AMERICAN ANGLER

Built
1986
Last inspected
31 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD6980
267975
Flag
UNITED STATES
Maury page id
psix-267975

Documentation record

Registered dimensions (L × B × D)81.6 ft × 24.0 ft × 6.5 ft
Registered tonnagegross 93 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPOOLE BOAT COMPANY INC · CHULA VISTA, CA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 6 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 32 inspections, each with its date, unit and type; 30 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

31 March 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8319462
5 February 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8306528
24 March 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8097642
25 September 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8009152
19 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7881726
8 February 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7862777
21 November 2023 Deadweight Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7828425
23 October 2023 Appeal
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7812936
22 May 2023 Appeal
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7713413
21 March 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7654289
8 December 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7606228
16 November 2022 Excursion Permit · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7595796
7 August 2022 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7535902
23 March 2022 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7418082
24 January 2022 COI Inspection · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7384801
17 September 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7314814
2 September 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7302778
14 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7175350
20 January 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7149158
18 August 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7036208
28 April 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6945295
19 February 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6912385
23 October 2019 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6840273
13 August 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6784732
13 August 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6821956
3 July 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6734931
25 April 2019 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6670007
6 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6534032
21 March 2018 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6375913
21 April 2017 COI Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6131869
20 April 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5858403
11 March 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5831365

Deficiency record · 30

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2026 Resolved
Except for the purpose of flexibility vital system piping shall be metallic. Double clamped flexible hose may be used for areas less than 30 inches. PVC piping was found on engine cooling system and bilge piping. Replace all PVC piping with metallic fittings.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2026
Resolution: Piping was restored to metallic fittings.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 March 2026 Resolved
Vessel's of 65' or more in length are required to have a rescue boat. OCMI may allow a rescue platform instead of a rescue boat. Vessel was equipped with rope ladder and man overboard drill was observed to be inadequate for recovering a helpless victim. Provide vessel with adequate rescue platform.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2026
Resolution: Vessel had custom made aluminum ladder built for MOB scenarios.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 31 March 2026 Resolved
Digital selective calling VHF radios are required to have vessel's MMSI number and position. Designate one radio as "distress" radio and prove function of MMSI and Lat/Long.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2026
Resolution: Radio was equipped with MMSI and Lat/Long.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 March 2025 Resolved
A Device must be provided to automatically shutdown power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. CO2 pressure switch was inoperable. Provide service report when system is fully operational.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2025
Resolution: O/O had CO2 tech repair/replace switch. Witnessed test, test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel experienced loss of generator while underway.
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2024
Resolution: Witnessed satisfactory test.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 March 2023 Resolved
Vessel failed to have updated logs for required drills. Update logs with drills.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 21 March 2023
Resolution: Updated logbook
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2023 Resolved
Vessel E-Light IWO aft accommodation space found to be inoperable. Repair or replace light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 March 2023
Resolution: Replaced light bulb.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 September 2021 Resolved
Each space accessible to passengers must have two means of escape. The second means of escape from the passenger accommodation space was found blocked with a long slip resistant mat. Deficiency was corrected on the spot by removing the mat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2021
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021 Resolved
Remove wire nuts from wire connections above galley reefer and replace with pressure type connectors. Clean grease from all wiring above galley reefer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2021
Resolved 15 April 2021
Resolution: Provided pictures via email showing the correction to pressure type connectors and cleaned up grease.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021 Resolved
Remove wire nuts from wire connections within the bridge console and replace with pressure type connectors.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2021
Resolved 15 April 2021
Resolution: Provided pictures via email showing the correction to pressure type connectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021 Resolved
Remove identified dead end wires from within the bridge console.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2021
Resolved 15 April 2021
Resolution: Provided pictures via email showing the removed dead end wires.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021 Resolved
Remove the two outlet extenders from within the bridge console.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2021
Resolved 15 April 2021
Resolution: Provided pictures via email showing the removed power taps.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2020 Resolved
08 LIFE JACKET LIGHTS WERE FOUND INOPERABLE. VESSEL RESTRICTED TO CARRY NO MORE THAN 32 ADULTS AND 3 CHILD/PERSONS OF 90 LBS OR LESS WHEN ON A COASTWISE OR OCEANS ROUTE.
Action required: 705 - Other - as specified
Resolved 26 May 2020
Resolution: lights replaced and verified
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 28 April 2020 Resolved
ENSURE RECENTLY SERVICED LIFE RAFTS ARE PROPERLY INSTALLED ONBOARD THE VESSEL PRIOR TO DEPARTURE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2020
Resolution: LR's brought onboard vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2020 Resolved
Repair compromised aft fuel tank with leak identified from starboard rudder tube. Provide repair proposal for approval prior to repairs. Vessel may not sail with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2020
Resolution: Repairs completed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 October 2019 Resolved
Install smoke detector in galley area and in below deck, forward crew berthing space. Due 23Nov2019. 46 CFR 181.450.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 15 April 2020
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019 Resolved
Properly install A/C panel covers, closure plates, and circuit breaker blanks as identified. Due 23Nov2019. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 15 April 2020
Resolution: Installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2019 Resolved
Replace plastic garbage cans in high fire risk areas with metal cans. Due 23Nov2019. 46 CFR 177.405.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 15 April 2020
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 October 2019 Resolved
Properly label top side of emergency escape to aft berthing space. Due 23Nov2019. 46 CFR 185.606.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 15 April 2020
Resolution: Properly Lablled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps. Due 23Jan2020. 46 CFR 177.202.
Action required: 705 - Other - as specified
Due 23 January 2020
Resolved 15 September 2020
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 23 October 2019 Resolved
Remove battery located in crew bunk-room and store in proper location, cover and secure. Due 23Nov2019. 46 CFR 183.350.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 15 April 2020
Resolution: Removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019 Resolved
Remove surge protector and install outlets in communications cabinet, port side wheel house, aft. Due 23Jan2020. 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 23 January 2020
Resolved 15 April 2020
Resolution: Found SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019 Resolved
Install cover over exposed buss bars in communications cabinet, port side wheel house, aft. Due 23Nov2019. 46 CFR 183.220.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 15 April 2020
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019 Resolved
Provide television with dedicated outlet within reach of television factory cord. Due 23Jan2020. 46 CFR 183.200.
Action required: 705 - Other - as specified
Due 23 January 2020
Resolved 15 April 2020
Resolution: Installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019 Resolved
Remove permanently installed extension cord from starboard engine room A/C panel. Due 22 November 2019. 46 CFR 183.200.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 15 April 2020
Resolution: Removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2019 Resolved
Remove all 'Relocatable Power Taps" from vessel. Due 22 November 2019. 46 CFR 183.200.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 November 2019
Resolved 15 April 2020
Resolution: Removed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 October 2019 Resolved
Replace discharged portable fire extinguisher.
Action required: 10 - Deficiency Rectified
Resolved 23 October 2019
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 April 2019 Resolved
Provide retro tape for ringbuoy.
Action required: 60 - Rectify deficiencies prior to movement
Due 25 April 2019
Resolved 25 April 2019
Resolution: Retro tape provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 April 2019 Resolved
Makr emergency fuel shut off operational.
Action required: 60 - Rectify deficiencies prior to movement
Due 25 April 2019
Resolved 25 April 2019
Resolution: Emergency fuel shutoff operational.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 6 September 2018 Resolved
IMO: Vsl is broadcasting invalid IMO #, LENGTH DIFF: greater/smaller than expected vessel length, ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: Verified in VIVS

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.