Records from 1986 to 2026. Most recent: inspection, 21 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 65
21 May 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8380860
24 March 2025
Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8098630
12 February 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7865645
11 January 2023
COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7620310
8 December 2021
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7368685
2 March 2021
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7152683
14 February 2020
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6909113
24 April 2019
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6670898
31 January 2018
Internal Structural Exam · COI Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6305265
20 July 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5953485
13 October 2015
Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5741032
1 June 2012
Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4333305
3 December 2010
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3903436
23 November 2010
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3897728
22 November 2010
Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3896221
22 October 2010
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3875094
14 September 2010
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3849610
6 July 2009
Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3525696
29 July 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3282896
3 July 2008
Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3254756
22 May 2007
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2937105
30 May 2006
Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2688354
14 April 2006
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2624917
21 September 2005
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2498076
12 April 2005
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2332248
24 May 2004
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2085478
8 April 2004
Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2040662
22 April 2003
Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1778913
14 August 2002
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1661610
10 April 2002
COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1602134
25 April 2001
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1452818
8 May 2000
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1049667
7 March 2000
Examination of Repairs
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1423325
14 April 1999
COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1418594
10 March 1999
Examination of Repairs · Hull Examination
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1395267
20 August 1998
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 800558
16 July 1998
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 794997
8 October 1997
Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1110697
18 July 1997
Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1115701
18 July 1997
Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1117717
20 March 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1392630
22 January 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1099693
15 June 1996
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1083474
24 May 1996
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1080521
13 December 1995
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 875455
18 May 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1414470
26 April 1995
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1438303
1 August 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 863236
2 June 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1170818
1 September 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 843255
12 May 1993
COI Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 833216
8 September 1992
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 228266
20 August 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 954343
21 June 1991
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 912619
1 May 1990
Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1238112
13 June 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 893149
26 July 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1038116
16 June 1988
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1206820
1 July 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1318714
28 May 1987
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1334810
2 October 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1005645
11 September 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1001580
7 August 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1295130
19 June 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1305750
30 May 1986
Initial Certification · Credit Drydock · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 989639
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 May 2026
No resolution recorded
The provisions of this part shall apply to the electrical installations on all vessel contracted for on all vessels contracted for on or after June 1, 1958.
Vessels generator found inoperable and non repairable. New generator schematics will need to be submitted to the USCG Marine Safety Center and Sector Houston/Galveston for review prior to installation.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 April 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery
failure, and personnel injury.
Marine Inspector discovered port main diesel engine inoperable.
Vessel restricted from carrying passengers until port main diesel engine is repaired to the satisfaction of a Coast Guard Marine Inspector.
46 CFR 182.01-5
17 C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2025
Resolution: Verified main engine operational.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 April 2025
Resolved
The intent of this part is to insure that the scantling's, material, fastenings, workmanship and arrangement of each vessel are such as to provide for
safe operation in accordance with the terms of its certificate of inspection.
Marine inspector discovered complete steel wastage of forward bow compartment access and surrounding area.
Vessel must affect repairs to the satisfaction of a Coast Guard Marine Inspector prior to carrying passengers.
46 CFR 177.01-5
17 C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2025
Resolution: Verified steel repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 April 2025
Resolved
The intent of this part is to insure that the scantling's, material, fastenings, workmanship and arrangement of each vessel are such as to provide for
safe operation in accordance with the terms of its certificate of inspection.
Marine inspector discovered pinhole in forward collision bulkhead and aft bulkhead of compartment #2. Also, separation between side shell and overhead deck in port and stbd aft upper corners of compartment #2, and overhead of compartment #5 forward of port waste tank.
Vessel must affect repairs to the satisfaction of a Coast Guard Marine Inspector prior to carrying passengers.
46 CFR 177.01-5
701 C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2026
Resolution: Received verification of repair. All sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 1 April 2025
Resolved
The intent of this part is to insure that the scantling's, material, fastenings, workmanship and arrangement of each vessel are such as to provide for
safe operation in accordance with the terms of its certificate of inspection.
46 CFR 177.01-5
701 C
Marine Inspector discovered an approximate 12" x 4" hole in overhead deck of compartment #2, starboard side.
Vessel must affect repairs to the satisfaction of a Coast Guard Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2026
Resolution: Reeived verification of repair. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 1 April 2025
Resolved
At each initial and subsequent inspection for certification and reinspection the marine inspector shall examine the passenger and crew quarters,toilet, and washing spaces, galleys,serving pantries lockers,etc.,to determine that they are serviceable and in a sanitary condition.
Vessel shall repair or isolate stbd sewage tank to the satisfaction of a Coast Guard Marine Inspector.
Vessel shall also sanitize bilge and surrounding area of leaking sewage tank to the satisfaction of a Coast Guard Marine Inspector.
Marine Inspectors discovered active leak in stbd sewage tank and multiple holes and wastage on tank shell.
46 CFR 176.25-45
50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 January 2026
Resolution: Starboard sewage tank isolated, not in use. All sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 1 April 2025
Resolved
The intent of this part is to insure that the scantling's, material, fastenings, workmanship and arrangement of each vessel are such as to provide for
safe operation in accordance with the terms of its certificate of inspection.
Marine Inspector discovered multiple metallic screws penetrating the stbd side shell and entering compartment #5.
Vessel shall repair to the satisfaction of a Coast Guard Marine Inspector.
46 CFR 177.01-5
50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 January 2026
Resolution: Verified repairs. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2025
Resolved
Vessels not limited to daytime operation shall be provided, with an approved water light.
Marine inspector discovered ring life buoy water light located on upper deck inoperable.
Replace repair light to satisfaction of a Coast Guard Marine inspector.
46 CFR 180.30-5
50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 January 2026
Resolution: Verified new life ring installed. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 March 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery
failure, and personnel injury.
Vessel owner reported malfunction of both on board generators.
Vessel restricted from carrying passengers until generators are repaired to the satisfaction of a Coast Guard Marine Inspector.
46 CFR 182.01-5
701 C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2026
Resolution: Port generator repaird and working properly. stbd gen still awaiting parts. Two generators not required for this vessel. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2025
Resolved
Unless a splice is made by an insulated pressure wire connector listed by Underwriters' Laboratories, In., it
shall be thoroughly soldered, taped first with rubber and then with friction tape, or the soldered joint shall be otherwise protected as to provide an insulation
the same as that of the conductors joined.
Vessel shall replace all screw type wire connectors with crimp type connectors to the satisfaction of a Coast Guard Marine Inspector.
46 CFR 183.05-50
50 C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 January 2026
Resolution: Crimp type connectors installed. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 February 2024
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits.
MI discovered incorrect number identification of lifejacket stowage location.
Re-label location to correct number of stowed lifejackets.
46 CFR 185.604(f)
16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 12 February 2024
Resolution: Correct numbering attached to stowage area.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2024
Resolved
Propulsion machinery shall be suitable in type and design...capable Of operating at constant marine load under such requirements without exceeding its designed
limitations.
MI discovered a leak in the outboard engine thru hull seal.
Repair seal and stop leak to the satisfaction of a Coast Guard Marine Inspector.
46 CFR 182.05-1
16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 1 May 2024
Resolution: Leak sealed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 February 2024
Resolved
Garden hose shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent metal.
Marine Inspector discovered wrong type hose nozzle attached to garden hose.
Replace nozzle with appropriate type material nozzle.
46 CFR 181.15-10(e)
16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 1 May 2024
Resolution: New hose and nozzle on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 February 2024
Resolved
The master of each vessel subject to this subpart shall ensure that suitable public announcements, instructive placards or both are provided for proper method of donning and adjusting life preservers of the type(s)
carried on the vessel.
MI discovered missing lifejacket donning instructions on board vessel.
Provide lifejacket donning placard or instructions.
46 CFR 185.25(d)
16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 26 February 2024
Resolution: Donning placards posted on vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 February 2024
Resolved
Lighting fixtures shall be constructed in accordance with the requirements of Underwriters Laboratories,
Inc. Standard for Marine Type Electric Lighting Fixtures, Subject 595.
MI discovered light fixture on starboard aft deck filled with water and debris.
Repair/replace fixture to the satisfaction of a Coast Guard Marine Inspector.
46 CFR 183.10-20(l)
16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 26 February 2024
Resolution: Light fixture repaired and re-sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2024
Resolved
All wiring shall be run as high as practicable above bilges.
MI discovered aft bilge alarm wiring submerged in water in engine space.
Secure wiring as high above bilge as possible and out of water.
46 CFR 183.10-20(d)
16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2024
Resolved 26 February 2024
Resolution: Wires removed from water and secured above bilge.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 May 2022
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
MI observed 5 of 6 bilge alarms with inoperable audible alarm. Alarm for compartment #4 had an inoperable visual and audible alarm. Prove proper operation of bilge alarms prior to carriage of passengers to the satisfaction of the Coast Guard Marine Inspector.
46 CFR 182.530(a)
701(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2022
Resolution: Replaced alarm panal. Test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 May 2022
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
MI observed cooling water leaks on port and starboard main propulsion engines. Prove proper operation of main propulsion engines prior to the carriage of passengers to the satisfaction of the Coast Guard Marine Inspector.
46 CFR 182.05-1(a)
701(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2022
Resolution: Repaired coolant leak, replaced coolant reservoir.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 May 2022
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended.
MI observed exhaust leak on the Ship Service Diesel Generator (SSDG). Prove proper operation of SSDG prior to carriage of passengers to the satisfaction of the Coast Guard Marine Inspector.
46 CFR 182.10-1(a)
701(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2022
Resolution: Repaired exhaust leak.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2022
Resolved
Ignition wiring as supplied or recommended by engine manufacturers is generally acceptable.
MI observed welding cable used in place of marine grade cable on port engine. Additionally, MI observed damage to cable insulation. Replace cable with marine grade ground cable to the satisfaction of the Coast Guard Marine Inspector.
46 CFR 183.05-40(a)
50(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 14 June 2022
Resolution: New marine grade cable installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2022
Resolved
Each life jacket carried on board the vessel must be marked in accordance with § 185.604 of this chapter.
MI observed retroreflective material on 02 child life jackets to be degraded. Replace 02 life jackets to the satisfaction of the Coast Guard Marine Inspector.
46 CFR 180.71(e)
50(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 19 May 2022
Resolution: Purchased 02 child size life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2021
Resolved
S. If garden hose is used, it shall be of a good commercial grade constructed of an inner rubber tube, plies of braided cotton reinforcement and in outer rubber cover or of equivalent material, and shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent metal.
MI observed nozzle on fire hose to be degraded. Replace nozzle with a commercial garden hose nozzle of good grade bronze or equivalent metal to the satisfaction of the Coast Guard Marine Inspector.
46 CFR 181.15-10(e)
50(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2022
Resolved 19 May 2022
Resolution: Installed new fire hose and hose nozzle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 February 2020
Resolved
Visual indicator must be provided at the operating station to indicate bilge pump is operating. indicating light for the #2 bilge was inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 February 2020
Resolved
Machinery and equipment installed on vessel must be suitable for the vessel and its operation. Port engine would not start.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 February 2020
Resolved
First Aid kit was invalid. Item in the kit were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 February 2020
Resolved
Portable watertight containers for distress flares and smoke signals shall be bright in color, watertight and labeled. Container was not watertight, bright in color, or labeled IAW regulations. Container was a black fishing tackle box and not labeled Distress Signals.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2020
Resolved
All machinery must be maintained in such a manner as to afford adequate protection from machinery failure. A/C raw water cooling hoses are dry rotted.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 May 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 April 2019
Resolved
Fire pump pressure gauge not installed.
Action required: 10 - Deficiency Rectified
Due 24 April 2019
Resolved 24 April 2019
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 24 April 2019
Resolved
Provide garbage plan.
Action required: 10 - Deficiency Rectified
Due 24 April 2019
Resolved 24 April 2019
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 10 July 2012
Resolved
Make repairs to both engines to resolve overheat problem.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2012
Resolution: Cooling system flushed. Received written verification that both engines are fully operational.
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 June 2012
Resolved
Bilge high level alarms in compartments #4 and #6 inop.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2012
Resolution: Alarms repaired. Received written notification that bilge high level alarms are operational.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 June 2012
Resolved
Post COI and stability letters.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 July 2012
Resolution: Documents posted.
Documentation › Certificates/Documents › FCC SSL
Issued 1 June 2012
Resolved
Have onboard FCC Station License and FCC Safety Certificate.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 17 July 2012
Resolution: Vessel exempt from FCC requirements.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 1 June 2012
Resolved
Post emergency instructions.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 July 2012
Resolution: Posted.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 June 2012
Resolved
Post emergency broadcast placard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 July 2012
Resolution: Posted.
Communications › Public Address System › Loudspeaker
Issued 1 June 2012
Resolved
Make public address system operational.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Received written verification from rep that system is operational.
Documentation › Markings/Placards › Capacity Marking
Issued 1 June 2012
Resolved
Mark upper deck for 28 passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Received written verification from rep that upper deck is marked.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 June 2012
Resolved
Install reflective tape to all lifebuoys.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Received written verification from rep that tape applied.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 June 2012
Resolved
One life buoy requires a 60 ft life line IAW 46 CFR 180.70(c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 July 2012
Resolution: Lifeline installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 June 2012
Resolved
First aid kit must contain items listed in 46 CFR 160.041 and not be expired.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Received written verification that first aid kit properly assembled.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 June 2012
Resolved
Mark stowage of child lifejackets with actual number.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Received written verification from vessel rep that stowage correctly marked.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 1 June 2012
Resolved
Replace fuel filter line to port engine.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Received written verification from vessel rep that line is replaced.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 1 June 2012
Resolved
Replace water pump hose to port generator.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Received written verification from vessel rep that hose is replaced.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 1 June 2012
Resolved
Replace heat exchanger hose to stbd generator.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Received written verification from vessel rep that hose is replaced.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 1 June 2012
Resolved
Repair leaks to marine sanitation device system at male urinal piping and PVC wastewater manifold.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Received written verification that piping repaired.
Engineering › Bilge Water Management System › Pump
Issued 1 June 2012
Resolved
Repair electric submersible bilge pump float switches in compartments #6 and #2.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 1 August 2012
Resolution: Received written verification from vessel rep that float switches repaired/replaced.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 1 June 2012
Resolved
Label all switches and indicators at helm
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 October 2012
Resolved 29 May 2013
Resolution: Cleared by pics sent by e-mail.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 1 June 2012
Resolved
Provide name plates for both generators indicating the maker's name, rating in volts and amps.- Prior to next annual exam.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 October 2013
Resolved 27 June 2013
Resolution: Plates installed as req''d.
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 June 2012
Resolved
Post lifejacket donning placards.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 July 2012
Resolution: Posted.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 October 2010
Resolved
Install battery with ring buoy water light IAW 46 CFR 180.70. There was no battery in the ring buoy water light. Vessel restricted to carry passengers for hire during day light hours only until corrected.
Due 22 November 2010
Resolved 22 November 2010
Resolution: Recd email dated 21Nov10 from [name withheld] attesting to purchase of new water light battery.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 October 2010
Resolved
Renew expired items within the first aid kit IAW 46 CFR 184.710 & 46 CFR 160.041
Due 22 November 2010
Resolved 22 November 2010
Resolution: Recd email dated 21Nov10 from [name withheld] attesting to purchase of new first aid kit.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 October 2010
Resolved
Renew expired COD IAW 46 CFR 67.7 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 November 2010
Resolved 7 May 2012
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 October 2010
Resolved
Adult life jacket stowage not marked properly. The stowage locations are marked 25, 45, 12 & 16 to total 98; the total should be 100 or more. Total actually onboard is sat. Remark IAW 46 CFR 180.78
Due 22 November 2010
Resolved 22 November 2010
Resolution: Recd email dated 21Nov10 from [name withheld] attesting to purchase of new stickers which will be applied during warmer months (currently temp is too cold for stickers to stick).
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 22 October 2010
Resolved
Make proper repairs to port engine and generator to correct injector fuel leak IAW 46 CFR 176.25-50 (old T)
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 November 2010
Resolved 22 November 2010
Resolution: Rec''d email dated 21Nov10 from [name withheld] attesting to satisfactory repair of leak.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 29 July 2008
Resolved
Provide eight additional life jackets to meet the total listed on the COI, Prior to carrying more than 92 passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 6 August 2008
Resolution: Attended vessel verified adequate number required life jackets were available for maximum passengers allowed on the COI.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 July 2008
Resolved
Provide a proper battery box for the STBD battery inthe bow thruster space IAW 46 CFR 183.05-20(d). Currently the installed battery box is cracked and unservicable.
Condition: Damaged By Earlier Event
Due 12 August 2008
Resolved 6 July 2009
Resolution: Verified the requirement met last year. Due to my oversight requirement not corrected in MISLE.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 July 2008
Resolved
Provide a proper bilge high level audible alarm in the engine room IAW 46 CFR 182.530(a). Currently all alarms operate properly with the exception of the audible alarm for the engine room. The indicator light for the engine room is operable.
Condition: Damaged By Earlier Event
Due 12 August 2008
Resolved 6 July 2009
Resolution: Verified the requirement met last year. Due to my oversight requirement not corrected in MISLE.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 July 2008
Resolved
Secure all bilge alarms in place IAW 46 CFR 182.53. Currently all bilge alarms are connected to small electric bilge pumps in addition to the fixed system. The electric bilge pumps are set in the bilge and not mounted in place.
Condition: Improper Installation
Due 12 August 2008
Resolved 6 August 2008
Resolution: Attended vessel, verified discrepancy was corrected.
Documentation › Certificates/Documents › FCC SSL
Issued 29 July 2008
Resolved
Provide Proper FCC Radio Safety Cert and Marine Operators permit IAW 47 CFR 13. Curently the new vessel operator has not received the required documents.
Condition: Unknown
Due 29 August 2008
Resolved 6 July 2009
Resolution: Verified the requirement met last year. Due to my oversight requirement not corrected in MISLE.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 29 July 2008
Resolved
Provide proper Coast Pilot and CG light list for the area transited IAW 46 CFR 184.42.
Condition: Improper/Lack of Maintenance
Due 12 August 2008
Resolved 6 August 2008
Resolution: Attended vessel, verified discrepancy was corrected.
Stability › Weathertight Integrity › General
Issued 29 July 2008
Resolved
Seal Wasted deck above the main Switchboard for the #2 generator IAW 46 CFR 183.01-15 (Old -T). Currently there is a small hole in the under the door sill, recommend sealing with Caulk to prevent entrance of water.
Condition: Damaged By Earlier Event
Due 12 August 2008
Resolved 6 August 2008
Resolution: Attended vessel, verified discrepancy was corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 May 2007
Resolved
Provide proper ring buoy floating water light in accordance with 46 CFR 180.70. Currently the vessel's floating water light is cracked.
Condition: Placed in Improper Service
Due 23 June 2007
Resolved 6 June 2007
Resolution: Received a receipt from the vessel operator verifying the cracked water light was replaced.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 May 2007
Resolved
Provide a proper first aid kit in accordance with 46 CFR 184.710. Currently the vessel's first aid kit contains expired item.
Condition: Improper/Lack of Maintenance
Due 1 June 2007
Resolved 6 June 2007
Resolution: Received a receipt from the vessel operator verifying the expired items had been replaced.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 22 May 2007
Resolved
Provide proper emergency instructions in accordance with 46 CFR 185.510. Currently the vessels emergency instructions are general in nature and do not address the particulars of the vessel and its operation.
Condition: Placed in Improper Service
Due 23 June 2007
Resolved 6 June 2007
Resolution: Received an updated copy of the vessels emergency procedures which adequately addressed the specifics of the vessel.
Fire Fighting › Fire Main › Material
Issued 5 May 2006
Resolved
Remove the section of rubber hose in the fire main discharge piping, renew with hard pipe.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 31 May 2006
Lifesaving › Hand Flares › Expired
Issued 5 May 2006
Resolved
Remove and renew six expired orange flares.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 31 May 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 5 May 2006
Resolved
Log monthly crew training, to include a general description of training held IAW 46CFR185.420/520/524. Drills include, Fire, Man overboard, Abandon Sip, and loss of Steering.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 5 May 2006
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 12 April 2005
Resolved
Master is renew his FCC marine operator's license and fax a copy of it to MSD Sturgeon Bay, at [phone withheld].
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 31 May 2006
Operations/Management › Drug and Alcohol Testing
Issued 24 May 2004
Resolved
Provide documentation/a copy of the contract which indicates the company is enrolled in a drug testing program LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 10 June 2004
Operations/Management › Drug and Alcohol Testing
Issued 24 May 2004
Resolved
Provide documentation from drug testing consortium which lists the employee's enrolled LEGACY COMPONENT DESC: Employee Coverage
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 10 June 2004
Operations/Management › Drug and Alcohol Testing
Issued 24 May 2004
Resolved
Provide employee's with a Drug Testing Hot Line phone number. Include/add this number to the companies drug testing policy and make number avaiable to all emploee's. LEGACY COMPONENT DESC: EAP Display Requirements
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 10 June 2004
Operations/Management › Drug and Alcohol Testing
Issued 24 May 2004
Resolved
Submitt/provide documentation which indicates Jenifer Kuether had submitted to a pre-employment drug test. LEGACY COMPONENT DESC: Testing, Pre-employment
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 10 June 2004
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drug and Alcohol Testing
Issued 24 May 2004
Resolved
Provide documentation which indicates that all crewmembers/employee's have read and understand the compaines Drug Testing policy. LEGACY COMPONENT DESC: EAP Training Requirements
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 June 2004
Resolved 10 June 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 22 April 2003
Resolved
Pilot house Fire Extinguisher not serviced, required extinguisher be serviced by approved service company LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2003
Resolved 9 May 2003
Construction/Loadline › Penetrations
Issued 22 April 2003
Resolved
Plug old bolt holes in bulkhead, between comp # 4 and comp #5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2003
Resolved 9 May 2003
Operations/Management › Drills/Instruction › Safety Orientation
Issued 10 April 2002
Resolved
Emergency Instructions not posted in passenger accommodation space.
Condition: Unknown
Due 11 April 2002
Resolved 11 April 2002
Resolution: Emergency instructions posted on main deck in passenger accommodation space.
Engineering › Bilge Water Management System
Issued 10 April 2002
Resolved
High water bilge indicators have no audible alarm for #3 & #4 compartments. Although the indicator lights did operate. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Due 10 April 2002
Resolved 10 April 2002
Resolution: Alarms were connected same day.
Unknown
Issued 25 April 2001
Resolved
Replace flexible hose in the bilge system near the bilge pump with fixed metal piping.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Unknown
Issued 25 April 2001
Resolved
Install machinery guard on the head blower located in the #5 compartment.
Condition: Unknown
Due 25 May 2001
Resolved 4 June 2001
Engineering
Issued 25 April 2001
Resolved
Replace all plastic through hull fighting with metalic.
Condition: Unknown
Due 10 April 2002
Resolved 10 April 2002
Resolution: Brass thru-hull fittings properly installed.
Unknown
Issued 25 April 2001
Resolved
Install stuffing tube in the fwd wt bulkhead for the bow thruster wiring.
Condition: Unknown
Due 25 May 2001
Resolved 4 June 2001
Documentation
Issued 14 April 1999
Resolved
Vsl operator failed to have all the required documentation to complete the chemical testing audit.
Condition: Unknown
Due 11 June 1999
Resolved 22 September 1999
Electrical
Issued 16 July 1998
Resolved
REPAIR EXTERIOR 120 VOLT LIGHTING ON PASSENGER DECK.
Condition: Unknown
Due 20 August 1998
Resolved 16 September 1998
Electrical
Issued 16 July 1998
Resolved
MAKE PROPER SPLICE OF 120 VOLT CONNECTION IN PROTECTIVE BOX IN ENGINE ROOM.
Condition: Unknown
Due 6 August 1998
Resolved 16 September 1998
Lifesaving
Issued 16 July 1998
Resolved
PROVIDE 12 ADULT TYPE 1 PFD'S WITH VESSEL'S NAME ON THEM.
Condition: Unknown
Due 16 July 1998
Resolved 22 July 1998
Accommodation/Occupational Safety
Issued 16 July 1998
Resolved
INSTALL EXIT MARKINGS FOR AFT DOORS WITH 2" HIGH LETTERS.
Condition: Unknown
Due 23 July 1998
Resolved 3 August 1998
Electrical
Issued 16 July 1998
Resolved
INSTALL AMP METER FOR AFT BATTERY CHARGER IN ENGINE COMPARTMENT.
Condition: Unknown
Due 6 August 1998
Resolved 3 August 1998
Engineering
Issued 16 July 1998
Resolved
RELABLE EMERGENCY FUEL SHUT OFF TO INDICATE PULL IS UNDER THE DECK COVER.
Condition: Unknown
Due 23 July 1998
Resolved 3 August 1998
Unknown
Issued 16 July 1998
Resolved
VESSEL'S USER FEE IS OVERDUE, ANNUAL FEE IS 300.00 FOR PERIOD 01JAN98- 31MAY99.
Condition: Unknown
Due 23 July 1998
Resolved 16 September 1998
Lifesaving
Issued 16 July 1998
Resolved
PROVIDE ADDITIONAL ITEMS FOR VESSEL'S FIRST AID KIT.
Condition: Unknown
Due 23 July 1998
Resolved 16 September 1998
Engineering
Issued 16 July 1998
Resolved
INSTALL 30X30 MESH SCREEN FOR FUEL OIL VENT PIPE.
Condition: Unknown
Due 6 August 1998
Resolved 16 September 1998
Construction/Loadline
Issued 18 July 1997
Resolved
SECURE ALL BILGE SUCTION LINES TO PREVENT SHIFTING.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Electrical
Issued 18 July 1997
Resolved
COVER ALL EXPOSED LAMPS WITH A GLOBE.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Lifesaving
Issued 18 July 1997
Resolved
SUPPLY A U.S. COAST GUARD APPROVED FIRST AID KIT IN ACCORDANCE WITH 46 CFR 160.041 OR A KIT WITH EQUIVALENT CONTENTS WITH INSTRUCTIONS.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Lifesaving
Issued 18 July 1997
Resolved
COMPLY WITH THE NEW REQUIREMENT TO PERFORM AND LOG THE FOLLOWING DRILL'S: ABANDON SHIP, MAN OVERBOARD, AND FIRE DRILL. DRILL'S SHALL BE PERFORMED EVERY THREE MONTHS AND LOGGED AS PER 46 CFR 185.520/.524.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Documentation
Issued 18 July 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Electrical
Issued 18 July 1997
Resolved
INSTALL A VOLTMETER, AMMETER AND FREQUENCY METER FOR MONITORING THE ELECTRICAL FUNCTIONS OF THE A.C. SHIP SERVICE GENERATOR. REF: 46 CFR 183.329(2)(C).
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Lifesaving
Issued 18 July 1997
Resolved
PERFORM EMERGENCY UNDERWAY. DRILL'S ARE TO BE WITNESSED BY A U.S. COAST GUARD MARINE INSPECTOR. DRILL'S SHALL INCLUDE BUT ARE NOT LIMITED TO MAN OVERBOARD, FIRE, STEERING CASUALTY AND FIRST AID.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Accommodation/Occupational Safety
Issued 18 July 1997
Resolved
PROVE OPERATION AND MARK THE MAIN/EMERGENCY SHUT DOWN SWITCH FOR THE ENGINEROOM POWER VENTILATION BLOWER.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Deck/Cargo
Issued 18 July 1997
Resolved
PROVIDE THE CORRECT SIZE ANCHOR FOR THE VESSEL. ANCHOR SHALL BE A MINIMUM OF 60 POUNDS.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Lifesaving
Issued 18 July 1997
Resolved
MARK DISTRESS FLARE CONTAINERS AS PER 46 CFR 185.614.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Deck/Cargo
Issued 18 July 1997
Resolved
SUPPLY VESSEL WITH 200' OF 1" ANCHOR LINE._x001C_
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Construction/Loadline
Issued 18 July 1997
Resolved
MAKE PERMANENT REPAIRS TO THE ENGINE COMPARTMENT BILGE SUCTION STRAINER.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Construction/Loadline
Issued 18 July 1997
Resolved
PAINT DRAFT MARKS OR LOAD MARKS IN WAY OF THE BOW AND STERN.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Electrical
Issued 18 July 1997
Resolved
SUPPLY A EMERGENCY MEANS TO DISCONNECT THE BATTERIES FROM THE LOAD. _x001C_ REF 46 CFR 183.380 (i). SUBMIT A WRITTEN PROPOSAL PRIOR FOR APPROVAL TO THIS OFFICE PRIOR TO INSTALLATION.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Construction/Loadline
Issued 18 July 1997
Resolved
INSTALL NEW HOME PORT ON STERN OF VESSEL.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Construction/Loadline
Issued 18 July 1997
Resolved
INSTALL SAFETY CHAIN IN WAY OF THE FWD HATCH COVER.
Condition: Unknown
Due 26 July 1997
Resolved 31 July 1997
Electrical
Issued 18 July 1997
Resolved
INSTALL DRIP SHIELDS IN WAY OF THE ENGINE ROOM BATTERY CHARGERS TO PREVENT ELECTRICAL SHOCK AND FIRE. INSTALL A AMMETER ON THE AFTER BATTERY CHARGER.REF 46 CFR 183.350(f).
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Engineering
Issued 18 July 1997
Resolved
DEMONSTRATE LOCAL MEANS OF SHUTING DOWN OF VESSEL'S MAIN ENGINES.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Construction/Loadline
Issued 18 July 1997
Resolved
INSTALL HIGH LEVEL BILGE ALARMS AND VISUAL INDICATION AS REQUIRED BY 46 CFR182.530. OWNER TO SUBMIT PLANS PRIOR TO INSTALLATION OF THE SYSTEM.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Lifesaving
Issued 13 December 1995
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE IN OPERATIONS OTHER THAN DOCKSIDE CONDUCT UNDERWAY DRILLS TO THE SATISFACTION OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 13 December 1995
Resolved 13 December 1995
Lifesaving
Issued 2 June 1994
Resolved
Conduct emergency drills with the assigned vessel crew not later than the compliance date.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Documentation
Issued 2 June 1994
Resolved
Provide valid document not later than the compliance date.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Construction/Loadline
Issued 12 May 1993
Resolved
Replace deteriorated flexible connecting hose for the fire and bilge systems not later than the compliance date.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 12 May 1993
Resolved
Provide separate stowage for adult and child life preservers not later thanthe compliance date.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 12 May 1993
Resolved
Conduct emergency drills with the assigned vessel crew not later than the compliance date.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 20 August 1992
Resolved
Repair life preserver aft stowage areas to prevent entry of water not laterthan the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Electrical
Issued 20 August 1992
Resolved
Disconnect and seal off all unused electrical wiring under pilothouse console not later than the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Electrical
Issued 20 August 1992
Resolved
Provide covers for missing circuit breakers in pilothouse not later than the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Fire Fighting
Issued 20 August 1992
Resolved
Provide bracket for forward main deck fire extinguisher not later than the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Lifesaving
Issued 20 August 1992
Resolved
Prove operation of the fire and bilge systems prior to operating the vesselbut not later than the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Lifesaving
Issued 20 August 1992
Resolved
Conduct underway emergency drills with full vessel crew prior to operating the vessel but not later than the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Construction/Loadline
Issued 20 August 1992
Resolved
Repair or replace broken anchor locker door not later than the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Electrical
Issued 20 August 1992
Resolved
Replace broken battery box covers, empty water as necessary from the boxes and install all covers correctly prior to operating the vessel but not later than the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Documentation
Issued 20 August 1992
Resolved
Vessel document has expired. Prove documentation prior to operating the vessel but not later than the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Lifesaving
Issued 20 August 1992
Resolved
Provide approved visual distress signals; one additional day signal and sixnight signals prior to operating the vessel but not later than the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Unknown
Issued 20 August 1992
Resolved
Provide evidence that all crewmembers are enrolled in DOT random drug testing program per 46 CFR, PART 16. not later than the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Construction/Loadline
Issued 20 August 1992
Resolved
Permanently mark bilge suction valves prior to operating the vessel but notlater than the compliance date. The current marking tags are not properly affixed to mark the valves.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Accommodation/Occupational Safety
Issued 20 August 1992
Resolved
Repair leaking fresh water pump not later than the compliance date.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Lifesaving
Issued 16 June 1988
Resolved
PROVIDE 6 RED FLARES AND 6 ORANGE SMOKE DISTRESS SIGNALS OR 12 COMBINATION RED FLARE AND ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Lifesaving
Issued 16 June 1988
Resolved
PROVIDE VESSEL NAME ON ALL PFD'S.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Lifesaving
Issued 16 June 1988
Resolved
PROVIDE VESSEL NAME ON RING BUOY.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Construction/Loadline
Issued 28 May 1987
Resolved
LABEL BILGE MANIFOLD.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Construction/Loadline
Issued 28 May 1987
Resolved
REPLACE FRACTURED BILGE MANIFOLD VALVE.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Unknown
Issued 28 May 1987
Resolved
REPAIR FUEL OIL LEAKS IN THE MAIN SUCTION LINE (JUST AFT OF THE MAIN FUEL TANK).
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Fire Fighting
Issued 28 May 1987
Resolved
REPLACE FIRE HOSE AND PROVIDE A SUITABLE NOZZLE.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Lifesaving
Issued 28 May 1987
Resolved
PROVIDE 2 ADDITIONAL CHILD LIFE PRESERVERS.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Construction/Loadline
Issued 28 May 1987
Resolved
REMOVE SAND BAGS FROM SEWAGE COMPARTMENT.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Deck/Cargo
Issued 28 May 1987
Resolved
REMOVE STORES (PAINTS AND OILS) FROM THE NO 3 COMPARTMENT.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Deck/Cargo
Issued 28 May 1987
Resolved
CLEAN RESIDUAL FUEL OIL FROM VOID.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Unknown
Issued 28 May 1987
Resolved
SECURE CONVECTION HEATED CABINET.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Lifesaving
Issued 28 May 1987
Resolved
PROVIDE 60 FOOT LINE FOR LIFE RING.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Fire Fighting
Issued 28 May 1987
Resolved
LABEL FIRE PUMP SWITCH (PILOT HOUSE).
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Lifesaving
Issued 28 May 1987
Resolved
RELABEL THE CHILD LIFE JACKET STOWAGE COMPARTMENT WITH THE CORRECT NUMBER OF CHILD LIFE JACKETS.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Construction/Loadline
Issued 28 May 1987
Resolved
TEST THE BILGE SYSTEM.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Unknown
Issued 28 May 1987
Resolved
GROUND FUEL OIL FILL LINE.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Unknown
Issued 28 May 1987
Resolved
PROVIDE ADDITIONAL FUEL OIL LINE SUPPORTS TO MAIN FUEL OIL SUCTION.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Lifesaving
Issued 28 May 1987
Resolved
POST THE EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Fire Fighting
Issued 28 May 1987
Resolved
LABEL EMERGENCY FUEL OIL SHUT OFF VALVE WITH 1 INCH LETTERS.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Engineering
Issued 11 September 1986
Resolved
REPAIR LEAKING DIESEL FUEL FILTER IN ENGINE COMPARTMENT.
Condition: Unknown
Due 11 September 1986
Resolved 11 September 1986
Accommodation/Occupational Safety
Issued 11 September 1986
Resolved
SUBMIT DETAILED PLANS FOR INSTALLATION OF NON-APPROVED TWIN HEATING/AIR CONDITIONING UNITS. PLANS SHOULD DETAIL ELECTRICAL,PLUMBING, AND MANUFACTURER DATA ON BOTH UNITS, INCLUDING MODIFICATIONS TO VESSEL WIRING, HULL PENETRATIONS, AND GENERAL ARRANGEMENT.
Condition: Unknown
Due 11 September 1986
Resolved 11 September 1986
Documentation
Issued 7 August 1986
Resolved
POST CERTIFICATE OF INSPECTION, STABILITY LETTER, AND EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Fire Fighting
Issued 7 August 1986
Resolved
REMOVE B-II PORTABLE FIRE EXTINGUISHER FROM ENGINE COMPARTMENT AND AFFIX TOADJACENT BULKHEAD ON MAIN DECK.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Engineering
Issued 19 June 1986
Resolved
MOVE THE FUEL TANK VENT TO OUTSIDE THE COMPARTMENT TO A SPOT WHERE ADEQUATEVENTILATION IS ACCOMPLISHED.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Engineering
Issued 19 June 1986
Resolved
EXTEND THE EXHAUST DUCT FOR THE ENGINE ROOM VENTILATION TO A POINT NEAR THEBOTTOM OF THE COMPARTMENT WHERE NORMAL WATER IN THE BILGE WILL NOT BE TRAP.THE DUCT SHALL BE OF RIGID PERMANENT CONSTRUCTION OF FIRE PROOF MATERIAL AND REASONABLY GASTIGHT.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Engineering
Issued 19 June 1986
Resolved
SECURE FUEL SUPPLY LINES FROM EXCESSIVE MOVEMENT AND VIBRATION.
Condition: Unknown
Due 19 June 1986
Resolved 19 June 1986
Accommodation/Occupational Safety
Issued 30 May 1986
Resolved
MODIFY MSD TANK VENT SO THAT TANK WILL NOT DISCHARGE RAW SEWAGE THROUGH VENT IF TANK REACHES CAPACITY, OR INSTALL HIGH LEVEL ALARM IN TANK.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986