Records from 1986 to 2011. Most recent: inspection, 2 December 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
2 December 2011
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 4200133
23 September 2011
Administrative Inspection
Administrative · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4152531
14 October 2010
Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 3869715
22 July 2008
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3275794
11 April 2007
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2905692
8 June 2006
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2673815
10 April 2006
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2621020
19 September 2005
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2495991
22 April 2005
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2340916
4 October 2004
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2212717
23 April 2004
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2049134
27 May 2003
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1819672
22 April 2002
Annual Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1782081
25 April 2001
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1384747
4 October 2000
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1405056
16 May 2000
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 818495
24 April 2000
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1373030
26 April 1999
Plan Review "T" Boat · Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1129999
28 April 1998
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1124255
27 May 1997
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1109910
28 April 1997
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1434551
19 April 1996
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1079998
5 September 1995
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1188900
30 May 1995
Administrative
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 872127
17 April 1995
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1420962
18 April 1994
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1358410
20 April 1993
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 841023
20 April 1992
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 962306
15 April 1991
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1229040
21 March 1991
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1304522
25 April 1990
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 918204
1 May 1989
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1040485
5 May 1988
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1347299
16 May 1986
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 991732
6 May 1986
Initial Construction-Excluding Oversight
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 994331
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 July 2008
Resolved
Provide lare and fire extinguishers in current date.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2010
Resolution: All fire extinguishers and Halon are current in expection via third party.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 23 July 2008
Resolved
Provide on board lifejackets and primary life saving equipment.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2010
Resolved 14 October 2010
Operations/Management › Drills/Instruction › Fire
Issued 23 July 2008
Resolved
Demonstrate man overboard and fire drill.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2010
Resolution: Demenstrated drills while U/W.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 April 2006
Resolved
Get vessel U/W to conduct MOB drill in the presence of a Marine Inspector.
Due 25 May 2006
Resolved 7 June 2006
Engineering › Bilge Water Management System › Not Operational
Issued 10 April 2006
Resolved
Prove proper operation of the installed manual engineroom compartment, bilge suction.
Condition: Improper/Lack of Maintenance
Due 25 May 2006
Resolved 7 June 2006
Stability › Watertight Integrity › General
Issued 10 April 2006
Resolved
Ensure both deck hatches dog closed tightly.
Condition: Improper/Lack of Maintenance
Due 25 May 2006
Resolved 7 June 2006
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 10 April 2006
Resolved
Repair broken sewage take supply line.
Condition: Improper/Lack of Maintenance
Due 25 May 2006
Resolved 7 June 2006
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 10 April 2006
Resolved
Replace wooden engine block spacer with a non-flammable one or provide a report from the manufacture stating the existing one is acceptable.
Condition: Improper Installation
Due 25 May 2006
Resolved 7 June 2006
Construction/Loadline › Hull › Bottom Plating
Issued 19 September 2005
Resolved
Re-glass or epoxy the port side shaft log IWO the hull.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2006
Resolved 25 April 2006
Construction/Loadline › Hull › Keel
Issued 19 September 2005
Resolved
Re-seal the longitudinal checks in the wooden skeg using 3M, 5200 marine sealant.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2006
Resolved 25 April 2006
Documentation › Markings/Placards › Official Number (US)
Issued 19 September 2005
Resolved
Re-stencil vessel's name on the stern.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2006
Resolved 25 April 2006
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 19 September 2005
Resolved
Reattach the upper rudder post guide block (3-screws were missing or never installed).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2006
Resolved 25 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 September 2005
Resolved
Repair deteriorated glass work in the forward, cabin, on the end of the port stringer IWO the hull.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2006
Resolved 25 April 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 September 2005
Resolved
Repair or replace rotten partial longitudinal panels and lower support pieces, on the port side of the forward cabin head area or provide a statement from the vessel manufacture that the members are non-structural.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2006
Resolved 25 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 April 2005
Resolved
Hang wires in engine space with metal supports.
Due 25 May 2005
Resolved 11 May 2005
Communications › Radio Communications › EPIRB
Issued 22 April 2005
Resolved
Ensure that NOAA registration is current and place sticker on the EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 April 2004
Resolved
Ensure first aid kit meets 46 CFR 160.041
Due 23 May 2004
Resolved 5 May 2004
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 23 April 2004
Resolved
Properly label child life jacket stowage
Due 23 May 2004
Resolved 5 May 2004
Lifesaving › Lifebuoys
Issued 23 April 2004
Resolved
Replace vessel life ring.
Condition: Improper/Lack of Maintenance
Due 23 May 2004
Resolved 5 May 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 23 April 2004
Resolved
Install engineroon vent closures.
Condition: Design Flaw
Due 23 May 2004
Resolved 5 May 2004
Construction/Loadline › Hull › Stiffener
Issued 23 April 2004
Resolved
Properly repair aft main deck fracture on both sides of steering compartment hatch. LEGACY COMPONENT DESC: Deck
Condition: Unknown
Due 1 September 2004
Resolved 4 October 2004
Electrical › Electric Supply System (service) › Cable
Issued 27 May 2003
Resolved
REMOVE OR PROPERLY STOW ALL DEAD ENDED WIRES.
Due 27 May 2003
Resolved 4 October 2004
Construction/Loadline › Structures
Issued 27 May 2003
Resolved
REMOVE ALL SATURATED WOOD FROM FWD CABIN TAKE MOISTURE READINGS ON HULL AND BULKHEADS AND MAKE PROPOSAL FOR REPAIRS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2003
Resolved 29 May 2003
Resolution: VISITED VESSEL TO EXAMINE AREA IN FWD CABIN. HULL AND BULKHEADS ARE WET HOWEVER THERE IS NO INDICATION OF DAMAGE CAUSED BY THIS MOISTURE. OPERATING SEASON FOR VESSEL ENDS FIRST WEEK OF JULY. OWNER TO SUBMITT PLANS FOR WORK DURING OFF SEASON.
Construction/Loadline › Structures › Deck Plating
Issued 27 May 2003
Resolved
MAKE REPAIR PROPOSAL FOR FWD CABIN STRUCTURES THAT HAVE HIGH MOISTURE CONTENT. INCLUDE METHOD OF PROPER VENTILATION FOR SPACES.
Due 31 October 2003
Resolved 4 October 2004
Engineering › Bilge Water Management System
Issued 27 May 2003
Resolved
BILGE OVERBOARD VALVE MISSING INTERNALS. REPAIR OR RENEW VALVE. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2003
Resolved 29 May 2003
Resolution: VALVE RENEWED.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 22 April 2002
Resolved
Replaced on scene 08 adult Type I PFD's.
Condition: Improper/Lack of Maintenance
Due 22 April 2002
Resolved 22 April 2002
Resolution: Replaced.
Engineering
Issued 24 April 2000
Resolved
Prior to carrying passengers repair FRP exhaust pipe in steering compartment.
Condition: Unknown
Due 24 April 2000
Resolved 16 May 2000
Engineering
Issued 28 April 1997
Resolved
Remove petcock from fuel filter and replace with pipe plug to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Unknown
Issued 28 April 1997
Resolved
Provide vessel with first aid kit as per 46 CFR 184.710 and 160.041 to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Navigation
Issued 28 April 1997
Resolved
Provide emergency radio instruction placard as per 46 CFR 184.506 to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 28 April 1997
Resolved 28 April 1997
Lifesaving
Issued 17 April 1995
Resolved
REPAIR OR REPLACE TORN AND CRACKED LIFE FLOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Documentation
Issued 15 April 1991
Resolved
PROVIDE ORIGINAL STABILITY LETTER
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Documentation
Issued 15 April 1991
Resolved
PROVIDE GARBAGE PLACARD.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991