USNS SGT. WILLIAM R. BUTTON

USNS SGT. WILLIAM R. BUTTON is a 1986 freight ship. The Coast Guard has recorded 39 inspections since 2016, most recently in April 2026, along with 84 deficiencies and 3 casualty investigations between 2005 and 2021.

Records from 2005 to 2026. Most recent: inspection, 2 April 2026.

Built
1986
Last inspected
2 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8302466
267947
Flag
UNITED STATES
Maury page id
psix-267947

Documentation record

Tonnage as PSIX records it32903 - Regulatory (Subpart C or D), Gross Ton
44543 - Convention (Subpart B), Gross Ton
25384 - Regulatory (Subpart C or D), Net Ton
14461 - Convention (Subpart B), Net Ton
26949 - Dead Weight, Ton
4611 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 39

2 April 2026 ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8373105
4 August 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8202388
29 March 2024 Administrative Inspection · ACP Drydock Oversight · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7886953
26 July 2023 Deficiency Check · ACP COI Oversight · Administrative Inspection · ACP Drydock Oversight · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7753106
23 June 2023 Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7733375
17 January 2023 ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7625338
13 September 2022 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7561527
1 March 2022 Administrative Inspection · ACP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7403575
14 January 2022 Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7380307
5 December 2021 Administrative Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7362901
4 December 2021 Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7363670
6 September 2021 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7326786
3 September 2021 Administrative Inspection · ACP Additional Oversight – Risk Assessment
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7303143
20 August 2021 Administrative Inspection · Underwater Inspection in lieu of Drydock
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7293927
8 July 2021 Administrative Inspection · Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7578538
1 June 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7321225
31 March 2021 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7166170
25 March 2021 Explosive Handling Operation-Military
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7162745
22 December 2020 Periodic Inspection · Special · ACP Additional Oversight – Risk Assessment · Administrative Inspection · ACP Periodic Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7120291
3 September 2020 ACP Drydock Oversight · In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7049258
2 June 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6966790
12 February 2020 Annual Inspection · Deficiency Check · ACP Annual Oversight · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6907533
4 November 2019 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7057472
16 October 2019 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7057458
26 August 2019 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6798793
26 August 2019 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6798795
2 April 2019 Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6659772
20 March 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6647335
1 October 2018 Examination of Repairs · Administrative Inspection · Damage Survey · ACP COI Oversight · Special · Underwater Inspection in lieu of Drydock · ACP Drydock Oversight · Deficiency Check · Re-Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6567809
20 July 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6485432
5 June 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6448566
23 May 2018 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6646297
27 March 2018 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6379695
24 February 2018 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6347509
20 June 2017 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6181181
6 June 2017 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 6151245
30 March 2017 Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6114134
16 May 2016 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5878576
19 February 2016 MTSA/ISPS Verification · Administrative Inspection · ACP COI Oversight · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5818217

Deficiency record · 84

07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 August 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: penetrations in fire-resisting divisions. The fire dampers needing repairs as listed in the Global Fire and Safety report dated 23Feb25 were inoperable. Repair fire dampers and verify all fire doors were adjusted accordingly. SOLAS II-2 Reg 14.2.1.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2025
Resolved 24 March 2026
Resolution: RO verified all dampers and doors operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 March 2024 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. While conducting sea trails, after a dry-dock period, the vessel had a main space fire, in which the propulsion was lost, and the CO2 system was activated to extinguish the fire. A repair proposal must be provided, the CO2 system serviced, and repairs must be made to the satisfaction of ABS and the Coast Guard.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2026
Resolution: Repairs complete. All Statutory Surveys Endorsed. Annual Inspection Complete.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 February 2023 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. On page 17, of Hiller System’s inspection report Job # VG1058, dtd 2/9/2023, 10% of the smoke detectors in Zones 20 and 25 were marked unsatisfactory. Conduct a sample test of smoke detectors in Zones 20 and 25 to the satisfaction of the attending Class surveyor.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 10 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 February 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The following bunks with lifejackets were found with a discrepancy: Bunks 17, 18, 35, 45 and 52 with reflective tape deteriorated/pealing off jacket, Bunk 10: Replace lifejacket with mold with new, Bunk 66: Replace torn lifejacket with new.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 10 March 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Excessive oil observed in the galley exhaust vent and on fusible link. Remove excessive oil and maintain to prevent further build up of oil.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 10 March 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 February 2023 Resolved
Electrical installations shall be such that electrical services essential for safety will be ensure under various emergency conditions. Emergency lights in surge room are inoperable. Repair and prove operation of emergency lights in surge room.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 10 March 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 February 2023 Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. Replace missing fire stop in cable penetration on upper deck on forward gas tight bulkhead between ER and pump room.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 10 March 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 February 2023 Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. Replace missing fire stop/stuffing in cable penetration in Electronic Equipment Room in way of interior stairs leading to the bridge/wheelhouse.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 10 March 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 February 2023 Resolved
All required fire detection systems shall be capable of automatically indicating the presence or indication of fire and also its location. The heat detector in the incinerator room was not operable at the time of inspection.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 17 April 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 February 2023 Resolved
An alarm system shall be provided indicating any fault requiring attention and shall: be capable of sounding an audible alarm in the main machinery control room or at the propulsion machinery control position, and indicate visually each separate alarm function at a suitable position. The high oil temperature and air valve open visual indicators for the emergency generator local alarm panel are extinguished.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 10 March 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 February 2023 Resolved
Each circuit directory must (ii) A description of the load of each circuit; and (iii) The rating or setting of the overcurrent protective device for each circuit. Amperage on the electrical cardholder for No. 22P4554, MIPCO #2, in Panel P445 (1) 460 Volt located in the Machine Shop does not match the amperage referred to on the breaker. Verify rating or setting of the overcurrent protective device for each equipment is properly matched to the circuit breaker panel.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 10 March 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Repair forward bosun hatch cover to as original with missing metal edge in way of hinge pad.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 17 April 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 February 2023 Resolved
The items contained in first-aid kit shall be as listed in Table 160.041-4(b). Multiple expired medicines in the hospital medicine chest. Replace with new.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 10 March 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 27 February 2023 Resolved
Oil filtering equipment shall comply with paragraph 6 of this regulation. The Re-circulating facilities should be so configured as to prevent under all operating conditions any by-pass of the oily-water separator. Re-circulating facilities do not meet the requirements of MEPC 107(49)/6.1.1 and as installed allows for the by-pass of the oily water separator through the sampling point. Provide plans for approval prior to the modification of the piping arrangement.
Action required: 705 - Other - as specified
Due 31 March 2023
Resolved 10 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 February 2023 Resolved
Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. Main engine test procedure 1.3, engine overspeed does not provide proper direction for conducting the automation test as the engine monitoring/control system has been upgraded since the test procedures approval on September 6, 2018.
Action required: 705 - Other - as specified
Due 31 March 2023
Resolved 10 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 27 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Effect permanent repairs to leaking pipes with multiple soft patches in the overhead above the battery re-charging station in the Battery Room.
Action required: 705 - Other - as specified
Due 31 March 2023
Resolved 17 April 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 January 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Repair and secure leak from JP5 sampling line in pump room.
Action required: 705 - Other - as specified
Due 17 March 2023
Resolved 17 April 2023
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 2 March 2022 Resolved
The ventilation systems of cargo ships shall be in compliance with the provisions of regulation 16, except paragraph 8. Replace missing exhaust cover in AB’s washroom and in storage supply room located on same deck as MCMC offices.
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 17 April 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Repair wasted electrical cable penetration on GCC K bulkhead on main deck to as original and to prevent chaffing to cable.
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 17 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 2 March 2022 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Replace emergency pull cable on port side lifeboat No. 2 with new in accordance with OEM’s procedures. When lowering life boat the emergency cable fouls up and is cutting into the limit switch cable for the davit arm.
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 17 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
All electrical apparatus shall be constructed and so installed that danger or injury in ordinary handling shall not exist. The starboard #1 steering gear’s power control knob is inoperable and cannot be de-energized unless opening the controller box.
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 22 August 2022
Resolution: Class Finding #1427.0 - Uploaded to Documents.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
All electrical apparatus shall be constructed and so installed that danger or injury in ordinary handling shall not exist. The electrical controller cabinet door’s hinges in bow thruster space is broken and will not close.
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 17 June 2022
Resolution: Class Finding Number: 1428.0 - uploaded to Documents.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 2 March 2022 Resolved
The survey shall be such as to ensure the arrangements, materials, and scantling of the structure, boilers, and other pressure vessels and their appurtenances, main and auxiliary machinery, electrical installations and other equipment are in all respects satisfactory for the service which the ship is intended. The oily water separator’s discharge pipe has a small corrosion and weeping.
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 17 April 2022
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 2 March 2022 Resolved
The survey shall be such as to ensure the arrangements, materials, and scantling of the structure, boilers, and other pressure vessels and their appurtenances, main and auxiliary machinery, electrical installations and other equipment are in all respects satisfactory for the service which the ship is intended. The bow thruster’s space WTH (located on the focsle) inner support frame/stiffener is holed and wasted.
Action required: 705 - Other - as specified
Due 30 April 2022
Resolved 17 April 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Remove saturated sorbent pads with hydraulic oil and clean oil residue on deck in bow thruster room. Deck must be kept free oil spillages and maintained to prevent potential slips, trips, falls and fires.
Action required: 10 - Deficiency Rectified
Due 12 March 2022
Resolved 10 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Reroute extension cable in way of entrance on main deck for dehumidifier in the No.1 damage control locker in bow thruster room to prevent potential electrical hazard and tripping.
Action required: 10 - Deficiency Rectified
Due 12 March 2022
Resolved 10 March 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Replace missing light fixture in way of entrance and replace broken protective glass on third light fixture in No. 1 damage control locker in bow thruster room.
Action required: 10 - Deficiency Rectified
Due 12 March 2022
Resolved 10 March 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Remove build up grease and debris underneath/around electrical cooking appliances in galley to prevent potential fire hazard.
Action required: 10 - Deficiency Rectified
Due 12 March 2022
Resolved 10 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2022 Resolved
Multiple ring buoy with light attached inspected with lines that are 2 ft or less in length. Replace lines attached with a light are 2ft in length. Replace with new with a minimum length of 3ft but no more than 6ft in length.
Action required: 10 - Deficiency Rectified
Due 12 March 2022
Resolved 10 March 2022
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 March 2022 Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. Replace missing fire stops in cable penetrations in KBR and low pressure CO2 room with new.
Action required: 10 - Deficiency Rectified
Due 12 March 2022
Resolved 10 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2022 Resolved
Lifejackets shall be so placed as to be readily accessible and their positions be plainly indicated. PFDs and immersion suits for mission support personnel must be stowed in designated locations per vessel’s approved safety/fire control plan. PFDs and immersion suits are consolidated together in marked storage room designated for immersion suits only. Remove PFDs from immersion suit storage and relocate to designated location marked PFDs. Remove tools and debris in PFD designated storage compartment to prevent damage to PFDs and to allow for easy accessibility. Provide letter from 3rd Mate attesting that each PFD and immersion suit has been checked and in satisfactory condition with light, whistle, etc. per SOLAS are attached. Provide documentation of last inflation test for immersions suits.
Action required: 10 - Deficiency Rectified
Due 12 March 2022
Resolved 10 March 2022
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 2 March 2022 Resolved
The purpose of this regulation is to contain a fire in the space of origin. For this purpose, the following functional requirements shall be met: the fire integrity of the divisions shall be maintained at openings and penetrations. Repair fire damper 01-209-2 for A/C SYS 1-235-2 with opening/cut out in ducting to as original to prevent passage of smoke into the passage way.
Action required: 10 - Deficiency Rectified
Due 12 March 2022
Resolved 10 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 6 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea without danger to the ship or persons on board. Repair to as original design modified manhole cover from cargo ventilation to electrical panel in starboard side GCC space on the main deck. It draws excessive precipitation and potential hazardous flammable gas inside the protected weather protected space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2021
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 6 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea without danger to the ship or persons on board. In the EDG ventilation trunk there are 2 manhole covers and on one of them there are missing 6 bolts.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 September 2021 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. Prove operation of Fire Damper 04-224-1; A/C SYS 03-235-2.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2021
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 6 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. Missing wheel handle nut on overboard discharge valve. Replace missing nut on wheel handle to as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 6 September 2021 Resolved
The main steering gear and rudder stock must be capable of moving the rudder from 35° on either side to 35° on the other with the vessel at its deepest loadline draft and running at maximum ahead service speed, and from 35° on either side to 30° on the other in not more than 28 seconds under the same conditions. Prove operation of ship's main steering in wheelhouse is capable to place the rudder hard over left (35 deg.) via hand mode using No. 2 steering pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 September 2021 Resolved
Containers, brackets, racks, and other similar stowage locations for lifesaving equipment shall be marked with symbols in accordance with the recommendations of the Organization, indicating the devices stowed in that location for that purpose. Missing IMO reflective placards for ring buoys on main deck (port/starboard side).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 September 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Replace O-rings/shackles with excessive corrosion/wastage on lifeboat embarkation ladders on main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea without danger to the ship or persons on board. Replace missing covers on lamps on Smoke Detection panel in Fire Detection Room on 63 Level. Per Smoke Detection System placard on bulkhead states "blue lights" indicate trouble however the Smoke Detection panel shows red and yellow only. Update per manufacturer's procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2021 Resolved
The items contained in first-aid kit shall be as listed in Table 160.041-4(b). Replace expired medical equipment inside the medical box in the forward bow void.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea without danger to the ship or persons on board. Repair audible alarm/siren separated from bracket in Cargo Hold No. 4.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 September 2021
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 September 2021 Resolved
The following basic principles underlie the regulations in the regulations having regard to the type of hazard involved: containment and extinction of any fire in the space of origin. Repair to as approved construction Class-A door to KBR on 63 Level inspected with holes to prevent passage of smoke/flames.
Action required: 10 - Deficiency Rectified
Resolved 9 September 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 September 2021 Resolved
The following basic principles underlie the regulations in the regulations having regard to the type of hazard involved: containment and extinction of any fire in the space of origin. Replace missing fire stop sealant in the following cable transits: upper flat in forward bow in way of ladder well, above KBR door on 63 Level, and in way of Battery Shop on 63 Level.
Action required: 10 - Deficiency Rectified
Resolved 9 September 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea without danger to the ship or persons on board. Repair electrical cable for security light on starboard side main deck aft of lifeboat/rescue boat; verify proper connection of electrical cables for other security lights on main and replace unapproved electrical cables with USCG approved marine grade.
Action required: 10 - Deficiency Rectified
Resolved 9 September 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 September 2021 Resolved
Electrical installations shall be such that electrical services essential for safety will be ensure under various emergency conditions. Prove operation of Emergency Lights in all Cargo Holds and interior ladder in house.
Action required: 10 - Deficiency Rectified
Resolved 9 September 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 September 2021 Resolved
Electrical installations shall be such that electrical services essential for safety will be ensure under various emergency conditions. Prove operation of exterior house lights including E lights; multiple exterior lights tested inoperable.
Action required: 10 - Deficiency Rectified
Resolved 9 September 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea without danger to the ship or persons on board. Repair ventilation cover with wastage on container located on aft main deck where incinerator is housed inside.
Action required: 10 - Deficiency Rectified
Resolved 9 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to sea without danger to the ship or persons on board. Auxiliary Boiler No. 1 with temporary repair, backing strips on the exterior shield, for Class approval. Attending Surveyor verified no repairs were made to Aux Boiler No. 1 and backing strips were removed.
Action required: 10 - Deficiency Rectified
Resolved 9 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 December 2020 Resolved
On cargo ships of 20,000 gross tonnage and upwards, lifeboats shall be capable of being launched, where necessary utilizing painters, , with the ship making headway at speeds up to 5 knots in calm water. Lifeboats number 1 failed required 5 knot release test. Lifeboats 1 and 2 are removed from service. Prove proper operation of 5 knot test release on #1 lifeboat in the presence of USCG Marine Inspectors and RO. Vessel must conduct drill/training to ensure crew is aware of lifeboat availability. Maximum of 73 Persons can be carried. Make repairs and demonstrate proper operation to attending RO.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 19 February 2021
Resolution: Witnessed sat release test.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 December 2020 Resolved
Every oil fuel daily service tank situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space. Reach rod for emergency diesel generator daily tank is broken and not capable of securing valve in an emergency from outside the space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 19 February 2021
Resolution: Witnessed proper operation of fuel oil cut off valve from outside space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 December 2020 Resolved
Measures shall be to the satisfaction of the Administration to ensure the equipment is functioning in a reliable manner and that the arrangements are made.for routine test to ensure continuous reliable operations. Vessel failed to demonstrate proper testing of vital machinery systems in accordance with approved testing procedures. Vessel's engineering staff required to review completed testing procedures to automation for years 2020/2021 and repeat tests not performed to approved procedures.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 19 February 2021
Resolution: Reviewed PSTP with [name withheld] testing performed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 December 2020 Resolved
Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with Resolution A.760(18), AM. indicating the devices stowed in that location. If more than one device is stowed in that location, the number of devices shall also be indicated. IMO markings are missing from all life saving stowage locations on the exterior of the vessel. Properly mark lifesaving stowage locations to the satisfaction of the RO.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 19 February 2021
Resolution: IMO stickers put in place
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 22 December 2020 Resolved
An International Tonnage Certificate (1969) shall be issued to every ship, the gross and net tonnages of which have been determined in accordance with the present convention. Vessel must have a valid Tonnage Certificate meeting the requirements referenced in ANNEX II of the convention. Provide on board to the satisfaction of the Administration.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 31 March 2021
Resolution: Tonnage Certificate provided.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 14 December 2020 Resolved
A general emergency alarm system complying with the Code, shall be provided. General alarm bell in Cargo hold #2 B-Deck 1 of 2, Cargo hold #3 F-deck 3 of 4, 63 foot level passageway outside sheet metal workshop and A-deck cross passageway outside of galley port door are inoperable. Repair/replace inoperable alarms within 30 days, but not later then departure from scheduled shipyard availability in Charleston, SC.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2020
Resolved 16 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 14 December 2020 Resolved
Survival craft launching appliances shall meet the Code. During launching of the port side aft 73 person survival craft/rescue boat, it was noted that the cable for launching control from within the craft bird-nested at the drum and the vessel did not lower all the way to the water.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2020
Resolved 16 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 December 2020 Resolved
Perform Fire and Abandon ship drills to the satisfaction of attending Coast Guard inspector prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
08 - Alarms › N/A - No Subsystem › General alarm
Issued 21 February 2020 Resolved
46 CFR 113.25-9(b):General alarm (GA) signal must be audible in the spaces identified in paragraph (a) of thi sseciton with all normally closed doors and accesses closed. Repair GAs in the following locations/spaces listed below and prove proper operation of GAs to the attending USCG MI: cargo holds 2, 3 and 4, bottom flat in forward bow thruster room, sheet metal shop on Level 63, in passageway of EDG room, and near galley entrance.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 March 2020
Resolution: ABS report dtd 15AUG2020 attached under Deficiencies Documents.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 February 2020 Resolved
74SOLAS(81)CHPT III, Reg. 19.2: Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Replace unapproved and expired battery for bouyant light attached to ring buoys with new per manufacturer's specifications.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2020
Resolution: New batteries per manufacturer specs were installed and verified by the attending MI.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 21 February 2020 Resolved
74SOLAS(81) CHPT II-1, Reg. 38: An engineer's alarm shall be provided to be operated from the engine control room or at the maneuvering platform as appropriate, and shall be clearly audible in the engineer's accommodation. Prove proper operation of engine room alarms (audible and light).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2020
Resolution: Repaired and tested to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 February 2020 Resolved
74SOLAS(81)CHPT III, Reg.19.2: Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Repair port and starboard lifeboat embarkation ladder supports with wastage on main deck and hardware with wastage with new at lifeboat embarkation stations 3, 4 and 5, to the satisfaction of Classification Society.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 February 2020 Resolved
74 SOLAS (81) CHPT III, Reg. 11.4: Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of the electrical power required by regulation II-1/42 or II-1/43, as appropriate. Repair port embarkation exterior light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2020
Resolution: Repaired and tested to the satisfaction of the attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 21 February 2020 Resolved
74SOLAS(81) CHPT III, Reg. 8.4: Illustrations and instruments in appropriate languages shall be conspicuously displayed at muster stations and other passenger spaces to inform passengers of: their muster stations, the essential actions they must take in an emergency, and method of donning lifejackets. Missing IMO symbols at port and stbd lifeboat muster stations IAW organization.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2020 Resolved
74SOLAS(81) CHPT II-1, Part C, Reg. 26: The machinery, boilers, and other pressure vessels associated piping system and fittings shall be of design and construction adequate for the service whence they are intended. Repair/reconnect reach rod on ballast line in emergency fire pump/bow thruster room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2020
Resolution: Reconnected and reach rod exercised to the satisfaction of attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Communication-SOLAS chap. 5
Issued 21 February 2020 Resolved
74SOLAS(81), CHPT I, Part B, Reg. 11: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea. Repair sound power phone on bow and prove operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 21 February 2020 Resolved
74SOLAS(81) CHPT II-2, Part A, Reg. 20: In all ships general arrangement plans shall be permanently exhibited for the guidance for the ship's officers, showing clearly each deck the control stations...together with the particulars of the fire detection and fire alarm systems. Update vessel's fire control plan to reflect optical smoke detector in crew laundry-A Deck, to the satisfaction of the Classification Society. Crew to also verify against approved FCP with recent report of annual firefighting inspection with spaces tested with heat/smoke detectors and submit findings to USCG and Class.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2020
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 February 2020 Resolved
74SOLAS(81) CHPT II-2, Part A, Reg. 21: In all ships fire extinguisher appliances shall be kept in good order and available for immediate use at all times during voyage. Replace portable fire extinguisher with expired inspection tag dated 2018, in EDG room with a recently inspected and ready for use portable fire extinguisher.
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 21 February 2020 Resolved
74SOLAS(81) CHPT I, Part B, Reg. 11: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea w/o danger to the ship or persons on board. Replace missing guard on electric fan coil heater in the bow thruster room.
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2020 Resolved
74SOLAS(81) CHPT I, Part B, Reg. 11: Replace missing non-conductive electrical matting for high voltage electrical switch boards in forward bosun locker.
Action required: 10 - Deficiency Rectified
Resolved 27 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 August 2019 Resolved
Vessel in port when ship crew discovered mechanical failure to the Stbd Main Engine no. 6 intake valve.
Action required: 705 - Other - as specified
Resolved 26 August 2019
Deck/Cargo › Holds/Tanks › Ventilation Exhaust Outlet
Issued 24 February 2018 Resolved
Inspect all cargo hold ventilation dampers to ensure they seal properly. Make permanent repairs as needed to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 1 March 2020
Resolved 23 March 2018
Resolution: ABS inspected 20% of all Cargo Hold Ventilation dampers examined, operationally tested, and found to be in satisfactory condition. Outstanding COC for all Dampers to be further examined and operationally tested at the next DDX
Engineering › Sea-water System (primary cooling) › Pump
Issued 24 February 2018 Resolved
SW cooling pump in bow thruster room is leaking. Make permanent repairs to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: Cooling pump was overhauled by crew and tested sat by ABS
Construction/Loadline › Structures › Machinery Space Opening
Issued 24 February 2018 Resolved
Forward forepeak cargo access hatch is not watertight. Make permanent repairs to restore integrity of the boundary to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: Hatch readjusted and tested sat by ABS
Construction/Loadline › Structures › Scuttle
Issued 24 February 2018 Resolved
Scuttle for fore peak tank is wasted and gasket is missing. Securing mechanism is missing bolts and does not properly seal hatch. Make permanent repairs to restore integrity of the boundary to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: Hatch readjusted and tested sat by ABS
Deck/Cargo › Ballast › Valves
Issued 24 February 2018 Resolved
Ballast system remote rods for emergency shut off are missing T-handle. Make permanent repairs to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: Missing T handles installed by crew and tested sat by ABS
Construction/Loadline › Structures › Deck Plating
Issued 24 February 2018 Resolved
Cargo Hold #4 Ventilation Port Side has multiple wasted wire run stuffing tubes through the deck. Make permanent repairs to restore integrity of the boundary to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: Stuffing tubes renewed and examined sat by ABS
Construction/Loadline › Structures › Deck Plating
Issued 24 February 2018 Resolved
Sound powered phone port side by accommodation ladder stuffing tube is wasted. Make permanent repairs to restore integrity of the boundary to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: Studding tube renewed and examined sat by ABS
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 February 2018 Resolved
Bow Thruster room forward near emergency fire pump has multiple dead-end wires. Make permanent repairs to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: All dead end wires removed and/or properly dead-ended, examined sat by ABS
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 February 2018 Resolved
On A-Deck: Junction box is missing screws and explosion proof light is missing plug, repair or replace with approved equipment. Make permanent repairs to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: Junction box adjusted and examined sat by ABS
Construction/Loadline › Structures › Ventilators
Issued 24 February 2018 Resolved
Fore peak tank ventilation fan is not properly secured. Properly mount fan. Make permanent repairs to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: Fan properly secured by crew, examined sat by ABS
Deck/Cargo › Ballast › Piping
Issued 24 February 2018 Resolved
Pipe supports throughout cargo holds are missing, bent, or broken. Make permanent repairs to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: All pipe supports throughout cargo holds replaced by riding crew, examined sat by ABS.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 February 2018 Resolved
Retroreflective on life jackets is not approved. Make permanent repairs to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: Outstanding condition of class created to be replaced on/by 26MAY18
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 24 February 2018 Resolved
Form E has multiple pen and ink changes that are not signed or endorsed. Attending ACP ACS to review and correct form.
Action required: 705 - Other - as specified
Due 24 March 2018
Resolved 23 March 2018
Resolution: Form E updated and reissued
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 24 February 2018 Resolved
Planned Maintenance Program onboard documentation is not available as required by ABS Rules Part 7.14.13.5. Provide required onboard documentation to the satisfaction of the attending ACP ACS.
Action required: 705 - Other - as specified
Due 24 August 2018
Resolved 23 March 2018
Resolution: PMP reviewed with CHENG, [name withheld] confirmed, vessel status corrected accordingly. Annual report per ABS PMP rules provided and reviewed by ABS. Considered all sat by ABS

Casualty record · 3

1 April 2005Routine · role: Involved in a Marine Casualty · activity 2325810
31 March 2021Routine · role: Involved in a Marine Casualty · activity 7166170
4 December 2021Routine · role: Involved in a Marine Casualty · activity 7363670