Records from 1994 to 2003. Most recent: inspection, 7 March 2003.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 March 2003
No resolution recorded
Light fixtures in several accommodation rooms were rewired and creates an electrical shock/fire hazard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 7 March 2003
No resolution recorded
Installed rudder angle indicators are inaccurate from 20 degrees starboard to hard starboard (installed rudder angle indicator on bridge steering console is accurate, all other angle repeatore are off as noted).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Lifesaving › Launching Appliances › Davit
Issued 7 March 2003
No resolution recorded
Davits are creating stress cracks near forward keel of both lifeboats. LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Fire Fighting
Issued 21 March 1995
Resolved
REPAIR/RENEW AND PROVE OPERATION OF ALL MAIN INLETS AND OUTLETS OF ALL VENTILATION SYSTEMS THAT ARE CAPABLE OF BEING CLOSED FROM OUTSIDE THE SPACEIN THE EVENT OF A FIRE PRIOR TO RENTRY TO NEXT U.S. PORT.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Engineering
Issued 21 March 1995
Resolved
REPAIR AND PROVE OPERATION OF REMOTE SHUTDOWNS OF POWER VENTILATION.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Fire Fighting
Issued 21 March 1995
Resolved
REPAIR AND PROVE OPERATION OF FIRE PUMP RELIEF VALVE LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Engineering
Issued 21 March 1995
Resolved
REPAIR AND PROVE OPERATION OF THE MEANS FOR STOPPING VENTILATING FANS SERVING MACHINERY AND CARGO SPACES AND FOR CLOSING ALL DOORWAYS VENTILATORS, ANNULAR SPACES AROUND FUMMELS AND OTHER OPENINGS TO SUCH SPACES.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Lifesaving
Issued 21 March 1995
Resolved
PORT SIDE OUTBOARD LIFERAFT CASING, HOLED AND CRUSHED.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Lifesaving
Issued 21 March 1995
Resolved
ENSURE ALL SELF-IGNITING LIGHTS ON LIFBUOYS ARE IN GOOD WORKING ORDER.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Lifesaving
Issued 21 March 1995
Resolved
ENSURE QUICK RELEASES FOR LIFEBUOYS ON THE BRIDGE WINGS ARE CAPABLE OF BEING RELEASED.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Lifesaving
Issued 21 March 1995
Resolved
ENSURE ALL LIFEBOAT FALLS ARE READY FOR SERVICE. THE LIFEBOAT FALLS WERE SEIZED AND THE LIFEBOATS COULD NOT BE LOWERED.
Condition: Unknown
Due 25 March 1995
Resolved 19 April 1995
Navigation
Issued 21 March 1995
Resolved
PROVIDE DAY SHAPES, IN ACCORDANCE WITH INTERNATIONAL REGULATIONS FOR PREVENTING COLLISIONS AT SEA IN FORCE.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Navigation
Issued 21 March 1995
Resolved
PROVIDE A BELL OR GONG WITH PROPER INTENSITY OF SIGNAL IN ACCORDANCE WITH INTERNATIONAL REGULATIONS FOR PRVENTING COLLISIONS AT SEA IN FORCE.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Lifesaving
Issued 21 March 1995
Resolved
THE EPIRB'S HYDROSTATIC RELEASE MUST BE OPERATIONAL.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Engineering
Issued 21 March 1995
Resolved
PROVE OPERATION OF THE OILY WATER SEPERATOR. CREW UNABLE TO DEMONSTRATE OPERATION OF OILY WATER SEPERATOR.
Condition: Unknown
Due 25 March 1995
Resolved 19 April 1995
Fire Fighting
Issued 21 March 1995
Resolved
RENEW FIRE HOSES THROUGHOUT THE VESSEL TO ENSURE COMPLETE INTERCHANGEABILITY OF HOSE COUPLINGS AND NOZZLES.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Fire Fighting
Issued 21 March 1995
Resolved
RENEW HOLED DRY ROTTEN AND DETERIORATED FIRE HOSES THROUGHOUT THE VESSEL. SUFFICIENT NUMBER ARE TO BE AVAILABLE AND ACCESSIBLE AT ALL TIME.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Fire Fighting
Issued 21 March 1995
Resolved
REPAIR AND PROVE OPERATION OF FIXED EMERGENCY FIRE PUMP.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Fire Fighting
Issued 21 March 1995
Resolved
ALL FIRE HOSE STATIONS IN MACHINERY SPACES SHALL BE PROVIDED WITH NOZZLES SUITABLE OF SPRAYING WATER ON OIL OR ALTERNATIVELY DUAL PURPOSE NOZZLES.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Fire Fighting
Issued 21 March 1995
Resolved
SERVICE ALL PORTABLE AND SEMI-PORTABLE FIRE EXTINGUISHERS THROUGHOUT THE VESSEL TO ENSURE GOOD ORDER AND AVAILABILITY FOR IMMEDIATE USE.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Engineering
Issued 21 March 1995
Resolved
REPAIR/RENEW AND PROVE OPERATION OF REMOTE CONTROLS, SITUATED OUTSIDE THE SPACE CONCERNED, FOR MACHINERY DRIVING FORCED AND INDUCED DRAFT FANS, OIL FUEL TRANSFER PUMPS, OIL/FUEL UNIT PUMPS AND OTHER SIMILAR FUEL PUMPS SO THAT THEY MAY BE STOPPED IN THE EVENT OF A FIRE ARISING IN THE SPACE.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Engineering
Issued 21 March 1995
Resolved
REPAIR/RENEW AND PROVE OPERATION OF REMOTE SHUTDOWNS OF EVERY OIL/FUEL SUCTION PIPE FROM A STORAGE SETTLING OR DAILY SERVICE TANK SITUATED ABOVE THE DOUBLE BOTTOM THATS CAPABLE OF BEING STOPPED OUTSIDE THE SPACE CONCERNED.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Lifesaving
Issued 21 March 1995
Resolved
PROVIDE OPERATING INSTRUCTIONS IN THE FORM OF POSTERS OR SIGNS ON OR IN THEVICINITY OF SURVIVAL CRAFT AND THEIR LAUNCHING CONTROLS IN ACCORDANCE WITH SOLAS 74 AMENDED III/9.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Engineering
Issued 21 March 1995
Resolved
REPAIR AND PROVE OPERATION OF ALL POWER VENTILATION THROUGHOUT THE VESSEL.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Navigation
Issued 21 March 1995
Resolved
INBOARD SCREENS FOR SIDELIGHTS SHALL BE PAINTED MATT BLACK.
Condition: Unknown
Due 26 February 1998
Resolved 26 February 1998
Fire Fighting
Issued 21 March 1995
Resolved
INSTALL FIXED FIRE SUPPRESSION SYSTEM FOR PAINT LOCKER AND FLAMMABLE LIQUIDLOCKERS.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Lifesaving
Issued 21 March 1995
Resolved
PROVIDE LIFEBOAT EQUIPMENT FOR EACH LIFEBOAT.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Lifesaving
Issued 21 March 1995
Resolved
RENEW DETERIORATED OARS FOR EACH LIFEBOAT.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Fire Fighting
Issued 21 March 1995
Resolved
CONDUCT A HYDROSTATIC TEST OF ALL FIREHOSES IN ENGINEROOM IN THE PRESENCE OF A U.S. COAST GUARD INSPECTOR/BOARDING OFFICER. NUMEROUS FIRE HOSES THROUGHOUT THE VESSEL SHOW SIGNS OF WEAR AND DETERIORATION.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995
Lifesaving
Issued 21 March 1995
Resolved
RENEW DETERIORATED AND DRY-ROTTED LIFELINES THAT ARE FITTED TO THE DAVIT SPAN ON EACH LIFEBOAT.
Condition: Unknown
Due 25 March 1995
Resolved 27 March 1995