MAURY USCG vessel records Sign in
← All vessels

PATRIOT

PATRIOT is a 1986 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1986, most recently in May 2025, along with 71 deficiencies and 1 operational control.

Records from 1986 to 2025. Most recent: inspection, 7 May 2025.

Built
1986
Last inspected
7 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAV6438
267194
Flag
UNITED STATES
367099460
Maury page id
psix-267194

Inspections, by type

…with no type recorded6
Years with a record 35 calendar years (1986–2025)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 20.0 ft × 7.0 ft
Registered tonnagegross 60 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX BROS. SHIPYARD · LOREAUVILLE, LA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEWPORT BEACH, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Simplified, Gross Ton
48 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAV6438MMSI 367099460 · active · compulsorily equipped · granted 11 April 2026, expires 24 May 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

7 May 2025 Appeal · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8080924
31 March 2025 Plan Review "T" Boat · Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8092550
30 January 2025 Hull Examination · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8036552
20 February 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7846810
20 March 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7633582
12 January 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7601298
22 August 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7541460
9 February 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7393444
22 November 2021 Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7356487
13 October 2021 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7332229
1 March 2021 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7141483
20 January 2021 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7127238
20 May 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6923206
15 April 2019 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6659128
9 January 2019 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6604907
17 April 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6376727
9 May 2017 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6129147
9 February 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6081993
22 February 2016 DAPI Audit · Internal Structural Exam · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5813760
24 February 2010 Type not recorded
No type recorded · USCGC BLACKFIN (WPB 87317) · USCG Southwest District (CGD-SW) · Activity 3693988
18 March 2009 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3434599
8 May 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3167694
19 April 2007 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2907284
4 April 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2898365
27 March 2006 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2602576
2 June 2005 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2384241
19 April 2005 Hull Examination · Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2326281
19 April 2005 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2337770
29 April 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2054833
28 April 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1779370
18 April 2003 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1776046
11 June 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1629115
8 November 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440595
23 April 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362410
27 March 2001 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406895
10 April 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1445605
4 May 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1399103
13 April 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1360804
30 March 1998 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1454532
10 April 1997 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1441198
4 April 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1430166
25 April 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 860532
6 April 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 844727
5 April 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1178362
14 April 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 857459
11 April 1994 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1165949
13 April 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 834293
6 April 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 838138
27 October 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 951206
6 April 1992 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 947950
6 June 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1242566
25 March 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 996836
19 March 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 917220
28 November 1990 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 917772
7 May 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1242139
19 September 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1318062
28 June 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1204206
11 April 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1031106
8 November 1988 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1205333
21 April 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1037950
28 October 1987 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1017948
8 July 1987 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1323946
20 March 1987 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1016613
3 March 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1314587
1 May 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1307958
17 April 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299905

Deficiency record · 71

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2025 Resolved
Rails on passenger decks of a ferry or a vessel engaged in excursion trips, including but not limited to sightseeing trips, dinner and party cruises, and overnight cruises, must be at least 1,000 millimeters (39.5 inches) high. Vessel's rails are lower than 39.5 inches. Provide plan for correction to Marine Inspector. 46 CFR 177.900(d)(1) 46CFR177.35-1(c)(Old-T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2025
Resolved 9 July 2025
Resolution: This deficiency has been overturned as part of an OCMI reconsideration, and as such has been marked as cleared. See MISLE activity 8080924 and associated correspondence for additional information.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2025 Resolved
excursion trip the following must be installed: Bulwarks; Chain link fencing or wire mesh that has openings of not more than 4 inches in diameter; or bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches). Provide plan to Marine Inspector for the installation of rail courses that meet the standard listed above. 46 CFR 177.900(g)(1) 46CFR177.35-1(c)(Old-T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2025
Resolved 9 July 2025
Resolution: This deficiency has been overturned as part of an OCMI reconsideration, and as such has been marked as cleared. See MISLE activity 8080924 and associated correspondence for additional information.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 May 2025 Resolved
A power-driven vessel underway shall exhibit: a masthead light; sidelights and a sternlight. Vessel's stern light was found inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 8 May 2025
Resolution: Stern light was repaired satisfactorily.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 May 2025 Resolved
A vessel of less than 50 meters in length may exhibit an all-round white light where it can best be seen. Vessel's all-round (anchor) light was found inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 9 May 2025
Resolution: Anchor light repaired and in service.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 May 2025 Resolved
he requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First-Aid kit was found missing required items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 8 May 2025
Resolution: Vessel procured First-Aid kit containing all required items.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 7 May 2025 Resolved
xcept as allowed by paragraph (d) of this section, each vessel constructed of a material other than wood certificated to operate on a limited coastwise route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. One 22-person life float has a broken lifeline tab. Vessel limited to 72 total persons onboard until life float is repaired to the satisfaction of the attending Marine Inspector. Code 705c: Vessel limited to 72 Persons oboard
Action required: 705 - Other - as specified
Resolved 16 May 2025
Resolution: Lifeline tab repaired to the satisfaction of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 20 February 2024 Resolved
The float-free link required by § 180.130(a)(1) must be: (2)Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Marine Inspector noticed that the float free link's identification tag was missing. 46 CFR 180.137 (b)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2024
Resolved 26 February 2024
Resolution: Received photo evidence of new weak link with tag properly installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 February 2024 Resolved
Footholds, handholds, ladders, and similar means provided to aid escape, must be suitable for use in emergency conditions, of rigid construction, and permanently fixed in position, unless they can be folded, yet brought into immediate service in an emergency. Marine Inspector noticed the ladder in the lazarette space had two rungs that were no longer serviceable and wasted away.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2024
Resolved 12 March 2024
Resolution: Ladder rungs in lazarette have been repaired.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 March 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Audible alarm and light was inoperable on bridge serving galley bilge. 46CFR182.525(a)(2)
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 20 March 2023
Resolved 20 March 2023
Resolution: Operator was able to rectify. Audible alarm and light in satisfactory condition.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 March 2023 Resolved
If the vessel carries more than one life float or buoyant apparatus in a group with each group secured by a single painter:Each life float and buoyant apparatus must be individually attached to the painter. Painter line was found disconnected and not properly attatch to life floats. 46CFR180.137(e)(3)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 March 2023
Resolved 20 March 2023
Resolution: Operator and crew properly attached painter line to life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 March 2023 Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. 46CFR185.604(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2023
Resolved 24 March 2023
Resolution: Received pictures of persons capacity proper marked. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 March 2023 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. 46CFR185.604(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2023
Resolved 24 March 2023
Resolution: Revied pictures of proper marked life float paddles. All Sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 August 2022 Resolved
All portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. The salon portable fire extinguisher was not charged as evidenced by the indicator being in the red and no servicing tag was present.
Action required: 10 - Deficiency Rectified
Due 22 August 2022
Resolved 22 August 2022
Resolution: Extinguisher was replaced with new extinguisher with indicator in the green and servicing tag attached. Servicing month August, 2022.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 February 2022 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The galley's bilge high level indicating light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2022
Resolved 10 February 2022
Resolution: Operator sent video and proof of proper light operation for the galley's high level alarm indicating light.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 February 2022 Resolved
Each life jacket must be marked with Type I retroreflective material. 25 Child size life jacket retroreflective tape needs replaced.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 9 February 2022
Resolution: Retroreflective tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 February 2022 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroflective material. Two of the life bouy's need retroreflective tape replaced.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 9 February 2022
Resolution: Retroreflective tape replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 February 2022 Resolved
Transverse watertight bulkhead had cable penetrations that were not watertight.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 9 February 2022
Resolution: The penetrations were appropriately made water tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2022 Resolved
MI identified two wasted steering hydraulic line hangers in the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 9 February 2022
Resolution: Both were immediately replaced with new hangers by vessel crew.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2020 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps prohibited. Butterfly nuts installed on all batteries. Remove and replace with permanent type hardware.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 20 May 2020
Resolved 20 May 2020
Resolution: Removed butterfly nuts at terminals and replaced with permanent type hardware.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2020 Resolved
Electrical equipment on vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards. Battery switch cable ends were found disconnected in engine room. Upon new battery switch cable installation, old cable installation had not been removed. Removed on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 May 2020
Resolved 20 May 2020
Resolution: Removed old battery switch cable.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 April 2019 Resolved
Permanently affix fresh water tank in compartment beneath galley. 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2019
Resolved 13 May 2019
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 May 2017 Resolved
Provide 12 additional life jackets (adult size) to bring total to 90 adult life jackets. Vessel's passenger count reduced to 78 persons.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 16 May 2017
Construction/Loadline › Hull › Hull Plating
Issued 9 February 2017 Resolved
Clad weld pit located below port shaft in engine room.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 8 March 2017
Resolution: Operator had the pit clad welded to the satisfaction of the attending MI.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 February 2016 Resolved
Provide 26 adult life jackets, restricted to 62 adult passengers IAW 46 CFR 180.71(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 February 2016
Resolution: Provided 26 adult lifejackets.
Navigation › Piloting/Steering › Marine Charts
Issued 22 February 2016 Resolved
Provide large scale chart for Catalina and Long Beach IAW 46 CFR 184.420(a).
Action required: 705 - Other - as specified
Due 4 March 2016
Resolved 26 February 2016
Resolution: Provided updated charts for Catalina and Long Beach
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2016 Resolved
Provide metallic supports for all electrical wiring, with spacing no more than 24 inches IAW 43 CFR 183.340(b)(4).
Action required: 705 - Other - as specified
Due 4 March 2016
Resolved 26 February 2016
Resolution: provided metallic supports for electrical wiring.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 8 May 2008 Resolved
PROVIDE SATISFACTORY MEANS TO RECOVER A HELPLESS PERSON FROM THE WATER
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 10 June 2008
Resolution: Provided satisfactory invoice for lifesling.
Navigation › Piloting/Steering › Marine Charts
Issued 8 May 2008 Resolved
PROVIDE CURRENT CHARTS FOR VESSEL'S OPERATING AREA.
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 10 June 2008
Resolution: RCVD SATISFACTORY INVOICE FOR CURRENT CHARTS.
Fire Fighting › Fire Main › Material
Issued 4 April 2007 Resolved
Provide fire pump with proper materials and installation IAW 46 CFR 181 and 182. Reduced passenger count to 49 maximum until rectified and NLT 11 Apr 2007. Three fire buckets must be carried in leui of fire pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2007
Resolved 6 April 2007
Resolution: Provided fire pump with proper materials and installation IAW 46 CFR 181 and 182.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 April 2007 Resolved
Provide adequate guards for exposed moving machinery in engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 19 April 2007
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 4 April 2007 Resolved
Replace raw water hose with approved SAE J-1942 hose.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 19 April 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 4 April 2007 Resolved
Provide wire clamps for unsecured wire under helm console.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 19 April 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 4 April 2007 Resolved
Hard-wire magnetic compass light.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 19 April 2007
Lifesaving › Lifefloat › Float-free Link
Issued 4 April 2007 Resolved
Provide "containment can" for lifefloat painter topside bridge.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 1 May 2007
Resolution: Provided "containment can" for lifefloat painter topside bridge.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 4 April 2007 Resolved
Renew hydraulic fitttings for anchor winch on bow.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 19 April 2007
Fire Fighting › Nozzles › Number
Issued 4 April 2007 Resolved
Provide nozzle for each fire hose onboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 19 April 2007
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 3 May 2005 Resolved
Four of six Racor fuel filters missing metallic bowls at bases.
Condition: Unknown
Due 3 June 2005
Resolved 2 June 2005
Resolution: Renewed four missing fuel filter matalic bases.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 3 May 2005 Resolved
Ventilation exhaust duct over grill inoperable as required IAW 46CFR177.600.
Condition: Unknown
Due 3 June 2005
Resolved 2 June 2005
Resolution: Proved proper operation of grill ventilation exhaust duct.
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 May 2005 Resolved
Bulkhead penetrations from compartment no.2 to no.3 on stbd. side for hydraulic lines missing metallic fitting IAW 46CFR182.720(d)(1)(i).
Condition: Improper Installation
Due 3 June 2005
Resolved 2 June 2005
Resolution: Renewed missing matalic fittings.
Construction/Loadline › Structures
Issued 11 June 2002 Resolved
Renew/Repair cracked window in pilothouse. LEGACY COMPONENT DESC: Superstructure
Condition: Damaged By Earlier Event
Due 11 July 2002
Resolved 11 July 2002
Lifesaving › Buoyant Apparatus
Issued 11 June 2002 Resolved
Renew/Repair lifefloat. Due to cracks in exterior coating, repairs required.
Condition: Unknown
Due 11 July 2002
Resolved 11 July 2002
Lifesaving
Issued 8 November 2001 Resolved
Provide bult guards on front of each main engine.
Condition: Unknown
Due 22 November 2001
Resolved 11 June 2002
Electrical
Issued 8 November 2001 Resolved
Secure new main engine wire looms overhead of engine room every 24 inches with metal hangars.
Condition: Unknown
Due 22 November 2001
Resolved 11 June 2002
Engineering
Issued 8 November 2001 Resolved
Clamp fuel hoses installed on main engines where push-on fittings were used, at the push-on fitting.
Condition: Unknown
Due 22 November 2001
Resolved 11 June 2002
Construction/Loadline
Issued 23 April 2001 Resolved
Provide captives for lazerette and engine room hatch covers.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Engineering
Issued 23 April 2001 Resolved
Replace port and starboard cutless bearings.
Condition: Unknown
Due 30 August 2001
Resolved 30 August 2001
Lifesaving
Issued 27 March 2001 Resolved
Life floats stacked over 4ft high as per 46 CFR 180.137(f). Issued requirement to correct on worklist.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Lifesaving
Issued 27 March 2001 Resolved
Replace all expired items in first aid kit.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 13 April 1999 Resolved
Replace cutlass bearing on port side shaft.
Condition: Unknown
Due 1 May 1999
Resolved 21 April 1999
Engineering
Issued 13 April 1999 Resolved
Repair or replace port side propeller.
Condition: Unknown
Due 1 May 1999
Resolved 21 April 1999
Construction/Loadline
Issued 13 April 1999 Resolved
Repair pitting in compartment aft of collision bulkhead directly below hatch.
Condition: Unknown
Due 1 May 1999
Resolved 21 April 1999
Construction/Loadline
Issued 13 April 1999 Resolved
Secure aft most hatch cover.
Condition: Unknown
Due 21 May 1999
Resolved 5 May 1999
Lifesaving
Issued 4 April 1996 Resolved
CONDUCT EMERGENCY DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Construction/Loadline
Issued 4 April 1996 Resolved
MAKE PERMANENT REPAIR TO SUCTION LINE FOR BAIT TANK OUTBOARD OF SEA VALVE IN LAZARETTE.
Condition: Unknown
Due 8 April 1996
Resolved 8 April 1996
Construction/Loadline
Issued 11 April 1994 Resolved
INSTALL PROPER METALLIC PIPE BETWEEN VESSEL'S SKIN AND SEA VALVE ON BAIT_x001C_ TANK SUCTION LINE IN LAZARETTE.
Condition: Unknown
Due 25 April 1994
Resolved 18 April 1994
Navigation
Issued 11 April 1994 Resolved
PROVIDE CORRECTED/UPDATED COAST PILOT, CHARTS, AND LIGHT LIST FOR AREA OF OPERATIONS.
Condition: Unknown
Due 11 May 1994
Resolved 18 April 1994
Fire Fighting
Issued 11 April 1994 Resolved
PROVIDE METALLIC FIRE HOSE NOZZLES FOR BOTH (2) FIRE HOSES.
Condition: Unknown
Due 25 April 1994
Resolved 18 April 1994
Electrical
Issued 6 April 1992 Resolved
PROVIDE ADDITIONAL METALLIC WIRE BRACKETS EVERY 24" FOR ELECTRICAL CABLES IN FUEL TANK SPACE.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Fire Fighting
Issued 6 April 1992 Resolved
PROVIDE APPROPRIATE PORTABLE FIRE EXTINGUISHER MOUNTING BRACKET FOR B-II EXTINGUISHER, ENGINEROOM AFTER BULKHEAD, STARBOARD SIDE.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Electrical
Issued 6 April 1992 Resolved
REPAIR WIRE GUARD/INSULATION AND PROVIDE WIRE BRACKET FOR CABLE ABOVE STARBOARD ENGINE.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Fire Fighting
Issued 6 April 1992 Resolved
SERVICE OR REMOVE B-II PORTABLE FIRE EXTINGUISHER IN MAIN CABIN (AFT PORT SIDE) WHICH HAS LOST CHARGE.
Condition: Unknown
Due 6 April 1992
Resolved 6 April 1992
Engineering
Issued 7 May 1990 Resolved
REPAIR OR RENEW: PORT ENGINE THROTTLE CABLE; AND STARBOARD ENGINE STOP CABLE.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Construction/Loadline
Issued 7 May 1990 Resolved
RENEW STUFFING IN BULKHEAD STUFFING TUBES AS NEEDED.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Lifesaving
Issued 7 May 1990 Resolved
SUPPLY SIX ORANGE SMOKE FLARES FOR VESSEL.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Lifesaving
Issued 7 May 1990 Resolved
RENEW OR REPAIR 2 OF 3 BOUYANT APPARATUS WATER LIGHTS.
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Lifesaving
Issued 11 April 1989 Resolved
REPAIR EPIRB.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Documentation
Issued 11 April 1989 Resolved
PROVIDE DUPLICATE COPY OF FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Documentation
Issued 11 April 1989 Resolved
POST COPY OF STABILITY LETTER WHEN RECIEVED.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Electrical
Issued 11 April 1989 Resolved
INSTALL SUPPORT BRACKET ON GENERATOR EXHAUST PIPE.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Engineering
Issued 11 April 1989 Resolved
ADD SECOND HOSE CLAMP TO EACH OF TWO HOSES IN THE PORT MAIN ENGINE COOLING SYSTEM.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Engineering
Issued 21 April 1988 Resolved
RE-NEW BOTH MAIN ENGINE INTAKE SEA VALVES.
Condition: Unknown
Due 21 April 1988
Resolved 21 April 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.