← All vessels
STARLIGHT 101
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG East District (CGD-E) · Other hulls named STARLIGHT 101
STARLIGHT 101 is a 1986 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1986, most recently in March 2026, along with 113 deficiencies, 2 operational controls and 1 casualty investigation in 2015.
Records from 1986 to 2026. Most recent: inspection, 9 March 2026.
- Built
- 1986
- Last inspected
- 9 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 113 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2015
Identity
697962
WDB5271
268075
Flag
UNITED STATES
366907790
Maury page id
psix-268075
Inspections, by type
…with no type recorded9
Years with a record
39 calendar years (1986–2026)
The 71 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)77.0 ft × 24.1 ft × 8.5 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 30 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDB5271MMSI 366907790 · active · compulsorily equipped · granted 30 August 2023, expires 19 September 2033
WCZ4494MMSI not assigned · expired · voluntarily equipped · granted 12 August 1999, cancelled 17 October 2009 · licensed under a name not among this hull’s recorded names (not shown)
WCO2301MMSI not assigned · expired · compulsorily equipped · granted 26 October 1994, cancelled 1 January 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 71
9 March 2026
Annual Inspection · Administrative Inspection · Internal Structural Exam · Vessel Attendance
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8314274
13 January 2026
Drydock Exam · Internal Structural Exam · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8295032
18 December 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8285294
17 January 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8064937
3 December 2024
Deficiency Check · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8042472
19 September 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7999404
28 August 2023
Annual Inspection · Drydock Exam · In-Service Inspection · Administrative Inspection · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7778763
12 October 2022
Administrative Inspection · COI Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7576081
4 October 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7579133
8 February 2022
Deficiency Check · Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7393052
17 November 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7352720
1 July 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7238198
5 May 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7190325
23 March 2021
Administrative Inspection · In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7166769
31 August 2020
Annual Inspection · Special Consideration
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7048180
3 September 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6803027
13 March 2019
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6641211
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6506070
4 June 2018
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6427361
18 May 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6148959
1 September 2016
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5989227
21 November 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5770225
11 June 2014
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4887938
23 July 2012
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4387639
1 December 2011
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4199206
10 September 2010
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3834970
24 February 2010
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3685556
29 May 2008
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3221115
22 October 2007
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3081814
12 June 2007
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2944431
3 April 2006
Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2615278
2 May 2005
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2347668
26 April 2004
Hull Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2200312
22 May 2003
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1797815
29 April 2002
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1609652
20 March 2002
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1495402
8 November 2001
Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075685
30 July 2001
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1397683
30 March 2000
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1420366
27 March 2000
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1443051
29 April 1999
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1434884
29 June 1998
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1130245
9 March 1998
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 785452
1 August 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 11533
6 May 1997
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1096622
29 April 1997
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1424389
1 May 1996
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1084009
10 April 1996
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1079558
18 March 1996
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 886319
10 January 1996
Plan Review "T" Boat
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1422624
22 September 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 185460
16 September 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 51416
15 July 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 153869
2 May 1995
COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1037754
31 August 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 860646
2 May 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321758
23 March 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 861502
20 May 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1154664
5 May 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1262942
28 April 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1266206
27 April 1991
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1251482
10 April 1990
Deficiency Check · Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 923802
20 November 1989
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1218729
11 April 1989
COI Inspection · Drydock Extension
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 897853
13 April 1988
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 888709
30 September 1987
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319644
12 June 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337810
21 April 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1007579
24 July 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1301177
20 June 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298300
29 April 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992359
Deficiency record · 113
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 March 2026
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, under all practicable conditions. During Annual Inspection it was discovered the bilge pipe cap for the forward compartment was missing, the water that was in forward space was not able to be pumped out. Owner is to replace cap in order for bilge pump to work as designed and to satisfaction of attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 February 2026
Resolved
Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has not completed an annual inspection within the required timeline. Vessel shall not engage in any type of commercial operations until it has under gone an annual inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 December 2025
Resolved
Each vessel inspected and certificated under the provisions of this subchapter must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. Vessel has missed their drydock deadline of 31Oct2025. Vessel is restricted from carrying passengers until drydock credit is given.
46 CFR 176.100(b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 December 2024
Resolved
Life preservers shall be distributed throughout the upper part of the vessel in protected locations. Whenever practicable, life preserver containers should be designed to allow the life preservers to float free in the event of an emergency. MI observed that life preservers were stowed on a shelf secured with wing-nut bolts. The owner/operator shall secure the life preservers in a manner that ensures they can be easily released or accessed for immediate use when needed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 December 2024
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch (psi)at pump outlet. While testing the fire pump, MI observed the pressure gauge at pump did not exceed 30 psi. MI checked the fire hoses and pressure on deck was sufficient to distinguish fire.
Owner/operator shall investigate leakage of water and determine if gauge is broken on pump housing to determine why psi does not exceed 30.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 December 2024
Resolved
A fire hose of sufficient length shall be provided for each fire hydrant, with the vessel requiring two fire hydrants. During fire pump testing, the hoses were activated, and MI observed that one hose had a hole, expelling water, while the other was worn. The owner/operator shall replace the fire hoses to meet the required standards of 46 CFR Sub chapter 181.15-10.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 December 2024
Resolved
This part is intended to provide a minimum standard of regulations for equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock. Each lighting fixture globe must have a guard. MI observed light fixture on deck exposed to elements did not have a guard around globe to protect from hazards. Operator/owner shall place guard around globe to protect from elements/hazards.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2024
Resolved
Electrical equipment on a vessel must be installed installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including ... electric shock. Install blanks blanks on elctical panel in the engine room.
46 CFR 182.200(b)
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 19 September 2024
Resolved
Each ship transporting more than 6 passengers for hire equipped with a radiotelephony station IAW Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: ... the radio operator must hold a marine radio operator permit or higher class license.
47 CFR 80.159(e)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 August 2023
Resolved
46 CFR 176.20-1:No major repairs or alterations affecting the safety of the vessel with regards to the hull, machinery, or equipment, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspection. Failure to report inoperable generators.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 28 August 2023
Resolved
46 CFR 180.175(d):Each life float must be fitted with a lifeline, pendant, two paddles, a painter and a light. During the inspection MIs noticed the Lifelines were rotted, the nets were rotted, the paddles were cracked, and the net attachments were broken. Additionally, life floats were unserviceable. Replace items with new and recondition all life floats to Subchapter Q standard.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 August 2023
Resolved
46 CFR 185.20-35: As appropriate for the intended voyage, all vessels must carry adequate and up to date - (a) charts; (b) sailing directions; (c) coast pilots; (d) light lists; (e) notice to mariners; (f) tide tables; (g) current tables; (h) All other nautical publications necessary. All references onboard are not for this area. Provide current and applicable copies of each.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 August 2023
Resolved
46 CFR 181.10-1: A power driven fire pump shall be intalled on each mechanically propelled vessel. Fire pump is leaking and has salt buildup and corrosion covering seals and outlet, hindering the crew's ability to provide adequate firefighting capabilties. Repair or replace to the satisfaction of Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2023
Resolved
46 CFR 180.75: Each life jacket carried on a vessel on oceans... must have a life jacket light approved IAW 46 CFR 161.012. Most life jacket lights had broken pins. Some of the lights weren't turning on when twisted. Replace all lifejacket lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2023
Resolved
46 CFR 182.25-5(d): The bilge pipe piercing the collision bulkhead shall be fitted with a screw down valve located on the forward side of the bulkhead and operable from above the weather deck. MI observed the valve break when the crew attempted to work the valve. Replace the valve with a proper screw down valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2023
Resolved
46 CFR 180.70 (C) - At least one ring life buoy must be fitted with a lifeline. Lifelines on life buoys were worn and need to be replace IAW subchapter Q.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 August 2023
Resolved
46 CFR 182.530(a) - On a vessel of at least 26 Feet in length, a visual and audible alarm must be provided at the operating station to indicate a high-water level... mid compartment alarm and light weren't operating when switch was activated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2023
Resolved
46 CFR 185.726 (d) - Each battery used in an item of lifesavings equipment must be replaced during the annual inspection if the expiration date of the battery has passed. Some of the Floating lights battery were expire during inspection.Replace batteries before re inspection.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 August 2023
Resolved
46 CFR 185.503 (a) (1) - The master of... a vessel making an oceans or coastwise voyage shall prepare a voyage plan. Master could not provide any logs or records of voyage plans being completed prior to departing. Create new log and ensure is always available for further inspections.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2023
Resolved
46 CFR 183.200 - Electrical equipment on a vessel must be installed and maintained to (b) protect passengers, crew and the vessel from electrical hazards caused by or originating electrical equipment and electrical shock. Breaker panel is missing door. Replace door with new.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 August 2023
Resolved
46 CFR 176.25-50(b) - At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create fire hazards. MI found excessive amounts of oil in the engine room bilge with the suspected source being the starboard generator. Remove all of the oil from the bilge and locate the source of the leak.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 August 2023
Resolved
46 CFR 176.10-5(b) - The marine inspector shall examine all accessible parts of the vessels hull, machinery, and equipment to be assured that they are in a satisfactory condition. MI found the bottom plate in the center section of the lazarette bilge to be pitted at or beyond acceptable ranges as well as severe salt buildup on the bottom plate beneath the starboard propulsion shaft. Clean all affected areas of the bilge and provide a temporary repair proposal to make it to the next scheduled dry dock period at which time all will be cropped and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2023
Resolved
46 CFR 182.01-5(a)(1) - The intent of this part is to ensure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. Port engine shaft seal is wasted and burnt. Repair or replace to the satisfaction of the marine inspector. Starboard generator cooling hoses are ruptured and leaking/rusting out A/C pump components. Starboard generator has a major oil leak coming from the air system, clean and repair. Port generator is inoperable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2023
Resolved
46 CFR 183.05-20(a) - Batteries shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Cover and secure batteries inside of tray.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 August 2023
Resolved
46 CFR 185.604(b) - Each ring life buoy must be marked in clearly legible block capital letters with the vessels name. Port and Starboard side life buoys weren't marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2023
Resolved
46 CFR 180.25-25(a) - Each life preserver carried on a vessel must have at least 200 sq. cm of retro reflective material attached to it. Life jackets retro reflective tape was worn on numerous life jackets. Clean all life jackets and ensure all worn tape is replaced to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2023
Resolved
46 CFR 185.516(a) - Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in a conspicuous place that is readily accessible and visible to the crew and passengers. Placards on board were made for a different type of life jackets. Acquire new placards and post in accordance with the CFR.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 August 2023
Resolved
46 CFR 185.524(d) - Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1)Date of the drill and training; and (2) General description of the drill scenario and training topics. MIs found no evidence of any fire drills being conducted or logged. No logbook was available at the time of inspection. Provide logbook and proof of training.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 August 2023
Resolved
46 CFR 185.520(f) - Abandon ship and man overboard drills and training shall be logged or otherwise documented or ready for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of drill and training; and (2)General description of the drill scenario and training topics. During the inspection, master could not provide drill records for 2023 operations. After further inspection MI was only able to find records rom 2021 and earlier.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 August 2023
Resolved
46 CFR 185.602(g) - On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1-inch numbers and letters at the entranceway to that deck. Acquire and post in accordance with CFR.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 28 August 2023
Resolved
46 CFR 184.702 - A vessel must comply with the applicable design, equipment, personnel, procedures, and record requirements of 33 CFR parts 151,155, and 156. Vessel could not provide a Garbage plan. Create and display garbage plan.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 August 2023
Resolved
46 CFR 16.401(a) - Employee Assistance Program (EAP) education program: Each EAP education program must include at least the following elements: display and distribution of informational material; display distribution of a community service hot-line telephone number for crew member assistance and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Provide EAP.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 August 2023
Resolved
46 CFR 16.203(a)(1) - Employers must ensure that they and their crew members meet the requirements of this part. Drug and alcohol program, 46 CFR 16.203(2) and (3). Provide proof on board of all documentation.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 October 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 October 2022
Resolved
Vessel rep unable to provide DAPI records. Vessel representative stated the records are onboard another vessel. Provide DAPI records and proof of enrollment.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 October 2022
Resolved
Alcohol swabs for testing are expired. Provide new alcohol testing device or testing strips.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 October 2022
Resolved
Medication in first aid kit are expired. Provide new medication/first aid kit in accordance with 46 CFR 160.041.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 October 2022
Resolved
Life floats and paddles are not makred with new vessel name. Ensure all applicable life saving appliances are appropriately marked to include, life floats, life jackets, ring buoys, and EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 October 2022
Resolved
Attachment points for lifelines on life floats are broken. Make repairs to ensure grab lines are properly attached to life floats. Also, replace retro-reflective tape on life floats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 October 2022
Resolved
The high level bilge alarm indicator for engine room is extinguished on the bilge panel by operating station. Replace extinguished bulb for indicator.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 12 October 2022
Resolved
Vessel must conduct satisfactory man overboard and fire drill in the presence of a Coast Guard Marine Inspector prior to the carriage of passengers.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2022
Resolved
Whenever damage or deterioration to the hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the OCMI may conduct an internal structural exam. Due to corrosion and pitting discovered on the hull, vessel is required to assess and provide Sector Mobile a repair proposal for conditions found. Prior to operating, vessel must make appropriate repairs to the satisfaction of a Coast Guard Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 July 2021
Resolved
Combination day/night signals expired. Replace with signals approved under 160.021 prior to carrying passengers after sunset.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 July 2021
Resolved
Life float on port side needs to be remarked with vessel name as it is faded.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 July 2021
Resolved
80-B:C fire extinguisher in engine room is showing in the red. Replace prior to carriage of passengers with a minimum of a 40-B:C extinguisher.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2021
Resolved
Vessel missing 17 adult PFD. Obtain 17 adult PFD type I approved under 160.002, or .005. Mark with vessel name and affix lights approved under 160.112. Vessel limited to voyages as per the COI minus 17 persons.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 April 2021
Resolved
Vessel was due for credit drydock and internal structure exam by 31MAR2021. Prior to carrying passengers complete satisfactory credit drydock exam.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 31 August 2020
Resolved
Each survival craft must be: Secured to the vessel by a painter with a float-free link permanently attached to the vessel. Vessel’s float free weak link was missing for the port side life float and must be replaced. 46 CFR 180.130(a)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 August 2020
Resolved
Each paddle must be of at least 1,220 millimeters (4 feet) in
length, lashed to the life float to which it belongs and buoyant. Paddles for each life float need to be re-lashed to their respective life float.46 CFR 180.175(2)
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 August 2020
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Fire pump pressure gauge was observed as having a 25-30psi range and must be demonstrated to inspectors that it meets the 60psi standard. 46 CFR 181.300(b).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 31 August 2020
Resolved
Each hatch exposed to the weather must be watertight. Vessel’s lazzarette hatch gasket was falling off and needs to be glued into place.46 CFR 171.124 (a).
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 31 August 2020
Resolved
...Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Vessel’s bridge to bridge certificate was expired and must be updated...47 CFR 80.1005.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 August 2020
Resolved
Prior to credit dry dock, (31 MARCH 2021)lazarette will need to be thoroughly cleaned out in order to conduct a proper inspection. 3/16 inch pitting observed, port side, under the wet exhaust. 46 CFR 176.600.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 August 2020
Resolved
Prior to credit dry dock, the vessel must fix their rescue platform to better meet requirements of the 23 OCT 2015 CID note "RESCUE PLATFORMS AS AN ALTERNATIVE TO RESCUE BOATS ON SMALL PASSENGER VESSELS". Specifically, the owner is to address the following issues:
1. Rescue platforms must be sturdy enough to support at least two 185 pound persons, and must be able to withstand the effects of wave action. Current platform is too small.
2.Permanently marked with the vessel’s name and be provided with a suitable storage location.
3. The intended primary platform locations must be readily visible from the operation station and clearly marked “RESCUE ZONE, KEEP CLEAR” in four inch letters of contrasting colors.
Inspectors also suggested to length ladder by 2-3 feet.
46 CFR 180.210(d) / SEC DEL BAY CID NOTE 23 OCT 15
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 August 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel has 135 adult life jackets on board. Vessel is restricted to total passenger count of 135 until life jackets are replaced.46 CFR 180.71(a).
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 September 2019
Resolved
Each item of survival craft equipment must be of good quality and efficient for the purpose it is intended to serve. Top life float on port side is in wasted condition. Pendants are degraded and grab lines are pulling off of the float. Replace life float in kind and provide specification information to marine inspector. Remove float from vessel. Passenger count reduced by 22. 46 CFR 180.175 50C
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2019
Resolved
Each life jacket carried on a vessel on oceans, coastwise or Great Lakes route must have a life jacket light approved in accordance with 161.021 in Subchapter Q. 24 life jackets did not have lights. Attach lights to those 24 life jackets. Passenger count reduced by 24. 46 CFR 180.75 50C
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 September 2019
Resolved
Electric submersible bilge pump in engine room requires shutoff valve at the hull, permanent mounting and meeting UL 1113 requirements. Remove installation from vessel and cap through hull fitting. 46 CFR 182.520 17C
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 September 2019
Resolved
Spanner wrenches must be provided where a 1.5 inch fire hose is require. Provide spanner wrench at each hydrant. 46CFR 181.310 (d) 16C
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 September 2019
Resolved
Clean engine room of accumulated oil, water, other liquids and absorbent pads.
Repair Raw water leak on starboard engine.
Clean hydraulic fluid from bilge of hold space.
Dispose of all waste in accordance with state and local regulations. 46 CFR 176.830 705C SEVEN DAYS
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 September 2019
Resolved
Starboard side fire hydrant valve damaged and not able to be closed. Replace with functioning valve. 46 CFR 181.15-5(c) 16C
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 September 2019
Resolved
Fire pump has been replaced. Fire pump is not self priming and does not have pressure gauge at discharge. Fire pump is not capable of remote starting from operating station. 46 CFR 181.300 50C
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2019
Resolved
Replace broken covers on lights (female head), repair light fixture in vicinity of bait table and make electrical cable safe in the interim. Remove shop lights from engine room that do not have guards on them.
46 CFR 183.01-15(a) 16C
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2019
Resolved
Replace chafed electrical wire in #2 space for air compressor and support w/ appropriate wire hangers. 46 CFR 183.340 50C
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: No static draft information.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 4 June 2018
Resolved
Non metallic piping through a watertight bulkhead must have metallic means of closure/isolation. The PVC Pipes from the engine room to the steering space must be fitted with a metallic valve. 46 CFR 182.40-1(a)
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 June 2018
Resolved
Remove dead-end wires in engine room or properly terminate as required in 46 CFR 183.05-50(a)
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 June 2018
Resolved
Install Guards on forward side of main propulsion engines. 46 CFR 177.35-15
Accommodation/Occupational Safety › Ventilation › General
Issued 18 May 2017
Resolved
Repair all worn vent closures on port and starboard side.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 1 September 2016
Resolved
Repair bilge suction lines for the forepeak and 2nd compartments. Make all bilge suction lines available for inspection.
Communications › Radio Communications › EPIRB
Issued 1 September 2016
Resolved
Provide valid EPIRB registration sticker
Lifesaving › Lifefloat › Serviceable
Issued 1 September 2016
Resolved
Perform maintenance on all lifefloats (paint, mark paddle with vessel name, renew painter and water light line)
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 September 2016
Resolved
Secure hydraulic line in forepeak and make bulkhead penetrations watertight
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 June 2014
Resolved
Two dead end wires on the heaters in the accommodation space starboard side and twist nut type connectors found on starboard side light on the way up to the 2nd deck. Wires must be removed or mad safe.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 June 2014
Resolved
Vessel operated with over 60 children and only had 17 child size PFDs on board. Vessel needs adequate child PFDs for the number of children (weighing less than 90 lbs) on board.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 June 2014
Resolved
Captain did not have proof of a valid FCC Marine operator's permit.
Stability › Incline Test › General
Issued 1 December 2011
Resolved
Based on a new Assumed Average Weight per Person (AAWPP) of 185lbs per person. The new regulations came into effect on December 01, 2011 (Federal Register Vol. 75, No. 239). Based on the new AAWPP your vessel has been restricted to carryiing 128 passengers and 12 crew on LCW warm water route.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 June 2007
Resolved
Prove Master has valid FCC Marine Radio Operator Permit.
Communications › Radio Communications › EPIRB
Issued 12 June 2007
Resolved
Update NOAA EPIRB registration with current call sign.
Fire Fighting › Fire Hydrants › Condition
Issued 12 June 2007
Resolved
Properly label fire stations (port & stbd).
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 14 June 2006
Resolved
Label OCEANS life jackets as such.
Lifesaving › Lifebuoys › Serviceable
Issued 14 June 2006
Resolved
Replace wasted life bouy on port side.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 14 June 2006
Resolved
Remove excessive oil from bilges.
Fire Fighting › Fire Pumps › Capacity
Issued 14 June 2006
Resolved
Repair/Replace inoperable fire pump and prove proper operation of such.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 June 2006
Resolved
Install missing hose clmaps were identified.
Construction/Loadline › Hull › Weld
Issued 14 June 2006
Resolved
Repair broken weld on port amidship cleat.
Engineering › Bilge Water Management System › Piping
Issued 14 June 2006
Resolved
Make permanenet repairs ovbd bilge piping. Remove patch and repair pipe.
Lifesaving › Lifefloat › Paddle
Issued 20 May 2004
Resolved
Stencil the name of the vessel on all lifefloat paddles.
Documentation › Markings/Placards › Garbage Placard
Issued 20 May 2004
Resolved
Provide all placards/postings in wheelehouse with name of the vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 May 2004
Resolved
Secure dead end transducer wire.
Deck/Cargo › Holds/Tanks › Hatch
Issued 20 May 2004
Resolved
Provide secure device to forepeak hatch cover.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 20 May 2004
Resolved
Secure leak at union in way of forward engine room fire pump.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 May 2004
Resolved
Replace fuse rubber insulator in way of starboard engine.
Lifesaving › Lifejacket/PFD (Type III)
Issued 22 May 2003
Resolved
VSL MAX PASSENGER COUNT RESTRICTED TO 143 UNTIL ADDITIONAL LIFEJACKETS ARE PRODUCED.
Navigation › Piloting/Steering
Issued 22 May 2003
Resolved
VSL ROUTE RESTRICTED TO NO MORE THAN 20 NM FROM HARBOR OF SAFE REFUGE THRU 31 MAY 03.
Electrical
Issued 27 March 2000
Resolved
REMOUNT STARBOARD AFT LOUDSPEAKER.
Electrical
Issued 27 March 2000
Resolved
PROVIDE GLOBE FOR OVERHEAD LIGHT OUTBOARD OF STBD MDE.
Electrical
Issued 27 March 2000
Resolved
PROVIDE COVER FOR OPEN JUNCTION BOX ON AFT BKHD IN ENGINE ROOM.
Electrical
Issued 27 March 2000
Resolved
CORRECT IMPROPER WIRING OF JUNCTION BOX, OVERHEAD LIGHT, AND BILGE PUMP IN STEERING COMPARTMENT.
Electrical
Issued 27 March 2000
Resolved
IN THE #2 COMPARTMENT, REMOVE SHATTERED BULB AND PROPERLY REPAIR LIGHT FIXTURE.
Electrical
Issued 27 March 2000
Resolved
REPAIR OR REPLACE PORT AFT FLOODLIGHT AND FLOODLIGHT ON PILOTHOUSE TOP.
Electrical
Issued 27 March 2000
Resolved
IN THE ENGINE ROOM, REPLACE IN KIND THE KNIFE SWITCH ASSEMBLY ON THE STBD MDE.
Lifesaving
Issued 29 April 1999
Resolved
RENEW GRAB LINES ON UPPER DECK RING BUOY.
Electrical
Issued 29 April 1999
Resolved
PROVIDE MISSING BLANK IN CIRCUIT BREAKER BOX IN ENGINE ROOM.
Navigation
Issued 29 April 1999
Resolved
REPLACE OPAQUE LENS ON FWD MASTHEAD LIGHT.
Electrical
Issued 29 April 1999
Resolved
RENEW STUFFING TUBE ON JUNCTION BOX AT BASE OF FWD MAST.
Lifesaving
Issued 29 April 1999
Resolved
REPLACE DETERIORATED RETRO MATERIAL ON LIFE FLOATS.
Lifesaving
Issued 29 April 1999
Resolved
PROVIDE 01 ADDITIONAL ADULT PFD TO BRING TOTAL COUNT TO 162.
Navigation
Issued 29 April 1997
Resolved
VESSEL IS RESTRICTED TO DAYLIGHT OPERATIONS ONLY UNTIL PORT, STARBOARD AND STERN LIGHTS ARE REPAIRED OR REPLACED AND WATCHING PROPERLY._x001C_ _x001C_ _x001C_
Engineering
Issued 18 March 1996
Resolved
REPLACE DETERIORATED FLAME SCREEN IN BOTH FUEL TANK VENTS WITH 30X30 MESH NON-CORROSIVE MATERIAL.
Electrical
Issued 31 August 1994
Resolved
PROVIDE UL 595 APPROVED LIGHT FIXTURES ON THE UPPER DECK OR MAKE INACCESSIBLE TO PASSENGERS AS PER 46CFR183.10-20(L).
Lifesaving
Issued 10 April 1990
Resolved
RENEWED EPIRB BATTERY.
Lifesaving
Issued 10 April 1990
Resolved
REPLACED 2 WORN RING BUOYS.
Casualty record · 1
21 November 2015Routine · role: Involved in a Marine Casualty · 1 dead · activity 5770225
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
ATLANTIC STAR (2015). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.