Inspection history · 34
13 November 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8267476
4 December 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8042719
9 September 2024
Internal Structural Exam · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7990170
20 November 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7822784
22 May 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7693993
11 May 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7686028
20 April 2023
Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7672085
17 November 2022
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7592069
22 November 2021
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7355961
15 March 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7156543
23 November 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7100275
2 October 2019
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6826209
2 October 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6826281
12 September 2019
Deficiency Check · In-Service Inspection · Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6811089
19 August 2019
Simplified Stability Test
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6789166
24 July 2019
Deficiency Check · Plan Review "T" Boat
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6809887
7 March 2019
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6661389
21 February 2019
Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6626651
31 August 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6528511
16 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6513771
15 August 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6512596
5 September 2017
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6259581
4 September 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6264382
15 August 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6228704
1 May 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6136576
27 April 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6133496
26 April 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6134135
8 February 2017
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6084497
13 August 2016
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5973729
12 August 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6024284
24 June 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5921042
21 June 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5922677
23 May 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5961792
16 May 2016
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5875370
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 November 2025
Resolved
Marine employers may form or otherwise use sponsoring organizations, or may use contractors, to conduct the random chemical testing programs required by this part. Vessels drug and alcohol program participation certificate was expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2025
Resolved 2 December 2025
Resolution: Re'vd updated certificate, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 November 2025
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals and Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter. Vessel was missing 02 orange smoke distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2025
Resolved 2 December 2025
Resolution: 02 smoke signals were replaced, sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 September 2024
Resolved
Cable and wire for power and lighting circuits must:
(2) Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable...Cables to navigation lights are not marine grade. Replace within 14 days.
46 CFR 183.340(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 23 September 2024
Resolution: Received objective evidence rectifying deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 September 2024
Resolved
IAW USCG DAPI Audit form and CFR, provide all required documentation and conduct training per separate correspondence within 14 days.
46 CFR 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 7 October 2024
Resolution: Recieved objective evidence to clear def.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 9 September 2024
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. MI observed light guard missing on the main deck starboard side overhead. Replace/repair within 14 days.
46 CFR 183.410(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 7 October 2024
Resolution: Recieved objective evidence to clear def.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 September 2024
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: SEE ON FOLLOWING PAGE OF 835...
(1) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.”.
(2) Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units.
(3) Spaces into which carbon dioxide might migrate—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. DISCHARGE INTO NEARBY SPACE CAN COLLECT HERE. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED VACATE IMMEDIATELY.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. Missing signage for CO2 system to be posted within 14 days.
46 CFR 185.612 (g)(1-3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 23 September 2024
Resolution: Received objective evidence rectifying deficiency.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2024
Resolved
A hatch cover must:(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. MI observed hatches not secured by chain. Repair/replace within 14 days.
46 CFR 179.360(b)(2)
Action required: 705 - Other - as specified
Due 24 September 2024
Resolved 23 September 2024
Resolution: Received objective evidence rectifying deficiency.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 20 November 2023
Resolved
All vessels shall be provided with bilge pumps IAW table 182.25-10(a). Power driven bilge pump in-op & hand pump absent
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2023
Resolution: Owner provided objective video evidence of the installed bilge pump dewatering a space, sat.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 20 November 2023
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Compass is not illuminated. Vessel restricted to daytime opperation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2023
Resolved 27 November 2023
Resolution: Owner provided objective video evidence of the magnetic compass illuminated, sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 November 2023
Resolved
Vessel must carry adequate and up to date charts. Update electronic charts or acquire up to date paper charts
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2023
Resolved 27 November 2023
Resolution: Owner provided objective evidence, a receipt that updated paper charts had been ordered, sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 April 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel didn't complete DDX/ISE inspection within the two year period. Inspection must be completed prior to carrying passengers.
46CFR176.600
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2023
Resolved 27 April 2023
Resolution: Completed Credit Dry Dock and Internal Structural Exam
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 November 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Vessel crew unable to drain water using bilge pump.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2022
Resolution: Witness satisfactory operation.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 22 November 2021
Resolved
EACH OFFICER EMPLOYED MUST HAVE HIS LICENSE ONBAORD AND AVAILABLE FOR EXAMINATION AT ALL TIMES VESSEL IS OPERATING. MASTERS LICENSE NOT ONBOARD.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2021
Resolved 29 November 2021
Resolution: Recieved valid PDF scan of master's valid license.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 November 2021
Resolved
EACH PORTABLE FIRE EXTINGUISHER MUST BE OF AN APPROVED TYPE. TYPE ARRPOVAL INCLUDES BRACKET. FOUR FIRE EXTINGUSHERS ON MAIN DECK NOT BRACKETED.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2021
Resolved 7 December 2021
Resolution: Verfied mounting for fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 November 2021
Resolved
PLACARDS CONTAING INSTRUCTIONS FOR THE DONNING AND USE OF LIFEJACKETS MUST BE POSTED IN CONSPICOUS PLACES. DONNING AND INSTRUCTIONS NEEDED ON MAIN AND UPPER DECK.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2021
Resolved 7 December 2021
Resolution: Verified posting of instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 November 2021
Resolved
THE NUMBER AND IDENTIFICATION OF ITEMS STOWED INSIDE MUST BE MARKED FOR LIFEJACKET CONTAINERS. CHILD-SIZE LIFEJACKETRS NOT LABALED.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2021
Resolved 7 December 2021
Resolution: Verified installation of identification.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 July 2019
Resolved
Vessel altered its fixed CO2 system and must install an odorizing unit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 August 2018
Resolved
The vessel is currently broadcasting (1) Improper Call Sign, (2) Improper Name
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2018
Resolved 23 November 2020
Resolution: VSL owner initiated AIS transmission and radioed nearby VSL to confirm AIS was reading VSL’s name. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2018
Resolved
Vessel should not have exhaust gas leaking from the piping or any connections. Repair source of exhaust gas leak to the satisfaction of a coast guard marine inspector.(46CFR182.15-20(a))
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2018
Resolved 23 November 2020
Resolution: Attending MI ran machinery during initial COI inspection, no Exhaust leaks noted
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 15 August 2018
Resolved
Vessel was unable to perform man overboard drill due to unsafe condition developing in the machinery space. (46CFR176.808(g))
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2018
Resolved 23 November 2020
Resolution: Attending MI witnessed VSL crew perform successful man overboard recovery during initial COI inspection.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2018
Resolved
Vessel is required to have spanner wrenches at fire hose station. Provide spanner wrenches at fire hose station. (46CFR181.310(d))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2018
Resolved 23 November 2020
Resolution: Spanner wrench mounted on fire hydrant all SAT.
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 5 September 2017
Resolved
STBD shaft coupling lost oil pressure and failed, leading to loss of propulsion on STBD engine. USCG MIs must witness satisfactory testing after technician completes maintenance and repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2017
Resolution: Received technician report attesting to satisfactory repairs to include replacement of a gasket on the lube oil pump. Conducted underway sea-trial, all sat.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 1 May 2017
Resolved
Vessel's port propeller shaft seal is not sealing as required/intended. Provide technician's report from the manufacturer that the shaft seal has been installed correctly per the manufacturer's instructions to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2017
Resolution: CGMI witnessed satisfactory operation of newly installed shaft seal system.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 26 April 2017
Resolved
When repairs are made during an emergency, the operator shall notify the OCMI as soon as practicable after such repairs are made. Vessel's port propeller shaft mechanical seal came loose while carrying passengers resulting in flooding of watertight compartment. Vessel may not carry passengers until satisfactory repairs are made to the satisfaction of the attending CGMI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2017
Resolved 27 April 2017
Resolution: Manufacturer specifications were provided to [name withheld] of shaft seal was made in accordance with manufacturer's specifications.
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 15 August 2016
Resolved
Bridge control failed to engage fwd/astern propulsion, vessel must have control of shaft rotation. Conduct repairs to satisfaction of attending CG MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2016
Resolution: Tech rep replaced port & stbd electro mechanical propulsion control units. MI witnessed a successful U/W trial of propulsion control system; all sat.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 21 June 2016
Resolved
Excessive oil in engine room bilge. Vessel is restricted from operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2016
Resolution: Inspected engine room bilge, excessive oil had been removed from bilge; all sat.
Construction/Loadline › Structures › Superstructure
Issued 21 June 2016
Resolved
Hole in watertight hatch on bottom of portside of stairs is allowing water to enter into engine room. Vessel is restricted from operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2016
Resolution: Inspected soft patch under stairs, new rubber gasket installed bedded with 3M 5200 marine sealant; all sat.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 16 May 2016
Resolved
Bilge in engine room had excessive oil. Clean to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 22 May 2016
Resolved 24 June 2016
Resolution: excessive oil had been removed from bilge; all sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2016
Resolved
Starboard engine alternator missing guard. Add guard.
Action required: 705 - Other - as specified
Due 22 May 2016
Resolved 21 June 2016
Resolution: Cleared by [name withheld] during def check - Activity #5922677.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2016
Resolved
Electrical wire in engine room were secured with zip ties. Secure with metal supports
Due 15 June 2016
Resolved 21 June 2016
Resolution: Cleared by [name withheld] during def check - Activity #5922677.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 May 2016
Resolved
Light bulb in space under pilot house was uncovered. Cover bulb with guard.
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 21 June 2016
Resolution: Cleared by [name withheld] during def check - Activity #5922677.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2016
Resolved
There were dead end wires in space below pilot house. Remove or cap dead end wires.
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 21 June 2016
Resolution: Cleared by [name withheld] during def check - Activity #5922677.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 16 May 2016
Resolved
Electrical box in space below pilot house was not mounted against bulkhead. Secure electrical box.
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 21 June 2016
Resolution: Cleared by [name withheld] durign def check - Activity #5922677.
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 16 May 2016
Resolved
83 life jackets had deteriorated retro reflective material.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2016
Resolved 16 May 2016
Resolution: Operator replaced all life jackets prior to the end of the inspection. Corrected on the spot.