← All vessels
DOLPHIN
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Oceania District (CGD-O) · Other hulls named DOLPHIN
DOLPHIN is a 1985 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1986, most recently in April 2023, along with 72 deficiencies and 1 operational control.
Records from 1986 to 2023. Most recent: inspection, 27 April 2023.
- Built
- 1985
- Last inspected
- 27 April 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 72 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
WDE3655
268119
Flag
UNITED STATES
—
Maury page id
psix-268119
Inspections, by type
…with no type recorded4
Years with a record
33 calendar years (1986–2023)
The 65 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it5 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 65
27 April 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7679917
4 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7442862
28 April 2021
COI Inspection · Drydock Exam · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7184879
21 May 2020
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6961298
29 April 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6945749
2 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6675599
7 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6408186
12 April 2018
Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6391325
10 May 2017
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6145135
12 May 2016
DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5923076
21 April 2016
Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5886072
15 May 2014
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4870228
1 July 2009
Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3520464
5 May 2009
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3475238
5 May 2008
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3199697
9 May 2007
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2926162
22 April 2007
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2913350
18 April 2007
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2910598
12 October 2006
Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2802012
11 May 2006
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2646764
5 May 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2674482
9 June 2005
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2384967
16 September 2004
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2197438
19 July 2004
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2155041
21 April 2004
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2048849
27 August 2003
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1889338
27 May 2003
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1803391
5 June 2002
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1623881
29 April 2002
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1610440
23 May 2001
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1366361
31 August 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1053845
15 June 2000
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1415387
25 April 2000
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361399
27 September 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1039809
1 July 1999
Re-Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361007
22 September 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 212406
3 August 1998
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 795810
4 June 1998
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1467984
22 May 1998
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 791704
3 April 1998
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372202
4 June 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1406119
5 June 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1411307
1 May 1996
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380501
27 November 1995
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 880749
5 October 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358940
12 July 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1360214
8 June 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1407499
3 August 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359893
2 May 1994
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1431355
3 June 1993
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1136781
6 May 1993
Deficiency Check · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 840410
10 June 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1267329
8 May 1992
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 943813
10 May 1991
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1233034
6 February 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 908191
19 November 1990
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1238149
19 June 1990
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 929197
19 June 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1350556
23 May 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1032574
12 May 1989
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1206617
21 July 1988
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1041461
11 May 1988
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1199996
8 December 1987
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1312716
7 May 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1028235
20 May 1986
Credit Drydock · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1294223
Deficiency record · 72
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 May 2022
Resolved
A pre-engineered fixed gas fired extinguisher system must have a light to indicate discharge and an audible alarm that sounds upon discharge. Audible alarm was not functioning as designed. Provide new audible alarm.
46 CFR 181.420(b)
Personnel › Training › First Aid/CPR
Issued 5 May 2009
Resolved
Re-certify at least 50% of crew in first aid/CPR
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 May 2009
Resolved
Provide Aspirin for first aid kit.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 May 2009
Resolved
Reinforce railing on stbd side foremost stanchion and aftmost.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 5 May 2009
Resolved
Make permanent repairs to non-approved cut-outs in engine space boundary.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 5 May 2009
Resolved
Non-metallic fuel hose passes through the bulkhead to the fuel tanks.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 5 May 2009
Resolved
Vessel is an inboard gas engine with portable fuel tanks permanently affixed to the fuel supply lines.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2006
Resolved
Remove and replace all expired medication and provide a wire splint for the first aid kit.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 May 2006
Resolved
Trace all electrical wiring and remove all loose wires or dead-end all loose wiring into junction boxes.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 11 May 2006
Resolved
Replace or remove fractured bridge windshield.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 19 July 2004
Resolved
Comply with engine room ventilation requirements as per 46 CFR 182.460
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 27 August 2003
Resolved
Replace S/W implellor and prove proper operation of engine to CG marine inspector.
Electrical › Electrical Distribution System (service)
Issued 27 May 2003
Resolved
Remove or properly repair dead end wires located at operating station. LEGACY COMPONENT DESC: Wiring
Electrical › Electrical Distribution System (service)
Issued 27 May 2003
Resolved
Provide metal supports for wiring IAW 46CFR183.340. LEGACY COMPONENT DESC: Wiring
Engineering › Bilge Water Management System
Issued 27 May 2003
Resolved
Provide bilge pump discharge hoses IAW 46CFR177.900(g). LEGACY COMPONENT DESC: Hose
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 27 May 2003
Resolved
Rejected (2) adult lifejackets. Lifejackets tore apart easily without effort. Vessel provided (2) CG approved adult lifejackets.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 June 2002
Resolved
Ring buoy missing 3ft lanyard.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 June 2002
Resolved
Rejected 2 CG approved lifejackets.
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 June 2002
Resolved
US Coast Pilot.
Construction/Loadline › Hull
Issued 29 April 2002
Resolved
Repair 1 inch crack in FRP stbd side aft. LEGACY COMPONENT DESC: Side Shell
Construction/Loadline › Hull
Issued 29 April 2002
Resolved
Replace missing bolt for stainless steel bracket located on transom. LEGACY COMPONENT DESC: Bracket
Construction/Loadline › Structures
Issued 29 April 2002
Resolved
Repair combing for non-watertight door located at operating station. LEGACY COMPONENT DESC: Superstructure
Pollution Prevention/Response › Prevention Equipment
Issued 29 April 2002
Resolved
Replace handles on bilge discharge valves. Located in engine room. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Electrical › Electrical Distribution System (service)
Issued 29 April 2002
Resolved
Remove dead end wires located at operating station. LEGACY COMPONENT DESC: Wiring
Construction/Loadline › Structures
Issued 29 April 2002
Resolved
Repair weld for stanchion on bimany top starboard side. LEGACY COMPONENT DESC: Superstructure
Engineering
Issued 15 June 2000
Resolved
Provide fuel tank & plans that meet 46CFR182.440 or provide portable tanks as per original vessel plans NLT 13JUL00.
Lifesaving
Issued 1 July 1999
Resolved
RENEW ONE CHILD LIFE JACKET. VESSEL RESTRICTED TO CARRYING NOT MORE THAN TWO CHILDREN UNDER 90 LBS UNTIL IN COMPLIANCE.
Fire Fighting
Issued 1 July 1999
Resolved
PROVIDE FIXED FIRE EXTINGUISHING AND DETECTING SYSTEM FOR ENGINE ROOM AS REQUIRED BY 46 CFR 181.400 OR 46 CFR 181.420.
Documentation
Issued 1 July 1999
Resolved
PROVIDE PROOF OF TRAINING FOR DRUG TESTING PROGRAM AND EAP HOTLINE NUMBER.
Construction/Loadline
Issued 1 July 1999
Resolved
AFT BILGE PUMP NOT OPERATING. PROVE PROPER OPERATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Lifesaving
Issued 4 June 1998
Resolved
Found retro material on 13 of the life jackets inspected, old, non- reflective and falling off. Required retro material on the 13 life jacketsthat failed inspection be replaced.
Construction/Loadline
Issued 4 June 1998
Resolved
Found engineroom mechanical exhaust ducting was made out of plastic dryer hose. Required replacement of engineroom machanical exhaust ducting with the same material as the hull or of noncombustible material IAW 46 CFR 182.465(d).
Lifesaving
Issued 4 June 1998
Resolved
Found no emergency procedures placard posted. Required emergency procedures placard to be posted.
Construction/Loadline
Issued 3 April 1998
Resolved
Make proper repairs to fracture port side 14' aft of bow 2' above waterline. Repairs to made in accordance with NVIC 8-87.
Lifesaving
Issued 1 May 1996
Resolved
Provide life jacket placards in accordance with IFR 46 CFR 185.516.
Lifesaving
Issued 1 May 1996
Resolved
Install retroreflective tape on ring buoy in accordance with IFR 46 CFR 185.604(i).
Lifesaving
Issued 1 May 1996
Resolved
Provide documentation of abandon ship and man overboard drills and trainingin accordance with IFR 46 CFR 185.520.
Fire Fighting
Issued 1 May 1996
Resolved
Provide documentation of fire fighting drills and training in accordance with IFR 46 CFR 185.524.
Documentation
Issued 1 May 1996
Resolved
Provide pre-employment negative drug test results or evidence of previouslybeing subject to random drug testing for 12 months for new employees in_x001C_ accordance with 46 CFR 16 prior to operating in a covered position.
Documentation
Issued 1 May 1996
Resolved
Provide evidence of random drug testing frequency and selection process such that an employee's chance of selection exists throughout employment inaccordance with 46 CFR 16.
Engineering
Issued 1 May 1996
Resolved
Provide drip pan for fuel filter in accordance with 46 CFR _x001C_ 182.15-40(b)(5).
Electrical
Issued 1 May 1996
Resolved
Provide portable battery lights at operating station and access to propulsion machinery space in accordance with IFR 46 CFR 183.430.
Navigation
Issued 1 May 1996
Resolved
Provide compass light in accordance with IFR 46 CFR 184.402.
Navigation
Issued 1 May 1996
Resolved
Provide emergency broadcast placard in accordance with IFR 46 CFR 184.506.
Engineering
Issued 1 May 1996
Resolved
Provide two independent means of controlling each propulsion engine in accordance with IFR 46 CFR 184.620.
Lifesaving
Issued 1 May 1996
Resolved
Provide documentation of crew training in accordance with IFR 46 CFR 185.420.
Lifesaving
Issued 1 May 1996
Resolved
Provide documentation of passenger count in accordance with IFR 46 CFR 185.504.
Lifesaving
Issued 1 May 1996
Resolved
Provide passenger safety orientation in accordance with IFR 46 CFR 185.506.
Fire Fighting
Issued 12 July 1995
Resolved
INSTALL FIXED FIRE EXTINGUISHING SYSTEM IN ACC. W/ 46 CFR 181.20.
Lifesaving
Issued 8 June 1995
Resolved
RENEW RETROFLECTIVE TAPE ON 15 ADULT AND 3 CHILD SIZE PFDS, ALSO CLEAN AND_x001C_REPAIR THE PFDS AS NEEDED AND PROVIDE FOR INSPECTION.
Construction/Loadline
Issued 8 June 1995
Resolved
PROVIDE PROPER HIGH WATER ALARM FOR UNATTENDED MACHINERY SPACE.
Construction/Loadline
Issued 8 June 1995
Resolved
PROVIDE PROPER INDIVIDUAL OPERATION INDICATING LIGHT, AT OPERATING STATION,FOR EACH BILGE PUMP.
Fire Fighting
Issued 8 June 1995
Resolved
PROVIDE PROPER MANUAL VENT CLOSURES FOR MACHINERY SPACE.
Fire Fighting
Issued 8 June 1995
Resolved
PROVIDE PROPER INSTALLATION OF FIXED HALON BOTTLE FIRE EXTINGUISHING SYSTEM, IAW NVIC 8-87.
Documentation
Issued 10 June 1992
Resolved
PROVIDE CURRENT FCC-824, SAFETY RADIOTELEPHONE CERTIFICATE FOR VESSEL.
Documentation
Issued 10 June 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline
Issued 19 November 1990
Resolved
MAKE PERMANENT REPAIRS TO THE DELAMINATED DECK AT THE BOW PRIOR TO CARRYINGPASSENGERS.
Construction/Loadline
Issued 19 November 1990
Resolved
COMPLETELY PLUG ALL DRAIN HOLES IN THE HULL PRIOR TO CARRYING PASSENGERS.
Construction/Loadline
Issued 19 November 1990
Resolved
MAKE PROPER REPAIRS TO THE DELAMINATED AREA OF THE DECK AT THE TRANSOM PRIOR TO CARRYING PASSENGERS.
Construction/Loadline
Issued 19 November 1990
Resolved
MAKE SATISFACTORY REPAIRS TO THE DELAMINATED FIBERGLASS ON THE INTERIOR HULL ABOVE THE MAIN DECK PRIOR TO CARRYING PASSENGERS.
Accommodation/Occupational Safety
Issued 19 November 1990
Resolved
MAKE PERMANENT REPAIRS TO THE CAPRAIL LOCATED ON THE PORT AND STARBOARD BOARDING AREA PRIOR TO CARRYING PASSENGERS.
Documentation
Issued 19 June 1990
Resolved
POST EMERGENCY PROCEDURES
Fire Fighting
Issued 19 June 1990
Resolved
PROVIDE PROOF OF SERVICING OF PORTABLE FIRE EXTINGUISHING EQUIPMENT AND FI FIXED EXTINGUISHING SYSTEM
Construction/Loadline
Issued 12 May 1989
Resolved
PROVIDE AN OVERBOARD DISCHARGE FOR THE VESSEL'S ELECTRIC BILGE PUMP.
Construction/Loadline
Issued 12 May 1989
Resolved
PERMANENTLY SEAL ALL DRAIN HOLES IN THE HULL LOCATED IN WAY OF THE MAIN DECK.
Construction/Loadline
Issued 12 May 1989
Resolved
PROVIDE A SUITABLE INSPECTION PLATE IN THE COMPARTMENT AFT OF THE CHAIN LOCKER AND OPEN IT UP FOR INSPECTION.
Engineering
Issued 12 May 1989
Resolved
INTERLOCK THE EXHAUST BLOWER WITH THE STARTING SWITCH SO THAT THE BLOWER ISSTARTED BEFORE THE ENGINE IGNITION IS ENERGIZED. A RED WARNING SIGN AT THE SWITCH SHALL STATE THAT THE BLOWER BE OPERATED PRIOR TO STARTING THE ENGINETO ALLOW AT LEAST ONE COMPLETE AIR CHANGE BEFORE STARTING THE ENGINE.
Lifesaving
Issued 12 May 1989
Resolved
PROVIDE THREE ADDITIONAL RED HAND FLARES AND FIVE ADDITIONAL ORANGE SMOKE SIGNAL DEVICES PRIOR TO CARRYING PASSENGERS.
Navigation
Issued 12 May 1989
Resolved
MOUNT A SUITABLE MAGNETIC COMPASS AT THE STEERING STATION.
Lifesaving
Issued 12 May 1989
Resolved
PROVIDE ONE ADDITIONAL ADULT LIFE PRESERVER. TOTAL PASSENGERS ALLOWED IS REDUCED TO 23 UNTIL THIS REQUIREMENT IS SATISFIED.
Lifesaving
Issued 11 May 1988
Resolved
PROVIDE 1 CHILD AND 6 ADULT TYPE I PERSONAL FLOATATION DEVICES (PFD'S). OPERATION IS RESTRICTED TO 20 PASSENGERS UNTIL ABOVE REQUIREMENT IS MET.
Construction/Loadline
Issued 11 May 1988
Resolved
PROVIDE RAILS, A MINIMUM OF 36" IN HEIGHT FROM THE DECK, TO SURROUND THE AREA IN WHICH PASSENGERS ARE EMBARKED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.