← All vessels
HARBOR BELLE
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Northeast District (CGD-NE) · Other hulls named HARBOR BELLE
HARBOR BELLE is a 1986 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 1986, most recently in January 2010, along with 115 deficiencies and 1 casualty investigation in 2006.
Records from 1986 to 2010. Most recent: inspection, 21 January 2010.
- Built
- 1986
- Last inspected
- 21 January 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 115 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2006
Identity
698494
WC12506
267758
Flag
UNITED STATES
367426180 (licence lapsed)
Maury page id
psix-267758
Inspections, by type
…with no type recorded7
Years with a record
23 calendar years (1986–2010)
The 49 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
32 - Regulatory (Subpart C or D), Net Ton
32 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WCZ5814MMSI 367426180 · expired · voluntarily equipped · granted 24 September 2009, cancelled 8 February 2020
WCI2506MMSI not assigned · cancelled · compulsorily equipped · granted 3 June 1994, cancelled 14 December 2001
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 49
21 January 2010
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3667457
14 October 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3344183
23 July 2007
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3004463
30 April 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2907224
7 June 2006
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2673278
3 April 2006
Re-Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2615527
3 June 2005
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2378172
8 April 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2329181
6 April 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2038352
18 June 2003
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1850192
28 February 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1759597
19 August 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1663242
28 November 2001
COI Inspection · Plan Review "T" Boat · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1478293
21 May 2001
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1068422
16 March 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1406885
11 January 2001
Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 825139
9 January 2001
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1462918
5 August 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 31960
27 January 2000
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 814342
15 December 1999
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1426304
19 November 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1452587
30 June 1999
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1083253
28 December 1998
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 810601
14 April 1998
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 788909
12 December 1997
Excursion Permit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1419857
4 December 1997
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 778100
11 August 1997
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1113313
21 April 1997
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1100192
15 April 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1383531
18 April 1996
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1367733
23 February 1996
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 885292
17 April 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1175235
16 April 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 861863
13 April 1994
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1167517
16 July 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 846509
3 June 1993
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 831821
24 April 1992
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1264773
22 April 1992
Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 947919
7 December 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1223093
6 September 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 911262
2 August 1990
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 908722
8 January 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1211769
22 June 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1346571
18 November 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 894185
7 October 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 889579
22 June 1988
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 897315
14 August 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1031530
16 June 1987
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1316393
16 May 1986
Initial Construction-Excluding Oversight · Initial Certification · Credit Drydock
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 997436
Deficiency record · 115
Engineering › Sea-water System (primary cooling) › Pump
Issued 14 October 2008
Resolved
Raw water pump seal on port side leaking, will contact CG when seal replaced.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 30 April 2007
Resolved
Renew port propeller.
Engineering › Fuel Oil Service System › Piping
Issued 30 April 2007
Resolved
Repair leaking fuel piping IWO union in fuel tank void.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 April 2006
Resolved
Renew first aid kit.
Navigation › Piloting/Steering › Magnetic Compass
Issued 7 April 2006
Resolved
Replace the light in the compass.
Engineering › Bilge Water Management System › Pump
Issued 7 April 2006
Resolved
Provide a portable bilge hand pump.
Engineering › Bilge Water Management System › Not Operational
Issued 7 April 2006
Resolved
Prior to carring passengers, prove proper operation of the bilge system.
Construction/Loadline › Structures › Deck Plating
Issued 3 June 2005
Resolved
Properly repair Hole in Forepeak Void (overhead port area under bench on Foc'sle).
Construction/Loadline › Hull › Hull Plating
Issued 8 April 2005
Resolved
Crop and renew holed main deck forward of hatch to the # 3 void space port side.
Construction/Loadline › Hull › Hull Plating
Issued 8 April 2005
Resolved
Crop and renew holed deck located in the # 2 void space starboard.
Construction/Loadline › Penetrations › Weld
Issued 8 April 2005
Resolved
Weld holed bulkhead between the engine room and the # 5 void space water tank compartment starboard side.
Engineering › Bilge Water Management System › Interface Detector
Issued 8 April 2005
Resolved
Repair high level bilge alarm to engine room prior to carrying passengers.
Construction/Loadline › Penetrations › Pipe Flange
Issued 8 April 2005
Resolved
Replace water inlet pipe to the starboard main engine.
Construction/Loadline › Structures
Issued 6 April 2004
Resolved
Ventilation on the stbd side of the engine room. The vent is wasted around the base of the vent. Vent needs to be removed and the deck cropped and renewed. LEGACY COMPONENT DESC: Ventilators
Construction/Loadline › Structures
Issued 6 April 2004
Resolved
Combing around the port engine hatch is wasted. All must be cropped and renewed. LEGACY COMPONENT DESC: Deck Plating
Construction/Loadline › Hull
Issued 6 April 2004
Resolved
Split seam running from under the generator forward to void # 5. Vessel need s to be drydocked and repair proposal submitted. LEGACY COMPONENT DESC: Bottom Plating
Lifesaving › Lifejacket/PFD (General)
Issued 6 April 2004
Resolved
Vessel is limited to carrying 128 total adults until proper number of PFD are provided. LEGACY COMPONENT DESC: Quantity
Electrical › Electrical Distribution System (service)
Issued 6 April 2004
Resolved
Properly box off or remove the dead end wires in the eng compartment stbd side and in void #5 stbd side. LEGACY COMPONENT DESC: Wiring
Electrical › Lighting (service)
Issued 6 April 2004
Resolved
Place bulb and proper cover on light fixture pt side of the eng compartment. LEGACY COMPONENT DESC: Lighting Fixture
Operations/Management › Drills/Instruction
Issued 6 April 2004
Resolved
Properly place an emergency broadcast placard on the bridge. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 6 April 2004
Resolved
Properly mark upper deck ladder way for max number of passengers allowed. LEGACY COMPONENT DESC: Open Deck Space
Electrical › Electrical Distribution System (service)
Issued 6 April 2004
Resolved
Properly repair the open recepticale box on the upper deck behinfd the pilot house. LEGACY COMPONENT DESC: Junction Box
Operations/Management › Drills/Instruction
Issued 6 April 2004
Resolved
produce traing and bridge log for vessel.
Electrical › Electrical Distribution System (service)
Issued 6 April 2004
Resolved
Place proper lock out bar in distribution panel to isolate ships power from shore power. LEGACY COMPONENT DESC: Distribution Panel Bus
Lifesaving › Lifebuoys
Issued 6 April 2004
Resolved
Properly replace the life ring. LEGACY COMPONENT DESC: Quantity
Engineering
Issued 6 April 2004
Resolved
Vessels Throttles operate backwards!
Pollution Prevention/Response › Prevention Equipment
Issued 6 April 2004
Resolved
Lock out sewage system overboard discharge valve. LEGACY COMPONENT DESC: Sewage System Valve
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 April 2004
Resolved
Place machinery guard on port engine, by belts.
Engineering › Bilge Water Management System
Issued 18 June 2003
Resolved
Prior to carrying passengers relabel bilge system and provide proper diagram.
Engineering › Fuel Oil Service System
Issued 18 June 2003
Resolved
Provide proper fuel shutoff Placard for Emergency fuel shutoff.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 June 2003
Resolved
Repair Forward rail.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 June 2003
Resolved
Repair remote start for Port MDE.
Electrical › Electric Generation Source (service)
Issued 19 March 2003
Resolved
Reroute feeder cable for generator.
Navigation
Issued 19 March 2003
Resolved
Provide new charts for Boston Harbor.
Operations/Management › Drills/Instruction
Issued 19 March 2003
Resolved
Conduct manover board and fire drills in the presence of a Coast Guard Marine Inspector.
Construction/Loadline › Hull
Issued 19 March 2003
Resolved
Prior to operating, vessel must complete a credit drydock examination.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 January 2002
Resolved
Provide valid FCC safety Certificate.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 14 January 2002
Resolved
Properly pipe sewage system to allow pumping the holding tank.
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 January 2002
Resolved
Provide 12 aadult and 01 childs lifejacket. LEGACY COMPONENT DESC: Quantity
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 January 2002
Resolved
Provide machinery guards for both MDE's
Electrical › Lighting (service) › Conductor
Issued 14 January 2002
Resolved
Remove all temporary wiring and extension cords in engineroom and bar void spaces
Electrical › Electrical Distribution System (service) › Conductor
Issued 14 January 2002
Resolved
Remove or terminate in junction box all dead ended wires near battery charger.
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 January 2002
Resolved
Make proper repairs to bilge alarm system.
Construction/Loadline
Issued 16 March 2001
Resolved
BILGE HIGH LEVEL ALARMS NOT WORKING.
Engineering
Issued 16 March 2001
Resolved
Unknown Component - Unknown Cause/Condition
Engineering
Issued 16 March 2001
Resolved
Unknown Component - Unknown Cause/Condition
Electrical
Issued 16 March 2001
Resolved
Unknown Component - Unknown Cause/Condition
Engineering
Issued 16 March 2001
Resolved
Unknown Component - Unknown Cause/Condition
Lifesaving
Issued 16 March 2001
Resolved
Unknown Component - Unknown Cause/Condition
Navigation
Issued 16 March 2001
Resolved
Unknown Component - Unknown Cause/Condition
Documentation
Issued 19 November 1999
Resolved
PROPERLY POST THE APPROPRIATE POLLUTION PREVENTION PLACARD IN THE MACHINERYSPACE.
Documentation
Issued 19 November 1999
Resolved
PROVE COMPLIANCE WITH ENROLLMENT IN AN APPROVED DRUG TESTING PROGRAM.
Fire Fighting
Issued 19 November 1999
Resolved
PROVE PROPER OPERATION OF THE UPPER DECK FIRE HOSE.
Construction/Loadline
Issued 19 November 1999
Resolved
MAKE PERMENANT APPROPRIATE REPAIRS TO THE BOLT HOLES PORT AND STARBOARD SIDE IN VARIOUS COMPARTMENTS. TO BE COMPLETED AT NEXT CREDIT DRYDOCK EXAM.
Fire Fighting
Issued 19 November 1999
Resolved
PLACE A FIRE EXTINGUISHER SIGN AT STARBOARD SIDE AFT FIRE EXTINGUISHER.
Electrical
Issued 19 November 1999
Resolved
PROVIDE A LIGHT GLOBE AND COVER FOR THE LIGHT IN THE MACHINERY SPACE.
Documentation
Issued 19 November 1999
Resolved
PLACE DOCUMENTATION STICKER ON THE DOCUMENT.
Unknown
Issued 19 November 1999
Resolved
PROPERLY LABEL THE UPPER DECK WITH THE MAXIMUM PASSENGERS ALLOWED.
Lifesaving
Issued 28 December 1998
Resolved
PRIOR TO OPERATING CONDUCT FIRE AND BOAT DRILL.
Electrical
Issued 28 December 1998
Resolved
PROVIDE GUARD FOR SHIPS SERVICE GENERATOR.
Electrical
Issued 28 December 1998
Resolved
SECURE AND FABRICATE PROPER BOXES FOR ALL BATTERIES LOCATED IN THE ENGINE ROOM.
Electrical
Issued 28 December 1998
Resolved
RENEW KINKED EXHAUST HOSE FOR SHIPS SERVICE GENERATOR.
Electrical
Issued 28 December 1998
Resolved
REMOVE CABLE SPLICE TO AC PUMP IN BAR STORAGE VOID SPACE.
Engineering
Issued 28 December 1998
Resolved
RENEW FUEL LINES ON PORT MAIN PROPULION ENGINE.
Accommodation/Occupational Safety
Issued 28 December 1998
Resolved
REPLACE PVC PIPING WITH METALLIC PIPING FROM THE SEA STRAINER TO THE SUCTION SIDE OF THE AC PUMP.
Lifesaving
Issued 15 April 1997
Resolved
RELOCATE RING BUOY TO MORE ACCESSIBLE LOCATION.
Electrical
Issued 15 April 1997
Resolved
INSTALL BELTGUARD ON GENERATOR.
Lifesaving
Issued 15 April 1997
Resolved
CONDUCT MAN OVERBOARD DRILL AND UNDERWAY OPERATIONAL TEST WITH CAPTAIN AND SENIOR DECKHAND.
Construction/Loadline
Issued 15 April 1997
Resolved
MAKE PROPER REPAIRS TO FOREPEAK AND ENGINEROOM HATCH COVERS AND PROVE WATER/WEATHER TIGHT.
Navigation
Issued 15 April 1997
Resolved
REMORE 50LB CO2 CYLINDER FOR HORN SYSTEM OR HAVE PROPERLY SERVICED AND INSTALLED._x001C_
Documentation
Issued 18 April 1996
Resolved
OBTAIN COPY OF TIDE TABLES.
Documentation
Issued 18 April 1996
Resolved
PROVIDE PROOF OF RENEWAL OF CERTIFICATE OF DOCUMENTATION.
Construction/Loadline
Issued 18 April 1996
Resolved
INSTALL VALVE FOR A/C INTAKE THRU HULL.
Documentation
Issued 18 April 1996
Resolved
PROVIDE PROOF OF FCC OPERATOR'S LICENSE.
Documentation
Issued 18 April 1996
Resolved
MAKE CORRECTIONS TO CHART USING NOTICE TO MARINERS.
Engineering
Issued 18 April 1996
Resolved
REPLACE MACHINERY GUARD ON PORT ENGINE.
Lifesaving
Issued 18 April 1996
Resolved
PLACE RETROREFLECTIVE TAPE ON RING BUOY.
Construction/Loadline
Issued 18 April 1996
Resolved
PUMP WATER FROM FOREPEAK.
Documentation
Issued 18 April 1996
Resolved
OBTAIN AND POST EMERGENCY BROADCAST PLACARD NEAR RADIO.
Lifesaving
Issued 18 April 1996
Resolved
POST OR MAKE AVAILABLE DONNING INSTRUCTION PLACARD FOR ALL TYPES PFD'S FOUND ON BOARD.
Electrical
Issued 18 April 1996
Resolved
REPLACE SWITCH COVER ON ELECTRICAL BOX IN PILOTHOUSE.
Lifesaving
Issued 18 April 1996
Resolved
OBTAIN 3 RED AND 3 ORANGE DISTRESS SIGNALS.
Construction/Loadline
Issued 18 April 1996
Resolved
MAKE TEMPORARY REPAIRS TO PREVIOUS REPAIR OF TRANSOM, PORT SIDE, AS DISCUSSED. (TO COMPLETE PERMANENT REPAIRS NEXT DRYDOCK.)
Construction/Loadline
Issued 18 April 1996
Resolved
PROPERLY WELD PIPING FOR THRU HULL OF A/C INTAKE.
Documentation
Issued 18 April 1996
Resolved
PROVIDE PROOF OF ENROLLMENT IN A DRUG PROGRAM.
Electrical
Issued 17 April 1995
Resolved
INSTALL PROPER BATTERY BOX FOR GEN SET.
Lifesaving
Issued 17 April 1995
Resolved
WATERLIGHT BATTERY WEAK
Electrical
Issued 17 April 1995
Resolved
install proper battery box bracket on port side.
Electrical
Issued 17 April 1995
Resolved
improper battey connections
Engineering
Issued 3 June 1993
Resolved
REPLACE MISSING HOLD DOWN BOLT ON PORT SIDE ENGINE.
Documentation
Issued 3 June 1993
Resolved
PROVIDE COPY OF FCC RADIO OPERATOR'S LICENSE.
Electrical
Issued 3 June 1993
Resolved
PROVIDE BATTERY BOX COVER FOR STARBOARD ENGINE_x001C_
Electrical
Issued 3 June 1993
Resolved
PROVIDE BATTERY BOX FOR GENERATOR'S BATTERY_x001C_
Engineering
Issued 3 June 1993
Resolved
PROVIDE BELT GUARDS ON PORT AND STBD ENGINES_x001C_
Unknown
Issued 3 June 1993
Resolved
PROVIDE CHECK VALVE ON POTABLE WATER TANK VENT
Documentation
Issued 22 April 1992
Resolved
PROVIDE FCC SAFETY CERTIFICATE ONBOARD. VESSEL RESTRICTED TO OPERATIONS NOTMORE THAN 1000 FEET FROM SHORE UNTIL CORRECTED.
Lifesaving
Issued 7 December 1990
Resolved
MARK ALL PFDS AND RING BOUYS WITH PROPER VESSEL NAME.
Unknown
Issued 2 August 1990
Resolved
PROVIDE AND INSTALL LABEL FOR REMOTE FUEL SHUT-OFF, OUTSIDE OF COMPARTMENT.
Lifesaving
Issued 2 August 1990
Resolved
PROVIDE ONE RING BUOY TO REPLACE TORN ONE, PRIOR TO CARRYING PASSENGERS.
Fire Fighting
Issued 22 June 1988
Resolved
PROVIDE ONE HAND OPERATED PORTABLE BILGE/FIRE PUMP HAVING A CAPACITY OF AT LEAST 5 GALLONS PER MINUTE. THE PUMP SHALL BE EQUIPPED WITH SUCTION AND DISCHARGE HOSE SUITABLE FOR USE IN FIRE FIGHTING.
Fire Fighting
Issued 22 June 1988
Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Fire Fighting
Issued 22 June 1988
Resolved
PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER FOR UPPER DECK.
Lifesaving
Issued 22 June 1988
Resolved
PROVIDE 6 RED FLARES AND 6 ORANGE FLARES OR 12 CONBINATION FLARES ALONG WITH A WATERTIGHT CONTAINER.
Lifesaving
Issued 22 June 1988
Resolved
LIFE PRESERVERS FOR CHILDREN SHALL BE STOWED SEPARTELY FROM THE ADULT PFD'SAND THE CONTAINER MARKED AS PER 180.25-15
Lifesaving
Issued 22 June 1988
Resolved
ALL LIFE PRESERVERS SHALL BE MARKED WITH THE VESSEL'S NAME.
Lifesaving
Issued 22 June 1988
Resolved
PROVIDE ONE ADULT AND ONE CHILD PFD. PASSENGER CAPACITY REDUCED TO 149 UNTIL PFD'S ARE ON BOARD.
Construction/Loadline
Issued 22 June 1988
Resolved
SEAL 6" TUBE THAT RUNS FROM ENGINEROOM TO COMPARTMENT A.
Construction/Loadline
Issued 22 June 1988
Resolved
REMOVE THE "BY ORDER OF USCG" IN THE "NO SMOKING BY ORDER OF USCG" SIGNS POSTED OUTSIDE THE LOUNGE AREA.
Construction/Loadline
Issued 22 June 1988
Resolved
SECURE OLD ENGINEROOM VENT TO PREVENT DOWNFLOODING.
Documentation
Issued 22 June 1988
Resolved
PROVIDE FCC CERTIFICATE
Engineering
Issued 16 June 1987
Resolved
PROVIDE AND INSTALL FLAME SCREEN (30 X 30 MESH CORROSION RESISTANT WIRE) FOR FUEL TANK VENT.
Fire Fighting
Issued 16 June 1987
Resolved
PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER FOR THE UPPER DECK.
Lifesaving
Issued 16 June 1987
Resolved
PROVIDE ONE ADULT AND ONE CHILD PFD. PASSENGER CAPACITY REDUCED TO 149 UNTIL LIFE PRESERVERS ARE ON BOARD.
Unknown
Issued 16 June 1987
Resolved
SEAL 6 INCH TUBE THAT RUNS FROM ENGINE ROOM TO COMPARTMENT "A"(UNDER BAR).
Unknown
Issued 16 June 1987
Resolved
REMOVE LEAD PELLETS FROM ENGINE ROOM.
Casualty record · 1
7 June 2006Routine · role: Involved in a Marine Casualty · at NORTHERN AVENUE BRIDGE · activity 2673278
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.