Records from 1986 to 2018. Most recent: inspection, 30 March 2018.
Inspection history · 30
30 March 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6381915
27 March 2018
PI Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6371228
24 March 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6378531
16 February 2011
ISPS III Exam · Ballast Water Examination · PI Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3946401
14 February 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3945194
14 February 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3945297
8 October 2010
ISPS III Exam · Ballast Water Examination · PI Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3866176
8 February 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3676154
4 February 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3675606
15 July 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3535631
13 April 2009
Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3451940
8 March 2007
PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2883922
5 March 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2885640
28 October 2005
Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2525818
18 December 2004
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2257122
24 August 2004
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2174798
6 March 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 388876
27 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 98155
8 September 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 370245
4 July 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 449912
28 March 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 357126
26 February 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 47598
2 December 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 347403
10 December 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 340773
21 July 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 331594
15 July 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 324455
19 May 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 316146
25 January 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 313858
28 November 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 454194
20 February 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 308407
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 27 March 2018
Resolved
Accumulator batteries shall be suitably housed and compartments used for their accommodation shall be properly constructed. The batteries for the emergency air compressor in the engine room are held in place with wire and the terminals are covered with plastic bottles.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 2 April 2018
Resolution: Received and accepted class report. Report scanned to MISLE.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 27 March 2018
Resolved
Each separate circuit shall be protected against short circuit and overload. Inside the aft deck hydraulic room is a welder without this protection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 27 March 2018
Resolution: Corrected prior to completion of PSC exam.
Fire Fighting › Portable Foam Applicators › General
Issued 27 March 2018
Resolved
Maintenance, testing, and inspection shall be carried out based on the guidelines developed by the organization. The 135 L foam extinguisher by the boiler has a dry rotted discharge hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2018
Resolved 27 March 2018
Resolution: Corrected prior to completion of PSC exam.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 16 February 2011
Resolved
0720 - A fireman's outfit shall consist of protective clothing to protect the skin from heat radiating from the fire. The reflective coating on both fireman's outfits are delaminated compromising the fireman's outfit's ability to provide fire protection from heat radiating from the fire. - SOLAS 74 II-2/17.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 February 2011
Resolved 6 June 2011
Resolution: Inspected fireman’s suits and found them in satisfactory condition. Also reviewed the class report.
Lifesaving › Lifebuoys › Quantity
Issued 8 February 2010
Resolved
0650 - The lifebuoy on the starboard bridge wing is holed. The inherent buoyancy is possibly affected. Address the replacement to the satisfaction of Class/Flag.
SOLAS 74(am) III/31
17ab
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2010
Resolved 11 February 2010
Resolution: Item cleared by Class Representative.
Stability › Unintentional Flooding › General
Issued 8 February 2010
Resolved
1282 - Multiple access plates for ballast water tanks on cargo deck were found with missing nuts and gasket material. Address to satisfaction of Class/Flag representative.
ICLL Reg 18(1)
17ab
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 February 2010
Resolved 11 February 2010
Resolution: Items cleared by Class Representative.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 8 February 2010
Resolved
1599 - A detailed voyage plan was not prepared to cover the entire voyage berth to berth, including those areas where the services of a pilot was used. No tide and current information and minimum clearance required under keel was present in the plan. The plan was signed by the Captain and deck Officers verifying voyage plan was accurate.
SOLAS 74(am) V/34
STCW A VIII/2
IMO Res A.893(21)
ISM
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2010
Resolved 11 February 2010
Resolution: Items cleared by Class Representative.
Navigation › Piloting/Steering › Marine Charts
Issued 8 February 2010
Resolved
1560 - Vessel did not have corrected charts for this port. There was also no evidence of position fixing on chart. Address to Satisfaction of Class/Flag.
SOLAS 74(am) V/19,27
33 CFR 164.33
ISM Code 7
17ab
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2010
Resolved 11 February 2010
Resolution: Items cleared by Class Representative.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 8 February 2010
Resolved
0635 - The Bousing tackle for the Port lifeboat is wasted beyond repair. The ship should have means to bring the survival craft against the ships side so the crew can be safely embarked. Address the inspection of all clocks and replacement to the satisfaction of Class/Flag.
SOLAS 74(am) III/36
ISM A/10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 February 2010
Resolved 16 April 2010
Resolution: Items cleared by Class Representative.
Lifesaving › Lifeboat › Hull
Issued 8 February 2010
Resolved
0610 - The port lifeboat is holed on the starboard quarter. In addition the aft gripes appear to be too tight as there is evidence of crushing where they make contact with the boat. Address to the satisfaction of Class/Flag.
SOLAS 74(am) III/13
ISM A/9,10
70ab
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 February 2010
Resolved 16 April 2010
Resolution: Items cleared by Class Representative.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 8 March 2007
Resolved
Crew has installed air blow down pipe for the CO2 system. Line comes up from engine room through the aft hydraulic pump room, in way of frame 25. Where the line passes thorough the deck there is no packing. Properly pack this opening to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 8 April 2007
Resolved 20 April 2009
Resolution: Received class report NY07SS00030 attesting to satisfactory repair.
Lifesaving › Hand Flares › Expired
Issued 24 August 2004
Resolved
Two parachute flarses were found to be expired on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2004
Resolved 31 August 2004
Lifesaving › Line-Throwing Appliances › Lines
Issued 24 August 2004
Resolved
Three line-throwing appliances were missing on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2004
Resolved 31 August 2004
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 24 August 2004
Resolved
Turbocharger cooling water drain wasted in several locations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2004
Resolved 31 August 2004
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 24 August 2004
Resolved
Lagging around oil transfer pump was found to be oil soaked. Lagging to be replaced to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2004
Resolved 31 August 2004
Engineering › Freshwater System (piston cooling) › Piping
Issued 24 August 2004
Resolved
Piston cooler for main engine has temporary repairs on inlet and outlet for freshwater.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2004
Resolved 31 August 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 August 2004
Resolved
Generator cooling line above cascade tank (located port side 2nd level of E/R) is wasted in several locations. Class survayor to make recomendationtions for repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2004
Resolved 31 August 2004
Lifesaving › Launching Appliances › Davit
Issued 24 August 2004
Resolved
Class Society Surveyor to attest to the proper operation of both port and starboard lifeboat davit limit switches.
Action required: 705 - Other - as specified
Due 24 September 2004
Resolved 31 August 2004
Engineering
Issued 6 March 1996
Resolved
Provide mechanical plugs for fuel oil containment prior to bunkering in theUnited States. 33 CFR 155.320
Condition: Unknown
Due 8 March 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 6 March 1996
Resolved
Make pe3rmant repairs to oily water separator in way of bottom fwd 2 inch pipe. Weld cracked. Repair to be made prior to returning to any United States port. 33CFR 159.380, MARPOL 73/78 Annex 1 Reg 16.
Condition: Unknown
Due 8 March 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 8 September 1994
Resolved
THE VESSELS EMERGENCY FIRE PUMP FAILED TO PROVIDE ADEQUATE PRESSURE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 September 1994
Resolved 12 September 1994
Fire Fighting
Issued 8 September 1994
Resolved
FIVE(5) FIRE HOSES ON THE MAIN DECK OF THE VESSEL WERE WORN AND LEAKED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 September 1994
Resolved 12 September 1994