← All vessels
BLACK POINT
BLACK POINT is a 1985 tank ship. The Coast Guard has recorded 56 inspections since 1986, most recently in March 2007, along with 73 deficiencies and 2 operational controls.
Records from 1986 to 2007. Most recent: inspection, 28 March 2007.
- Built
- 1985
- Last inspected
- 28 March 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 73 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7907790 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ICBJ
267999
Flag
ITALY
—
Maury page id
psix-267999
Inspections, by type
…with no type recorded36
Years with a record
18 calendar years (1986–2007)
The 56 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it27001 - Simplified, Gross Ton
27001 - Convention (Subpart B), Gross Ton
16108 - Simplified, Net Ton
16108 - Convention (Subpart B), Net Ton
46828 - Dead Weight, Ton
58264 - Displacement, Ton
27001 - Convention (Subpart B), Gross Ton
16108 - Simplified, Net Ton
16108 - Convention (Subpart B), Net Ton
46828 - Dead Weight, Ton
58264 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 56
28 March 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2897149
20 March 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2891628
13 March 2007
Ballast Water Examination · COC-TVE Renew · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2886414
13 March 2007
Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 2887228
13 June 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2678099
2 May 2006
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2638818
29 April 2006
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2636436
9 March 2005
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2306414
4 March 2005
ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2301547
4 March 2005
COC-TVE Renew
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2303986
3 March 2005
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2566968
4 June 2004
MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2088600
3 May 2004
MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2058883
3 May 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2059530
4 May 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1786060
26 April 2003
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1780801
30 December 2002
MARPOL Annex I Examination · Tank Vessel Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1722040
21 March 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 288253
21 March 2001
Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1393629
21 February 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 287298
5 January 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 285817
5 January 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366115
27 May 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 278327
24 September 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 201452
24 September 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 760591
23 August 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 431937
12 July 1999
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 430533
12 July 1999
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1095727
11 May 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 428506
24 January 1999
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 424858
23 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 418375
12 June 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 417456
12 June 1998
Letter of Compliance (Initial/Renewal)
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1444018
26 February 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 412930
27 August 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 394838
16 July 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 380570
9 June 1994
Deficiency Check · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448551
28 April 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 366291
28 April 1994
Tank Vessel Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1398064
30 March 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 357197
7 October 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 353886
25 September 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 498299
18 May 1992
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 350877
15 April 1992
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267223
19 February 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 185795
20 October 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 437254
28 March 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 342658
11 March 1991
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001547
26 October 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327124
26 October 1987
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327277
25 October 1987
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 507794
23 October 1987
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1325203
12 September 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 318358
9 December 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 503193
21 May 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 308996
20 May 1986
Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 521040
Deficiency record · 73
Operations/Management › Pollution › Control of Garbage
Issued 13 March 2007
Resolved
Garbage is mixed throughout the vessel including at the final collection point prior to at sea disposal. All categories of garbage are mixed together. Garbage records indicate food waste was disposed of at sea; in food drum on aft deck, bag contained large amounts of plastic.
Operations/Management › Pollution › Control of Garbage
Issued 13 March 2007
Resolved
Crew is not following garbage management plan. Containers are not color coded properly, garbage is not segregated, garbage is kept in plastic bags, not paper bags as plan states. Since July 2005, although garbage has been incinerated, no record of incineration was made in garbage log.
Engineering › Steering Gear System › Actuator
Issued 13 March 2007
Resolved
Fixed storage tank (900liter cap) of hydraulic oil for the steering gear is empty. In case of an incident where recharging the system is necessary, no spare oil of the proper grade was available. The system has been consuming 5 liters/day indicating constant leakage. Provide required hydraulic fluid prior to movement, address excessive leaks prior to departure to satisfaction of class/flag rep.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 13 March 2007
Resolved
CG inspectors witnessed crewmember pouring hydraulic oil contaminated water into the San Francisco Bay. Water was being cleaned up from the containment surrounding the forward winch. Approx 20 liters of contaminated water was disposed of. This demonstrates lack of knowledge to essential shipboard procedures for the protection of the environment.
MARPOL I/15.1; 33CFR155.310a2; ISM Code 6.4
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 13 March 2007
Resolved
Based on defs noted & previous USCG concern recorded on 02MAY2006 regarding ISM implementation, COTP SF questions the adequacy of SMS implementation IAW ISM code. An external audit is requested to be conducted by the flag state or RO to determine whether the ship is operating IAW ISM prior to departure in presence of CG inspector during daylight hours. SOLAS 74(am) IX/5
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 13 March 2007
Resolved
BWM plan is missing handling log, training, duties of personnel, & sampling points. No record of training having been conducted for crew. Ballast operation is essential for safe operation and document is not complete/properly controlled/followed as required. Address to the satisfaction of class society/flag representative and Coast Guard prior to departure.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 March 2007
Resolved
Tank inspections (cargo & ballast) not conducted in 180 day intervals as required by SMS. Last inspections were 9/2005 for cargo tanks and 10/2005 for ballast tanks. This greatly increases the risk, given the age/condition of the vessel, that structural problems could go undetected for a long period of time. Address to the satisfaction of class society/flag representative prior to departure.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 13 March 2007
Resolved
All 4 vapor control lines do not have pins at the 12 o' clock position at both manifolds. This condition allows a cargo line to accidentally be connected to the vapor control line. Address to the satisfaction of class society/ flag representative prior to departure.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 13 March 2007
Resolved
Nearly all fixed containment surrounding various fuel/oil tank vents throughout the vessel had holes drilled into them at approx the 50% capacity level, reducing the containment's ability to prevent oil from reaching the deck. Address to the satisfaction of class society/flag rep prior to departure from port.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 March 2007
Resolved
Sounding pipe for forepeak tank is wasted/unusable; crew completely unbolted manhole cover to tank in order to visually verify the tank level and cover; unknown how long cover has been unsecured. No non-conformity reports have been submitted to the company/no corrective action has been taken. Address to the satisfaction of class society/flag rep. prior to departure. ISM code Pt. A 9, 10
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 13 March 2007
Resolved
Both GPS receivers on the bridge have unreadable displays; in some modes essential information can not be determined. No non-conformity reports have been submitted to the company/no corrective action has been taken. Address to the satisfaction of class society/flag rep prior to departure.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 March 2007
Resolved
Collision/excessive list/grounding drills have not been conducted since 2004, greatly increasing the risk that the crew will not respond properly in an emergency of that nature. These drills are required by the vessel response plan. Address to the satisfaction of class society/flag representative prior to departure.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 13 March 2007
Resolved
SOLAS lifesaving training manual and fire fighting manual are not located within the crew mess rooms. Training manuals must be available to the crew in the mess rooms and recreation rooms.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 March 2007
Resolved
Excessive hydraulic leaks were found in the following areas on the weather decks, greatly increasing the risk that hydraulic oil will reach the sea. No non-conformity reports have been submitted/no corrective action taken. Address to the satisfaction of class/ flag rep prior to departure. (fwd port winch, anchor mooring winches,fwd ballast pump room,stbd cargo hose crane,1 center tank pump)ISMpt.A
Construction/Loadline › Structures › Door
Issued 13 March 2007
Resolved
Below listed watertight doors are wasted and not watertight, compromising watertight integrity of several spaces onboard. No non-conformity reports have been submitted to the company/ no corrective action has been taken. Address to the satisfaction of class society/flag rep prior to departure. (paint store, port center deck store room, stbd center deck store room, aft ballast pump room.)
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 March 2007
Resolved
Soft patches/temp. repairs found at the following locations; No non-conformity reports were submitted/no corrective action has been taken. Address to the satisfaction of class/flag prior to departure. (2 center tank drop line, ventilation in fwd boson stores, valve p8 in fwd ballast pump room, salt water line to evaporator, freshwater cooling inlet to air compressors, aux. engine overboard line)
Electrical › Electrical Distribution System (service) › Cable
Issued 13 March 2007
Resolved
Several electric cable runs in electrical lockers on successive decks have large pieces of fire-resisting insulation broken away to allow installation of new wires. Address to the satisfaction of class society/flag representative prior to departure. SOLAS 74 (am) II-2/14.2.1.1
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 March 2007
Resolved
Eductor system in forward boson stores is reported to be inoperable. No non-conformity reports have been submitted to the company/ no corrective action has been taken. Address to the satisfaction of class society/flag representative prior to departure. ISM Code Part A 10.2
Electrical › Lighting (service) › Lighting Fixture
Issued 13 March 2007
Resolved
Several lights throughout the cargo deck/ ballast pump room areas are missing or have broken grounding straps, allowing for improper build up of static electricity. Address/repair to the satisfaction of class society/flag representative prior to departure.
Construction/Loadline › Structures › Door
Issued 13 March 2007
Resolved
Several exterior doors on the accommodation spaces are wasted and are not weather tight. Address all exterior doors to the satisfaction of class society/flag representative prior to departure.
Fire Fighting › Structural - B Class Divisions › Corridors
Issued 13 March 2007
Resolved
Several holes have been drilled into deck 3, port side, corridor B-class bulkhead. This condition reduces the fire resisting properties of the bulkhead. Address to the satisfaction of class society/flag representative prior to departure.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 13 March 2007
Resolved
A B-15 door is listed on the fire plan, on the first poop deck port side, is missing, rendering useless the fire resistance required of that area in the fire control plan. No non-conformity reports have been submitted to the company/no corrective action has been taken. Address to the satisfaction of class/flag representative prior to departure. ISM Code part A 9, 10
Fire Fighting › Structural - A Class Divisions › Doors
Issued 13 March 2007
Resolved
Doors surrounding the galley are listed as A-class self closing doors on the fire plan, but do not meet either specification in construction, possibly compromising the required fire resisting division. Class society must determine required fire resisting division and either update the plan or address correction or doors prior to departure. SOLAS 74 (am) II-2/14.2.1.1.1 / SOLAS 74 (am) II-2/15.2.4
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 13 March 2007
Resolved
Pre-arrival into port check list (company form) is not being completely filled out, indicating a failure to adhere to company required procedure. Address to the satisfaction of class society/flag representative prior to departure. ISM code Part A 7
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 13 March 2007
Resolved
Cargo transfer procedures do not contain all required items, causing all information necessary to not be available to the person in charge of transfer operations.
Documentation › Logs/Records › Oil Record Book
Issued 13 March 2007
Resolved
Entries in oil record book do not use updated codes in force January 1, 2007. Ship's crew claimed they were not informed of this regulatory change by the company. Address to the satisfaction of class society/flag representative prior to departure.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 March 2007
Resolved
Crew reported that eductor system in forward ballast pump room was used routinely to pump accumulated water "down as far as it would go" over the side. Numerous hydraulic leaks in space produced notable quantity of hydraulic oil on deck plates/ on water surface. When questioned, no measure taken to prevent water discharge. Address environmental concern to the satisfaction of class/ flag.
Engineering › Gasoline Engine (propulsion) › Exhaust Outlet (2 stroke)
Issued 13 March 2007
Resolved
Excessive oil has collected under exhaust manifold of main engine; a drip tray has been fitted to directly funnel the oil to the bilges. No reports/actions to correct the cause of oil were made. Address to the satisfaction of class society/ flag representative prior to departure.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 2 May 2006
Resolved
#4 and#6 Cylinder (main Diesel Engine) leaking heavy fuel oil around but not seal head to block.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 2 May 2006
Resolved
Type II sewage System has two temporary repairs on piping, show signs of salt water leakage on inspection port.
Engineering › Steam System (auxiliary) › Valve, Control
Issued 2 May 2006
Resolved
Amount steam valve in purifier room leaking excessively condensate/ steam.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 2 May 2006
Resolved
High pressure fuel oil lines for SSDG"s not properly secured (double Jacket 8 each)
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 2 May 2006
Resolved
#1 SSDG has salt water leak at manifold. 1/4" line sensor
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 May 2006
Resolved
Engine room double bottom tank cover not properly bolted down.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 2 May 2006
Resolved
Engine roonm sludge tank cover not properly bolted down.
Engineering › Bilge Water Management System › Pump
Issued 2 May 2006
Resolved
Ballast pump low level engin room leaking excessively.
Engineering › Fuel Oil Service System › Pump
Issued 2 May 2006
Resolved
Internal fuel oil system transfer pump not properly mounted.
Engineering › Fuel Oil Service System › Pump
Issued 2 May 2006
Resolved
The No. 2 oil transfer pump was found to have been removed from service for repairs while awaiting for spare parts.
Engineering › Freshwater Generation System › Piping
Issued 2 May 2006
Resolved
Fresh water generator piping has soft patch instaled.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 2 May 2006
Resolved
Repair visual alarm steering gear room.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 2 May 2006
Resolved
"Main diesel engine exhaust leaking cooling salt watter on deck bellow.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 2 May 2006
Resolved
Return condensate tank leaking through the side glass.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 2 May 2006
Resolved
Various cargo deck tank cover bolts missing, not properly secured covers.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 2 May 2006
Resolved
The No. 1 port cargo tank, aft out board ullage tube/butterworth cover found with wasted/missing studs, gasket adrift, and leaking cargo and vapors on deck.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 2 May 2006
Resolved
Vessel to conduct an external ISM audit with in 30 days or prior to the next US port after going foreign.
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 4 March 2005
Resolved
Repair inert gas system to address alteration of pressure regulator fuel vavle, automatic capacity control valve. Aslo repair leak at fresh water cooling system for combustion chamber and indicator lights on IGS control panel.
Electrical › Electric Supply System (service) › Cable
Issued 4 March 2005
Resolved
Ensure cargo deck is electrically bonded, many bonding straps were missing or broken, spoll pieces installed with no bonding straps and cargo pipelines not secured to supports on deck.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 4 March 2005
Resolved
Repair numbers 3 and 4 foam tanks where keaking at flange where welded at tank.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 4 March 2005
Resolved
Automatic winch tensioners removed from vessel, provide calls approval of removal or replace
Deck/Cargo › Inert Gas System › Boiler Uptake
Issued 4 March 2005
Resolved
Cargo vapor sensing line banded on some cargo lines with stainless steel straps and rubber, not a permanent arrangement. Properly install vapor sensing line.
Electrical › Lighting (service) › Conductor
Issued 4 March 2005
Resolved
Light on port front of the deck house supported by wires. Provide permanent support as designed.
Deck/Cargo › Ballast › Piping
Issued 4 March 2005
Resolved
Port main seawater manifold after seachest isolating valve found temporary repaired with soft patch and wood plug. Port main seawater manifold after seachest isolating valve to be repaired or replaced, further examined to the satisfaction of the attending classification society rep not later than departure from the next port of call, allegedly Puerto La Cruz, Venezuela
Deck/Cargo › Mooring/Anchoring
Issued 30 December 2002
Resolved
Make permanent repairs to the bow mooring winch
Deck/Cargo › Mooring/Anchoring
Issued 30 December 2002
Resolved
Make permanent repairs to the mooring winch auto tensioners
Fire Fighting
Issued 30 December 2002
Resolved
Make reapirs to the fire pump
Construction/Loadline › Penetrations
Issued 30 December 2002
Resolved
Make permanent repairs to the hydraulic line penetration to the front of the house
Unknown
Issued 5 January 2001
Resolved
Verify compliance with 46 CFR 39.40 and 46 CFR 39.40-3 as per Particular Interest Notice issued by GALMS 11MAY99. Clear Particular Interest Notice when satisfied vessel is in compliance.
Navigation
Issued 12 July 1999
Resolved
INSTALL AUTO PILOT ALARM IAW 33 CFR 157.440 PRIOR TO 12 AUGUST 1999. UNTILTHEN, VSL IS NOT TO OPERATE AUTO PILOT IN U.S. WATERS AND A WARNING LABLE IS POSTED TO NOT OPERATE THE AUTO PILOT IS POSTED AT THE STEERING/CONTROL STATION.
Lifesaving
Issued 12 July 1999
Resolved
PROVE PROPER OPERATION OF PORT LIFE BOAT MDE
Deck/Cargo
Issued 12 July 1999
Resolved
MARK FWD/DECK CARGO PUMP EMERG SHUT DOWN.
Deck/Cargo
Issued 12 June 1998
Resolved
IGS INOPERABLE IN AUTO CONTROL. UNABLE TO COMPLETE AND WITNESS PROPER OPERATION. CASE CLEARED BY NYMCI ON 15JUN98.
Deck/Cargo
Issued 27 August 1996
Resolved
VESSEL IS TO BE ATTENDED BY CLASS SOCIETY DURING LOADING OPERATIONS AT SHELL, DEER PARK, HOUSTON, TEXAS TO ATTEST THEIR SATISFACTION OF RENEWED CARGO PIPING. FAX COPIES OF DNV APPROVAL OF CARGO PIPING TO MSU GALVESTON PRIOR TO VESSEL DEPARTING FROM HOUSTON, TEXAS._x001C_
Deck/Cargo
Issued 16 July 1995
Resolved
Vessel to be attended by class society and provide written statement atesting to proper operation of IGS system before transfer.
Deck/Cargo
Issued 28 April 1994
Resolved
REPAIR HYDRAULIC LEAK IN #4 STARBOARD CARGO PUMP.
Lifesaving
Issued 28 April 1994
Resolved
REPAIR DAMAGED SECTIONS OF FRESH WATER SUPPLY LINE TO THE EMERGENCY EYE WASH STATION, OR INSTALL ALTERNATE EYE WASH UNITS PRIOR TO CARRYING CARGO IN NEXT U.S. PORT.
Accommodation/Occupational Safety
Issued 28 April 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Deck/Cargo
Issued 28 April 1994
Resolved
RESTORE TO PROPER OPERATION #2 PORT P/V VALVE.
Deck/Cargo
Issued 28 April 1994
Resolved
REPAIR LEAK IN #4 STARBOARD COW PUMP CONNECTION.
Documentation
Issued 18 May 1992
Resolved
ANNUAL LOADLINE SURVEY WAS NOT COMPLETED. SURVEY REQUIRED PRIOR TO THE VESSELS NEXT U.S. PORT CALL.
Deck/Cargo
Issued 15 April 1992
Resolved
REPAIR FLAME SCREENS ON NO. 1 CENTER AND NO. 6 STBD CARGO TANK VENTS. ALSOPROVIDE FLAME SCREENS TO VENTS FOR FORWARD PUMP ROOM.
Documentation
Issued 15 April 1992
Resolved
PROVIDE PROOF OF VALID SAFETY EQUIPMENT CERTIFICATE FOR VESSEL PRIOR TO DEPARTING PORT OF NEW ORLEANS, LA. VSL IS RESTRICTED FROM DEPARTING PORT OFNEW ORLEANS, LA. UNTIL PROOF OF VALID SAETY EQUIPMENT CERTIFICATE IS PROVIDED TO THE SATISFACTION FO [name withheld], LA.
Documentation
Issued 12 September 1987
Resolved
PROVIDE DOCUMENTATION ON BOARD FROM THE CLASS SOCIETY THAT THE C.O.W. SYSTEM HAS BEEN SURVEYED AND FOUND IN ACCORDANCE WITH MARPOL AS REQUIRED BY 33CFR157.118.
Documentation
Issued 12 September 1987
Resolved
PROVIDE FINAL APPROVAL BY CLASS SOCIETY OF C.O.W. MANUAL.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.