Documentation record
Registered dimensions (L × B × D)56.0 ft × 16.0 ft × 9.7 ft
Registered tonnagegross 58 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDMR YACHTS INC · ARUNDEL, ME, UNITED STATES · built 1986
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Simplified, Gross Ton
46 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
18 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
12 February 2026
Administrative Inspection · Vessel Attendance · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8310002
7 January 2026
Vessel Attendance · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8291246
13 February 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8079291
7 February 2024
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7855531
11 January 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7849845
14 September 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7791278
9 February 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7634699
16 February 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7397133
19 January 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7382539
9 February 2021
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7137897
10 February 2020
Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6906283
15 January 2020
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6890594
11 February 2019
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6625317
7 February 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6346251
24 January 2018
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6340331
13 February 2017
DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6086056
23 March 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5837549
13 January 2016
Administrative Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5799435
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 February 2024
Resolved
Engine room bilge alarm did not function.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2024
Resolution: Alarm sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 February 2023
Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 September 2023
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 9 February 2021
Resolved
Secure aft Engine Room bulkhead penetration during next Drydock.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 16 February 2022
Resolution: Penetration sealed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 February 2020
Resolved
Properly install smoke detectors in engine room.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2020
Resolved 25 February 2020
Resolution: Smoke detectors installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2020
Resolved
Install double hose clamps on AC, Generator, Port Main, and Sewage.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2020
Resolved 25 February 2020
Resolution: All double hoses were double clamped.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 10 February 2020
Resolved
Prove proper operation of engine room bilge alarm.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2020
Resolved 25 February 2020
Resolution: Tested satisfactory this date.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 February 2020
Resolved
Remove audible bilge alarm bypass
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2020
Resolved 25 February 2020
Resolution: Bypass was removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 February 2020
Resolved
Install proper signage on engine room door.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2020
Resolved 25 February 2020
Resolution: Signage posted on both sides of engine room door.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 13 February 2017
Resolved
Reconfigure the sewage vent line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 3 March 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 February 2017
Resolved
Remove the 110 outlet box and provide a junction box for service.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 3 March 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 February 2017
Resolved
Terminal strip in engine room needs enclosure for protection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 3 March 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 February 2017
Resolved
Upper deck port side hand rail near life floats, reattach railing to house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 3 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 13 February 2017
Resolved
Port midship light fixture globe renew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 3 March 2017
Stability › Weathertight Integrity › General
Issued 13 February 2017
Resolved
Port and STBD aft windows are cracked and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 3 March 2017
Fire Fighting › Fire Main › Valves
Issued 13 February 2017
Resolved
Renew or rebuild the Fire station valve for vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 13 February 2017
Resolution: Vessel rebuilt the valve.
Construction/Loadline › Penetrations › Pipe Flange
Issued 13 February 2017
Resolved
In the vessels Tank room, repair the holes in bulkhead pipe flange to steering room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 3 March 2017
Lifesaving › Lifefloat › Painter
Issued 23 March 2016
Resolved
Renew port and STBD sea painter...
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2016
Resolved 29 March 2016
Resolution: Renewed
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 23 March 2016
Resolved
Install a working HERTZ meter for the generator system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2016
Resolved 29 March 2016
Resolution: installed.