Documentation record
Registered dimensions (L × B × D)54.8 ft × 15.8 ft × 8.4 ft
Registered tonnagegross 48 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA RAY DIVISION OF BRUNSWICK CORP · KNOXVILLE, TN, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHICAGO, IL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 25 July 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Simplified, Net Ton
48 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
12 September 2025
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8233181
26 July 2024
COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7967676
29 August 2023
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7778874
28 March 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7658183
5 July 2022
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7496595
29 June 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7239108
4 December 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7106185
10 September 2020
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7055661
15 August 2020
Type not recorded
No type recorded · Station (Small) Wilmette Harbor · USCG Great Lakes District (CGD-GL) · Activity 7034548
21 August 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6790146
18 August 2019
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6787850
2 August 2019
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6770399
4 April 2019
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6655588
30 July 2018
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6495817
26 July 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6496537
17 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6482240
7 February 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6351761
29 August 2017
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6254326
27 July 2017
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6247646
24 July 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6220017
14 June 2017
Type not recorded
No type recorded · Coast Guard Station Chicago · USCG Great Lakes District (CGD-GL) · Activity 6188465
7 April 2017
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6119816
1 August 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5962307
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2020
Resolved
Missing switch cover plate for lights in crew storage room. Replace cover plate to satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 4 December 2020
Resolution: Switch cover plate for light in crew storage room has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 September 2020
Resolved
Floating waterlight must be attached around the body of the life buoy. Stow floating waterlight so that it is attached around the body of the life buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2020
Resolved 4 December 2020
Resolution: Floating waterlight has been attached to life buoy for stowage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2020
Resolved
Life buoy lifeline is 50 feet. Lifeline must be at least 60 feet in length. Replace lifeline with at least 60 feet.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2020
Resolved 4 December 2020
Resolution: Life buoy lifeline is now 90 feet.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 August 2019
Resolved
Complete repairs toport side bow.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 1 March 2020
Resolved 26 August 2019
Resolution: Completed repairs on Port bow.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 August 2019
Resolved
1 of 3 fire buckets cracked. Replace fire bucket with one 2.5 gallon bucket with lanyard.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 28 August 2019
Resolved 21 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 August 2019
Resolved
Properly mark both ring buoys with SOLAS tape 4 bands and renew grab line main deck ring buoy.
Action required: 60 - Rectify deficiencies prior to movement
Due 28 August 2019
Resolved 21 August 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 July 2018
Resolved
Prior to carrying passengers make vessel available for dry dock inspection.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 31 July 2018
Resolved 26 July 2018
Resolution: Conducted drydock.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 July 2017
Resolved
Provide approved first aid kit
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 28 August 2017
Resolution: first aid kit updated
Documentation › Logs/Records › Drug Test Records
Issued 24 July 2017
Resolved
Provide proper documentation for DAPI information
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 28 August 2017
Resolution: MIS, Pre-Employment reviewed
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 July 2017
Resolved
Vessel passenger count is reduced by 4. COI has 42 person. Type 1's on board 38
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 27 July 2017
Resolution: Vessel purchase 4 adult jackets
Electrical › Lighting (service) › Outlet Box
Issued 24 July 2017
Resolved
Replace missing light cover in engine room
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 28 August 2017
Resolution: cover replaced in e/r
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 July 2017
Resolved
Ice Maker needs to be hard wired IAW approved plans
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 28 August 2017
Resolution: Ice maker wired IAW plans
Electrical › Lighting (service) › Outlet Box
Issued 24 July 2017
Resolved
Under main cabin sink, mount electrical box and add cover
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 28 August 2017
Resolution: electrical box has been mounted
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 July 2017
Resolved
install guards on exposed alternator belt
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 28 August 2017
Resolution: New gaurds are installed
Lifesaving › Lifebuoys › Serviceable
Issued 24 July 2017
Resolved
Add Retro reflective tape to Ring Bouy
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 28 August 2017
Resolution: New Ring Bouy with tape has been installed
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 July 2017
Resolved
Install approved Nav lights IAW 46 CFR 183.420 2 NM lights.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 28 August 2017
Resolution: New 2nm Nav lights have been installed
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 July 2017
Resolved
Replace Ring Buoy Light Lanyard with approved type.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 28 August 2017
Resolution: New lanyard installed on Bouy Light
Lifesaving › Hand Flares › Expired
Issued 24 July 2017
Resolved
Replace outdated flares and proper quantity
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 27 July 2017
Resolution: Vessel purchased correct amount of flares
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 August 2016
Resolved
Needs to replace with Coast Guard approved kit and ensure items are not expired.
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 7 April 2017
Resolution: O/O purchased new CG approved First Aid Kits
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 1 August 2016
Resolved
Need to have annual Consortium MIS enrollment report and random testing results on board.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2016
Resolved 2 August 2016
Resolution: Recieved fax from P/V MARTINI. All required documentation from Concentra was included: random employee drug screen results, Annual MIS Data Form, and Certificate of Participation in random drug and alcohol testing program, Sept 12, 2014 - Aug 31, 2017.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 1 August 2016
Resolved
Needs to have 02 more lifejackets on board. Reduced passenger count from 42 to 40 until they are onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2016
Resolved 8 August 2016
Resolution: 02 adult lifejackets were bought, marked and stowed on board the vessel.