PAPPY'S LADY
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG East District (CGD-E) · Other hulls named PAPPY'S LADY
PAPPY'S LADY is a 1986 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1986, most recently in June 2026, along with 158 deficiencies — 1 with no resolution recorded — and 1 casualty investigation in 2009.
Records from 1986 to 2026. Most recent: inspection, 23 June 2026.
- Built
- 1986
- Last inspected
- 23 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 158 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2009
Identity
698178
WDJ6070
267969
Flag
UNITED STATES
367794050
Maury page id
psix-267969
Inspections, by type
…with no type recorded3
Years with a record
36 calendar years (1986–2026)
The 65 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 18.5 ft × 8.5 ft
Registered tonnagegross 63 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSLEEPY CREEK BOAT WORKS · MARSHALLBERG, NC, UNITED STATES · built 1986
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLEWES, DE
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 7 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Simplified, Gross Ton
50 - Simplified, Net Ton
50 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ6070MMSI 367794050 · active · compulsorily equipped · granted 10 June 2017, expires 10 June 2027
WDH3864MMSI 367611720 · expired · compulsorily equipped · granted 25 March 2014, cancelled 25 May 2024
WDB6026MMSI 366916530 · expired · compulsorily equipped · granted 18 December 2003, cancelled 22 February 2014
WTZ2045MMSI not assigned · expired · compulsorily equipped · granted 1 December 1995, cancelled 6 May 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 65
23 June 2026
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8391002
2 September 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8218488
21 March 2025
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8097424
17 September 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8004488
19 September 2023
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7791708
20 March 2023
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7650932
21 September 2022
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7555204
6 June 2022
Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7477568
23 June 2021
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7232067
14 June 2021
Simplified Stability Test
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7227480
17 August 2020
Plan Review "T" Boat · Deficiency Check · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7048645
3 June 2020
Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6975305
29 October 2019
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6844275
21 May 2019
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6689530
8 November 2018
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6577115
9 June 2017
In-Service Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6208596
18 April 2017
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6127074
8 August 2016
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5965869
4 June 2014
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4880449
20 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4228612
27 March 2009
Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3442572
5 June 2008
COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3227826
8 May 2007
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2924921
23 March 2007
Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2892861
8 May 2006
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2645962
8 December 2005
Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2548302
2 June 2005
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2451190
29 March 2005
Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2324607
3 June 2004
Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2087578
23 June 2003
Hull Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1824592
23 June 2003
COI Inspection · Deficiency Check
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1840833
28 November 2001
Annual Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1444649
18 April 2001
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1373584
20 April 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1437706
5 April 2000
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1452659
12 May 1999
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1397164
19 October 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 801546
17 June 1998
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1130088
24 April 1998
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 789623
10 April 1998
Hull Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1451284
22 April 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1092541
23 May 1996
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 870743
3 May 1996
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1088091
7 April 1995
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1144744
2 August 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 865744
19 April 1994
Re-Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 857887
12 April 1994
Hull Examination · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 857780
6 May 1993
Re-Inspection · Drydock Extension · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1362821
30 April 1992
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1258203
28 April 1992
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 946478
19 August 1991
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1250724
6 June 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 931997
15 October 1990
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 919732
21 March 1990
Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 916287
2 May 1989
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1353028
12 April 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1199679
7 April 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888386
5 May 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1347509
27 November 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1028416
23 September 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1315491
3 June 1987
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1331545
9 July 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 989938
18 June 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 989935
13 May 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1303218
8 May 1986
Initial Certification · Initial Construction-Excluding Oversight · Credit Drydock
Physical examination · THE UNKNOWN UNIT · Activity 1304111
Deficiency record · 158
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 1 July 2026
No resolution recorded
VSL's must comply with radio req'ts for station license. Single side band radio does not have an approved inspection from a licensed FCC inspector. Vsl restricted to operating with in 20-miles from shore. 46CFR184.502
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 June 2026
Resolved
Vessel's shall carry sufficient life floats for all persons on board. Vessel's life float light batteries are expired. Life float has cuts that require servicing and or replacement. 46CFR180.10-5
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2026
Resolved
Placards required for life jacket donning instructions are required to be conspicuously posted. Missing donning instructions for each type of life jacket on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 June 2026
Resolved
An approved life preserver available on board for each person carried. 08 adult life jackets need repair/replacement. 46CFR181.25-5
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 23 June 2026
Resolved
Stability information must be provided to the master. Stability letter not present on the bridge during inspection. 46CFR178.210
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 23 June 2026
Resolved
Vessel shall be maneuverable, arranged and equipped to allow crew to recover a helpless person. Captain was unable to sufficiently maneuver vessel in adequate time to retrieve the mannequin. Platform used for MOB retrieval was not adequate for the water rescue operation witnessed this day. 46CFR180.210
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 June 2026
Resolved
Electrical shall be to the satisfaction of [name withheld] ground worn in laz and tank room. Loose ground id'd in laz and tank room, and loose cable at the generator. 46CFR183.01-15
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 June 2026
Resolved
Electrical installations shall meet codes and recognized marine practices incorporated in this reference. Electrical outlet in forward rod room missing cover plate. 46CFR183.01-15
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 23 June 2026
Resolved
Steering shall be inspected and tested for condition and fit for service intended. Steering ram attachment compromised. Requires permanent attachment. 46CFR176.25-35
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2026
Resolved
Propulsion machinery shall be suitable and capable of operating at constant marine load. Cooling water leak on STBD engine. Excessive water spray on port/stbd engine shaft packing. 46CFR182.05-1
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 June 2026
Resolved
A self priming power driven fire pump required on board. Port engine PTO pump discharge pipe utilized a flex hose at a bend. Flex hose is creased in excess of 25% and reducing water output. 46CFR181.300
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 June 2026
Resolved
At each inspection the MI shall examine the bilges for accumulation of oil or other fire risks. Clean up and remove oil from E/R machinery and bilge space. 46CFR176.25-50
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 June 2026
Resolved
Hatches exposed to the weather must be watertight. Deck hatch at forepeak and laz both need gasket re-seated in the channel groove to make watertight. 46CFR179.360
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 September 2025
Resolved
At each inspection special attention shall be paid to ensure no fire hazards are present. Generator had pooled oil under it in its pan. Clean oil, identify source and secure. 46CFR176.25-10
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 September 2025
Resolved
Special attention shall be paid to ensure fire hazards are not present. Belt guard on both starboard and port engine is constructed of wood. Remove wood guard and replace with non-combustable guard. 46CFR176.25-10
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 September 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew and the vessel from electrical hazards including fire and shock. Electric cables affixed to the fuses on stbd side of generator were not fully seated and part of the protective covering was missing. 46CFR183.200
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 September 2025
Resolved
Portable fire extinguishers required iaw table 181.30-1(a). 2A portable fire extinguisher overdue for its 5-year maintainance. 46CFR181.30-1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 September 2024
Resolved
Provisions shall be made by means of plugs, etc., to prevent air into a protected space. Vessel has four engine room vents ducts, and only three duct plugs. 46CFR181.400, 46CFR181.20-35
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 September 2024
Resolved
All vessels shall provide an approved life jacket for everyone onboard. Vessel is authorized to carry 79 total persons in LBS and CW limited in warm water. Vessel has 70 good adult life jackets. VSL restricted pax count. 46CFR180.25-5
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 September 2024
Resolved
Where life preservers are stowed shall be readily visible to pax and marked with "life preserver" and with the number stowed. Several adult life jackets stowed forward of pax saloon with no marking. 46CFR180.25-15
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2024
Resolved
Main propulsion shall be inspected by MI when operated. Engine colling water line has a rubber coupling tha is missing a clamp and leaking water for cooling the STBD engine. 46CFR176.25-35
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2024
Resolved
At each inspection the MI tests main and auxiliary steering. Port shaft log excessively leaking water. 46CFR176.25-35
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 September 2024
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Due to the short fuse notice and unavailability of inspection personnel, your vessel will go past its drop-dead annual inspection date. Schedule an annual inspection not to exceed the 17th month of the COI's anniversary date. Failure to satisfactorily complete an annual inspection will invalidate your COI. Vessel is not authorized to operate in inspected service past 23SEP2024. 46CFR176.500
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 19 September 2023
Resolved
At each inspection the MI shall require all observed unsafe practices and hazardous situations be corrected. Vessel captain and deckhand unable to safely complete MOB drill. Vessel restricted ot operating with pax until new MOB platform is purchased and succesfull MOB drill to satisfaction of [name withheld] may operate in meantime with two deckhands and one master. 46CFR176.25-50
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 September 2023
Resolved
At each inspection, fire fighting equipment shall be inspected and all deficiencies corrected. MI noted 5 year external exam on portable fire extinguishers and fire boy was last completed in 2016. 46CFR176.25-25
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 19 September 2023
Resolved
Each hatch above the waterline shall be weatertight with securing devices. Port lights in rod room missing wing nuts to secure closed and provide weather tightness. 46CFR171.124
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 19 September 2023
Resolved
At each inspection the MI shall examine and test all items in the ships outfit. Hydraulic line for anchor windlass below deck in fwd compartment showed signs of wastage. 46CFR176.25-40
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 September 2022
Resolved
Each hatch exposed to the weather must be watertight. Water tight hatch gasket for the weather deck access to the fuel tank compartment was worn. Ensure a proper gasket is in place to maintain watertightness.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 21 September 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Vessel's bilge high level alarm audible indicator was not functional. Ensure high level audible alarm is operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 September 2022
Resolved
An adult life jacket must be provided for each person carried onboard the vessel. Vessel had a total of 55 adult PFD's that were in satisfactory condition. Vessel is restricted to a total of 55 persons on board until satisfactory CG approved Type 1 PFD's are onboard for the maximum persons on board allowed on the COI of 79 total persons.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 21 September 2022
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. Generator mounting bolt, nut and a machinery guard were found loose. Ensure generator and machinery guard is properly and securely mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 21 September 2022
Resolved
Machinery shall be installed in such a manner as to afford adequate protection against personnel injury. Guard for belts and rotating machinery are missing from the front of the starboard propulsion engine.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 September 2022
Resolved
Machinery shall be installed in such a manner as to afford adequate protection against personnel injury. Guard for belts and rotating machinery are missing from the front of the starboard propulsion engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 June 2021
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Fixed bilge system could not adequately drain water from the lazarette. 46 CFR 182.25-1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2021
Resolved
Means shall be to taken ensure the vessel is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock of personnel. Several disconnected wires were found in the E/R and lazarette and light fixtures missing light bulbs/globes. 46 CFR 183.01-05
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 June 2021
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test main and auxiliary machinery to determine they are in proper operating condition and fit for the intended service. The stbd propulsion engine and the generator are leaking cooling water from the exhaust lines. 46 CFR 176.25-10
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 June 2021
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the main steering apparatus to determine its condition is satisfactory and fit for the service intended. Both rudder post packings leaked an unreasonable amount of water at hard over. 46 CFR 176.25-35
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 June 2021
Resolved
Machinery shall be installed in such a manner as to afford adequate protection against personnel injury. Guards for belts and rotating machinery are missing from the front of both propulsion engines. 46 CFR 182.01-5
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 24 June 2021
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Only one donning placard is posted for a yoke style lifejacket. Vessel is also provided with vest style lifejackets but is missing a donning placard for this style. 46 CFR 185.516
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 June 2021
Resolved
Provisions shall be made by means of plugs, covers, etc., to prevent the admission of air into protected spaces. The engine room's fwd-stbd air intake is missing a foam plug. 46 CFR 181.20-35
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 11 September 2020
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Due to the vessel going through a re-power project and the shifting of battery banks to a different location the vessel is required to undergo a new stability test. 46 CFR 176.840
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2020
Resolved
An adult lifejacket must be provided for each person carried on board the vessel. 04 lifejackets were removed from service. Reduce the vessel's maximum passenger count to 73 until 04 lifejackets are placed into service to the satisfaction of the attending marine inspector. 46 CFR 180.71 (a)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 January 2020
Resolved
Vessel owner/operators shall make any or all repairs within the time period specified by the [name withheld] all oustanding CG835V requirements issued at annual inspection 29OCT2019. 46 CFR 176.500(b)(1)(iii).
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 November 2019
Resolved
Exposed hazards, such as gears or rotating machinery, must be properly protected by a cover, guard or rail. Both main engines have exposed rotating machinery. 46 CFR 177.960
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 1 November 2019
Resolved
Each hatch exposed to the weather must be watertight. Aft deck hatch will not secure in a watertight condition. 46 CFR 171.124
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 November 2019
Resolved
Auxiliary machinery shall be suitable for its intended purpose. Proper operation of generator cannot be demonstrated. Prove proper operation of generator to the satisfaction of attending marine inspector prior to operation of generator. 46 CFR 182.01-5
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 November 2019
Resolved
Vessels shall be inspected for compliance with the standards required by this chapter. For items not covered by the standards in this subchapter, inspection shall be in accordance with standards acceptable by the OCMI as good marine practice. The vessel's freeboard from rail to the waterline is five feet eight inches when measured from the stern. Provide an adequate means to ensure the ability to safely and timely recover a person from the water. 46 CFR 176.25-1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 October 2019
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart and in such a matter as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling and not used as a means of support. Plastic tie wraps are used throughout the engine room as a means of support. Additionally, numerous locations in the engine room did not have electric cable supported at least every 24' by metal supports.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 October 2019
Resolved
Each connection to a conductor or terminal past of a conductor must be made within an enclosure. The #2 battery cable has a splice located forward of the port engine. Installed splices should be done in accordance with 46 CFR 183.340 (g)(3) or (d)(4). In addition, dead end wires were found on the forward bulkhead of the steering compartment. Correct to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 29 October 2019
Resolved
The exhaust piping must be suitably insulated or water cooled. The vessel's turbo's insulation should be re-installed to the satisfaction of the attending marine inspector. 46 CFR 182.15-15
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 October 2019
Resolved
EPIRB's shall be stowed in a manner so that it will float free if the vessel sinks. The EPIRB's Hydrostatic release unit is expired. Vessel's route is limited to
a limited coastwise route of less than three miles from shore.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 29 October 2019
Resolved
A vessel must comply with the applicable requirements for EPIRB installations, including the requirements for a station license and installation certificate to be issued by the FCC. Vessel EPIRB registration was expired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2019
Resolved
An adult lifejacket must be provided for each person carried on board the vessel. 04 lifejackets were removed from service. Reduce the vessel's maximum passenger count to 73 until 04 lifejackets are placed into service to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2019
Resolved
At each inspection all lifesaving equipment shall be inspected to determine its serviceability. Both ring life buoys have deteriorated grab lines and the water light is inoperable. Vessel is limited to daytime operations until verified corrected by attending marine inspector. 46 CFR 176.25-20
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 October 2019
Resolved
Vessels shall carry up-to-date navigation charts, U.S. Coast Pilot or equivalent, and Light List. Vessel is missing previously listed items. 46 CFR 184.420
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 October 2019
Resolved
At each inspection the marine inspector may require a portion of the inspection to be conducted while the vessel is underway so that the hull and internal structure can be observed. Vessel is required to complete an underway inspection. 46 CFR 176.802
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 October 2019
Resolved
Each life float must be secured to the vessel by a painter and a float-free link. Found both life floats were secured to the vessel with a float-free link, but were also tied down to the cradles thereby preventing the life floats from floating free. 46 CFR 180.20-1
Stability › Watertight Integrity › General
Issued 10 August 2017
Resolved
Make proper repairs to both rudder post packings.
Documentation › Markings/Placards › Capacity Marking
Issued 10 August 2017
Resolved
Properly mark the stowage locations of lifejackets.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 August 2017
Resolved
Submit written proposal for raising railing height to the required height.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 10 August 2017
Resolved
Provide device to secure vents to engine room.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 July 2017
Resolved
Place cable splice in a junction box in forepeak.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 July 2017
Resolved
Remove dead end wire at light switch in forepeak.
Electrical › Electrical Distribution System (service) › Fuse
Issued 27 July 2017
Resolved
Renew wire/cable at fuse terminal for water pump to toilets.
Electrical › Electrical Distribution System (service) › Conductor
Issued 27 July 2017
Resolved
Replace wire/cable from battery charger to generator battery with approved marine cable.
Stability › Watertight Integrity › General
Issued 27 July 2017
Resolved
Make sewage overboard valve operable without use of tools.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 July 2017
Resolved
Install guard over alternator & alt belts on stbd engine.
Engineering › Bilge Water Management System › Strainer
Issued 27 July 2017
Resolved
Install screens on all bilge suction lines.
Fire Fighting › Nozzles › Number
Issued 27 July 2017
Resolved
Provide nozzle for fire hose.
Documentation › Markings/Placards › Lifejacket Placard
Issued 27 July 2017
Resolved
Provide donning instructions for vest style lifejackets.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 July 2017
Resolved
Support wires entering junction box on fwd blkhd in tank space.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 9 June 2017
Resolved
Provide 79 adult & 8 child lifejackets in a service ready condition.
Lifesaving › Hand Flares › Expired
Issued 9 June 2017
Resolved
Provide 6 red flares with 6 orange flares -or- 12 red flares.
Lifesaving › Lifefloat › Painter
Issued 9 June 2017
Resolved
Provide new painter for lifefloats.
Lifesaving › Lifefloat › Painter
Issued 9 June 2017
Resolved
Provide new line (tether) attaching each lifefloat to the painter.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 June 2017
Resolved
Install the lifefloat floating waterlights in a float free location.
Communications › Radio Communications › EPIRB
Issued 9 June 2017
Resolved
Install new hydrostatic release unit for EPIRB.
Communications › Radio Communications › EPIRB
Issued 9 June 2017
Resolved
Provide valid EPIRB registration.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 9 June 2017
Resolved
12 year service for fixed fire extinguishing system in E/R is past due
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 9 June 2017
Resolved
Install bonding wire from fuel fill to fuel tank.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 June 2017
Resolved
Provide valid certificate of documentation.
Documentation › Certificates/Documents › FCC SSL
Issued 9 June 2017
Resolved
Provide valid FCC Station License.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 June 2017
Resolved
Update or provide new FCC Safety Certificate.
Stability › Watertight Integrity › General
Issued 9 June 2017
Resolved
Repair/Service watertight deck hatches.
Engineering › Bilge Water Management System › Pump
Issued 9 June 2017
Resolved
Prove proper operation of bilge pump fwd of collision blkhd.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 9 June 2017
Resolved
Install proper securing device for reach rods to emergency fuel shut-off valves.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 August 2016
Resolved
Provide adequate retro
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 8 August 2016
Resolved
Provide means to secure ovbd discharge
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 8 August 2016
Resolved
Provide LNM
Communications › Radio Communications › VHF Radiotelephone
Issued 8 August 2016
Resolved
Provide means to transmit GPS coordinates via VHF/DSC
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 August 2016
Resolved
Provide service report for installed system
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 August 2016
Resolved
Provide accurate count labeling in locations provided
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 8 August 2016
Resolved
Provide 12 additional lights for PFDs
Lifesaving › Visual Distress Signals (General) › Expired
Issued 8 August 2016
Resolved
Provide new smokes
Fire Fighting › Nozzles › Number
Issued 8 August 2016
Resolved
Provide nozzle for fire hose
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 August 2016
Resolved
Conduct MOB with new vessel master
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 August 2016
Resolved
Provide current log book
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 June 2014
Resolved
FCC Safety Radio Certificate is expired. Renew as original with FCC.
Documentation › Certificates/Documents › Stability Letter
Issued 4 June 2014
Resolved
Vessel Stability Letter is to be posted behind glass for passengers to view.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 4 June 2014
Resolved
Vessel's drug and alcohol program records were not available for inspection.
Personnel › Training › First Aid/CPR
Issued 4 June 2014
Resolved
Provide proof of First Aid/CPR training for 50% of all crew members.
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 June 2014
Resolved
Provide current and up to date U.S. Coast Pilot and U.S. Coast Guard Light List.
Communications › Radio Communications › EPIRB
Issued 4 June 2014
Resolved
Hydrostatic release for EPIRB is expired. Replace as original prior to carrying passengers (PTCP).
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 4 June 2014
Resolved
Waterlight for buoyant apparatus did not work. Repair or replace as original prior to carrying passengers (PTCP).
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 June 2014
Resolved
Waterlight for lifebuoy had water in bulb. Repair or replace as original prior to operations at night and by specified date.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 4 June 2014
Resolved
Ground wire for fuel fill was not connected to fuel tank. Repair PTCP.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 June 2014
Resolved
Bilge alarms in bow compartment is not functioning correctly. Repair as original prior to carrying passengers (PTCP). Short term exception until 6/13/14 allowed if vessel maintains one hour soundings of both spaces with written records logged in the vessel's log book for all times that passengers are on board the vessel.
Fire Fighting › Fire Bucket › Availability
Issued 8 May 2007
Resolved
Provide three fire buckets with lanyards.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 8 May 2007
Resolved
Replace 31 waterlight batteries.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 May 2007
Resolved
Provide emergency checkoff list
Lifesaving › Lifefloat › Float Free
Issued 8 May 2007
Resolved
Provide float free arrangement for lifefloats.
Engineering › Bilge Water Management System
Issued 3 June 2004
Resolved
Repair Bilge high level alarm system. (no visual or audible signals working.)
Electrical › Lighting (service) › Lighting Fixture
Issued 3 June 2004
Resolved
Repair stern nav light.
Engineering › Bilge Water Management System
Issued 23 June 2003
Resolved
PROVE PROPER OPERATIONS OF ELECTRIC BILGE PUMP IN LAZARETTE BOTH IN MANUAL AND AUTOMATIC MODES WITH VISUAL INDICATOR IN PILOT HOUSE LEGACY COMPONENT DESC: electric bilge pump
Engineering › Bilge Water Management System
Issued 23 June 2003
Resolved
PROVE PROPER OPERATION OF FIXED BILGE PIPING SYSTEM IN LAZARETTE (DOESNOT DRAW SUCTION) LEGACY COMPONENT DESC: FIXED BILGE SYSTEM
Documentation › Certificates/Documents
Issued 23 June 2003
Resolved
PROVIDE FCC RADIO STATION LICENSE LEGACY COMPONENT DESC: FCC STATION LICENSE
Documentation › Certificates/Documents
Issued 23 June 2003
Resolved
PROVIDE RADIO STATION LICENSE LEGACY COMPONENT DESC: FCC RADIOTELEPHONY
Engineering › Fuel Oil Storage/Transfer System
Issued 23 June 2003
Resolved
REPLACE STBD FUEL TANK SHUT OFF VALVE LEGACY COMPONENT DESC: FUEL SHUT OFF VALVE
Lifesaving
Issued 18 April 2001
Resolved
MAKE EFFECTIVE REPAIR TO LIFE FLOAT.
Lifesaving
Issued 18 April 2001
Resolved
POST FCC EMERGENCY RADIO INSTRUCTIONS.
Fire Fighting
Issued 18 April 2001
Resolved
SERVICE ALL FIRE PROTECTION EQUIPMENT.
Lifesaving
Issued 18 April 2001
Resolved
PROVIDE WORKING LIGHTS FOR (19) ADULT & (05) CHILD LIFE JACKETS.
Navigation
Issued 18 April 2001
Resolved
PROVIDE CURRENT & CORRECT NAVIGATION CHARTS & PUBS FOR AREA OF OPERATION.
Construction/Loadline
Issued 12 May 1999
Resolved
ATTACH RETAINING LINE ON FORWARD DECK HATCH.
Construction/Loadline
Issued 12 May 1999
Resolved
COMPLETE INSTALLATION OF HIGH WATER BILGE ALARMS._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 12 May 1999
Resolved
OBTAIN VENT CLOSURES FOR ENGINE ROOM INTAKES._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 24 April 1998
Resolved
PROVIDE ON BOARD A SAFETY HARNESS FOR MAN OVER BOARD RETRIEVEL.
Lifesaving
Issued 10 April 1998
Resolved
Provide a safety harness for man over board retrieval.
Construction/Loadline
Issued 10 April 1998
Resolved
Repair or replace bilge suction bell in lazerette.
Construction/Loadline
Issued 10 April 1998
Resolved
Repair bilge pipe connection in fwd compartment.
Fire Fighting
Issued 10 April 1998
Resolved
Service port side cabin fire extinguisher.
Lifesaving
Issued 10 April 1998
Resolved
Provide 26 additional adult PFD's.
Construction/Loadline
Issued 10 April 1998
Resolved
Prove proper operation of bilge suction from lazerette and fwd compt.
Navigation
Issued 10 April 1998
Resolved
Install proper bulbs in all Navigation lights._x001C_
Lifesaving
Issued 10 April 1998
Resolved
Provide on board a C. G. approved first aid kit.
Fire Fighting
Issued 10 April 1998
Resolved
Prior to the carriage of passengers replace fire hose.
Lifesaving
Issued 10 April 1998
Resolved
Replace retro-reflective tape on eight (8) childs PFD's.
Lifesaving
Issued 22 April 1997
Resolved
RENEW WATER LIGHTS ON 13 ADULT PFD'S
Lifesaving
Issued 22 April 1997
Resolved
RENEW EPIRB BATTERY AND TEST OPERATION.
Lifesaving
Issued 22 April 1997
Resolved
PROVIDE ONE ADDITIONAL CHILDS PFD.
Lifesaving
Issued 22 April 1997
Resolved
RENEW RETRO REFLECTIVE TAPE ON BUOYANT APPARATUS.
Construction/Loadline
Issued 19 April 1994
Resolved
CLEAN THE ENGINEROOM BILGE THEN DEMONSTRATE PROPER OPERATION OF THE BILGE PUMP.
Navigation
Issued 19 April 1994
Resolved
PRIOR TO OPERATING AT NIGHT OR IN RESTRICTED VISIBILITY, PROVE PROPER OPERATION OF THE NAVIGATION LIGHTS.
Construction/Loadline
Issued 12 April 1994
Resolved
PRIOR TO CARRY PASSENGER FOR HIRE, REPLACE ROTTED COLLISION BULKHEAD AND TESTED FOR WATERTIGHT IN FOREPEAK COMPT TO SATISFACTION OF USCG MARINE INSPECTOR.
Construction/Loadline
Issued 12 April 1994
Resolved
PRIOR TO CARRY PASSENGER FOR HIRE, MAKE REPAIR TO #1 STBD FRACTURED FRAME IN FORPEAK TO SATISFACTION OF USCG MARINE INSPECTOR.
Electrical
Issued 6 May 1993
Resolved
REPAIR OR REPLACE ELECTRICAL JUNCTION BOX FOR BILGE PUMP IN #2 COMPT.
Navigation
Issued 6 May 1993
Resolved
PROVIDE PROPER CHARTS FROM SANDY HOOK, NJ TO CAPE CHARLES, VA OTHERWISE VESSEL IS RESTRICTED TO OPERATE BETWEEN ATLANTIC CITY, NJ AND CHINCOTEAGUE,VA.
Navigation
Issued 6 May 1993
Resolved
PROVIDE PROPER EPIRB ON BOARD, VESSEL IS RESTRICTED TO COASTWISE ROUTE UNTIL PROPER EPIRB IS ON BOARD.
Lifesaving
Issued 30 April 1992
Resolved
REPLACE PRESENT CLASS A EPIRB ONBOARD WITH SAME OR MORE UPDATED TYPE_x001C_ MANUFACTURED AFTER 1988 AND SHOW PROPER OPERATION .
Documentation
Issued 6 June 1991
Resolved
RENEW FCC RADIO SAFETY CERTIFICATE.
Navigation
Issued 6 June 1991
Resolved
REPLACE ALL NAVIGATION CHARTS WITH CURRENT CHARTS._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 21 March 1990
Resolved
VESSEL EPIRB HAS BEEN SENT OUT FOR REPAIRS VESSEL IS RESTRICTED TO COASTWISE ROUTE UNTIL EPIRB IS BACK ON BOARD.
Lifesaving
Issued 7 April 1989
Resolved
REPLACE DATED BATTERIES ON 92 ADULT LIFE JACKET LIGHTS AND 10 CHILD'S LIFE JACKETS LIGHTS. VESSEL IS RESTRICTED TO COASTWISE ROUTE UNTIL REPLACED.
Construction/Loadline
Issued 3 June 1987
Resolved
PROVIDE SECURING CHAINS FOR ALL WEATHER DECK HATCHES.
Lifesaving
Issued 3 June 1987
Resolved
PROVIDE WATER LIGHTS FOR SIX (6) ADULT LIFE PRESERVERS.
Documentation
Issued 3 June 1987
Resolved
MOUNT ALL CERTIFICATES, NOTICES, AND LICENSES.
Electrical
Issued 8 May 1986
Resolved
PROVIDE AMMETER FOR DC SYSTEM OR COVER OPENING IN POWER PANEL IN WHEELHOUSE
Documentation
Issued 8 May 1986
Resolved
OBTAIN FCC INSPECTION FOR ISSUANCE OF A RADIOTELEPHONE SAFETY CERTFICATE.
Casualty record · 1
19 September 2009Routine · role: Involved in a Marine Casualty · activity 3600283
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
SEA MIST (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.