← All vessels
CHAMPION ADRIATIC
CHAMPION ADRIATIC is a 1982 tank ship. The Coast Guard has recorded 41 inspections since 1986, most recently in January 2010, along with 24 deficiencies — 1 with no resolution recorded — and 6 operational controls.
Records from 1986 to 2010. Most recent: inspection, 8 January 2010.
- Built
- 1982
- Last inspected
- 8 January 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8005771 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LADE6
268100
Flag
LIBERIA
—
Maury page id
psix-268100
Inspections, by type
…with no type recorded22
…past their stated due date1
Years with a record
17 calendar years (1986–2010)
The 41 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it21963 - Convention (Subpart B), Gross Ton
47514 - Displacement, Ton
37658 - Dead Weight, Ton
12126 - Convention (Subpart B), Net Ton
47514 - Displacement, Ton
37658 - Dead Weight, Ton
12126 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 41
8 January 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3661137
8 January 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3661159
6 January 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3659559
1 January 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3664718
29 December 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3656214
23 December 2009
ISPS I Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3652437
18 December 2009
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3652414
19 March 2009
PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3436702
22 August 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3305004
22 August 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3306262
18 August 2008
COC-CHEM Renew · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3298342
15 January 2008
ISPS III Exam · Ballast Water Examination · MARPOL Annex II Examination · MARPOL Annex V Examination · PI Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3130668
15 January 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3130680
15 January 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3130909
12 December 2007
ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3114560
9 July 2006
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2707102
5 July 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2702988
9 June 2006
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2723753
9 October 2004
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2217105
5 April 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 415400
14 March 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 415242
14 March 1998
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1123852
28 October 1996
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 396859
15 March 1995
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1174661
20 April 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 366274
20 April 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 669229
8 March 1994
Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 854602
6 October 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 493105
7 February 1993
Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 825860
12 October 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 346504
12 October 1991
Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 936774
18 June 1990
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 337664
16 June 1990
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1237508
18 May 1989
Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1207539
16 May 1989
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 330401
29 January 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 439875
29 January 1988
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1323762
23 July 1987
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1328571
22 July 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 317478
30 May 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 309119
30 May 1986
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 989562
Deficiency record · 24
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 March 2009
Resolved
Electrical junction boxes in cargo pump room are not intrinsically safe. Packing glands are not seated properly exposing wire.
Engineering › Pressure Vessel › Rupture Disks
Issued 19 March 2009
Resolved
Thermostatic valve for hydraulic power pack is weeping due to faulty o-ring. Approximately .25 litres lost.
Deck/Cargo › Cargo Heating › General
Issued 19 March 2009
No resolution recorded
Steam blowing connection for cargo steam line IWO #4 C tank is cracked at connection. Cracked line is allowing steam to escape.
Navigation › Piloting/Steering › Gyro Compass
Issued 22 August 2008
Resolved
Vessel's Gyrocompass found INOP; degrees are off by 5.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 22 August 2008
Resolved
1820-cargo pump room- Items were found in the Cargo Pump Room contributing to a 2 hour stoppage in cargo ops; A. Cargo leaks from the bypass sample valves on #1, #2 & #3 COTP's. B. #4 COTP strainer drain leakage. C. #4 COTP bypass valve leakage. D. Broken valve bodies on #3 COTP drain valve & #2 COTP bypass valve. E. Missing Isolation valve handles for pressure sensors on #2 & #5 COTP's. (17 a/b)
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 22 August 2008
Resolved
1830- Cargo transfer- Items found at or near port & stbd cargo manifolds contributing to a 2 hour stoppage of cargo ops. A. #2 cargo valve leaking aft of Port & Stbd manifolds. B. Unidentified & untested cargo hose connected at the port manifold. C. Leaks at the stbd manifold flanges on jumpers for #5 Port & Stbd, fwd & aft,. D. Hydraulic leaks from the Framo pump heads #3 Port & #5 Stbd. (17a/b)
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 22 August 2008
Resolved
0715-Detection-Smoke detection head was missing at the lower level of the pump room. Class to verify repairs and satisfactory operation of the system. records indicate system was checked on 16 Aug 08. (17a/b)
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 22 August 2008
Resolved
0699-Other- life saving- One of the two required stretchers to be carried onboard is missing & not onboard. (15c)
Documentation › Markings/Placards › Injury Placard
Issued 22 August 2008
Resolved
0900- Safety in general- Emergency eye wash / showers not identified IAW 46 CFR 153.216 (10)
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 22 August 2008
Resolved
0100- Cargo Transfer Procedures donot meet the requirements of 33CFR 155.720. Template provided to master. (10)
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 18 August 2008
Resolved
Main engine has water leak on number two cylinder. Actively leaking while secured. Crew states system does not leak when running. Must be rectified prior to next U.S. port after sailing foreign, to the satisfaction of classification society.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 August 2008
Resolved
Engine room ventilation duct above sewage system has been modified. Modification must be approved by classification society surveyor prior to next U.S. port after sailing foreign.
Engineering › Steam Boiler (propulsion) › Combustion Air System
Issued 18 August 2008
Resolved
Boiler start-up exhaust emissions appeared to contain excesive particulates, which crew attributed to improper fuel/air ratio. Class society surveyor must inspect the system prior to cargo operations.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 15 January 2008
Resolved
The control air solenoid which activates a plunger for the main fuel pump had moisture inside causing the plunger to close and stop all fuel flow to the engine.
Fire Fighting
Issued 14 March 1998
Resolved
While visually inspecting the living spaces, it was observed that the door handle for the air duct and electrical wiring trunk on the upper deck was missing which reduced the fire resistance. Specific Cite: Solas 74 Unamended CH.II-2/Reg.57(b)(i)._x001C_
Fire Fighting
Issued 14 March 1998
Resolved
While visually inspecting the living spaces, it was observed that the class"A" self closing doors to the bridge and radio room were held open by hooks. Specific Cite: Solas 74 unamended CH.II-2/Reg. 57(b)(vii)._x001C_ _x001C_
Electrical
Issued 14 March 1998
Resolved
While conducting a deck walk, it was observed that the J box cover for the kingpost outboard light located at the 1st platform was wasted. Specific Cite: Solas 74 unamended CH.II-1/Reg.27(i)(1)._x001C_ _x001C_
Electrical
Issued 14 March 1998
Resolved
While conducting a vessel deck walk, it was observed that the switch box cover for the starboard liferaft lighting was wasted/damaged, exposing the internal wiring. Specific Cite: Soals 74 unamended CH.II-1/Reg.27(i)(1)._x001C_ _x001C_
Deck/Cargo › Ballast › Tank
Issued 14 March 1998
Resolved
Inspection of the cargo pump room and the mid-body ballast tank were not _x001C_ available for inspection due to no gas free certificate. Specific Cite: COMDTINST and 46 CFR subchapter D._x001C_ _x001C_
Fire Fighting
Issued 14 March 1998
Resolved
While visually inspecting the living spaces, it was observed that the door handle for the air duct and electrical wiring trunk was missing reducing fire resistance. Specific Cite: Solas 74 unamended CH.II-2/Reg.57._x001C_ _x001C_
Fire Fighting
Issued 14 March 1998
Resolved
While visually inspecting the living spaces, it was observed that several of the stairwell doors were not self closing. Specific Cite: Solas 74 unamended CH.II-2/Reg.57(b)(vii)._x001C_ _x001C_
Lifesaving
Issued 14 March 1998
Resolved
While visually inspecting the lifeboats, it was observed that the guard rail located at both embarkation areas were broken/missing reducing the safety of the crew. Specific Cite: ICLL-66 Annex I/Reg.25._x001C_ _x001C_
Lifesaving
Issued 14 March 1998
Resolved
While visually inspecting the vessel's lifeboats, it was observed that the forward grab rail on the starboard lifeboat was damaged, thereby preventingits use if needed. Specific Cite: Solas 74 unamended CH.III/Reg.4(c).
Unknown
Issued 20 April 1994
Resolved
Vessel's master did not report that the vessel's gyrocompass had failed prior to entering the port of Guam.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.