Records from 1986 to 2003. Most recent: inspection, 23 October 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
23 October 2003
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1937061
23 October 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1941302
7 June 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 290842
6 December 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 435501
3 August 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 431405
21 November 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 422861
7 November 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 409760
3 June 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 404156
27 May 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 404135
7 October 1991
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 646806
18 September 1991
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 346159
6 June 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 344202
8 April 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 336366
14 February 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 499964
17 July 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 324535
13 August 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 317820
17 February 1987
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 314326
2 July 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 477701
25 February 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 307168
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 23 October 2003
No resolution recorded
Vent containment drains and deck scuppers did not have mechanical means of closure.
Condition: Improper Installation
Due 23 November 2003 — due date passed with no resolution recorded
Documentation › Certificates/Documents › International Load Line Certificate
Issued 23 October 2003
Resolved
MISLE showing document expired.
Due 23 October 2003
Resolved 23 October 2003
Resolution: updated document
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 23 October 2003
Resolved
MISLE showing document expired
Due 23 October 2003
Resolved 23 October 2003
Resolution: updated document
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 23 October 2003
Resolved
MISLE showing document expired
Due 23 October 2003
Resolved 23 October 2003
Resolution: updated document
Fire Fighting › Firemans Outfit › Helmet
Issued 23 October 2003
No resolution recorded
Fireman outfit's helmet is worn out and needs replacement.
Action required: 15 - Rectify deficiencies by next port
Due 24 October 2003 — due date passed with no resolution recorded
Fire Fighting
Issued 3 August 1999
Resolved
CEMENT SOFT PATCH IN PORT-SIDE FIRE/GENERAL SERVICE PUMP, DISCHARGE LINE ADJACENT PUMP INBOARD, ANNEX I/1. REPLACE AND/OR MAKE PERMANENT REPAIR TO SATISFACTION OF CLASS.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Navigation
Issued 3 August 1999
Resolved
MISSING CHART FOR NEXT PORT OF CALL (BATON ROUGE) 33CFR164.33. ACQUIRE CHART PRIOR TO DEPARTURE.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Lifesaving
Issued 27 May 1997
Resolved
MISSING SAFETY DAVIT LIMIT SWITCHES ON PORT AND STARBOARD LIFEBOATS._x001C_ (SOLAS 74, UNAMENDED, CH. III, REG. 48/2.5)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1997
Resolved 7 November 1997
Engineering
Issued 27 May 1997
Resolved
FLAME SCREENS IN POOR CONDITION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 June 1997
Resolved 3 June 1997
Navigation
Issued 18 September 1991
Resolved
CHARTS #14802, 14806, 14820, 14865, 14822, 14964, AND 14975 WERE_x001C_ MISSING. REQUIRED CHARTS FOR GREAT LAKES TRANSIT.
Condition: Unknown
Due 18 September 1991
Resolved 26 September 1991
Navigation
Issued 8 April 1990
Resolved
CHARTS NO 11413(APR84), AND 11414(OCT83) REQUIRED CHARTS FOR THE AREA OF SUBJ VSL'S TRANSIT, WERE OUTDATED EDITIONS WITH NO CORECTIONS. NO FOREIGN EQUIVALENTS WERE ONBOARD.MISSING NTM'S 2,9,12,AND 13 OF 1988 AND MANY MORE_x001C_CITE: 33 CFR 164.33/AUTHORITY: 33 USC 1231/MAX.CIVIL PENALTY: $25000.00
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Navigation
Issued 13 August 1987
Resolved
33CFR164.33(A)(1) THE HOUSTON SHIP CHANNEL CHARTS 11324,11327,11328 AND 11329 WERE NOT CORRECTED.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Navigation
Issued 13 August 1987
Resolved
33CFR164.33(A)(2)(I) THE COAST PILOT VOLUME V WAS OUTDATED.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Navigation
Issued 13 August 1987
Resolved
33CFR164.33(A)(2)(II) NO LIGHT LIST VOLUME IV ONBOARD.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Documentation
Issued 13 August 1987
Resolved
33CFR155.820(D) VESSEL DID NOT HAVE A COPY OF THE DECLARATION OF INSPECTION.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987