Inspection history · 20
2 June 2026
Vessel Attendance · Annual Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8355380
11 December 2025
Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8282064
30 September 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8244028
6 May 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8129931
15 August 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7981907
18 June 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7938046
7 November 2023
Examination of Repairs · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7831629
29 September 2023
Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7800733
15 June 2023
Deficiency Check · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7715911
8 May 2023
Deadweight Survey · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7675442
27 January 2023
Inclining Experiment
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7628924
10 January 2023
Construction Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7619736
19 July 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7509865
25 January 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7385718
11 May 2021
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7194585
30 April 2020
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6945655
9 August 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6777783
19 July 2018
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6488085
22 May 2018
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6437801
15 March 2016
Examination of Repairs · Plan Review "T" Boat · Administrative Inspection · Construction Oversight · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5833359
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 June 2026
Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Receptacle was plastic.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 30 June 2026
Resolution: Replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 June 2026
Resolved
The Certificate of Inspection certificates must be posted under glass or other suitable transparent material, such that all pages are visible. Original Certificate of Inspection was not available.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 25 June 2026
Resolution: original COI has been posted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 June 2026
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Drywall anchors were found to be used in bulkhead to mount a float switch.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 25 June 2026
Resolution: Drywall screws have been removed and a small doubler plate was welded to the bulkhead.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 June 2026
Resolved
At each inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. Two transverse frames in lazarette on the stern had cracks in welds.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 25 June 2026
Resolution: Welds have been repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 September 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] repairs on bow to be conducted and witnessed by a competent marine inspector.
46 CFR 176.700
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2024
Resolution: Permanent repairs made at drydock, deficiency rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 September 2023
Resolved
Whenever there is a hazardous condition, as defined by § 175.400 of this subchapter, on board the vessel, the owner, master, agent, or person in charge shall immediately notify the Captain of the Port. O/O failed to immediately notify the COTP of hazardous condition after allision with pier and did not conduct damage assessment immediately, then proceeded to sail with passengers on board.
46 CFR 185.203
Action required: 10 - Deficiency Rectified
Due 29 September 2023
Resolved 29 September 2023
Resolution: Deficiency recitified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2023
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment. While operating with passengers, the vessel ran aground causing damage to the starboard propeller. Vessel to drydock and make vessel available for a drydock inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2023
Resolved 27 June 2023
Resolution: Vessel drydocked and replaced both port and starboard propellers. Deficiency cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 8 May 2023
Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails.
The starboard vent-line valve in the lazarette was found inoperable.
46 CFR 179.350(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2023
Resolved 1 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2023
Resolved
Each lighting branch circuit must be protected against overcurrent either by fuses or circuit breakers rated at not more than 30 amperes.
Lighting branch circuit breaker within bridge switch board found inoperable.
46 CFR 183.380(g)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2023
Resolved 1 June 2023
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 8 May 2023
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck.
Vessel missing placard on upper deck.
46 CFR 185.602(g)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2023
Resolved 1 June 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 July 2022
Resolved
Examine and test by operation all watertight closures in the hull, decks and bulkheads. During the course of our inspection, cracks of approximately 5 inches and 3 inches were observed on the hatch ring to the forward void compartment. 46 CFR 176.25-5(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 26 August 2022
Resolution: The hatch and ring were replaced and tested.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 July 2022
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present. One penetration on the aft port side bulkhead separating the fuel tank compartment and the engine compartment was observed to not be vapor tight. 46 CFR 177.405(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 8 May 2023
Resolution: Penetration found to be properly sealed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 19 July 2022
Resolved
Glass and other glazing material used in windows accessible to passengers and crew must be of material that will not break into dangerous fragments if fractured. Two windows in the passenger space were observed to be broken. 46 CFR 177.1010
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 8 May 2023
Resolution: Broken windows were repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 19 July 2022
Resolved
Inspect all railings and bulwarks and their attachment to the hull structure. The port stanchion, second one forward from the stern, was observed to be completely parted at the weld. 46 CFR 176.25-5(a)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 26 August 2022
Resolution: Three stantions were repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 July 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Multiple medicines in the first-aid kit were found past their expiration date. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 8 May 2023
Resolution: Expired firstaid kit contents replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 July 2022
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. The expiration date for the batteries on two lifesaving water lights were passed their expiration dates.
46 CFR 185.726(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 8 May 2023
Resolution: Waterlight batteries replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 July 2022
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel’s name. The orange life buoy located on the upper deck was not marked with the vessel’s name. 46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 26 August 2022
Resolution: The vessel's name was placed on the lifering.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 July 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale o make safe navigation possible. The navigation chart carried on board the vessel was dated Sept 23, 2020 and was not updated. 46 CFR 184.420 (a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 26 August 2022
Resolution: A new chart was placed on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 July 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The starboard engine is leaking engine coolant at the head/block on #6 cylinder.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2022
Resolved 8 May 2023
Resolution: New engine installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 July 2021
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck, or, if it is readily accessible under service conditions, a screw-down valve without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead.
Screw down valve corroded and inoperable from the weather deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2021
Resolved 25 January 2022
Resolution: Inspected and exercised valve during DryDock. Found to be working as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Piping in tank room not given adequate support. Substitute wire ties for metal bracketing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2021
Resolved 12 October 2021
Resolution: Piping support replaced with metal bracketing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 July 2021
Resolved
Each floating waterlight must be approved in accordance with §161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110.
Per manufacturer's instruction, battery must be replaced annually and be of the screw cap terminal type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2021
Resolved 12 October 2021
Resolution: New battery with screw type terminals installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2020
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessels sea chest for generator has a pinhole leak. 46CFR177.300
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2020
Resolution: Pictures Sat
Fire Fighting › Fire Pumps › Capacity
Issued 22 May 2018
Resolved
Prior to carrying passengers, fire pump must pump a sufficient stream necessarily to put out a fire. Vessel's current fire pump is only putting out 18 psi.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2018
Resolved 24 May 2018
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 May 2018
Resolved
High water alarm at operating station in the Engine Room is audible but not visible.
Condition: Improper/Lack of Maintenance
Due 5 June 2018
Resolved 30 May 2018
Documentation › Certificates/Documents › FCC SSL
Issued 22 May 2018
Resolved
FCC Station License is order but not on boat. Provide USCG a valid station license.
Condition: Invalid
Due 5 June 2018
Resolved 30 May 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 May 2018
Resolved
Replace expired medication in first aid kit.
Condition: Improper/Lack of Maintenance
Due 5 June 2018
Resolved 30 May 2018