Records from 1986 to 2025. Most recent: inspection, 13 November 2025.
Inspection history · 86
13 November 2025
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8259841
8 November 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8026637
1 May 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7900068
7 November 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7806867
19 September 2023
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7794478
11 August 2022
Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7507607
3 May 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7425100
8 November 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7343946
27 October 2020
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7073765
22 May 2020
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6952166
14 November 2019
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6845880
17 October 2019
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6834905
20 September 2018
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6517789
28 June 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6492248
8 May 2018
Internal Structural Exam · Examination of Repairs · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6386040
15 August 2017
COI Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6241500
7 November 2016
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6028513
3 May 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5872574
1 October 2015
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5733531
13 May 2014
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4857202
16 May 2012
Hull Examination · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4313743
15 May 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4311875
27 December 2010
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3926185
23 November 2010
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3905065
4 November 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3361407
12 May 2008
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3202444
29 April 2008
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3195190
22 September 2006
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2783917
16 May 2006
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2640596
11 January 2006
Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 2565388
27 September 2005
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2498047
22 September 2004
Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2160655
17 May 2004
Drydock Extension · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2054574
14 November 2003
Plan Review "T" Boat · Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1947910
26 September 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1918203
15 September 2003
Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1901683
12 September 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1671066
7 May 2002
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1611783
12 December 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1077399
17 September 2001
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1384875
23 January 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1465612
12 September 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1427892
14 January 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 814847
6 October 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1194662
13 September 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1372759
13 May 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 164182
20 April 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1432187
21 September 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424661
26 February 1998
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 782030
8 September 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1409750
25 July 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 781845
30 May 1997
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1443907
23 September 1996
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1363828
17 January 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1186553
26 September 1995
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 884009
16 May 1995
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 875130
24 April 1995
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 874978
6 April 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1166397
25 April 1994
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 858301
4 October 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 847510
12 May 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1149606
27 April 1993
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 835331
13 April 1993
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1141166
8 July 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1261428
29 April 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1268324
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 937252
29 August 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1250977
26 June 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1229940
15 May 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227126
1 May 1991
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1229402
24 April 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1239748
15 March 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 919815
26 October 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1230645
5 September 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1210844
11 July 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1211872
2 May 1990
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 910856
19 September 1989
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1305423
2 May 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1040030
11 April 1989
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1205189
11 January 1989
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1045049
6 May 1988
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 889663
10 September 1987
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1314600
26 August 1987
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1031005
19 May 1987
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1028772
27 May 1986
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1292526
22 May 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301834
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 13 November 2025
Resolved
Life floats tethered together using improperly sized line. Tether must be replaced utilizing a length of line that will reach the waterline from the stowage position.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2025
Resolved 13 November 2025
Resolution: life floats were properly tethered.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 November 2024
Resolved
A self priming, power driven fire pump must be installed on each vessel of more than 65 feet in length.
Flexible coupling on discharge side of fire pump is leaking.
46 CFR 181.300(a)(iii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2024
Resolved 26 November 2024
Resolution: Received satisfactory photo/video evidence of new flexible coupling installed and pump running with no leaks.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 19 September 2023
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces.
Vessel shall install system to the satisfaction of attending USCG Marine Inspector.
46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 7 November 2023
Resolution: Vessel representative installed new interconnected fire detection system onboard and was verified by qualified MI during annual inspection.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 September 2023
Resolved
Flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions.
Vessel shall develop plan to the satisfaction of attending USCG Marine Inspector.
46 CFR 185.364
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 7 November 2023
Resolution: Vessel representative developed plan for recharging lithium ion batteries and was verified by qualified MI during annual inspection.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 September 2023
Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section.
Vessels with a keel laid date after March 28, 2022, must include plans for the monitoring device(s) within the plan submissions required in 46 CFR 177.202. The Coast Guard will work with the vessel operators to determine a reasonable implementation schedule once the plans are accepted. The monitoring device(s) must: (1) Ensure the wakefulness of the crew in the event that the watchman required in paragraph (a) of this section is unresponsive; (2) Remain operable during the nighttime watch; and (3) Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards.
46 CFR 185.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 7 November 2023
Resolution: Vessel representative installed monitoring device to ensure wakefulness of watchmen onboard and was verified by qualified MI during annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 11 August 2022
Resolved
Owner/operator shall make sure that survival craft maintenance is carried out in accordance with manufacturers instruction.
One of vessel's lifefloats has minor shell damage, from a recent weather event, exposing foam core.
Make repair to damaged lifefloat to manufacturer's recommendations.
46 CFR 185.702
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 26 August 2022
Resolution: Received photo evidence of proper survival craft repair.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 August 2022
Resolved
Vessel shall be equipped with operational navigation lights in accordance with 33 CFR 83.20.
Vessel's port side, all-around mast, and stern navigation lights were non-operational.
Repair navigation lights prior to conducting voyages during hours of darkness or low visibility due to weather conditions.
33 CFR 83.20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 26 August 2022
Resolution: Received photo evidence of newly purchased navigation light bulbs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 August 2022
Resolved
A marine employer whose vessel is involved in a casualty, likely to become a serious marine incident, shall comply with the requirements of mandatory chemical testing defined by 46 CFR 4.06.
Vessel did not have a method to test for alcohol use onboard.
Vessel is restricted to voyages within a two-hour transit from nearest shore, to meet alcohol testing time requirements, until adequate testing methods are obtained onboard.
46 CFR 185.212
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 26 August 2022
Resolution: Received photo evidence of purchased alcohol testing strips.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 August 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and navigational publications.
Obtain current paper charts and required publications for vessel.
46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 26 August 2022
Resolution: Received photo evidence of purchased new, updated charts.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2020
Resolved
Light and power conductors for interior wiring shall be insulated in accordance with Table 183.05-45(e).
Welding cable found on the generator starting battery. Welding cable does not insulate wire in accordance with Table 183.05-45 (e). Replace with a conductor that complies with 46 CFR 183.340.
46 CFR 183.05-45(e) "Old T"
Action required: 705 - Other - as specified
Due 3 November 2020
Resolved 30 October 2020
Resolution: Welding cable replaced with conductor that complies with 46 CFR 183.340.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 October 2020
Resolved
Water for cooling the exhaust pipe, other than a vertical exhaust shall be injected into the exhaust system as near to the engine manifold as practicable. The water shall pass through the entire length of the exhaust pipe.
Cooling water pipe on the port main engine exhaust found holed and leaking water. Hole measured approximately 1/8" in diameter. Repair or renew as original.
46 CFR 182.20-15 "Old T"
Action required: 705 - Other - as specified
Due 3 November 2020
Resolved 30 October 2020
Resolution: Ownver repaired leak on pipe.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 October 2020
Resolved
Each vessel that operates on an oceans route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Each vessel certificated to operate on a coastwise route within 3 miles of land must either be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board or meet the standard for collision bulkheads and be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board and have onboard a type 1 406 Mhz EPIRB. Each vessel certificated to operate on a limited coastwise route must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board.
Found one 16 person life float and two 22 person life floats with decayed passenger nets. Found two 22 person life floats with worn orange paint and no longer meeting the specifications for color. Renew life floats in accordance with manufacturer specifications and Coast Guard guidance. Total persons onboard on oceans routes reduced to 22 persons. Total persons onboard on coastwise routes inside of 3 miles reduced to 44 persons. Total persons onboard on limited coastwise (less than 20 miles from a harbor of safe refuge) routes reduced to 44 persons.
46 CFR 180.202(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2020
Resolved 28 January 2021
Resolution: Owner repainted and replaced netting for the two 22 person life floats. Owner removed the 16 person life float from vessel and requested to remove it from the COI, reducing total persons allowed to 88.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 October 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible.
Provide up-to-date paper chart of sufficient scale.
46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2020
Resolved 28 January 2021
Resolution: Owner replaced old chart with new chart of sufficient scale dated 29 OCT 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 October 2020
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life ring buoys of not less than 610 millimeters (24 inches) in diameter.
Life ring with lifeline is wasted. Replace life ring buoy.
46 CFR 180.70(a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2020
Resolved 30 October 2020
Resolution: Life ring was replaced.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 14 November 2019
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck.
Submit proposal for the install of adequate emergency lighting in the overnight accommodation space.
46CFR183.432
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2019
Resolved 15 January 2020
Resolution: Owner has not submit proposal for the install of adequate emergency lighting. Removing overnight accommodations from COI until rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Emergency cleaning devices
Issued 14 November 2019
Resolved
Uninsulated parts cannot be inadvertently touched or approached nearer than a safe distance by any person.
Cover electrical knife switch in engine room to protect from shock.
46CFR183.10-10
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 November 2019
Resolved 19 December 2019
Resolution: Owner/operator covered knife switch with hinged rubber matting cover.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 17 October 2019
Resolved
Escape hatch and other emergency exits used as a means of escape must be marked on both sides with at least 2in letters "EMERGENCY EXIT, KEEP CLEAR".
Topside of forward escape hatch was not labeled. 46CFR185.606
Issued CG-835: 705C- vessel shall not carry overnight passengers until escape hatch is labeled.
Action required: 705 - Other - as specified
Resolved 14 November 2019
Resolution: Owner/Operator [name withheld] KEEP CLEAR on both sides of escape hatch.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 September 2018
Resolved
Automatic emergency lighting must actuate upon failure of main lighting system and shall be fitted along line of escape in vessels having lounge areas below the main deck.
Vessel's emergency lighting in overnight accommodation not working. Repair prior to carrying passengers in overnight accommodations. - 46CFR184.30-5(a)
Action required: 705 - Other - as specified
Resolved 17 October 2018
Resolution: Vessel owner replaced battery. Tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 September 2018
Resolved
A vessel on an oceans route must carry 12 red flare distress signals.
Vessel only has 10 flares, provide 2 additional red flare or orange smoke. - 46CFR180.68(a)
Action required: 10 - Deficiency Rectified
Resolved 20 September 2018
Resolution: Corrected on the spot. Rep purchased flares immediately.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 September 2018
Resolved
Vessel must carry first-aid kit with approved contents IAW 46CFR160.041.
Replace expired iodine & add aspirin. - 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2018
Resolved 17 October 2018
Resolution: Vessel owner replaced iodine and asprin.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 September 2018
Resolved
Piping used in a vital system must be composed of ferrous materials or non-metallic piping material IAW 182.720.
Replace as original or as permitted by 46CFR182.720. Provide repair proposal for bilge system and fire main. - 46CFR182.710(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2018
Resolved 20 February 2019
Resolution: Operator made accepted repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 20 September 2018
Resolved
Each hull penetration below the waterline must have means to prevent water from entering vessel. Sewage discharge line has flexible non-metallic hose between hull and valve. Provide repair proposal. Repair prior to 01JUN19. - 46CFR171.119(b)
Action required: 705 - Other - as specified
Due 1 June 2019
Resolved 14 November 2019
Resolution: Owner/Operator made repair as new to sewage piping.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 September 2018
Resolved
Provide proof all employees have read & signed company drug testing policy. - 46CFR16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2018
Resolved 17 October 2018
Resolution: Vessel owner provided required documentation.
Engineering › Bilge Water Management System › Piping
Issued 8 May 2018
Resolved
13104 - All vessels shall be provided with satisfactory arrangement for draining any watertight compartment under all practical conditions. Bilge piping under plywood deck in bunk room is wasted and has holes. Crop and renew. 46 CFR 182.25-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2018
Resolved 25 July 2018
Resolution: Inspected repairs; witnessed satisfactory operational test.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 8 May 2018
Resolved
The hailing port of the vessel must be marked on exterior stern of vessel. Apply hailing port to stern of vessel. 46 CFR 67.123(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2018
Resolved 21 June 2018
Resolution: Operator affixed hailing port to stern.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 August 2017
Resolved
Provide two additional type I adult size life-jackets. Vessel has been reduced to 98 total passengers. IAW 46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 7 September 2017
Resolution: PFD's provided, deficiency cleared.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 August 2017
Resolved
Properly stencil new life-ring IAW 46 CFR 185.604
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 15 September 2017
Resolution: Lifebuoy properly marked, deifiency corrected.
Lifesaving › Lifefloat › Markings
Issued 15 August 2017
Resolved
Provide proof that 16 passenger life-float is CG approved + properly stencil IAW 46 CFR 160.027 *Vessel has been reduced to 82 total passengers when on oceans route.
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 7 September 2017
Resolution: Proof provided, deficiency cleared.
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 August 2017
Resolved
Provide proof of current navagation pubs IAW 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 7 September 2017
Resolution: Proof provided, deficiency cleared.
Communications › Audible Communications › Bell
Issued 15 August 2017
Resolved
Properly install correct size bell IAW 33 CFR 86
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 7 September 2017
Resolution: Bell installed, deficiency cleared.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 August 2017
Resolved
Properly label life-jacket stowage with correct amount of PFD's IAW 46 CFR 180.78
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 7 September 2017
Resolution: Stowage areas properly labeled, deficiency cleared.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 August 2017
Resolved
Remove life-line from lifering that has waterlight.
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 7 September 2017
Resolution: Line removed, deficiency cleared.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 November 2016
Resolved
Replace expired Ammonia Inhalants for First Aid Kit. 46 CFR 160.041-4(b)
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 22 December 2016
Resolution: Resolved, Replaced with new Ammonia Inhalants for First Aid Kit.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 November 2016
Resolved
Show proof of installation of MMSI number in both VHF Radios and ensure both are connected to GPS. CVC 15-06, 8 (a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 22 December 2016
Resolution: Proof of installation of MMSI number shown in both VHF Radios and are connected to GPS.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 November 2016
Resolved
Paint NAV Light Shields flat black as required. NAV RULES, ANNEX I, 6, 84.09 SCREENS (a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 22 December 2016
Resolution: NAV Light Shields painted flat black as required.
Lifesaving › Lifebuoys › Quantity
Issued 7 November 2016
Resolved
Replace STBD FWD Ring Bouy. 46 CFR 180.70
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 22 December 2016
Resolution: STBD FWD Ring Bouy replaced.
Lifesaving › Lifefloat › Paddle
Issued 7 November 2016
Resolved
Stencil NAME OF VESSEL on 16 person life float paddles. 46 CFR 185.604 (g)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 22 December 2016
Resolution: NAME OF VESSEL was Stencil, on 16 person life float paddles as required.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 November 2016
Resolved
Plastic Light Globe of one lifefloat light broken, repair or replace as required. 33 CFR 144.01-10 (b)
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 22 December 2016
Resolution: Replaced
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 November 2016
Resolved
Replace as original Stainless Pipping on STBD Main Diesel Engine discharge cooling water from main engine to exhaust.
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 22 December 2016
Resolution: Replaced
Construction/Loadline › Structures › End Bulkhead
Issued 16 May 2012
Resolved
Crop and renew bulkhead at the FWD lazarette adjacent to sewage tank, 3 penetrations noted on engine room side of bulkhead. IAW CFR176.20-5(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 September 2012
Resolution: Repairs satisfactory.
Construction/Loadline › Penetrations › Pipe Flange
Issued 16 May 2012
Resolved
Crop and renew pipes leading to sewage tank from engine room space, through watertight bulkhead. IAW CFR176.20-5(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 September 2012
Resolution: Repairs satisfactory.
Construction/Loadline › Structures › End Bulkhead
Issued 16 May 2012
Resolved
Forward bulkhead of berthing area, seal screws penetrating bulkhead to make watertight. IAW CFR176.20-5(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 September 2012
Resolution: Repairs satisfactory.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 November 2010
Resolved
Repair/Replace emergency lighting in accommodation space as per 46 CFR 183.30
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2011
Resolution: Emergency lighting in accomodation space has been replaced and is operational.
Documentation › Logs/Records › Logbook (official)
Issued 23 November 2010
Resolved
Provide general description of drills/training in log book as per 46 CFR 185.420
Action required: 705 - Other - as specified
Resolved 24 January 2011
Resolution: [name withheld] e-mailed proof of his drills/training logs to us.
Documentation › Logs/Records › Logbook (official)
Issued 23 November 2010
Resolved
Provide lifesaving equipment maintenance records for life floats as per 46 CFR 185.702
Action required: 705 - Other - as specified
Resolved 12 January 2011
Resolution: Provided maintenance log book to attending Marine Inspector.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 November 2010
Resolved
Provide proof of battery mfgr date of life ring float light. CFR 180.70
Due 30 November 2010
Resolved 18 January 2011
Resolution: New water light with new battery has been installed with atbd side life ring.
Lifesaving › Lifebuoys › Serviceable
Issued 23 November 2010
Resolved
Replace unserviceable starboard ring buoy
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2011
Resolution: Stbd side ring buoy has been replaced.
Engineering › Steering Gear System › Ram
Issued 23 November 2010
Resolved
Repair steering cross bar to prevent striking steering ram.
Due 7 December 2010
Resolved 18 January 2011
Resolution: Steering gear stops have been installed.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 23 November 2010
Resolved
Provide electro-static matting in front of switchboard as per 46 CFR 111.30-11
Due 30 November 2010
Resolved 18 January 2011
Resolution: 24" wide x 36" long and .25" thick electro-static matting with a resistance of 17,000 volts has been installed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 23 November 2010
Resolved
Mark emergency escapes with "emergency exit, keep clear" as per 46 CFR 185.606
Due 30 November 2010
Resolved 18 January 2011
Resolution: Emergency exits have been marked IAW 46 CFR 185.606.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 November 2008
Resolved
Repair weld fracture in Port main diesel engine exhaust pipe @ AFT blkhd.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2008
Accommodation/Occupational Safety › Sleeping Accommodations › Area Per Person
Issued 4 November 2008
Resolved
Repair emergency lighting in accommodation space prior to carrying overnight passengers.
Action required: 705 - Other - as specified
Resolved 12 November 2008
Engineering › Bilge Water Management System › Piping
Issued 22 September 2006
Resolved
Make repairs to bilge piping for FWD void IWO engine room as discussed. You must maintain a portable bilge pump rated for 25 GPM and Higher. Found bilge pipe parted in half just aft of the manifold. POC rented a 65 GPM electrical submersible while repairs are being made.
Condition: Improper/Lack of Maintenance
Due 22 September 2006
Resolved 26 September 2006
Resolution: NEW PIPE THREADED IN PLACE AND TESTED, SAT.
Documentation › Certificates/Documents › FCC SSL
Issued 22 September 2006
Resolved
Provide a FCC Bridge-to-Bridge certificate for vessel.
Condition: Placed in Improper Service
Due 22 October 2006
Resolved 26 September 2006
Resolution: NEW CERTIFICATE ONBOARD.
Lifesaving › Lifefloat › Pendant
Issued 22 September 2006
Resolved
Replace pendants and life line on FWD life float IAW 46CFR160.010(f)&(g). Lines are all wasted from the sun and part with a slight tug.
Condition: Improper/Lack of Maintenance
Due 27 September 2006
Resolved 26 September 2006
Resolution: NEW LINES INSTALLED.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 September 2006
Resolved
Place vessel name on PORT AFT ring buoy and remove lettering that is covering the retro-reflective tape on the FWD STBD ring buoy.
Condition: Improper/Lack of Maintenance
Due 27 September 2006
Resolved 26 September 2006
Resolution: CORRECTED.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 September 2006
Resolved
Prior to overnight passengers, provide emergency lighting IAW 46CFR183.431. Missing emergency light for berthing area.
Condition: Design Flaw
Due 22 September 2006
Resolved 6 October 2006
Resolution: INSPECTED AND TESTED SAT.
Engineering › Fuel Oil Service System › Valve
Issued 27 September 2005
Resolved
Label emergency fuel oil stop valve. Label had fall off.
Condition: Improper/Lack of Maintenance
Due 4 October 2005
Resolved 26 January 2006
Resolution: POC ATTESTED TO COMPLETION
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 September 2005
Resolved
Attach float light to ring buoy as discussed. They had the line tied to the buoy vise using a salt resistant clip.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 October 2005
Resolved 26 January 2006
Resolution: POC ATTESTED TO COMPLETION.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 27 September 2005
Resolved
Provide a work vest and safety line for crewmember during person OVBD drills. They were using a passenger vest which doesn't allow them to move around freely.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2005
Resolved 26 January 2006
Resolution: POC ATTESTED TO COMPLETION.
Lifesaving › Hand Flares › Storage
Issued 27 September 2005
Resolved
Label emergency distress box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2005
Resolved 26 January 2006
Resolution: POC ATTESTED TO COMPLETION.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 27 September 2005
Resolved
Remove line that is holding extinguisher in holder by engine room ladder. They are using a line to hold the extinguisher in place, which would prevent a person from getting to the extinguisher in a timely manner.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 September 2005
Resolved 27 September 2005
Resolution: CORRECTED PRIOR TO MU DEPARTURE.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 September 2005
Resolved
Update all nautical publications and charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2005
Resolved 26 January 2006
Resolution: POC ATTESTED TO COMPLETION.
Lifesaving › Lifefloat › Retroreflective Material
Issued 27 September 2005
Resolved
Replace all retro-reflective tape on lifefloats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2005
Resolved 26 January 2006
Resolution: POC ATTESTED TO COMPLETION.
Engineering › Bilge Water Management System › Interface Detector
Issued 27 September 2005
Resolved
Label all high bilge alarm lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 October 2005
Resolved 26 January 2006
Resolution: POC ATTESTED TO COMPLETION.
Lifesaving › Buoyant Apparatus › Painter
Issued 22 September 2004
Resolved
REPAIR ROTTED SEA PAINTER ON CENTER 15 MAN LIFEFLOAT PRIOR TO CARRIAGE OF PASSENGERS.
Due 22 October 2004
Resolved 22 October 2004
Resolution: Fax Documentation.
Lifesaving › Buoyant Apparatus › Float Free
Issued 22 September 2004
Resolved
INSTALL QUICK RELEASE ARRANGEMENT ON LIFEFLOAT COVERS.
Due 22 October 2004
Resolved 22 October 2004
Resolution: Fax Documentation.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 September 2004
Resolved
INSTALL 6' OF FLOATABLE LINE ON LIFERING WATERLIGHTS.
Due 22 October 2004
Resolved 22 October 2004
Resolution: Fax Documentation.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 22 September 2004
Resolved
INSTALL 15' OF FLOATABLE LINE ON LIFEFLOAT WATERLIGHTS.
Due 22 October 2004
Resolved 22 October 2004
Resolution: Fax Documentation.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 22 September 2004
Resolved
MODIFY EMERGENCY INSTRUCTIONS TO INCORPORATE USE OF RESCUE PLATFORM AND 2-WAY COMMUNICATIONS FOR MAN OVERBOARD RECOVERY.
Due 22 October 2004
Resolved 22 October 2004
Resolution: Fax documentation.
Fire Fighting › Fire Main
Issued 15 September 2003
Resolved
REPAIR LEAK IN FIRE MAIN PIPING AS ORIGINAL PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 22 September 2003
Resolved 15 September 2003
Resolution: PLUG WELD.
Operations/Management › Drug and Alcohol Testing
Issued 15 September 2003
Resolved
PROVIDE CURRENT EMPLOYEE LIST FROM ASAP CHEMICAL TESTING CONSORTIUM. LEGACY COMPONENT DESC: Proof of Enrollment
Due 1 October 2003
Resolved 26 September 2003
Resolution: FAX DOCUMENTATION.
Engineering › Bilge Water Management System
Issued 10 September 2002
Resolved
Provide a high bilge level alarm for the #2 void. LEGACY COMPONENT DESC: High Bilge Level Alarm
Condition: Improper Installation
Due 10 October 2002
Resolved 15 September 2003
Resolution: SAT.
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 September 2002
Resolved
Provide red cross first aid/CPR cards for 50% of crew.
Condition: Unknown
Due 10 October 2002
Resolved 15 September 2003
Resolution: SAT
Navigation › Piloting/Steering
Issued 10 September 2002
Resolved
Provide the required navigational publications. LEGACY COMPONENT DESC: Navigational Publications
Condition: Improper/Lack of Maintenance
Due 11 September 2002
Resolved 12 September 2002
Lifesaving › Hand Flares
Issued 10 September 2002
Resolved
Provide the proper amount of flares. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 11 September 2002
Resolved 12 September 2002
Lifesaving › Lifejacket/PFD (General)
Issued 10 September 2002
Resolved
Replace out dated lights for life preservers as needed. LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Due 11 September 2002
Resolved 12 September 2002
Lifesaving › Lifebuoys
Issued 10 September 2002
Resolved
Replace the retro-reflective tape on all ring life buoys. LEGACY COMPONENT DESC: Retro-reflective tape
Condition: Improper/Lack of Maintenance
Due 11 September 2002
Resolved 12 September 2002
Engineering › Fuel Oil Service System
Issued 10 September 2002
Resolved
Replace flame screens for fuel oil vents. LEGACY COMPONENT DESC: Flame screens
Condition: Improper/Lack of Maintenance
Due 10 October 2002
Resolved 12 September 2002
Engineering › Bilge Water Management System
Issued 10 September 2002
Resolved
Repair and demonstrate all installed bilge pick-up tubes and the operation of same. LEGACY COMPONENT DESC: Bilge system
Condition: Improper/Lack of Maintenance
Due 11 September 2002
Resolved 12 September 2002
Operations/Management › Drills/Instruction
Issued 10 September 2002
Resolved
Provide a platform and means of pulling a person onboard. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Improper/Lack of Maintenance
Due 10 October 2002
Resolved 15 September 2003
Resolution: ATTACHED TO STBD STERN.
Operations/Management › Drills/Instruction
Issued 10 September 2002
Resolved
Demonstrate a person OVBD drill. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 10 October 2002
Resolved 15 September 2003
Resolution: DOCKSIDE DEMO.
Fire Fighting › Fire Hoses
Issued 5 September 2002
Resolved
Replace 1 1/2" fire hose. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 11 September 2002
Resolved 12 September 2002
Fire Fighting
Issued 17 September 2001
Resolved
REPLACE ONE 50' FIRE HOSE PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Documentation
Issued 17 September 2001
Resolved
TEST EPIRB MONTHLY AND PROIPERLY RECORD TEST RESULTS.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Lifesaving
Issued 17 September 2001
Resolved
PROVE PROPER OPERATION OF EPIRB PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Construction/Loadline
Issued 17 September 2001
Resolved
REPAIR/REPLACE HIGH LEVEL BILGE ALARM IN ENGINE ROOM PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Documentation
Issued 17 September 2001
Resolved
CONDUCT MAN OVERBOARD, ABANDON SHIP, AND FIRE DRILL MONTHLY. PROPERLY RECORD DATE OF DRILL AND BRIEF DESCRIPTION OF DRILL AND MAKE AVAILABLE TO COAST GUARD UPON REQUIEST.
Condition: Unknown
Due 17 September 2001
Resolved 17 September 2001
Construction/Loadline
Issued 23 January 2001
Resolved
MAKE PERMANENT REPAIRS TO WASTED BILGE MANIFOLD. RENEW BILGE LINE LEADING FROM MANIFOLD TO PORT FIRE PUMP. RE-MOVE ALL NON MATALLIC PIPING AND RENEWWITH MATALLIC PIPING IAW 46 CFR 182.710 - .730.
Condition: Unknown
Due 23 January 2001
Resolved 23 January 2001
Lifesaving
Issued 13 September 1999
Resolved
REPLACE TWO 100' SEA PAINTER LINES ON LIFE FLOATS PRIOR TO SAILING.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Construction/Loadline
Issued 13 September 1999
Resolved
INSTALL HIGH LEVEL BILGE ALARM IN RUDDER COMPARTMENT.
Condition: Unknown
Due 13 September 1999
Resolved 13 September 1999
Fire Fighting
Issued 21 September 1998
Resolved
INSTALL 15LB CO2 TYPE BII EXTINGUISHER (OR EQUIVILENT) IN CREW ACCOMODATIONSPACE PRIOR TO UTILIZING SPACE FOR PASSENGERS.
Condition: Unknown
Due 23 September 1998
Resolved 22 October 1998
Engineering
Issued 21 September 1998
Resolved
INSTALL MACHINERY GUARDS ON NEWLY INSTALLED BILGE PUMP FORWARD ON PORT MDE.
Condition: Unknown
Due 23 September 1998
Resolved 22 October 1998
Lifesaving
Issued 21 September 1998
Resolved
INSTALL SCREENS ON MSD AND POTABLE WATER VENTS.
Condition: Unknown
Due 23 September 1998
Resolved 22 October 1998
Lifesaving
Issued 21 September 1998
Resolved
PRIOR TO LOADING PASSENGERS INSTALL HYDRPSTATIC RELEASE WITH VALID/CERTIFIED CALIBRATION DATE AND RENEW BATTERY ON EPRIB.
Condition: Unknown
Due 23 September 1998
Resolved 22 October 1998
Lifesaving
Issued 8 September 1997
Resolved
SCHEDULE CG INSP OF EPIRB UPON INSTALLATION OF REPLACEMENT BATTERY.
Condition: Unknown
Due 8 September 1997
Resolved 8 September 1997
Fire Fighting
Issued 8 September 1997
Resolved
SERVICE/HYDRO TEST 15# CO2 F/E'S.
Condition: Unknown
Due 15 September 1997
Resolved 15 September 1997
Electrical
Issued 30 May 1997
Resolved
REPAIR PORTSIDE BATTERY BOX.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Electrical
Issued 30 May 1997
Resolved
REPLACE/REPAIR GENERATOR START CABLES.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Electrical
Issued 30 May 1997
Resolved
REPLACE ALL NON-APPROVED WIRING THROUGH-OUT VESSEL.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Construction/Loadline
Issued 30 May 1997
Resolved
REPAIR REACH ROD FOR VALVE IN FOREPEAK.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Construction/Loadline
Issued 30 May 1997
Resolved
CLAD WELD TWO PITS IN FOREPEAK STBD SIDE SHELL PLATE AND ON COLLISION BLKHD.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Construction/Loadline
Issued 30 May 1997
Resolved
REPAIR CRACKED STANCHION IN BUNKROOM, STBD SIDE.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Electrical
Issued 30 May 1997
Resolved
REMOVE NYLON/PLASTIC WIRE TIES AND REPLACE WITH METALLIC TYPE.
Condition: Unknown
Due 29 August 1997
Resolved 29 August 1997
Construction/Loadline
Issued 30 May 1997
Resolved
CONDUCT CREDIT DRYDOCKING.
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Documentation
Issued 23 September 1996
Resolved
INITIATE EMPLOYER ASSISTANCE PROGRAM.
Condition: Unknown
Due 30 September 1996
Resolved 21 November 1996
Documentation
Issued 23 September 1996
Resolved
PROVIDE MANAGEMENT INFORMATION SYSTEM (MIS) REPORT.
Condition: Unknown
Due 30 September 1996
Resolved 21 November 1996
Lifesaving
Issued 23 September 1996
Resolved
INSTALL RETRO-REFLECTIVE MATERIAL ON LIFE RING BUOYS AND RE-INSTALL ON LIFEFLOATS AS NEEDED.
Condition: Unknown
Due 30 September 1996
Resolved 21 November 1996
Documentation
Issued 23 September 1996
Resolved
INITIATE EPIRB MAINTENANCE AND CREW TRNG LOG.
Condition: Unknown
Due 30 September 1996
Resolved 21 November 1996
Lifesaving
Issued 26 September 1995
Resolved
Replace 119 adult pfd's total persons allowed onboard shall not exceed 21.
Condition: Unknown
Due 3 October 1995
Resolved 18 January 1996
Lifesaving
Issued 26 September 1995
Resolved
Stencil all adult pfd's with vessel name and install a light on each.
Condition: Unknown
Due 3 October 1995
Resolved 18 January 1996
Lifesaving
Issued 26 September 1995
Resolved
Restencil life float paddles with vessels name.
Condition: Unknown
Due 3 October 1995
Resolved 18 January 1996
Construction/Loadline
Issued 26 September 1995
Resolved
Crop and renew bilge dishcharge in way of wastage starboard engine bilge pump discharge.
Condition: Unknown
Due 3 October 1995
Resolved 18 January 1996
Electrical
Issued 26 September 1995
Resolved
Replace battery in engine room emergency light.
Condition: Unknown
Due 3 October 1995
Resolved 18 January 1996
Lifesaving
Issued 25 April 1994
Resolved
Replace 8 paddles in 4 lifefloats.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Engineering
Issued 25 April 1994
Resolved
Install 30 x 30 mesh flame screen in both fuel tank vents.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Electrical
Issued 27 April 1993
Resolved
Remove or reconnect abandoned electrical cable in engine room vent trunk.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Electrical
Issued 27 April 1993
Resolved
Provide proper electrical connection for wash down pump.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Electrical
Issued 27 April 1993
Resolved
Reattach electrical cable to mast head light.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Fire Fighting
Issued 27 April 1993
Resolved
Mount fire extinguisher inthe engine room.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Electrical
Issued 27 April 1993
Resolved
Hard wire/mechanically connect "Rule" bilge pumps to eliminate wire nuts.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Navigation
Issued 13 April 1993
Resolved
Renew hydraulic steering piping between both main engines and hydryaullic reservoir.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Construction/Loadline
Issued 13 April 1993
Resolved
Reweld bottom portion of deck support stanchion in #3 hold.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Construction/Loadline
Issued 13 April 1993
Resolved
Reweld eroded weld on stbd side-transverse butt just out board of keel, weld length approx 2 inches.
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Construction/Loadline
Issued 13 April 1993
Resolved
Drill stop and reweld crack on after portion of keel.
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Fire Fighting
Issued 29 April 1992
Resolved
Provide adequate length of hoses for hand pump and prove operation.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Navigation
Issued 29 April 1992
Resolved
Prove operation of single side band radio.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Lifesaving
Issued 29 April 1992
Resolved
Provide approved EPIRB.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Lifesaving
Issued 29 April 1992
Resolved
Replace battery in water light for lifefloat.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Construction/Loadline
Issued 29 April 1992
Resolved
Label access cover to bilge manifold valves and clean ID labels for valves.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Engineering
Issued 29 April 1992
Resolved
Clean or replace fuel vent screens.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Lifesaving
Issued 1 May 1991
Resolved
RENEW ALL PENDANTS ON LIFE FLOATS (ALL 5) WITH BLACK POLYPROPELENE. TO BE COMPLETED PRIOR TO EXCEEDING 20 MILES.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Lifesaving
Issued 1 May 1991
Resolved
RENEW LINES FROM FLOAT TO PAINTER - BLACK POLY. (TWO). TO BE COMPLETED PRIOR TO EXCEEDING 20 MILES.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Documentation
Issued 1 May 1991
Resolved
RENEW FCC STATION LICENSE BY 26JUN91.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Lifesaving
Issued 1 May 1991
Resolved
RENEW PFD LIGHTS AS FOLLOWS: 2 BY 31MAY91_x001C_ 3 BY 31AUG91_x001C_ 1 BY 30SEP91
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Lifesaving
Issued 1 May 1991
Resolved
RENEW PAINTERS (THREE). TO BE COMPLETED PRIOR TO EXCEEDING 20 MILES.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Lifesaving
Issued 1 May 1991
Resolved
PROVIDE A SUITABLE RESCUE PLATFORM OR RESCUE BOAT.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Documentation
Issued 1 May 1991
Resolved
RENEW FCC RADIOTELEPHONY CERTIFICATE BY 22MAY91. RESTRICTED TO 1000 FEET FROM LAND UNTIL COMPLETED.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Lifesaving
Issued 5 September 1990
Resolved
D. LIFEFLOAT COVERS CANNOT BE LASHED TO DECK. USE ELASTIC. ITEMS A THRU D TO BE COMPLETED DAILY UNTIL MASTER HAS LEARNED TO MAINTAIN EQUIPMENT.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Navigation
Issued 5 September 1990
Resolved
REPAIR SSB RADIO PRIOR TO EXCEEDING 20 MILES FROM A HARBOR OF SAFE REFUGE.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Lifesaving
Issued 5 September 1990
Resolved
MAINTAIN THE FOLLOWING AT ALL TIMES: A. FIRE HOSES TO BE ON STATION. B. LIFEFLOAT AND RING BUOY LIGHT TO BE ATTACHED AND IN HOLDERS AT ALL TIMESC. LADDER TO UPPER DECK TO BE ONBOARD AT ALL TIMES.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Lifesaving
Issued 5 September 1990
Resolved
PROVIDE 2 PADDLES STENCILED WITH VESSEL NAME LASHED TO LIFEFLOAT (CENTER FLOAT) PRIOR TO 06SEP90.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Construction/Loadline
Issued 2 May 1990
Resolved
INSTALL CAPTIVE CHAIN ON AFT DECK HATCH.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990
Resolved
RENEW FLOAT-FREE LINK ON 15 PERSON LIFE FLOAT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990
Resolved
RENEW EPIRB BATTERY PRIOR TO OPERATING OCEANS ROUTE.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Documentation
Issued 19 September 1989
Resolved
CREDIT DRYDOCK DUE 19MAR91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 19 September 1989
Resolved 19 September 1989
Fire Fighting
Issued 6 May 1988
Resolved
PROVIDE ONE LENGTH OF 1 1/2" X 50 OF UL LINED FIRE HOSE PRIOR TO CARRYING PASSENGERS FOR HIRE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Engineering
Issued 19 May 1987
Resolved
RELOCATE REMOTE CONTROLS FOR FUEL SHUT OFF VLAVES TO OPERATE FROM OUTSIDE THE ENGINE ROOM.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987