MAURY USCG vessel records Sign in
← All vessels

OCEAN THUNDER

OCEAN THUNDER is a 1986 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1986, most recently in January 2025, along with 75 deficiencies — 1 with no resolution recorded —.

Records from 1986 to 2025. Most recent: inspection, 9 January 2025.

Built
1986
Last inspected
9 January 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK7114
267785
Flag
UNITED STATES
368081320
Maury page id
psix-267785

Inspections, by type

…with no type recorded4
Years with a record 32 calendar years (1986–2025)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)77.2 ft × 24.0 ft × 8.5 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTEREY, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 21 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK7114MMSI 368081320 · active · compulsorily equipped · granted 13 March 2019, expires 13 March 2029
WDG6230MMSI 367554780 · cancelled · compulsorily equipped · granted 29 November 2012, cancelled 30 July 2019 · licensed under a name not among this hull’s recorded names (not shown)
WDD3423MMSI 367131170 · expired · compulsorily equipped · granted 22 July 2006, cancelled 24 September 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDB5810MMSI 366913720 · expired · voluntarily equipped · granted 21 November 2003, cancelled 25 January 2014 · licensed under a name not among this hull’s recorded names (not shown)
WSA2770MMSI not assigned · expired · compulsorily equipped · granted 13 October 1995, cancelled 18 March 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 53

9 January 2025 Deficiency Check · Administrative Inspection · Inclining Experiment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8059754
14 March 2024 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7878794
29 November 2022 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7601569
24 February 2020 Construction Oversight · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6917995
26 November 2018 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6586776
12 January 2018 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6323562
1 December 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6313439
13 February 2017 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6083955
4 January 2016 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5790399
21 October 2015 Deficiency Check · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5734270
16 May 2012 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4311794
26 July 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4094961
16 July 2008 Administrative Inspection · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3269467
5 May 2008 Hull Examination · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3199357
11 May 2007 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2927559
26 June 2006 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2691717
24 March 2006 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2608719
27 July 2004 Type not recorded
No type recorded · USCGC NAUSHON (WPB 1311) · USCG Arctic District (CGD-A) · Activity 2202120
24 May 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2076345
23 April 2004 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2050676
19 May 2003 Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1824440
15 May 2002 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1616911
1 March 2002 Deficiency Check · Hull Examination
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 1492645
1 November 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1439287
24 April 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1447105
27 March 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1361427
24 February 2000 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1469293
20 July 1999 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1101876
6 April 1999 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 787111
19 January 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 811094
17 April 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 789339
27 February 1998 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1117294
15 April 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1099050
10 April 1996 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1082955
12 February 1996 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 877596
23 June 1995 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 883814
31 March 1995 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 838050
18 April 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 868901
7 April 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1167470
19 April 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1142205
27 April 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 961505
1 April 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 960096
6 March 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1316627
22 March 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 997703
8 February 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 902409
30 March 1990 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 932997
9 March 1990 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 902781
30 March 1989 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1042072
24 February 1989 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1196464
18 March 1988 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1337933
2 October 1987 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1318664
24 March 1987 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1020127
2 April 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303963

Deficiency record · 75

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 February 2020 No resolution recorded
Repairs or alterations to machinery or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant OCMI. Vessel has not undergone required USCG plan review and approval for repower and system modifications.
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 February 2020 Resolved
The owner of a vessel must conduct a stability test of the vessel. Vessel shall undergo required stability test in the presence of USCG. 46 CFR 170.175(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2025
Resolution: Vessel completed stability test.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 12 January 2018 Resolved
Renew expired FCC safety certificate. 47 CFR 80.401
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 1 February 2018
Resolution: FCC licensed technician attended to conduct safety inspection and issue renewal safety certificate.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 January 2018 Resolved
Provide proof of current drug consortium enrollement of company and vessel crew.
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 13 February 2018
Resolution: Proof of current drug consortium enrollement of company and vessel crew provided.
Lifesaving › Lifefloat › Serviceable
Issued 13 February 2017 Resolved
All lifefloats, except the the one located in the center at the bottom, require repair or replacement. (Paint and patches required if repaired)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 7 March 2017
Resolution: Repainted and patched all life floats except center bottom.
Lifesaving › Lifefloat › Pendant
Issued 13 February 2017 Resolved
The lifefloat located on the center bottom was not attached to a pendant.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 7 March 2017
Resolution: Attached life float to pendant.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 February 2017 Resolved
The microwave at the top of the fridge was connected to an extention cord and not hardwired to electrical system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 8 March 2017
Resolution: Moved microwave to a different location where the extension cord is not used.
Fire Fighting › Fire Hoses › Material
Issued 13 February 2017 Resolved
The fire hose on board the vessel are not provided with prove of UL 19 approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 7 March 2017
Resolution: Replaced both hoses with UL spproved hoses.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 13 February 2017 Resolved
Aft starboard side window glass is cracked
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 7 March 2017
Resolution: Replaced window.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 January 2016 Resolved
Provide onboard updated copies of Coast Pilot [name withheld], Tides & Currents and Nautical Chart, IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 9 February 2016
Resolution: Up to date copies provided onboard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 January 2016 Resolved
Renew lenses for Masthead, Stern light, and Anchor light. Stern & Masthead are darkening and the Anchor lens is turning yellow. IAW 46 CFR 183.420 & Nav Rules 84.13.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 9 February 2016
Construction/Loadline › Structures › Deck Plating
Issued 13 January 2016 Resolved
Seal holes in Main deck forward lifejacket storage area, IAW 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 9 February 2016
Lifesaving › Lifebuoys › Serviceable
Issued 13 January 2016 Resolved
Renew faded ringbuoy aft, port side, IAW 46 CFR 180.70(b)(5).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 January 2016
Resolution: Crew renewed Ringbuoy.
Lifesaving › Lifefloat › Platform
Issued 13 January 2016 Resolved
Provide spacers for stacked lifefloats IAW 46 CFR 180.137(f).
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 January 2016
Resolution: Spacers installed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 21 October 2015 Resolved
Noted hydraulic oil in the forward void bilge area. Remove oil from bilge. 46 CFR 176.830
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 November 2015
Resolved 15 December 2015
Resolution: Hydraulic oil was removed from bilge and residual was wipped up.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 21 October 2015 Resolved
Center main diesel engine exhaust piping is showing signs of possible saltwater leak & exhaust leak. Remove exhaust lagging for further inspection. 46 CFR 182.430
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Inspected exhaust piping and found cracks causing raw water leakage and exhaust leakage. Fabricated new exhaust piping and installed the same. Showed proper operation of system.
Accommodation/Occupational Safety › Potable Water System › General
Issued 21 October 2015 Resolved
Through hull fittign for potable water sytems located on port side of main deck is severly corroded with that has wasted weld and wasted the fitting. Replace fitting. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Installed new through hull fitting and rewelded. All SAT
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 21 October 2015 Resolved
Found loose or missing exhaust lagging on center and port main diesel engine. Repair or replace exhaust lagging identified. 46 CFR 177.970
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Replaced missing exhaust lagging and tightened other exhaust lagging listed during inspection.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 21 October 2015 Resolved
Both port and starboard shaft log hoses need replacement. When hoses are removed inspect make shaft logs ready for inspection.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 18 November 2015
Resolution: Both shaft logs had been inspected and replaced with 1/2" wall thick shaft logs. Logs are approximatel 6" in length welded inside and out. Replaced all hoses. All SAT
Electrical › Electric Generation Source (service) › Panelboard
Issued 21 October 2015 Resolved
Electrical breaker panel located in the engine room on starboard side aft is missing mounting hardware and blind plug. Install missing mounting hardware and blind plug. 46 CFR 183.330
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Replaced missing parts on electrical breaker and missing blind plug. All SAT
Electrical › Electric Generation Source (service) › Conductor
Issued 21 October 2015 Resolved
Their are wire nuts used to splice wires together for bilge pump located aft of engine room. Wiring is underneath bilge water. Repair or replace wiring with proper splicing. 46 CFR 183.340(i)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Wiring was butt connected and shrink wrapped for aft bilge pump in the engine room.
Electrical › Electric Supply System (service) › Cable
Issued 21 October 2015 Resolved
Outboard shore tie connection located on portside aft has one of its broken off inside plug. Replace plug. 46 CFR 183.390
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Shore tie connection was removed from circuit and cable was properly secured. All SAT
Accommodation/Occupational Safety › Potable Water System › General
Issued 21 October 2015 Resolved
Hose bib spigot located aft port side under shore tie connection is severly corroded were it is mounted to superstructure. Remount and make watertight. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Vessel remove hose bib and repaired affected area and remounted hose bib. All SAT
Construction/Loadline › Hull › Keel
Issued 21 October 2015 Resolved
Keel section of hull has cracks located portside aft of keel. Keel is full of water. Remove water and and repair cracks in keel. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Cracks were repaired and drain plug was added at bottom of keel. SAT
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 21 October 2015 Resolved
Remove starboard outboard muffler in lazarette, remove all corrosion & check for proper piping thickness. 46 CFR 182.430
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Removed muffler inspected metal for thickness and repaired areas by clad welding and grinding down that were severly pitted. Installed and tested, Test SAT.
Engineering › Steering Gear System › Ram
Issued 21 October 2015 Resolved
Repair or replace steering ram. Steering rams clevis pins are severly worn due to fastening pin wear. 46 CFR 182.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Replaced clevis pins on ends of steering rams. Operationally SAT
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 21 October 2015 Resolved
Forward bulkhead located in lazarette starboard side under sewage piping is a crack in bulkhead. Repair crack. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Gouged and repaired crack by welding. SAT
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 21 October 2015 Resolved
Sewage system piping located in lazarette starboard side were it turns and goes up has severe pitting. Repair pitting. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: The severly pitting sewage piping was cut out and replaced with new piping. All SAT
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 21 October 2015 Resolved
Exhaust piping located portside lazarette is missing hose clamps were it connects to mufflers. Replace hose clamps on piping and muffler. 46 CFR 182.430
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: All hose clamps identified that were missing were replaced. All SAT
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 October 2015 Resolved
Main deck non-skid is non-existent due to normal wear causing slipping hazard. Install non-skid on entire main deck. 46 CFR 175.400
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Main deck was coated with non-skid elimating slipping hazard. All SAT.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 21 October 2015 Resolved
Center shaft has crack in keyway. Crack extends into keyway by 1/2" and around shaft 1/2". Remove and repair or replace shaft. 46 CFR 176.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Vessel replaced shaft with new shaft. All SAT
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 October 2015 Resolved
Wiring for auto pilot in the j-box is missing cover plate and severly wasted. Replace junction box with new. 46 CFR 183.340(i)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Installed new junction box for auto pilot in lazarette.
Engineering › Generator (propulsion/auxiliary-electric) › Measurement Circuitry
Issued 21 October 2015 Resolved
Provide new documentation/specification for newly installed generator. 46 CFR 176.600
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 October 2015
Resolved 15 December 2015
Resolution: Owner provided specifications for newly installed generator.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 May 2012 Resolved
COD expired 12/31/2011. Provide current Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2012
Resolution: Provided current Certificate of Documentation.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 May 2012 Resolved
Light on lifebuoy inoperable. Provide working water light for lifebuoy.
Action required: 705 - Other - as specified
Due 16 May 2012
Resolved 16 May 2012
Resolution: Provided working water light for lifebuoy.
Fire Fighting › Fire Pumps › Pressure
Issued 16 May 2012 Resolved
Fire pump unable to provide more than 15psi. Make repairs, demonstrate satisfactory discharge pressure from fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2012
Resolved 16 May 2012
Resolution: Made repairs, demonstrated satisfactory discharge pressure from fire pump.
Lifesaving › Lifefloat › Serviceable
Issued 16 May 2012 Resolved
Two 22 person Life floats full of water, unable to lift with two persons due to weight. Provide approved primary life savings for same number of persons (44). Vessel restricted to 106 persons.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 30 May 2012
Resolution: Provide approved primary life savings for same number of persons (44). Two life floats in serviceable condition, properly marked for 22 persons each.
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2012 Resolved
Marine charts last correction was in year 2000. Provide current charts of area of operation.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 30 May 2012
Resolution: Provided current charts of area of operation.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 July 2011 Resolved
Ring buoy light is inoperable. Repair/replace with operable light.
Action required: 705 - Other - as specified
Due 3 August 2011
Resolved 2 August 2011
Communications › Audible Communications › Horn/Whistle
Issued 26 July 2011 Resolved
Vessel's horn is inoperable. Repair/replace horn.
Action required: 705 - Other - as specified
Due 3 August 2011
Resolved 2 August 2011
Engineering › Bilge Water Management System › Piping
Issued 5 May 2008 Resolved
Found a small crack in bilge piping in void #3, crop and renew as original.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2008
Resolved 9 July 2008
Resolution: Grounded and welded crack in pipe
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 May 2007 Resolved
Owner did not have current Documentation onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 17 May 2007
Resolution: Determined vessel has a valid Certificate of Documentation.
Engineering › Bilge Water Management System › Not Operational
Issued 11 May 2007 Resolved
Attempted to dewater forward void, but system was not working properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 17 May 2007
Resolution: Owner preformed maintenance on bilge system and determined a faulty check valve. Tested bilge manifold system, all test sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 June 2006 Resolved
Provide annual servicing for portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Due 30 June 2006
Resolved 30 June 2006
Resolution: Received fax copy of fire extinguishing servicing report. All sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 May 2004 Resolved
Conduct 30 minute rounds on Lazarette until high water level sensor is repaired/tested.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 25 May 2004
Resolution: Repaired and tested.
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 24 May 2004 Resolved
Post proper line diagram and dewatering instructions for installed bilge system.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 25 May 2004
Resolution: Posted proper line diagram and dewatering instructions and tested, test SAT.
Lifesaving › Lifefloat › Retroreflective Material
Issued 24 May 2004 Resolved
Provide 2 waterlights for lifefloats prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2004
Resolved 25 May 2004
Resolution: Provided 2 waterlights for lifefloats.
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 May 2004 Resolved
Reinstall valve handle for STBD MDE fuel shutoff.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 25 May 2004
Resolution: Reinstalled valve handle for STBD MDE fuel shutoff.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 24 May 2004 Resolved
Post emergency broadcast placard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 25 May 2004
Resolution: Posted emergency broadcast placard.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 24 May 2004 Resolved
Remove Combustible trash receptacles from the vessel.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 25 May 2004
Resolution: Replaced Combustible containers with non-combustible.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 19 May 2003 Resolved
Restencil Passenger Capacity LEGACY COMPONENT DESC: Open Deck Space
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 30 May 2003
Resolution: Restenciled passenger capacity
Fire Fighting › Fire Hydrants
Issued 19 May 2003 Resolved
Repair Stbd Firestation Valve, Valve is leaking by. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 30 May 2003
Resolution: Repaired Stbd firestation valve.
Communications › Alarms/Indicators
Issued 19 May 2003 Resolved
Replace inoperable Stbd Tachometer LEGACY COMPONENT DESC: Propeller Speed Indicator
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 30 May 2003
Resolution: Replaced inoperable Stbd Tachometer
Operations/Management › Equipment Service/Testing
Issued 19 May 2003 Resolved
Prove proper operation of remote operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 30 May 2003
Resolution: Proved proper operation of the remote operating station
Engineering › Generator (propulsion/auxiliary-electric)
Issued 19 May 2003 Resolved
Properly install battery LEGACY COMPONENT DESC: Battery
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 30 May 2003
Resolution: Installed battery properly
Engineering › Fuel Oil Service System
Issued 19 May 2003 Resolved
Repair minor fuel leak on Stbd MDE fuel filter. LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 30 May 2003
Resolution: Repaired minor fuel leak on stbd MDE fuel filter
Engineering › Fuel Oil Storage/Transfer System
Issued 19 May 2003 Resolved
Replace Flame screen on fuel tank vent. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 30 May 2003
Resolution: Replaced flame screen
Construction/Loadline › Hull › Bottom Plating
Issued 15 May 2002 Resolved
Make sewage void available for inspection during next haul out (November 2002 timeframe). Found pits approaching 25% wastage of hull under sewage tank. Additionally, bulkhead is pitted as well as stiffeners. LEGACY COMPONENT DESC: Bottom Plating
Due 1 November 2002
Resolved 23 April 2004
Resolution: Checked pits, all sat
Construction/Loadline › Structures
Issued 1 March 2002 Resolved
Repair damage to pulpit, portside LEGACY COMPONENT DESC: Pulpit
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 March 2002
Resolved 5 March 2002
Resolution: Repairs complete
Construction/Loadline › Structures
Issued 1 March 2002 Resolved
Repair cracks in the following locations on the main deck: 1) Top of gunwale, forward of rail post #6, portside 2) First bitt, at top of gunwale, portside LEGACY COMPONENT DESC: Gunwale
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 May 2002
Resolved 16 May 2002
Construction/Loadline › Hull
Issued 1 March 2002 Resolved
Repair damaged rub rail and corner at stern platform, portside LEGACY COMPONENT DESC: Rub rail
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 May 2002
Resolved 16 May 2002
Engineering › Shafting/Propeller Arrangements
Issued 1 March 2002 Resolved
Replace starboard cutlass bearing LEGACY COMPONENT DESC: Bearing
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 May 2002
Resolved 16 May 2002
Construction/Loadline › Structures
Issued 1 March 2002 Resolved
Repair damaged railing, starboard side aft maindeck LEGACY COMPONENT DESC: Railing
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 March 2002
Resolved 5 March 2002
Resolution: Repairs completed
Construction/Loadline › Hull
Issued 1 March 2002 Resolved
Renew cracked weld, void #2, frame #6 at keel LEGACY COMPONENT DESC: Frame
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 March 2002
Resolved 5 March 2002
Resolution: Repairs, sat
Fire Fighting › Means of Escape › Escape Route Signs
Issued 1 March 2002 Resolved
Label top of emergency escape hatch for below deck passenger accommodation space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2002
Resolved 5 March 2002
Resolution: Stencil added
Engineering › Fuel Oil Storage/Transfer System
Issued 1 March 2002 Resolved
Repair leak from fuel feed line at fuel tank connection in engine room LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 March 2002
Resolved 5 March 2002
Resolution: Repair complete
Deck/Cargo › Mooring/Anchoring › Winch
Issued 1 March 2002 Resolved
Repair leaking hydraulic line in engine room and clean up residual hydraulic fluid
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 March 2002
Resolved 5 March 2002
Resolution: Complete
Engineering › Bilge Water Management System › Piping
Issued 1 March 2002 Resolved
Make permanent repairs to two bilge lines at manifold in engine room; replace soft patches.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 March 2002
Resolved 5 March 2002
Resolution: Complete
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 1 March 2002 Resolved
Replace damaged center propeller
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 March 2002
Resolved 5 March 2002
Resolution: Complete
Engineering › Steering Gear System › Rudder Bearing
Issued 1 March 2002 Resolved
Repack starboard rudder post
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 March 2002
Resolved 5 March 2002
Resolution: Complete
Engineering › Bilge Water Management System
Issued 1 November 2001 Resolved
Replace submersible pump flexible hose with proper hose & provide metallic through hull fitting with a positive shut off valve at the hull._x001C_ "BILGEFLEX" hose is only suitable for sink and shower drains and is not recommended for bilge lines. See manufacturer's sales literature. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 December 2001
Resolved 5 March 2002
Resolution: Complete
Lifesaving
Issued 24 April 2001 Resolved
Renew expired hydrostatic release for EPIRB.
Condition: Unknown
Due 8 May 2001
Resolved 24 May 2001
Electrical
Issued 24 April 2001 Resolved
Provide a frequency meter (Hz) for main switchboard.
Condition: Unknown
Due 8 May 2001
Resolved 24 May 2001
Electrical
Issued 18 April 1994 Resolved
REMOVE OR REMOUNT PA SPEAKER.
Condition: Unknown
Due 18 April 1994
Resolved 27 July 1994
Accommodation/Occupational Safety
Issued 18 April 1994 Resolved
LABEL MAXIMUM NUMBER OF PASSENGERS PERMITTED ON UPPER DECK.
Condition: Unknown
Due 18 April 1994
Resolved 27 July 1994

Ownership record