeaker
Issued 30 September 2008 Resolved
Move PA speaker on 01 deck to service all berthing spaces.
Due 30 October 2008
Resolved 3 October 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 September 2008 Resolved
[name withheld] Fuel Shut off with identification and direction of closure
Due 30 October 2008
Resolved 3 October 2008
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 30 September 2008 Resolved
Label Breaker for Stove in galley area
Due 30 October 2008
Resolved 3 October 2008
Communications › Radio Communications › Emergency Source of Power
Issued 30 September 2008 Resolved
Repair emergency power source for required communications, VHF, SSB, etc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 January 2002 Resolved
properly repair collision bulkhead vertical angles caused by tank over pressurization.
Due 24 January 2002
Resolved 24 January 2002

Casualty record · 1

7 July 2010Routine · role: Involved in a Marine Casualty · activity 3789868
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.