MAURY USCG vessel records Sign in
← All vessels

C-ATLANTIS

C-ATLANTIS is a 2000 offshore supply vessel. The Coast Guard has recorded 31 inspections since 2000, most recently in June 2026, along with 84 deficiencies and 2 casualty investigations between 2007 and 2008.

Records from 2000 to 2026. Most recent: inspection, 5 June 2026.

Built
2000
Last inspected
5 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9232723 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDQ9862
Flag
UNITED STATES
368458170
Maury page id
psix-2678

Inspections, by type

…with no type recorded5
Years with a record 16 calendar years (2000–2026)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)175.8 ft × 44.0 ft × 19.0 ft
Registered tonnagegross 1,335 / net 400
ITC dimensions (L × B × D)175.8 ft × 44.0 ft × 19.0 ft
ITC tonnagegross 1,335 / net 400
BuilderN. AMERICAN FABRICATORS · HOUMA, LA, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOMER, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 May 2026 · expires 31 May 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1335 - Convention (Subpart B), Gross Ton
400 - Convention (Subpart B), Net Ton
1856 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9862MMSI 368458170 · active · compulsorily equipped · granted 19 May 2026, expires 19 May 2036
WDQ8015MMSI 368458170 · cancelled · compulsorily equipped · granted 20 February 2026, cancelled 15 May 2026
WCZ7512MMSI 338728000 · expired · compulsorily equipped · granted 17 March 2010, cancelled 13 June 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA HERO Offshore Supply Vessel · MISLE 367403 · 15 April 2007 · activity 3120448

Inspection history · 31

5 June 2026 MTSA/ISPS Verification · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8381281
13 February 2026 Vessel Attendance · Administrative Inspection · COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8351334
27 June 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6728033
29 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6526312
14 July 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5940160
7 June 2016 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5900129
29 January 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5806128
12 June 2012 ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4335508
12 January 2012 Administrative Inspection · Construction Oversight · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4225833
9 August 2011 ACP Annual Oversight · DAPI Audit · Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 4069298
6 July 2009 Annual Inspection
Physical examination · Activities Europe · Activity 3533201
10 February 2009 Type not recorded
No type recorded · Activities Europe · Activity 3415154
18 December 2008 Type not recorded
No type recorded · Activities Europe · Activity 3384422
22 July 2008 Administrative Inspection
Administrative · Activities Europe · Activity 3275469
1 June 2008 Type not recorded
No type recorded · Activities Europe · Activity 3415150
14 April 2008 Annual Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 3183585
28 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245323
14 May 2007 ACP Periodic Oversight · Periodic Inspection
Physical examination · Activities Europe · Activity 2921155
15 April 2007 Type not recorded
No type recorded · Activities Europe · Activity 3120448
26 May 2006 Annual Inspection
Physical examination · Activities Europe · Activity 2643835
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501691
17 May 2005 Cargo Tank Internal · ACP COI Oversight · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2359990
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293983
6 July 2004 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2123225
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979590
13 May 2003 Re-Inspection · Internal Structural Exam · Underwater Inspection in lieu of Drydock · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1792448
29 May 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1626026
5 June 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1469356
8 July 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1051897
2 June 2000 Initial Construction-Excluding Oversight · Deadweight Survey · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365800
31 March 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818366

Deficiency record · 84

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 June 2026 Resolved
The COI issued by OCMI to a vessel required to be inspected under 46 USC 3301 specifies the minimum complement of officers and crew necessary for the safe operation of the vessel. The vessel was missing 01 Licensed Mates and the Chief Engineer listed did not have any STCW endorsement for Chief Engineer on the MMC.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 June 2026
Resolution: Vessel has obtained a CE and Licensed Mate.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 5 June 2026 Resolved
General arrangement (GA) plans (AKA Fire/Safety Plan) shall be permanently exhibited for the guidance of the ship officers and kept up to date. The immersion suits and corresponding immersion suit placards shall be placed IAW the GA plan or the GA plan updated. 74SOLAS(04) II-1/15.2.4 705 - Prior to International Voyage.
Action required: 702 - Prior to embarking on international voyage
Resolved 8 June 2026
Resolution: Accepted and Cleared by Class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 June 2026 Resolved
Electrical installations shall ensure the safety of crew from electrical hazards. The emergency steering controls had exposed wire openings next to the local controls in emergency steering. 74SOLAS(04) II-1 / 40.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2026
Resolved 8 June 2026
Resolution: Accepted and Cleared by Class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 June 2026 Resolved
Electrical installations shall ensure the safety of crew from electrical hazards. Plastic wire ties were located throughout the machinery space, bow thruster room, and aft steering for bundling wires without the support of metal wire ties every 24 inches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2026
Resolved 8 June 2026
Resolution: Accepted by Class.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 5 June 2026 Resolved
Machinery and associated piping systems shall be protected and installed to minimize risk of danger from moving parts to personnel onboard. Multiple motors throughout bow thruster, main machinery space, and steering room had missing guards over moving machinery parts. 74SOLAS(04) II-1 / 26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2026
Resolved 8 June 2026
Resolution: Accepted and Cleared by Class.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 5 June 2026 Resolved
Machinery and associated piping systems shall be protected and installed to minimize risk of working conditions in the environment it is used in. Fuel oil transfer piping had no instructions located at the fuel oil transfer station for operational use. 74SOLAS(04) II-1 / 26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2026
Resolved 8 June 2026
Resolution: Accepted and cleared by Class.
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 29 August 2018 Resolved
Vessel has failed to report via LRIT per 33 CFR 169.230.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 August 2026
Resolution: Cleared
Fire Fighting › Fire Pumps › Arrangement
Issued 24 June 2016 Resolved
Port FIFI pump on deck has a melted access cover due to heat from the exhaust. Replace with heat resistant cover.
Due 24 July 2016
Resolved 24 June 2016
Resolution: Listed as condition of class.
Fire Fighting › Means of Escape › Doorways
Issued 24 June 2016 Resolved
Two vertical stairwell fire doors will not close properly
Due 24 July 2016
Resolved 24 June 2016
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 June 2016 Resolved
Life buoys with lines were found to be coiled and wrapped and tied. They should be ready for immediate use.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Accepted as condition of class
Lifesaving › Line-Throwing Appliances › Instructions/Diagrams
Issued 24 June 2016 Resolved
The line throwing devices were not armed and did not have proper instructions for operation as per the LSA code. They either need to be armed or have proper instructions for arming.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Accepted as condition of class
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 24 June 2016 Resolved
E-light in upper bow thruster room by secondary escape route was found not working.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Bulb replaced. Corrected on the spot.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 7 June 2016 Resolved
One of the alarms in the chief engineers room had been disconnected.
Due 24 June 2016
Resolved 24 June 2016
Resolution: Corrected on the spot.
Documentation › Certificates/Documents › IOPP Certificate
Issued 12 June 2012 Resolved
Provide original IOPP Certificate and survey form
Due 14 June 2012
Resolved 14 June 2012
Resolution: ABS provided new cert. and survey
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 June 2012 Resolved
Provide Certificate of Documentation with updated tonnage.
Action required: 705 - Other - as specified
Due 30 July 2012
Resolved 7 August 2012
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 June 2012 Resolved
Prove proper operation of the Emergency Generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2012
Resolved 14 June 2012
Resolution: ABS verified proper operation.
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 5 July 2011 Resolved
Provide a stove in the galley that is approved for marine use.
Due 10 September 2011
Resolved 31 January 2012
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 July 2009 Resolved
*Item reported cleared via E-mail dated 13JUL09 and shall remain open until verified by CG Marine Inspector* Provide updated deviation table for standard magnetic compass within 7 days, 15 July, 2009.
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 12 May 2010
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 July 2009 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2009
Resolution: Vessel now manned in accordance with COI.
Documentation › Logs/Records › Logbook (official)
Issued 8 July 2009 Resolved
*Item reported cleared via E-mail dated 3AUG09 and shall remain open until verified by CG Marine Inspector* Provide on board an Official Log Book as required by 46USC11301. Comply with provisions set forth in 46CFR97.35-3(a), and 46CFR131.610, within 30 days. 8 August, 2009
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 12 May 2010
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 8 July 2009 Resolved
*Item reported cleared via E-mail dated 3AUG09 and shall remain open until verified by CG Marine Inspector* Provide two buoyant floats for line throwing apparatus as required by 46CFR160.040-4(a) within 60 days. 8 September, 2009
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 12 May 2010
Lifesaving › Launching Appliances › Release Mechanism
Issued 8 July 2009 Resolved
*Item reported cleared via E-mail dated 3AUG09 and shall remain open until verified by CG Marine Inspector* Provide CG approval for rescue boat release hook, davit, and winch as required within 60 days. 8 September, 2009
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 12 May 2010
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 8 July 2009 Resolved
Rescue boat search light found inoperable, make repairs to restore operational readiness within 7 days. 15 July, 2009
Action required: 705 - Other - as specified
Due 15 July 2009
Resolved 8 July 2009
Resolution: Repairs made to the satisfaction of the attending USCG Marine Inspector.
Fire Fighting › International Shore Connection › Gasket
Issued 8 July 2009 Resolved
Provide gasket and two washers for international shore connection within 7 days. 15 July, 2009
Action required: 705 - Other - as specified
Due 15 July 2009
Resolved 14 July 2010
Resolution: Repairs made to the satisfaction of the attending USCG Marine Inspector.
Construction/Loadline › Markings › Load Line Mark
Issued 8 July 2009 Resolved
Port side load line and seasonal markings found painted orange on an orange hull and is no longer visible. Mark black on a light ground or white/yellow on a dark ground within 7 days. 15 July, 2009
Action required: 705 - Other - as specified
Due 15 July 2009
Resolved 8 July 2009
Resolution: Correctly marked to the satisfaction of attending USCG Marine Inspector.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 8 July 2009 Resolved
*Item reported cleared via E-mail dated 22JUL09 and shall remain open until verified by CG Marine Inspector* SOLAS Safety Equipment Certificate and Safety Construction Certificate indicate incorrect keel laid date. Issuing authority to mark with correct date within 30 days. 8 August, 2009
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 12 May 2010
Documentation › Certificates/Documents › IOPP Certificate
Issued 8 July 2009 Resolved
*Item reported cleared via E-mail dated 22JUL09 and shall remain open until verified by CG Marine Inspector* Vessel’s International Oil Pollution Prevention Certificate Form A indicates that the vessel’s keel was laid prior to 13 December 1979. Issuing authority to update certificate accordingly within 30 days. 8 August, 2009
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 12 May 2010
Operations/Management › Drills/Instruction › Abandon Ship
Issued 8 July 2009 Resolved
*Item reported cleared via E-mail dated 22JUL09 and shall remain open until verified by CG Marine Inspector* Vessel’s SOLAS Training Manuals to be updated to reflect actual equipment fitted on board. Specifically for the line throwing appliances, the VHF radio telephones, DSC, SSB Radio, GPS/DGPS, NAV TEX, INMARSAT C, and GMDSS Lifeboat Radios. Incorporate updates within 30 days. 8 August, 2009
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 12 May 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 July 2009 Resolved
*Item reported cleared via E-mail dated 22JUL09 and shall remain open until verified by CG Marine Inspector* Main deck accommodation entrance inner door glass window found cracked with shattered class representing hazard to crew. Make permanent repairs within 30 days, 8 August 2009.
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 12 May 2010
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 8 July 2009 Resolved
*Item reported cleared via E-mail dated 13JUL09 and shall remain open until verified by CG Marine Inspector* Remove mechanical hold backs for self closing fire doors in engine room within 7 days, 15 July, 2009.
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 12 May 2010
Operations/Management › Drills/Instruction › Fire
Issued 8 July 2009 Resolved
*Item reported cleared via E-mail dated 3AUG09 and shall remain open until verified by CG Marine Inspector*Vessel’s fire control plans do not differentiate or clearly indicate the various fire sections enclosed by “A” class divisions and “B” class divisions. Updated plans to be submitted for approval within 30 days, 8 August 2009. 74 SOLAS 2004 Cons. (All Ships) II-2/15.2.4
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 12 May 2010
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 8 July 2009 Resolved
*Item reported cleared via E-mail dated 18AUG09 and shall remain open until verified by CG Marine Inspector* Provide rating for structural fire division of bulkhead between galley and mess room, including fire class rating and suitability for closures of entrance (door) and serving window within 30 days, 8 August 2009.
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 12 May 2010
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 6 July 2009 Resolved
Vessel’s SOLAS Safety Equipment Certificate found not endorsed for 2007 annual survey. Issuing authority to provide evidence of annual survey and endorse certificate as required within 30 days. 8 August, 2009
Action required: 705 - Other - as specified
Due 8 August 2009
Resolved 8 August 2009
Resolution: Certificate updated to reflect survey.
Documentation › Logs/Records › Oil Record Book
Issued 14 April 2008 Resolved
used current edition of oil record books.
Condition: Unknown
Due 1 June 2008
Resolved 1 June 2008
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 14 April 2008 Resolved
ISM company is to conduct an audit of the Safety management system to ensure it meets the ISM code and is effective in tracking maintenance activities.Report cleared via E-mail dated 25 mar 09, Item remains open until cleared by attending Marine Inspector.
Condition: Unknown
Due 17 May 2010
Resolved 8 July 2009
Resolution: Item found corrected to the satisfaction of attending USCG Marine Inspector.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 April 2008 Resolved
OWS is to be service as per manufacture manual to prove the 15 ppm and a procedure developed to ensure any bilge water passes though the OWS before going overboard. Received e-mail 27Jun08 advising corrected and extended due date to next annual.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 May 2010
Resolved 8 July 2009
Resolution: Item found corrected to the satisfaction of attending USCG Marine Inspector.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 May 2007 Resolved
Replace all batteries in emergency lights
Condition: Improper/Lack of Maintenance
Due 17 June 2008
Resolved 16 November 2007
Electrical › Electric Generation Source (emergency) › Generator
Issued 14 May 2007 Resolved
Prove proper operation of E gen. Prior to departure.
Condition: Improper/Lack of Maintenance
Due 14 May 2007
Resolved 14 May 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 May 2007 Resolved
Prove proper operation of oily water separator.
Condition: Improper/Lack of Maintenance
Due 15 May 2007
Resolved 15 May 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 14 May 2007 Resolved
Complete annual engineering alarm and sensor check off sheet
Due 17 June 2008
Resolved 16 November 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 May 2007 Resolved
Have fixed fire ext. system properly serviced in the presence of an attending Coast Guard inspector.
Due 14 May 2007
Resolved 14 May 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 14 May 2007 Resolved
Prove proper operation of all deck and flood lights.
Condition: Improper/Lack of Maintenance
Due 17 June 2008
Resolved 16 November 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 May 2007 Resolved
Install battery operated emergency lights in the following locations: in the lower level of the engine room directed at the stbd escape ladder & Z-Drive space directed at the escape ladder.
Due 17 June 2008
Resolved 16 November 2007
Engineering › Steering Gear System › Motor
Issued 14 May 2007 Resolved
Repair the port Z-drive electric steering motor.
Due 17 June 2008
Resolved 16 November 2007
Fire Fighting › Fire Hoses › Number
Issued 14 May 2007 Resolved
Vessel is required 14 fire hoses, the vessel is missing one hose
Condition: Improper Installation
Due 29 May 2007
Resolved 14 June 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 May 2007 Resolved
Properly repair the flood light for the rescue boat platform.
Due 17 June 2008
Resolved 16 November 2007
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 14 May 2007 Resolved
Provide life raft launching directions at all launching stations.
Due 29 May 2007
Resolved 14 June 2007
Fire Fighting › Fire Hydrants › Condition
Issued 14 May 2007 Resolved
Missing two spanner wrenches in fire stations 14 and 10.
Condition: Improper Installation
Due 29 May 2007
Resolved 14 June 2007
Engineering › Diesel Engine (propulsion-electric) › Bearing
Issued 14 May 2007 Resolved
Inspect / repair all bearings on both shafts, #10 bearing mounting bolt loose and not properly aligned. As per ABS condition of class. 10 Days one way voyage to ONNE port for repairs and verification.
Condition: Damaged By Earlier Event
Due 24 May 2007
Resolved 6 June 2007
Lifesaving › Launching Appliances › Davit
Issued 14 May 2007 Resolved
Have Fast Rescue craft davit thoroughly inspected by manufacturer representative, including the falls.
Condition: Improper/Lack of Maintenance
Due 31 October 2007
Resolved 16 November 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 14 May 2007 Resolved
Provide an approved cylinder for fixed CO2 system on paint locker. Cleared pending verification by attending CG inspector.
Condition: Improper/Lack of Maintenance
Due 17 June 2008
Resolved 1 June 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 14 May 2007 Resolved
Provide approved machinery shut down switch from the fixed firefighting system manufacturer. Cleared pending verification by attending CG inspector.
Condition: Damaged By Earlier Event
Due 31 October 2007
Resolved 16 November 2007
Documentation › Certificates/Documents › IOPP Certificate
Issued 14 May 2007 Resolved
Have the throughput of the oily water separator corrected on the IOPP supplement.
Due 14 July 2007
Resolved 16 November 2007
Lifesaving › Inflatable Liferafts › Servicing
Issued 14 May 2007 Resolved
Have damaged liferaft properly serviced.
Due 14 June 2007
Resolved 16 November 2007
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 14 May 2007 Resolved
ECO must internally audit the vessel's SMS. The audit report must include an explanation as to why and how the vessel was allowed to operate in such poor condition. The report must also include corrective action plans describing how and when compliance will be achieved and be signed by the company’s Designated Person Ashore. The report must be submitted to the CG by September 12, 2007.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 16 November 2007
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 14 May 2007 Resolved
The vessel must be re-inspected to confirm compliance with its Safety Management System by Activities Europe no later than December 12, 2007.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 16 November 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 14 May 2007 Resolved
Provide means of securing the stbd emergency escape hatch
Due 1 June 2007
Resolved 16 November 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 14 May 2007 Resolved
Prove proper operation of galley exhaust fan
Due 14 June 2007
Resolved 16 November 2007
Lifesaving › Emergency Outfit › Fire ax
Issued 14 May 2007 Resolved
Provide axes for fire fighting lockers.
Due 14 June 2007
Resolved 16 May 2007
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 14 May 2007 Resolved
Properly mount EPRIB.
Due 1 June 2007
Resolved 17 May 2007
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 14 May 2007 Resolved
Provide the original documents for the liferafts.
Due 1 June 2007
Resolved 15 May 2007
Lifesaving › Inflatable Liferafts › Float Free
Issued 14 May 2007 Resolved
Properly install all life raft hydrostatic release units.
Due 1 June 2007
Resolved 15 May 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 May 2007 Resolved
Prove proper operation of all deck and flood lights
Due 15 June 2007
Resolved 16 November 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 May 2007 Resolved
Prove proper operation of the anchor light.
Due 1 June 2007
Resolved 15 May 2007
Electrical › Electric Supply System (service) › Cable
Issued 14 May 2007 Resolved
Prove proper operation of the lamp tester on the automation panel.
Due 14 June 2007
Resolved 16 November 2007
Electrical › Electric Generation Source (service) › Conductor
Issued 14 May 2007 Resolved
Remove dead end cable from above e-gen.
Due 1 June 2007
Resolved 15 May 2007
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 14 May 2007 Resolved
Properly stow all spare batteries in the e-gen space.
Due 1 June 2007
Resolved 17 May 2007
Electrical › Electric Generation Source (service) › Generator
Issued 14 May 2007 Resolved
Investigate and repair the stbd SSDG, the gen has been reported to be tripping off line while under load.
Due 1 June 2007
Resolved 17 May 2007
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 14 May 2007 Resolved
Failure to comply with the requirements for vessel owners to pay fees before inspection or examination services are provided.
Action required: 705 - Other - as specified
Resolved 16 November 2007
Lifesaving › Inflatable Liferafts › Servicing
Issued 26 May 2006 Resolved
Provide copy of the four life raft servicing report to the e-mail address listed above. This item was converted to an ABS condition of class in accordance with NVIC 2-95.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 14 May 2007
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 26 May 2006 Resolved
Install life rafts and launching appliances that conform to SOLAS 74/78, Chapter III, Regulation 31.1.3.
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 14 May 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 26 May 2006 Resolved
Provide copy of the firefighting servicing report to the e-mail address listed above. This item was converted to an ABS condition of class in accordance with NVIC 2-95.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 14 May 2007
Communications › Alarms/Indicators › Fire Alarm
Issued 26 May 2006 Resolved
Prove proper operation of the smoke detector in the forward pilot house. This item was converted to an ABS condition of class in accordance with NVIC 2-95.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 14 May 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 May 2006 Resolved
Prove proper operation of all bilge alarms in engineering spaces.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2007
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 26 May 2006 Resolved
Prove proper operation of all lights on engineering main alarm panel. This item was converted to an ABS condition of class in accordance with NVIC 2-95.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 14 May 2007
Construction/Loadline › Structures › End Bulkhead
Issued 26 May 2006 Resolved
Adjust WTD leading to the engine room. This item was converted to an ABS condition of class in accordance with NVIC 2-95.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 14 May 2007
Communications › Alarms/Indicators › High Water Alarm
Issued 26 May 2006 Resolved
Prove proper operation of high water temp alarm on starboard MDE. This item was converted to an ABS condition of class in accordance with NVIC 2-95.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 14 May 2007
Communications › Alarms/Indicators › High Water Alarm
Issued 26 May 2006 Resolved
Prove proper operation of high water temp alarm on starboard SSDG. This item was converted to a condition of class in accordance with NVIC 2-95.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 14 May 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 May 2006 Resolved
Prove proper operation of oily water separator. This item was converted to an ABS condition of class in accordance with NVIC 2-95.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 14 May 2007
Communications › Radio Communications › EPIRB
Issued 13 May 2003 Resolved
Renew hydrostat on EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2003
Resolved 13 May 2003
Electrical › Electric Supply System (service)
Issued 13 May 2003 Resolved
Secure batteries located at 02-deck Engineering officer's office. LEGACY COMPONENT DESC: Battery Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2003
Resolved 13 May 2003
Lifesaving
Issued 5 June 2001 Resolved
REPLACE HYDROSTATIC RELEASE FOR EPIRB. VESSEL RESTRICTED TO 3NM UNTIL REPLACED.
Condition: Unknown
Due 5 July 2001
Resolved 7 June 2001
Fire Fighting
Issued 5 June 2001 Resolved
REPLACE FIREHOSE AND HYDRO TEST.
Condition: Unknown
Due 5 July 2001
Resolved 7 June 2001
Engineering
Issued 2 June 2000 Resolved
Periodically check and verify torque on port & stbd shaft couplings bolts and provide written report to attending marine inspector with lic officer signature and minimum of three (3) checks no later than 02JUL00.
Condition: Unknown
Due 2 June 2000
Resolved 2 June 2000

Casualty record · 2

15 April 2007Significant Marine Casualty · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 dead · activity 3120448
18 December 2008Routine · role: Subject to Marine Inspection · activity 3384422
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.