MAURY USCG vessel records
← All vessels

ZHEN HUA 18

Built
1985
Last inspected
30 March 2018
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 March 2018
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8026921
J8B3446
267162
Flag
SAINT VINCENT AND THE GRENADINES
Maury page id
psix-267162

Documentation record

Tonnage as PSIX records it28436 - Convention (Subpart B), Gross Ton
8530 - Convention (Subpart B), Net Ton
30650 - Dead Weight, Ton
49314 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 3 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

30 March 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6381915
27 March 2018 PI Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6371228
24 March 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6378531

Deficiency record · 3

Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 27 March 2018 Resolved
Accumulator batteries shall be suitably housed and compartments used for their accommodation shall be properly constructed. The batteries for the emergency air compressor in the engine room are held in place with wire and the terminals are covered with plastic bottles.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 2 April 2018
Resolution: Received and accepted class report. Report scanned to MISLE.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 27 March 2018 Resolved
Each separate circuit shall be protected against short circuit and overload. Inside the aft deck hydraulic room is a welder without this protection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 27 March 2018
Resolution: Corrected prior to completion of PSC exam.
Fire Fighting › Portable Foam Applicators › General
Issued 27 March 2018 Resolved
Maintenance, testing, and inspection shall be carried out based on the guidelines developed by the organization. The 135 L foam extinguisher by the boiler has a dry rotted discharge hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 27 March 2018
Resolution: Corrected prior to completion of PSC exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.