ISLAND GIRL

ISLAND GIRL is a 1986 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2016, most recently in May 2026, along with 29 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2026. Most recent: inspection, 21 May 2026.

Built
1986
Last inspected
21 May 2026
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDG 4666
267760
Flag
UNITED STATES
Maury page id
psix-267760

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)63.0 ft × 16.0 ft × 5.5 ft
Registered tonnagegross 85 / net 68
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSKIPPERLINER INDUSTRIES · LACROSSE, WI, UNITED STATES · built 1986
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAKE TEXOMA, TX
Trade endorsementsRecreational
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it85 - Simplified, Gross Ton
68 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

21 May 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8380860
24 March 2025 Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8098630
12 February 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7865645
11 January 2023 COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7620310
8 December 2021 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7368685
2 March 2021 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7152683
14 February 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6909113
24 April 2019 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6670898
31 January 2018 Internal Structural Exam · COI Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6305265
20 July 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5953485

Deficiency record · 29

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 May 2026 No resolution recorded
The provisions of this part shall apply to the electrical installations on all vessel contracted for on all vessels contracted for on or after June 1, 1958. Vessels generator found inoperable and non repairable. New generator schematics will need to be submitted to the USCG Marine Safety Center and Sector Houston/Galveston for review prior to installation.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 April 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Marine Inspector discovered port main diesel engine inoperable. Vessel restricted from carrying passengers until port main diesel engine is repaired to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 182.01-5 17 C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2025
Resolution: Verified main engine operational.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 April 2025 Resolved
The intent of this part is to insure that the scantling's, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Marine inspector discovered complete steel wastage of forward bow compartment access and surrounding area. Vessel must affect repairs to the satisfaction of a Coast Guard Marine Inspector prior to carrying passengers. 46 CFR 177.01-5 17 C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2025
Resolution: Verified steel repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 April 2025 Resolved
The intent of this part is to insure that the scantling's, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Marine inspector discovered pinhole in forward collision bulkhead and aft bulkhead of compartment #2. Also, separation between side shell and overhead deck in port and stbd aft upper corners of compartment #2, and overhead of compartment #5 forward of port waste tank. Vessel must affect repairs to the satisfaction of a Coast Guard Marine Inspector prior to carrying passengers. 46 CFR 177.01-5 701 C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2026
Resolution: Received verification of repair. All sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 1 April 2025 Resolved
The intent of this part is to insure that the scantling's, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. 46 CFR 177.01-5 701 C Marine Inspector discovered an approximate 12" x 4" hole in overhead deck of compartment #2, starboard side. Vessel must affect repairs to the satisfaction of a Coast Guard Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2026
Resolution: Reeived verification of repair. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 1 April 2025 Resolved
At each initial and subsequent inspection for certification and reinspection the marine inspector shall examine the passenger and crew quarters,toilet, and washing spaces, galleys,serving pantries lockers,etc.,to determine that they are serviceable and in a sanitary condition. Vessel shall repair or isolate stbd sewage tank to the satisfaction of a Coast Guard Marine Inspector. Vessel shall also sanitize bilge and surrounding area of leaking sewage tank to the satisfaction of a Coast Guard Marine Inspector. Marine Inspectors discovered active leak in stbd sewage tank and multiple holes and wastage on tank shell. 46 CFR 176.25-45 50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 January 2026
Resolution: Starboard sewage tank isolated, not in use. All sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 1 April 2025 Resolved
The intent of this part is to insure that the scantling's, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Marine Inspector discovered multiple metallic screws penetrating the stbd side shell and entering compartment #5. Vessel shall repair to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 177.01-5 50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 January 2026
Resolution: Verified repairs. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2025 Resolved
Vessels not limited to daytime operation shall be provided, with an approved water light. Marine inspector discovered ring life buoy water light located on upper deck inoperable. Replace repair light to satisfaction of a Coast Guard Marine inspector. 46 CFR 180.30-5 50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 January 2026
Resolution: Verified new life ring installed. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 March 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel owner reported malfunction of both on board generators. Vessel restricted from carrying passengers until generators are repaired to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 182.01-5 701 C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2026
Resolution: Port generator repaird and working properly. stbd gen still awaiting parts. Two generators not required for this vessel. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2025 Resolved
Unless a splice is made by an insulated pressure wire connector listed by Underwriters' Laboratories, In., it shall be thoroughly soldered, taped first with rubber and then with friction tape, or the soldered joint shall be otherwise protected as to provide an insulation the same as that of the conductors joined. Vessel shall replace all screw type wire connectors with crimp type connectors to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 183.05-50 50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 January 2026
Resolution: Crimp type connectors installed. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 February 2024 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. MI discovered incorrect number identification of lifejacket stowage location. Re-label location to correct number of stowed lifejackets. 46 CFR 185.604(f) 16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 12 February 2024
Resolution: Correct numbering attached to stowage area.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2024 Resolved
Propulsion machinery shall be suitable in type and design...capable Of operating at constant marine load under such requirements without exceeding its designed limitations. MI discovered a leak in the outboard engine thru hull seal. Repair seal and stop leak to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 182.05-1 16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 1 May 2024
Resolution: Leak sealed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 February 2024 Resolved
Garden hose shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent metal. Marine Inspector discovered wrong type hose nozzle attached to garden hose. Replace nozzle with appropriate type material nozzle. 46 CFR 181.15-10(e) 16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 1 May 2024
Resolution: New hose and nozzle on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 February 2024 Resolved
The master of each vessel subject to this subpart shall ensure that suitable public announcements, instructive placards or both are provided for proper method of donning and adjusting life preservers of the type(s) carried on the vessel. MI discovered missing lifejacket donning instructions on board vessel. Provide lifejacket donning placard or instructions. 46 CFR 185.25(d) 16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 26 February 2024
Resolution: Donning placards posted on vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 February 2024 Resolved
Lighting fixtures shall be constructed in accordance with the requirements of Underwriters Laboratories, Inc. Standard for Marine Type Electric Lighting Fixtures, Subject 595. MI discovered light fixture on starboard aft deck filled with water and debris. Repair/replace fixture to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 183.10-20(l) 16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 26 February 2024
Resolution: Light fixture repaired and re-sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2024 Resolved
All wiring shall be run as high as practicable above bilges. MI discovered aft bilge alarm wiring submerged in water in engine space. Secure wiring as high above bilge as possible and out of water. 46 CFR 183.10-20(d) 16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 26 February 2024
Resolution: Wires removed from water and secured above bilge.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 May 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. MI observed 5 of 6 bilge alarms with inoperable audible alarm. Alarm for compartment #4 had an inoperable visual and audible alarm. Prove proper operation of bilge alarms prior to carriage of passengers to the satisfaction of the Coast Guard Marine Inspector. 46 CFR 182.530(a) 701(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2022
Resolution: Replaced alarm panal. Test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 May 2022 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. MI observed cooling water leaks on port and starboard main propulsion engines. Prove proper operation of main propulsion engines prior to the carriage of passengers to the satisfaction of the Coast Guard Marine Inspector. 46 CFR 182.05-1(a) 701(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2022
Resolution: Repaired coolant leak, replaced coolant reservoir.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 May 2022 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. MI observed exhaust leak on the Ship Service Diesel Generator (SSDG). Prove proper operation of SSDG prior to carriage of passengers to the satisfaction of the Coast Guard Marine Inspector. 46 CFR 182.10-1(a) 701(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2022
Resolution: Repaired exhaust leak.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2022 Resolved
Ignition wiring as supplied or recommended by engine manufacturers is generally acceptable. MI observed welding cable used in place of marine grade cable on port engine. Additionally, MI observed damage to cable insulation. Replace cable with marine grade ground cable to the satisfaction of the Coast Guard Marine Inspector. 46 CFR 183.05-40(a) 50(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 14 June 2022
Resolution: New marine grade cable installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2022 Resolved
Each life jacket carried on board the vessel must be marked in accordance with § 185.604 of this chapter. MI observed retroreflective material on 02 child life jackets to be degraded. Replace 02 life jackets to the satisfaction of the Coast Guard Marine Inspector. 46 CFR 180.71(e) 50(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 19 May 2022
Resolution: Purchased 02 child size life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2021 Resolved
S. If garden hose is used, it shall be of a good commercial grade constructed of an inner rubber tube, plies of braided cotton reinforcement and in outer rubber cover or of equivalent material, and shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent metal. MI observed nozzle on fire hose to be degraded. Replace nozzle with a commercial garden hose nozzle of good grade bronze or equivalent metal to the satisfaction of the Coast Guard Marine Inspector. 46 CFR 181.15-10(e) 50(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 19 May 2022
Resolution: Installed new fire hose and hose nozzle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 February 2020 Resolved
Visual indicator must be provided at the operating station to indicate bilge pump is operating. indicating light for the #2 bilge was inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 February 2020 Resolved
Machinery and equipment installed on vessel must be suitable for the vessel and its operation. Port engine would not start.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 February 2020 Resolved
First Aid kit was invalid. Item in the kit were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 February 2020 Resolved
Portable watertight containers for distress flares and smoke signals shall be bright in color, watertight and labeled. Container was not watertight, bright in color, or labeled IAW regulations. Container was a black fishing tackle box and not labeled Distress Signals.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2020 Resolved
All machinery must be maintained in such a manner as to afford adequate protection from machinery failure. A/C raw water cooling hoses are dry rotted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 May 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 April 2019 Resolved
Fire pump pressure gauge not installed.
Action required: 10 - Deficiency Rectified
Due 24 April 2019
Resolved 24 April 2019
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 24 April 2019 Resolved
Provide garbage plan.
Action required: 10 - Deficiency Rectified
Due 24 April 2019
Resolved 24 April 2019